Back to Authors

Madhavan, Malini

https://orcid.org/0000-0002-2831-4568

Mayo Clinic

Mayo Clinic

Citations 93

Risk of Cardiovascular Implantable Electronic Device Infection in Patients Presenting With Gram-Negative Bacteremia
Chesdachai, Supavit , Baddour, Larry M. , Sohail, M. Rizwan , Palraj, Bharath Raj, Madhavan, Malini , Tabaja, Hussam , Lahr, Brian D. , DeSimone, Daniel C. , Palraj, Raj , DeSimone, Daniel C , Baddour, Larry , Sohail, M Rizwan , Palraj, Raj , Chesdachai, Supavit , Tabaja, Hussam , Fida, Madiha

Open Forum Infectious Diseases | August 25, 2022 | Volume: 9 | Issue: 9 | Pages: No page available

10.1093/ofid/ofac444 Get It

Abstract Background Gram-negative bacteremia (GNB) as a manifestation of cardiovascular implantable electronic device (CIED) infection is uncommon. Moreover, echocardiography may be nonspecific in its ability to differentiate whether CIED lead masses are infected. We aimed to determine the rate of CIED infection in the setting of GNB. Methods All patients with CIED who were hospitalized with GNB during 2012–2019 at Mayo Clinic were investigated. The definition of CIED infection was based on criteria recommended by the 2019 European Heart Rhythm Association document. Results A total of 126 patients with CIED developed GNB. None of them had signs of pocket infection. Twenty (15.9%) patients underwent transesophageal echocardiography. Overall, 4 (3%) patients had definite CIED infection. None of them underwent CIED extraction; 3 died within 12 weeks and 1 received long-term antibiotic suppression. Ten (8%) patients had possible CIED infection; despite no CIED extraction, no patient had relapsing GNB. We observed a higher rate of CIED infection in patients with Serratia marcescens bacteremia as compared to that in patients with other GNB. Conclusions The rate of CIED infection following GNB was relatively low. However, accurate classification of CIED infection among patients presenting with GNB remains challenging, in part, due to a case definition of CIED infection that is characterized by a low pretest probability in the setting of GNB. Prospective, multicenter studies are needed to determine accurate identification of CIED infection among GNB, so that only patients with true infection undergo device removal.
The subtle tine: Asymptomatic Micra perforation incidentally discovered during cardiac surgery
Tan, Nicholas Y. , Madhavan, Malini , Greason, Kevin L. , Cha, Yong‐Mei

Journal of Cardiovascular Electrophysiology | August 10, 2022 | Volume: 34 | Issue: 1 | Pages: 229-230

10.1111/jce.15653 Get It

Abstract A 70‐year‐old woman with longstanding persistent atrial fibrillation underwent Micra leadless pacemaker implantation and atrioventricular nodal ablation. No postprocedural complications were noted. She subsequently underwent surgical mitral valve replacement 4 years later. During the surgery, Micra tine perforation of the right ventricular free wall was seen. No device revision was performed due to her asymptomatic status and stable pacemaker position/function. Pericardial effusion is a known complication of Micra implantation. The incidence of tine perforation is unknown as many patients may be asymptomatic. The clinical consequences regarding adverse events, device functionality, and explantation/extraction risk profile remain to be determined.
Cardiac Implantable Electronic Devices in Ebstein Anomaly: Management and Outcomes
Tan, Nicholas Y. , Amin, Mustapha, McLeod, Christopher J. , Stephens, Elizabeth H. , Cannon, Bryan C. , Miranda, William R. , Connolly, Heidi M. , Egbe, Alexander C. , Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J , Stephens, Elizabeth H , Miranda, William R , Connolly, Heidi M , Egbe, Alexander C , Asirvatham, Samuel J , Madhavan, Malini , Dearani, Joseph A.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010744 Get It

