Back to Authors

Nkomo, Vuyisile T.

https://orcid.org/0000-0001-6095-5579

Mayo Clinic

Mayo Clinic

Citations 158

Abstract 21016: Left Atrial Dysfunction Persists After Transapical but Not Transfemoral Transcatheter Aortic Valve Replacement and is Associated With Worse Outcomes
Fahim, Mirette, Eleid, Mackram F. , Greason, Kevin L. , Pislaru, Sorin V. , Pellikka, Patricia A. , Nkomo, Vuyisile T. , Pislaru, Cristina

Circulation | March 19, 2022 | Volume: 136 | Issue: suppl_1 | Pages: No page available

10.1161/circ.136.suppl_1.21016 Get It

Introduction and Aims of The Study: The relief of outflow obstruction after transcatheter aortic valve replacement (TAVR) is expected to improve cardiac output, LV systolic and diastolic function and to regress left ventricular (LV) mass. The impact of these changes on left atrial (LA) reservoir, conduit and contractile function remains unknown. Our aims were to compare LA functions in patients with transfemoral (TF) vs transapical (TA) TAVR and test whether they have an impact on patient outcomes. Methods: Retrospective analysis of LA deformation by speckle tracking strain echocardiography in 54 patients with TA TAVR and 54 TF TAVR, matched for age, sex and STS score. Measurements were performed pre TAVR and 1 month and 1 year post TAVR. Follow up data was available up to 5 years. Results: At baseline, there were no significant differences between the TF and TA groups with regard to patient age (81 ± 8 vs 82 ± 8 years), male gender (44% vs. 44%) or STS score (8.3 ± 4.4 vs 9.7 ± 4.5, respectively). LV filling pressures (E/e’) at baseline and 1 month were higher in TA vs. TF group (see table). LV global longitudinal strain (GLS) were similar at baseline and improved at 1 month only in the TF group (p=0.0001), while in the TA group it showed an improvement only at 1 year. LA reservoir, conduit and contractile functions improved within 1 month post TAVR in the TF group. In contrast, despite similar baseline LA functions in both groups, no improvement was observed in the TA group (see Table). At Cox proportional hazard analysis, lower LA reservoir function predicted major adverse events (death, cardiac rehospitalization or stroke) even after adjusting for age, gender and group allocation (p=0.034; risk ratio per unit decrease in LA function 1.04). Conclusion: These findings suggest that patients with TA TAVR have poor (if any) recovery of LA functions post TAVR. Presence of a stiff LA, best reflected by a persistently reduced LA reservoir strain, may contribute to the excess morbidity seen in TA patients.
Abstract 20052: Mortality Reduction With Angiotensin Receptor Blockers in Hypertension Patients With Left Ventricular Hypertrophy
Odunukan, Olufunso W. , Filsoof, David M., Hodge, David O. , Schultz, Alison B, Nyman, M. , Nkomo, Vuyisile T.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.20052 Get It

Background: Left ventricular hypertrophy (LVH) is considered a marker of stage B heart failure according to the ACC/AHA classification. Current guidelines recommend beta-blocker (BB) therapy for treatment but randomized control trials suggest that Angiotensin Receptor Blocker (ARB) therapy may be superior. Purpose: To compare survival among cohorts of LVH patients classified according to use of BB, ARB or neither (NONE) class of medications. Methods: A retrospective analysis of hypertension patients seen in the outpatient clinics was done. LVH was defined using the most stringent electrocardiogram (ECG) criteria whereas patients with minimal and moderate voltage criteria were excluded. Using hypertension medications from the year 2009 outpatient visits notes, 869 LVH patients were classified into BB (604), ARB (115) and NONE (150) cohort groups. Cox proportional hazard models were built. Results: Survival at 5 years was 85.2% with 17 deaths and 98 censored patients, (unadjusted hazard ratio HR 0.53, p=0.03) in the ARB cohort and 75.5 % with 148 deaths, 456 censored patients (HR 0.91, p=0.61) in the BB group compared to 74.0% in the NONE cohort with 39 deaths and 111 censored patients. After adjusting for age, sex, atrial fibrillation/flutter, heart failure, chronic kidney disease (CKD), coronary artery disease (CAD), acute myocardial infarction, stroke, obesity, diabetes, sleep apnea and pulmonary hypertension, HR was 0.40, p=0.006 for ARB and HR=0.80, p=0.278 for BB compared to the NONE group. At baseline, there was no significant difference in age, sex, and the prevalence in heart failure, stroke, obesity, sleep apnea, and pulmonary hypertension in all three groups although the BB group had significantly highest prevalence of atrial fibrillation/flutter, CAD, CKD and the lowest prevalence of diabetes. Conclusion: There was a significant mortality reduction benefit to hypertension patients with ECG diagnosed LVH treated with ARB which was not seen in similar patients on BB when compared to those treated with none of both medication classes. This effect persisted even after adjusting for cardiovascular comorbidities.
Abstract 16650: The Relationship Between Post Deployment Balloon Dilation and Cerebrovascular Events During Transcatheter Aortic Valve Replacement
Hoffman, Scott J., Slusser, Joshua P. , Lennon, Ryan J. , Brown, Robert D. , Suri, Rakesh M. , Greason, Kevin L. , Holmes, David R. , Goel, Kashish , Nkomo, Vuyisile T.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16650 Get It

