Back to Authors

Behfar, Atta

https://orcid.org/0000-0003-3775-5784

Mayo Clinic

Mayo Clinic

Citations 122

Diastolic Pulmonary Gradient as a Predictor of Right Ventricular Failure After Left Ventricular Assist Device Implantation
Alnsasra, Hilmi , Schettle, Sarah , Pereira, Naveen L. , Frantz, Robert P. , Edwards, Brooks S., Clavell, Alfredo L. , Maltais, Simon, Daly, Richard C. , Stulak, John M., Rosenbaum, Andrew , Behfar, Atta , Kushwaha, Sudhir S. , Asleh, Rabea , Schettle, Sarah D., Rosenbaum, Andrew N , Behfar, Atta , Frantz, Robert P

Journal of the American Heart Association | August 14, 2019 | Volume: 8 | Issue: 16 | Pages: No page available

10.1161/jaha.119.012073 Get It

Background Diastolic pulmonary gradient ( DPG ) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance ( PVR ) and transpulmonary gradient ( TPG ). The prognostic significance of DPG in patients requiring a left ventricular assist device ( LVAD ) remains unclear. We sought to investigate whether pre‐ LVAD DPG is a predictor of survival or right ventricular ( RV ) failure post‐ LVAD . Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all‐cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan–Meier analyses. After a mean follow‐up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [ HR ]: 3.30; P =0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR ( HR 1.85, P =0.13 for PVR ≥3 versus PVR <3) or TPG ( HR 1.47, P =0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk ( HR 1.16, P =0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR , but not TPG , was associated with higher mortality risk ( HR 1.55; P =0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
Ventricular remodeling in ischemic heart failure stratifies responders to stem cell therapy
Yamada, Satsuki , Arrell, D. Kent , Rosenow, Christian S. , Behfar, Atta , Behfar, Atta , Bartúnek, Jozef , Terzic, André

Stem Cells Translational Medicine | August 2, 2019 | Volume: 9 | Issue: 1 | Pages: 74-79

10.1002/sctm.19-0149 Get It

Abstract Response to stem cell therapy in heart failure is heterogeneous, warranting a better understanding of outcome predictors. This study assessed left ventricular volume, a surrogate of disease severity, on cell therapy benefit. Small to large infarctions were induced in murine hearts to model moderate, advanced, and end-stage ischemic cardiomyopathy. At 1 month postinfarction, cardiomyopathic cohorts with comparable left ventricular enlargement and dysfunction were randomized 1:1 to those that either received sham treatment or epicardial delivery of cardiopoietic stem cells (CP). Progressive dilation and pump failure consistently developed in sham. In comparison, CP treatment produced significant benefit at 1 month post-therapy, albeit with an efficacy impacted by cardiomyopathic stage. Advanced ischemic cardiomyopathy was the most responsive to CP-mediated salvage, exhibiting both structural and functional restitution, with proteome deconvolution substantiating that cell therapy reversed infarction-induced remodeling of functional pathways. Moderate cardiomyopathy was less responsive to CP therapy, improving contractility but without reversing preexistent heart enlargement. In end-stage disease, CP therapy showed the least benefit. This proof-of-concept study thus demonstrates an optimal window, or “Goldilocks principle,” of left ventricular enlargement for maximized stem cell-based cardiac repair. Disease severity grading, prior to cell therapy, should be considered to inform regenerative medicine interventions. Significance statement This article documents that cardiac chamber enlargement postinfarction is a predictor of cardiopoietic stem cell therapy response. Left ventricular size pretherapy could thus serve to guide the selection of ischemic heart failure candidates most suitable to receive a regenerative intervention.
Safety and Risk of Major Complications With Diagnostic Cardiac Catheterization
Al‐Hijji, Mohammed , Lennon, Ryan J. , Gulati, Rajiv , Sabbagh, Abdallah El , Park, Jae Yoon, Crusan, Daniel J. , Kanwar, Amrit , Behfar, Atta , Holmes, David R. , Bell, Malcolm R. , Al-Hijji, Mohammed A , Crusan, Daniel, Bell, Malcolm, Behfar, Atta , Park, Jae Yoon, Lerman, Amir , Singh, Mandeep

Circulation: Cardiovascular Interventions | July 9, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007791 Get It