Background: Optimal management of cardiac implantable electronic devices (CIEDs) in patients with Ebstein anomaly during tricuspid valve (TV) surgery is unknown. Thus, we aimed to characterize CIED management/outcomes in patients with Ebstein anomaly undergoing TV surgery. Methods: Patients at the Mayo Clinic from 1987 to 2020 with Ebstein anomaly and CIED procedure were reviewed for procedural details, complications, echocardiogram, and lead parameters. Five-year cumulative incidence of CIED complications were estimated using the Kaplan-Meier method. Results: Ninety-three patients were included; 51 were female, and mean age was 40.7±17.5 years. A new CIED was implanted in 45 patients at the time of TV surgery with the majority receiving an epicardial (n=37) CIED. Among 34 patients who had preexisting CIED (11 epicardial, 23 transvenous) at time of TV surgery, 20 had a transvenous right ventricular lead managed by externalizing the lead to the TV (n=15) or extracting the transvenous lead with epicardial lead implantation (n=5). Fourteen patients underwent CIED implantation (4 epicardial, 10 transvenous) without concurrent surgery. Placement of lead across the TV was avoided in 85% of patients. The 5-year cumulative incidence of CIED complications was 24% with no significant difference between epicardial and transvenous CIEDs (26% versus 23%, P =0.96). Performance of lead parameters was similar in epicardial and transvenous leads during median (interquartile range) follow-up of 44.5 (61.1) months. Conclusions: In patients with Ebstein anomaly undergoing TV surgery, the use of epicardial leads and externalization of transvenous leads to the TV can avoid lead placement across the valve leaflets. Lead performance and CIED complications was similar between epicardial and transvenous CIEDs.
Atrial Arrhythmia Ablation in Patients With D-Transposition of the Great Arteries and Atrial Switch
Chiriac, Anca , Cheema, Kamal Preet, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Umadat, Goyal , Hodge, David O. , Phillips, Sabrina D. , Madhavan, Malini , Asirvatham, Samuel J. , Cheema, Kamal P, Espinosa, Samantha M, Perez-Downes, Julio C , McLeod, Christopher J , Asirvatham, Samuel J , Giardi, Davide , McLeod, Christopher J.

Circulation: Arrhythmia and Electrophysiology | June 28, 2022 | Volume: 15 | Issue: 7 | Pages: No page available

10.1161/circep.121.010546 Get It

Background: Patients with D-transposition of the great arteries and atrial switch have a high incidence of atrial arrhythmias. We sought to analyze the arrhythmia substrate, ablation strategies, and outcomes for catheter ablation in this population. Methods: An in-depth analysis of all clinical and procedural data in patients with D-transposition of the great arteries, atrial baffles, and atrial arrhythmia ablation was performed. Results: A cohort of 32 patients (72% male, mean age 38±7 years) underwent ablation for non-AV nodal reentrant tachycardia atrial arrhythmias, and 4 patients underwent AV nodal reentrant tachycardia ablation. Cavotricuspid isthmus flutter (CTI-flutter) was the most common arrhythmia, encountered in 75% of patients, followed by scar-related intraatrial reentrant tachycardia (non-CTI intraatrial reentrant tachycardia, 53%) and focal atrial tachycardia (focal atrial tachycardia, 6%). Among the 32 patients, 26 underwent 31 procedures at our institution. For patients with prior outside intervention, the index ablation at our institution revealed CTI-dependent flutter in 3/5 cases. However, redo ablation after an index ablation with demonstrated bidirectional CTI block revealed different/new arrhythmia substrates (80% non-CTI intraatrial reentrant tachycardia, 40% focal atrial tachycardia). Achieving bidirectional block across the CTI often required ablating on both sides of the baffle (retroaortic access, 81%; using a baffle leak, 11.5%; or transbaffle puncture, 7.7%). Combined approaches were necessary in 19% to reach the critical tissue. Acute procedural success was 81%, and recurrence was documented in 58% of patients. Despite recurrence, clinical arrhythmia burden was significantly reduced post-ablation ( P <0.001), with rare episodes, amenable to antiarrhythmic therapy. Redo ablation was required in 5 (19%) patients and uncovered new arrhythmia substrates. AV nodal reentrant tachycardia ablation also required transbaffle approaches in 3/4 patients. Conclusions: CTI-dependent flutter was the most common arrhythmia in patients with Dextro-Transposition of the Great Arteries and atrial switch. Transbaffle approaches were often necessary, and, provided that bidirectional CTI block was achieved at the index ablation, late recurrence was due to different arrhythmia mechanisms. Despite recurrence, ablation was associated with significant clinical improvement.
One-year outcomes of catheter ablation for atrial fibrillation in young patients
Patel, Harsh , Patel, Kirtenkumar , Jaswaney, Rahul , Thakkar, Samarthkumar , Kowlgi, Narayan G., Arora, Shilpkumar , Mulpuru, Siva K. , Madhavan, Malini , Killu, Ammar M. , Cha, Yong‐Mei , Deshmukh, Abhishek , Tseng, Andrew S. , Kumar, Ashish , Jani, Chinmay , Kowlgi, Narayan G., Dani, Sourbha S. , DeSimone, Christopher V.