Introduction: The risk of stroke or transient ischemic attack (TIA) remains increased after transcatheter aortic valve replacement (TAVR), especially in the first 30 days. Limited data is available regarding the impact of procedural characteristics on risk of stroke/TIA. Hypothesis: Post deployment balloon dilatation (PD) and total number of balloon dilatations (pre, valve and post insertion) may be associated with increased risk of stroke/TIA in patients undergoing TAVR. Methods: We included consecutive patients who underwent balloon-expandable TAVR until June 2014 at Mayo Clinic, Rochester. Patients who died in the operating room, converted to open surgery, or had valve-in-valve, or underwent self-expanding TAVR were excluded. Primary end-point was stroke or TIA at 30 days. Results: Mean age was 80.9±8 y, mean STS score was 8.3±5 and 50% underwent transfemoral access. The overall incidence of PD was 14% (n=53). Total number of dilations ranged from 2-7, with 5% (n=19) getting ≥ 4 total dilatations. Out of the 370 patients, 13 patients (3.5%) suffered stroke/TIA (9.4% in PD group vs. 2.2% in non-PD group) in the first 30 days after TAVR. Cox-proportional hazards regression analysis indicated that PD during TAVR was associated with a significantly increased risk of 30-day stroke/TIA (HR, 3.8; 95% CI, 1.2-11.6; p=0.02). There was a trend towards increased stroke/TIA with total number of dilations (HR, 1.5; 95% CI, 0.87-2.6; p=0.14), longer procedural time (HR per 30 minutes, 1.3; 95% CI, 0.96-1.7; p=0.09) and severity of atherosclerosis (moderate-severe - HR, 1.9; 95% CI 0.95- 3.8; p=0.07). PD was not significantly associated with the risk of 30 day death (HR, 1.1; 95% CI, 0.24-4.85; p=0.93). Conclusions: In patients undergoing PD after balloon-expandable TAVR, 9.4% suffered a stroke or TIA in the first 30 days. PD was associated with a four-fold increase in 30 day risk of stroke or TIA.
Risk of left atrial appendage thrombus and stroke in patients with atrial fibrillation and mitral regurgitation
Melduni, Rowlens M. , Nkomo, Vuyisile T. , Deshmukh, Abhishek , Padang, Ratnasari , Greene, Eddie L., Oh, Jae K. , Lee, Hon-Chi, Melduni, Rowlens , Padang, Ratnasari , Nkomo, Vuyisile T , Wysokiński, Waldemar E. , Gersh, Bernard J.

