Back to Authors

Packer, Douglas L.

https://orcid.org/0000-0003-2060-869X

Mayo Clinic

Intermountain Medical Center

Citations 108

2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation: Executive summary
Calkins, Hugh , Hindricks, Gerhard , Cappato, Riccardo , Kim, Young‐Hoon , Aguinaga, Luis, Akar, Joseph G. , Badhwar, Vinay , Camm, A. John , Chen, Peng‐Sheng , Chen, Shih‐Ann , Chung, Mina K. , Nielsen, Jens Cosedis , Curtis, Anne B. , Davies, D. Wyn, Groot, Natasja M.S. de , Duytschaever, Mattias , Edgerton, James R. , Ellenbogen, Kenneth A. , Ernst, Sabine , Fenelon, Guilherme , Gerstenfeld, Edward P. , Haines, David E. , Haïssaguerre, Michel , Jackman, Warren M. , Jalife, José , Kalman, Jonathan M. , Kautzner, Josef , Kottkamp, Hans , Kuck, Karl Heinz, Kumagai, Koichiro , Lee, Richard, Lewalter, Thorsten , Lindsay, Bruce D., Mansour, Moussa , Michaud, Gregory F., Nakagawa, Hiroshi , Natale, Andrea , Okumura, Ken , Packer, Douglas L. , Reynolds, Matthew R. , Sanders, Prashanthan , Scanavacca, Maurício , Schilling, Richard J. , Tondo, Claudio , Tsao, Hsuan-Ming, Verma, Atul , Wilber, David J. , Haı̈ssaguerre, Michel , Packer, Douglas, Verma, Atul , Natale, Andrea , Sanders, Prashanthan , Nielsen, Jens C , de Groot, Natasja M S , Saad, Eduardo , Brugada, Josép , Day, John , d'Avila, Andre , Biase, Luigi Di , Ellinor, Patrick T. , Haissaguerre, Michel , Helm, Robert H. , Hylek, Elaine M. , Macle, Laurent , Marchlinski, Francis E. , Michaud, Gregory F. , Nattel, Stanley , Pokushalov, Evgeny A. , Tsao, Hsuan-Ming, Yamane, Teiichi , Scanavacca, Maurício , Tondo, Claudio , Ernst, Sabine , Ellenbogen, Kenneth A

EP Europace | January 5, 2018 | Volume: 20 | Issue: 1 | Pages: 157-208

10.1093/europace/eux275 Get It

Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures
Lee, Justin Z. , Ling, Jayna, Diehl, Nancy N. , Hodge, David O. , Padmanabhan, Deepak , Killu, Ammar M. , Madhavan, Malini , Cha, Yong‐Mei , Deshmukh, Abhishek , Shen, Win-Kuang, Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Packer, Douglas L. , Mulpuru, Siva K. , Kapa, Suraj , Asirvatham, Samuel J , Noseworthy, Peter A. , McLeod, Christopher J. , Srivathsan, Komandoor , Kusumoto, Fred

Circulation | October 18, 2017 | Volume: 137 | Issue: 1 | Pages: 24-33

10.1161/circulationaha.117.030523 Get It

Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model
Eichhorn, Anna, Constantinescu, A., Kaderka, Robert, Prall, Matthias, Lugenbiel, Patrick , Takami, Mitsuru , Thomas, Dierk , Bert, Christoph , Packer, Douglas L. , Graeff, Christian , Lehmann, H. Immo , Bert, Christoph , Durante, Marco , Graeff, Christian , Richter, Daniel , Prall, M. W., Durante, Marco

Physics in Medicine & Biology | June 23, 2017 | Volume: 62 | Issue: 17 | Pages: 6869-6883

10.1088/1361-6560/aa7b67 Get It

Abstract Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R – R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage ( D 95 and V 95), heterogeneity (HI = D 5– D 95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D 95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.
Response by Fender et al to Letter Regarding Article, “Severe Pulmonary Vein Stenosis Resulting From Ablation for Atrial Fibrillation: Presentation, Management, and Clinical Outcomes”
Fender, Erin A. , Holmes, David R. , Packer, Douglas L. , Widmer, R. Jay