No container title available | May 18, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-1399820/v1 Get It

Abstract Background: Atrial fibrillation (AF) is relatively less frequent in younger patients (age<50). Recently, studies have suggested that early restoration of sinus rhythm may lead to improved outcomes compared with rate control. Methods: We included all hospitalized patients between 18 and 50 years with a diagnosis of AF from the Nationwide Readmission Database 2016-2017 from the Healthcare Cost and Utilization Project. Demographic and comorbidity data were collected and analyzed. Outcomes assessed included one-year AF readmission rates, all-cause readmission, ischemic stroke, and all-cause mortality. Subgroup analyses were performed for all demographic and comorbidity variables.Results: Overall, 52,598 patients (medium age 44, interquartile range 38-48, female 25.7%) were included in the study, including 2,146 (4.0%) who underwent catheter ablation for AF. Patients who underwent catheter ablation had a significantly lower rate of readmission for AF or any cause at one year (adjusted hazard ratios (HR) of 0.52 [95% confidence interval (CI): 0.43-0.63] and HR of 0.81 [95% CI: 0.72 - 0.89], respectively). There was no difference in 1-year readmission for stroke or all-cause mortality between the two groups. Subgroup analyses showed a consistent reduction in the risk of AF readmission among major demographic and comorbidity subgroups.Conclusion: Catheter ablation in young patients with AF was associated with a reduction in 1-year AF related and all-cause readmissions. These data merit further prospective investigation for validation.
Abstract 12187: Arrhythmia Substrate and Approaches for First-Time and Repeat Catheter Ablation in Patients With D-transposition of the Great Arteries and Atrial Baffles
Chiriac, Anca , Cheema, Kamal Preet P, Giardi, Davide , Espinosa, Samantha , Fitzgerald, Patrick , Perez-Downes, Julio , Phillips, Sabrina D. , Madhavan, Malini , Umadat, Goyal , Asirvatham, Samuel J. , McLeod, Christopher J.

Circulation | April 28, 2022 | Volume: 144 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.144.suppl_1.12187 Get It

Introduction: Atrial arrhythmias are common in patients with D-TGA and atrial switch. We sought to analyze the arrhythmia substrate and catheter ablation approaches and outcomes. Methods: We performed a retrospective review of all clinical and procedural data in patients with D-TGA followed at a large tertiary care center. Results: In a cohort of 152 patients (mean age 30±11 years), atrial tachycardia was present in 69(45%) patients. Ablations were performed in 39(26%) patients: macro-reentrant atrial flutter (N=37), atrial fibrillation (N=4), and focal automatic atrial tachycardia (N=3). Detailed electrophysiology study data was available for 34 patients. At first ablation (N=28), cavo-tricuspid isthmus dependent flutter (CTI, 23(82%)) was most common, followed by right atriotomy-related flutter (IART, 16(57%)) and focal atrial tachycardia (FAT, 1(3.5%)). Bidirectional CTI block often required ablation on both sides of the baffle to complete the isthmus line. Access to the pulmonary venous atrium was obtained in 82% of first-time ablations (via retrograde aortic access, 74%, baffle puncture, 6%, or baffle fenestration, 12%) and in 100% of redo procedures. The first ablation was acutely successful in 25 (89%) patients; the other 3 patients had either partial procedural success (1), failed ablation (1), or underwent an empirical ablation (1). Long-term arrhythmia recurrence occurred in 13(46%) after the first ablation and class III antiarrhythmic medications were utilized in 12 patients. At least one long-term recurrence occurred in 11(44%) patients. Importantly, clinical arrhythmia burden was significantly reduced post-ablation, with rare and short-limited episodes amenable to antiarrhythmic drugs or cardioversion. Repeat ablation was required in 3 cases. Long-term arrhythmia recurrence after a previously completed CTI line involved different arrhythmia mechanisms: scar-related reentry (80%) and automatic atrial tachycardia (40%). Conclusions: Atrial arrhythmia in patients with D-TGA often involves the CTI and atriotomy scars. Ablation of the CTI typically requires access to the pulmonary venous atrium to achieve bidirectional block. Despite late recurrence, the clinical arrhythmic burden is substantially improved.
Vein of Marshall alcohol ablation for dormant pulmonary vein conduction: A case report
Janga, Chaitra , Madhavan, Malini , Siontis, Konstantinos C. , Killu, Ammar M.