Heart | December 10, 2021 | Volume: 108 | Issue: 1 | Pages: 29-36

10.1136/heartjnl-2020-317659 Get It

Objective To investigate the association of mitral regurgitation (MR) on thromboembolic risk of patients with non-valvular atrial fibrillation (NVAF) undergoing transoesophageal echocardiography (TEE)-guided cardioversion. Methods Data for consecutive patients who underwent TEE-guided cardioversion for NVAF between 2000 and 2012 were analysed. MR severity was assessed by Doppler echocardiography and classified as ≤mild, moderate or severe. Left atrial appendage emptying velocities were averaged for five consecutive cycles. Multivariable regression models were used to identify independent predictors of left atrial appendage thrombus (LAAT) and stroke. Results 2950 patients (age, 69.3±12.2 years, 67% men) were analysed. 2173 (73.7%) had ≤mild MR; 631 (21.4%), moderate MR; and 146 (4.9%), severe MR. Patients with moderate (age, 72.4±10.7 years) and severe (age, 72.8±12.1 years) MR were older than those with ≤mild MR (age, 68.2±12.5 years). The prevalence of LAAT was 1.5% (n=43). CHA 2 DS 2 -VASc scores (≤mild MR, 3.0±1.6; moderate MR, 3.5±1.5; severe MR, 3.9±1.5; p<0.001) and heart failure frequency (≤mild MR, 38.4%; moderate MR, 48.0%; severe MR, 69.2%; p<0.001) were increasingly higher with greater MR severity. Multivariable logistic regression analysis showed no association of moderate MR (OR 0.77, 95% CI 0.38 to 1.56) or severe MR (OR 0.55, 95% CI 0.21 to 1.49) with LAAT. During a mean follow-up of 7.3±5.1 years (median 7.5, IQR, 2.7–10.9), 216 patients had an ischaemic stroke. Adjusted Cox regression analysis showed no significant association of moderate MR (HR 1.22, 95% CI 0.88 to 1.68) or severe MR (HR 0.73, 95% CI 0.31 to 1.46) with stroke. Conclusions Among patients with NVAF, the presence or severity of MR was not associated with a decreased risk of LAAT or stroke.
Reduction in Right Atrial Pressures Is Associated With Hemodynamic Improvements After Transcatheter Edge-to-Edge Repair of the Tricuspid Valve
Mahowald, Madeline , Nishimura, Rick A. , Pislaru, Sorin V., Mankad, Sunil V., Nkomo, Vuyisile T. , Padang, Ratnasari, Thaden, Jeremy J., Alkhouli, Mohamad , Guerrero, Mayra , Rihal, Charanjit S. , Eleid, Mackram F. , Mahowald, Madeline K , Alkhouli, Mohamad , Guerrero, Mayra E , Nkomo, Vuyisile T , Nishimura, Rick A , Pislaru, Sorin V., Mankad, Sunil V., Padang, Ratnasari, Thaden, Jeremy J., Rihal, Charanjit S. , Eleid, Mackram F

Circulation: Cardiovascular Interventions | November 24, 2021 | Volume: 14 | Issue: 12 | Pages: No page available

10.1161/circinterventions.121.010557 Get It

Background: Investigational transcatheter edge-to-edge repair (TEER) for severe tricuspid regurgitation (TR) has shown promise as an alternative to surgery, but factors influencing outcomes, optimal patient selection, and procedural timing remain incompletely defined. Given the limitations of determining TR severity by conventional echocardiography, our objectives were to determine whether invasive right atrial (RA) pressures performed during the procedure are related to patient outcomes. Methods: This study was a retrospective review of patients who underwent off-label tricuspid TEER using MitraClip (Abbott Vascular, Menlo Park, CA) for significant TR at a single institution. Intraprocedural mean RA pressure, RA peak V-wave, RA pressure nadir, and systolic increase in RA pressure (XV height) were recorded. Results: Thirty-eight patients underwent tricuspid TEER; 33 underwent concomitant mitral TEER for mitral regurgitation. The study cohort was 39% female with a mean age of 78.6±14.3 years. Median follow-up was 339 days (interquartile range, 100–601). Any reduction in mean RA pressure, RA peak V-wave, RA nadir, and XV height occurred in 74%, 82%, 45%, and 87% of patients, respectively. At 1 year, event-free survival was 47%. Postprocedure XV height correlated with TR severity as determined by echocardiography ( P <0.0001). The highest quartile of postprocedure XV height (>8 mm Hg) had worse event-free survival compared with those who had concluding XV height ≤8 mm Hg ( P =0.02). Attainment of a concluding XV height less than or equal to median value was associated with a lower creatinine the next day (1.27±0.47 versus 1.64±0.47 mg/dL, P =0.04). Conclusions: Intraprocedural XV height correlates with TR severity after tricuspid TEER, and lower concluding pressures are associated with improved outcomes. Analysis of RA pressures may serve as a complementary tool for the evaluation of disease severity and procedural guidance.
Predictors and Long-Term Impact of De Novo Aortic Regurgitation in Continuous Flow Left Ventricular Assist Devices Using Vena Contracta
Park, Jeong Rang , Brady, Peter A. , Clavell, Alfredo L. , Maleszewski, Joseph J. , Stulak, John M., Lin, Grace , Lin, Grace , Nkomo, Vuyisile T. , Pislaru, Sorin V.