Background: We aim to study the incidence of major complications related to procedure defined as in-hospital death, myocardial infarction, stroke, pericardial effusion or tamponade, percutaneous coronary intervention due to iatrogenic coronary dissection, or unplanned bypass surgery within 72 hours after diagnostic left heart catheterization (LHC; primary end point). Furthermore, all causes of in-hospital death after LHC were adjudicated and reported (secondary end point). Methods and Results: Diagnostic LHC procedures (aortic angiography; coronary, including graft, angiography; and left ventricular angiography) from January 1, 2002, through December 31, 2013, were identified using the clinical scheduling system at Mayo Clinic, Rochester, and complications were identified through electronic records. International Classification of Diseases, Ninth Revision billing codes were used. Registration was queried to identify all-cause mortality. All events were reviewed and adjudicated. There were 43 786 diagnostic LHC procedures; 97.3% were coronary angiograms. The mean age of patients was 64.5 years (13.6), and the majority were male (61.5%). Primary end point was seen in 36 (0.082%) procedures or 8.2 of 10 000 LHCs. Combined right sided procedures with LHC did not increase the risk of major complications. Cardiogenic and septic shock, cardiac arrhythmia, and postsurgical complication were the most common causes of in-hospital death after LHC. Conclusions: The overall rates of major complications related to diagnostic cardiac catheterization procedures are extremely rare. The majority of the deaths occurring post-diagnostic LHC procedures were secondary to acute illness rather than directly related to diagnostic procedure.
Regeneration for All: An Odyssey in Biotherapy
Behfar, Atta , Behfar, Atta , Terzic, André

European Heart Journal | April 1, 2019 | Volume: 40 | Issue: 13 | Pages: 1033-1035

10.1093/eurheartj/ehz095 Get It

Novel Left Heart Catheterization Ramp Protocol to Guide Hemodynamic Optimization in Patients Supported With Left Ventricular Assist Device Therapy
Rosenbaum, Andrew , Frantz, Robert P. , Kushwaha, Sudhir S. , Stulak, John M., Maltais, Simon, Behfar, Atta , Rosenbaum, Andrew N , Behfar, Atta , Frantz, Robert P

Journal of the American Heart Association | February 13, 2019 | Volume: 8 | Issue: 4 | Pages: No page available

10.1161/jaha.118.010232 Get It

Background Left ventricular (LV) hemodynamic assessment has been sparsely performed in patients supported on continuous‐flow LV assist devices (cf LVADs ). Insight into dynamic changes of left heart parameters during ramp studies may improve LV assist device optimization and evaluate pathology. Methods and Results To complement right heart catheterization, a novel technique for left heart catheterization in patients with a cf LVAD was developed. Patients implanted with cf LVAD s underwent hemodynamic ramp left heart catheterization and right heart catheterization with transthoracic echocardiography. Continuous aortic and LV pressures were measured along with right atrial, pulmonary artery, and pulmonary capillary wedge pressures. A novel index, the transaortic gradient ( TAG ) was established. Thirty eight patients with cf LVADs were evaluated at a median of 446 days (interquartile range, 183–742) after device implant. During left heart catheterization performed for hemodynamic optimization, drop‐in LV end‐diastolic pressure and pulmonary capillary wedge pressure were associated with a rise in TAG . A range was identified for TAG (20–40 mm Hg) as providing the most optimal level of hemodynamic offloading. Pathologic states deviated from normal responses to ramp. LV assist device thrombosis was associated with an inability to increase in TAG during speed ramp. Significant aortic insufficiency was associated with a marked increase in LV end‐diastolic pressure despite a concomitant decrease in pulmonary capillary wedge pressure with increasing LV assist device speeds. Conclusions Inclusion of left heart catheterization to a typical right heart catheterization LV assist device ramp protocol imparted unique insights to optimize cf LVAD speeds in different clinical scenarios. A novel index, the TAG was defined and provided additional resolution to optimized offloading.
2094. Pulmonary Artery Catheter Epidemiology of Risk (PACER) Study
Lahr, Brian D. , Sampathkumar, Priya , Yetmar, Zachary A. , O’Horo, John C. , Behfar, Atta , Beam, Elena

Open Forum Infectious Diseases | November 26, 2018 | Volume: 5 | Issue: suppl_1 | Pages: S614-S614

10.1093/ofid/ofy210.1750 Get It

Elimination of Purkinje Fibers by Electroporation Reduces Ventricular Fibrillation Vulnerability
Livia, Christopher , Sugrue, Alan , Witt, Tyra A. , Polkinghorne, Murray , Maor, Elad , Behfar, Atta , Asirvatham, Samuel J. , Witt, Tyra, Polkinghorne, Murray D, Kapa, Suraj , Lehmann, Helge I, Behfar, Atta , Asirvatham, Samuel J , Livia, Christopher , Maor, Elad , Lehmann, H. Immo , DeSimone, Christopher V. , McLeod, Christopher J.