Journal of Cardiovascular Electrophysiology | March 25, 2022 | Volume: 33 | Issue: 5 | Pages: 1070-1071

10.1111/jce.15466 Get It

AbstractWe report a case of alcohol ablation into a vein of Marshall for recurrent dormant conduction into the pulmonary veins with adenosine testing in a patient where two prior ablation attempts failed to isolate the left vein.
Abstract 16261: Risk of Stroke or Systemic Embolism After Transseptal Ablation in Patients With Implanted Cardiac Devices
Madhavan, Malini , Sangaralingham, Lindsey R. , Noseworthy, Peter A. , DeSimone, Christopher V. , McLeod, Christopher J. , Asirvatham, Samuel J. , Yao, Xiaoxi

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16261 Get It

Introduction: Mobile thrombi are commonly observed on endovascular leads at the time of catheter ablation. Transseptal puncture poses a risk of paradoxical embolism. We sought to examine the risk of stroke or systemic embolism after transseptal ablation in patients with and without cardiac implantable electronic devices (CIEDs). Methods: Using a large, national administrative claims database we identified 31,720 patients who underwent a catheter ablation requiring transseptal puncture between 1/1/2004 and 9/30/2014. We created two propensity-matched cohorts, matching on age, gender, race, household income, region, Charlson index, CHADS-Vasc score, and year and indication for ablation (5,533 patients with CIEDs and 11,300 patients without devices). Incidence rates (events/100 patient-years) and propensity score-matched cox proportional hazards models (with 95% confidence intervals) were used to estimate risk of stroke, transient ischemic attack, or systemic embolism for patients with or without CIEDs. We also examined the impact of presence of a CIED and oral anticoagulation (OAC) use on risk of stroke or systemic embolism within the matched cohort. Average follow up was 2.1 years. Results: The event rate was 1.5 per 100 person years in patients without device, and 1.9 per 100 person years in patients with device. Among patients not on OAC, presence of a cardiac device was associated with an increased risk of stroke or systemic embolism (HR 1.71 [1.24-2.35], P<0.01) whereas there was no association among patients treated with OAC (0.98 [0.75_1.28], p=ns) (Figure). Conclusions: Cardiac devices are associated with an increased risk of stroke or systemic embolism after transseptal ablation, but this risk is attenuated with post ablation OAC use. Anticoagulation should be considered for all patients with CIEDs post transseptal ablation, regardless of the presence of another compelling indication for anticoagulation.
A real‐world experience of atrioventricular synchronous pacing with leadless ventricular pacemakers
Kowlgi, Gurukripa N. , Tseng, Andrew S. , Tempel, Nathan D., Henrich, Mark, Venkatachalam, Kalpathi L., Scott, Luis R. , Shen, Win‐Kuang , Deshmukh, Abhishek , Madhavan, Malini , Lee, Hon‐Chi, Asirvatham, Samuel J. , Friedman, Paul A. , Cha, Yong‐Mei , Mulpuru, Siva K. , Henrich, Mark J, Deshmukh, Abhishek J , Tseng, A S , Asirvatham, Samuel J , Kowlgi, Narayan G

Journal of Cardiovascular Electrophysiology | March 2, 2022 | Volume: 33 | Issue: 5 | Pages: 982-993

10.1111/jce.15430 Get It

AbstractAimsThe MicraTM transcatheter pacing system (TPS) (Medtronic) is the only leadless pacemaker that promotes atrioventricular (AV) synchrony via accelerometer‐based atrial sensing. Data regarding the real‐world experience with this novel system are scarce. We sought to characterize patients undergoing MicraTM‐AV implants, describe percentage AV synchrony achieved, and analyze the causes for suboptimal AV synchrony.MethodsIn this retrospective cohort study, electronic medical records from 56 consecutive patients undergoing MicraTM‐AV implants at the Mayo Clinic sites in Minnesota, Florida, and Arizona with a minimum follow‐up of 3 months were reviewed. Demographic data, comorbidities, echocardiographic data, and clinical outcomes were compared among patients with and without atrial synchronous ventricular pacing (AsVP) ≥ 70%.ResultsSixty‐five percent of patients achieved AsVP ≥ 70%. Patients with adequate AsVP had smaller body mass indices, a lower proportion of congestive heart failure, and prior cardiac surgery. Echocardiographic parameters and procedural characteristics were similar across the two groups. Active device troubleshooting was associated with higher AsVP. The likely reasons for low AsVP were small A4‐wave amplitude, high ventricular pacing burden, and inadequate device reprogramming. Importantly, in patients with low AsVP, subjective clinical worsening was not noted during follow‐up.ConclusionWith the increasing popularity of leadless pacemakers, it is paramount for device implanting teams to be familiar with common predictors of AV synchrony and troubleshooting with MicraTM‐AV devices.
Atrial fibrillation in partial anomalous pulmonary venous return: right atrial drainage from one vein and epicardial conduction from another vein
Bhalla, Jaideep Singh , Zyl, Martin van , Madhavan, Malini , Bhalla, Jaideep

EP Europace | February 1, 2022 | Volume: 24 | Issue: 9 | Pages: 1459-1459

10.1093/europace/euac006 Get It