ASAIO Journal | September 9, 2021 | Volume: 68 | Issue: 5 | Pages: 691-697

10.1097/mat.0000000000001564 Get It

The aim of this study was to identify the optimal echocardiographic measurement of aortic regurgitation (AR) in continuous flow left ventricular assist devices (LVAD) and determine risk factors and clinical implications of de novo AR. Echocardiographic images from consecutive patients who underwent LVAD implantation from February 2007 to March 2017 were reviewed. Severity of de novo AR was determined by vena contracta (VC). Preimplant clinical characteristics, LVAD settings at discharge, and outcomes including heart failure hospitalizations, all-cause mortality, and ventricular arrhythmias of patients with greater than or equal to moderate de novo AR were compared with those with mild or no AR. Among 219 patients, greater than or equal to moderate de novo AR occurred in 65 (29.7%). Left ventricular assist devices support duration was longer with greater than or equal to moderate AR than no or mild AR. In multivariable analysis, preimplant trivial AR and persistent aortic valve (AV) closure were independently associated with de novo AR. By time-varying covariate analysis, survival and freedom from cardiovascular events in greater than or equal to moderate AR were significantly worse (hazard ratio [HR] = 3.947, p < 0.001 and HR = 4.666, p < 0.001). In conclusion, de novo greater than or equal to moderate AR measured by VC increases risk of adverse events. Longer LVAD support duration, preimplant trivial AR, and a closed AV are associated with occurrence of greater than or equal to moderate de novo AR.
Effect of eliminating pre‐discharge transthoracic echocardiogram on outcomes after TAVR
Welle, Garrett A. , El‐Sabawi, Bassim , Thaden, Jeremy J. , Greason, Kevin L. , Klarich, Kyle W. , Gulati, Rajiv , Rihal, Charanjit S. , Eleid, Mackram F. , Alkhouli, Mohamad A, Eleid, Mackram F , Welle, Garrett A , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Crestanello, Juan A. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | August 13, 2021 | Volume: 99 | Issue: 3 | Pages: 861-866

10.1002/ccd.29929 Get It

AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
High Prevalence of Severe Aortic Stenosis in Low-Flow State Associated With Atrial Fibrillation
Khan, Sana , Thaden, Jeremy J. , El‐Am, Edward , Scott, Christopher G. , Morant, Kareem, Oğuz, Didem , Padang, Ratnasari , Lane, Colleen E. , McCully, Robert B. , Pellikka, Patricia A. , Oh, Jae K. , Alsidawi, Said , El-Am, Edward A, Scott, Christopher , Pellikka, Patricia A , Pislaru, Sorin V. , Luis, Sushil Allen , Nkomo, Vuyisile T.

Circulation: Cardiovascular Imaging | July 12, 2021 | Volume: 14 | Issue: 7 | Pages: No page available

10.1161/circimaging.120.012453 Get It

Background: Atrial fibrillation (AF) is a low-flow state and may underestimate aortic stenosis (AS) severity. Single-high Doppler signals (HS) consistent with severe AS (peak velocity ≥4 m/s or mean gradient ≥40 mm Hg) are averaged down in current practice. The objective for the study was to determine the significance of HS in AF low-gradient AS (LGAS). Methods: One thousand five hundred forty-one patients with aortic valve area ≤1 cm 2 and left ventricular ejection fraction ≥50% were identified and classified as high-gradient AS (HGAS) (≥40 mm Hg) and LGAS (<40 mm Hg), and AF versus sinus rhythm (SR). Available computed tomography aortic valve calcium scores (AVCS) were retrieved from the medical record. Outcomes were assessed. Results: Mean age was 76±11 years, female 47%. Mean gradient was 51±12 in SR-HGAS, 48±10 in AF-HGAS, 31±5 in SR-LGAS, and 29±7 mm Hg in AF-LGAS, all P ≤0.001 versus SR-HGAS; HS were present in 33% of AF-LGAS. AVCS were available in 34%. Compared with SR-HGAS (2409 arbitrary units; interquartile range, 1581–3462) AVCS were higher in AF-HGAS (2991 arbitrary units; IQR1978–4229, P =0.001), not different in AF-LGAS (2399 arbitrary units; IQR1817–2810, P =0.47), and lower in SR-LGAS (1593 arbitrary units; IQR945–1832, P <0.001); AVCS in AF-LGAS were higher when HS were present ( P =0.048). Compared with SR-HGAS, the age-, sex-, comorbidity index-, and time-dependent aortic valve replacement-adjusted mortality risk was higher in AF-HGAS (hazard ratio=1.82 [1.40–2.36], P <0.001) and AF-LGAS with HS (hazard ratio=1.54 [1.04–2.26], P =0.03) but not different in AF-LGAS without HS or SR-LGAS (both P =not significant). Conclusions: Severe AS was common in AF-LGAS. AVCS in AF-LGAS were not different from SR-HGAS. AVCS were higher and mortality worse in AF-LGAS when HS were present.
Clinical predictors and impact of postoperative mean gradient on outcome after transcatheter edge‐to‐edge mitral valve repair
Oğuz, Didem , Padang, Ratnasari , Mankad, Sunil , Reeder, Guy S., Eleid, Mackram F. , Rihal, Charanjit S. , Thaden, Jeremy J. , Mankad, Sunil V., Eleid, Mackram F , Pislaru, Sorin V. , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | July 10, 2021 | Volume: 98 | Issue: 6 | Pages: No page available