Journal of the American Heart Association | September 16, 2018 | Volume: 7 | Issue: 15 | Pages: No page available

10.1161/jaha.118.009070 Get It

Background The Purkinje network appears to play a pivotal role in the triggering as well as maintenance of ventricular fibrillation. Irreversible electroporation ( IRE ) using direct current has shown promise as a nonthermal ablation modality in the heart, but its ability to target and ablate the Purkinje tissue is undefined. Our aim was to investigate the potential for selective ablation of Purkinje/fascicular fibers using IRE . Methods and Results In an ex vivo Langendorff model of canine heart (n=8), direct current was delivered in a unipolar manner at various dosages from 750 to 2500 V, in 10 pulses with a 90‐μs duration at a frequency of 1 Hz. The window of ventricular fibrillation vulnerability was assessed before and after delivery of electroporation energy using a shock on T‐wave method. IRE consistently eradicated all Purkinje potentials at voltages between 750 and 2500 V (minimum field strength of 250–833 V/cm). The ventricular electrogram amplitude was only minimally reduced by ablation: 0.6±2.3 mV ( P =0.03). In 4 hearts after IRE delivery, ventricular fibrillation could not be reinduced. At baseline, the lower limit of vulnerability to ventricular fibrillation was 1.8±0.4 J, and the upper limit of vulnerability was 19.5±3.0 J. The window of vulnerability was 17.8±2.9 J. Delivery of electroporation energy significantly reduced the window of vulnerability to 5.7±2.9 J ( P =0.0003), with a postablation lower limit of vulnerability=7.3±2.63 J, and the upper limit of vulnerability=18.8±5.2 J. Conclusions Our study highlights that Purkinje tissue can be ablated with IRE without any evidence of underlying myocardial damage.
M 3 RNA Drives Targeted Gene Delivery in Acute Myocardial Infarction
Singh, Raman Deep , Hillestad, Matthew L. , Livia, Christopher , Alekseev, Alexey E., Witt, Tyra A. , Stalboerger, Paul G., Behfar, Atta , Yamada, Satsuki , Behfar, Atta , Livia, Christopher , Li, Mark, Terzic, André

Tissue Engineering Part A | July 26, 2018 | Volume: 25 | Issue: 1-2 | Pages: 145-158

10.1089/ten.tea.2017.0445 Get It

Posology for Regenerative Therapy
Behfar, Atta , Behfar, Atta , Terzic, André

Circulation Research | November 9, 2017 | Volume: 121 | Issue: 11 | Pages: 1213-1215

10.1161/circresaha.117.312074 Get It

Pulmonary Pressure Assessment with the Total Artificial Heart
Joyce, David L. , Redfield, Margaret M. , Kushwaha, Sudhir S. , Behfar, Atta , Borlaug, Barry A. , Daly, Richard C. , Sandhu, Gurpreet S. , Joyce, Lyle D., Behfar, Atta , Borlaug, Barry A

ASAIO Journal | July 25, 2017 | Volume: 64 | Issue: 3 | Pages: e34-e36

10.1097/mat.0000000000000632 Get It

Reversal of pulmonary hypertension has been observed in patients during a bridge to transplant with a left ventricular assist device. Total artificial heart (TAH) implant prevents subsequent right heart catheterization. Consequently, controversy exists over whether the prosthetic right ventricle improves or exacerbates pulmonary hypertension. A pulmonary artery (PA) pressure monitor was placed in two patients undergoing TAH implant, as a bridge to transplant. One patient had pulmonary hypertension at implant; the other had normal pulmonary pressures. Daily measurements were taken of systolic, diastolic, and mean PA pressures throughout support. Patient 1 received successful transplant after TAH support of 91 days. Systolic/diastolic (mean) PA pressures steadily decreased from 55/39 (28) mm Hg at implant to 29/18 (7) mm Hg currently. Patient 2 received support for 101 days before death due to abdominal ischemic complications. Pulmonary arterial pressures stayed consistent throughout this period, from 26/17 (20) mm Hg at implant to 23/13 (17) mm Hg at the time of death. These findings suggest that an implantable PA pressure monitor may be useful in optimizing hemodynamics and planning appropriate timing of transplant with TAH support.