10.1002/ccd.29867 Get It

AbstractBackgroundThe predictors and clinical significance of increased Doppler‐derived mean diastolic gradient (MG) following transcatheter edge‐to‐edge mitral valve repair (MVTEER) remain controversial.ObjectiveWe sought to examine baseline correlates of Doppler‐derived increased MG post‐MVTEER and its impact on intermediate‐term outcomes.MethodsPatients undergoing MVTEER were analyzed retrospectively. Post‐MVTEER increased MG was defined as >5 mmHg or aborted clip implantation due to increased MG intraprocedurally. Baseline MG and 3D‐guided mitral valve area (MVA) by planimetry were retrospectively available in 233 and 109 patients.Results243 patients were included; 62 (26%) had MG > 5 mmHg post‐MVTEER or aborted clip insertion, including 7 (11%) that had aborted clip implantation. Mortality occurred in 63 (26%) during a median follow up of 516 days (IQR 211, 1021). Increased post‐MVTEER MG occurred more frequently in females (44% vs. 16%, p < 0.001), those with baseline MVA <4.0 cm2 (71% vs. 16%), baseline MG ≥4 mmHg (61% vs. 20%), or multiple clips implanted (33% vs. 21%, p = 0.04). Increased post‐MVTEER MG was associated with increased subsequent mortality compared to those with normal gradient (HR 1.91 95% CI 1.15–3.18 p = 0.016) as was aborted clip insertion compared to all others (HR 5.23 95% CI 2.06–13.28 p < 0.001).ConclusionsSmaller baseline MVA and increased baseline MG are associated with increased MG post‐MVTEER and patients with a Doppler‐derived post‐MVTEER MG >5 mmHg suffered excess subsequent mortality. In high risk patients considered for MVTEER, identification of those at risk of iatrogenic mitral stenosis with MVTEER is important as they may be optimally treated with alternate surgical or transcatheter therapies.
Abstract 18192: Aortic Stenosis: The Effect of Spectral Broadening in the Left Ventricular Outflow Tract on Stroke Volume and Calculated Aortic Valve Area
Thaden, Jeremy J. , Tsang, Michael , Suri, Rakesh M. , Foley, Thomas A. , Williamson, Eric E. , Oh, Jae K. , Ito, Saki , Pislaru, Sorin V. , Nkomo, Vuyisile T.

Circulation | July 3, 2021 | Volume: 130 | Issue: suppl_2 | Pages: No page available

10.1161/circ.130.suppl_2.18192 Get It

Introduction: Accurate stroke volume (SV) calculation is critical for calculating aortic valve area by echocardiography. 2D-Doppler estimation of SV (SV 2D ) assumes uniform blood flow velocities through the left ventricular outflow tract (LVOT). Non-uniform flow through the LVOT, appreciated as spectral broadening of the LVOT Doppler signal, could result in inaccurate SV calculation. Hypothesis: Increased spectral broadening in the LVOT will result in overestimation of SV by the SV 2D method compared to 3D volumetric assessment of SV (SV 3D ). Methods: Fifty-one consecutive patients with aortic stenosis underwent comprehensive 2D-TTE and assessment of SV 3D . Patients with ≥ moderate mitral or aortic regurgitation were excluded. An LVOT pulse-wave Doppler signal with > 0.4 m/s difference between outer and inner edge of velocity spectral display (at time of peak velocity) was considered non-uniform flow (i.e., spectral broadening). Results: Spectral broadening was present in 33% of the cohort. These patients were commonly female with smaller ventricles and higher ejection fraction. Spectral broadening was associated with a significant overestimation of SV on Doppler-based measurements (101±20 ml vs 78±15 mL, SV 2D vs SV 3D , respectively; r=0.83, p<0.0001); such differences were not seen in patients with uniform flow velocities (82±15 vs 79±14 mL, r=0.83, p=0.03). Patient characteristics by spectral broadening are shown in table 1. Conclusion: In aortic stenosis patients with non-uniform flow, Doppler-based methods overestimated SV by 29.5% on average (maximum 64%) when compared to 3D methods. This results in a proportional increase in calculated valve area despite a similar mean gradient between groups. Substituting SV 3D resulted in similar SV, valve area, and mean gradient between uniform and non-uniform groups. When spectral broadening >0.40 cm/s is present, 3D volumetric assessment of SV should be considered for accurate estimation of aortic valve area.