Circulation | May 1, 2017 | Volume: 135 | Issue: 18 | Pages: No page available

10.1161/circulationaha.117.027480 Get It

External Arrhythmia Ablation Using Photon Beams
Deisher, A., Takami, Mitsuru , Kruse, Jon J. , Song, Limin, Anderson, Sarah , Cusma, Jack T., Parker, Kay D., Johnson, Susan B., Asirvatham, Samuel J. , Miller, Robert C. , Herman, Michael , Packer, Douglas L. , Lehmann, H. Immo , Deisher, Amanda J, Anderson, Sarah E, Herman, Michael G., Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | April 13, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circep.116.004304 Get It

Background— This study sought to investigate external photon beam radiation for catheter-free ablation of the atrioventricular junction in intact pigs. Methods and Results— Ten pigs were randomized to either sham irradiation or irradiation of the atrioventricular junction (55, 50, 40, and 25 Gy). Animals underwent baseline electrophysiological evaluation, cardiac gated multi-row computed tomographic imaging for beam delivery planning, and intensity-modulated radiation therapy. Doses to the coronary arteries were optimized. Invasive follow-up was conducted ≤4 months after the irradiation. A mean volume of 2.5±0.5 mL was irradiated with target dose. The mean follow-up length after irradiation was 124.8±30.8 days. Out of 7 irradiated animals, complete atrioventricular block was achieved in 6 animals of all 4 dose groups (86%). Using the same targeting margins, ablation lesion size notably increased with the delivered dose because of volumetric effects of isodose lines around the target volume. The mean macroscopically calculated atrial lesion volume for all 4 dose groups was 3.8±1.1 mL, lesions extended anteriorly into the interventricular septum. No short-term side effects were observed. No damage was observed in the tissues of the esophagus, phrenic nerves, or trachea. However, histology revealed in-field beam effects outside of the target volume. Conclusions— Single-fraction doses as low as 25 Gy caused a lesion with interruption of cardiac impulse propagation using this respective target volume. With doses of ≤55 Gy, maximal point-doses to coronary arteries could be kept <7Gy, but target conformity of lesions was not fully achieved using this approach.
Integration of myocardial scar identified by preoperative delayed contrast-enhanced MRI into a high-resolution mapping system for planning and guidance of VT ablation procedures
Rettmann, Maryam E. , Suzuki, Atsushi , Wang, S., Pottinger, Nathan, Arter, James, Netzer, A, Viker, Kimberly, Packer, Douglas L. , Parker, K.

SPIE Proceedings | March 3, 2017 | Volume: 10135 | Issue: No issue available | Pages: 101351P

10.1117/12.2255933 Get It

Incidence of Idiopathic Ventricular Arrhythmias
Sirichand, Surksha , Killu, Ammar M. , Padmanabhan, Deepak , Hodge, David O. , Chamberlain, Alanna M. , Brady, Peter A. , Packer, Douglas L. , Munger, Thomas M. , Shen, Win-Kuang, Cha, Yong‐Mei , Asirvatham, Samuel J. , Friedman, Paul A. , Mulpuru, Siva K. , Kapa, Suraj , Noseworthy, Peter A. , Gersh, Bernard J. , McLeod, Christopher J. , Asirvatham, Samuel J , Chamberlain, Alanna M

Circulation: Arrhythmia and Electrophysiology | February 9, 2017 | Volume: 10 | Issue: 2 | Pages: No page available

10.1161/circep.116.004662 Get It

Background— Ventricular tachycardia and premature ventricular complexes (PVCs) most frequently occur in the context of structural heart disease. However, the burden of idiopathic ventricular arrhythmias (IVA) in the general population is unknown. Methods and Results— We identified incident cases of IVA between 2005 and 2013 from Olmsted County, Minnesota, using the Rochester Epidemiology Project database. For PVC cohorts, we included those with frequent (defined as ≥100 PVC/24 hours) symptomatic PVCs. We defined IVA-associated cardiomyopathy as a drop in ejection fraction of ≥10% from baseline. Between 2005 and 2013, we identified 614 individuals with incident IVA (229 [37.3%] were male; average age was 52.1±17.2 years). Of these, 177 (28.8%) had idiopathic ventricular tachycardia, 408 (66.5%) had symptomatic PVCs, and 29 (4.7%) had IVA-associated cardiomyopathy. The age- and sex-adjusted incidence rates in 2005 to 2007, 2008 to 2010, and 2011 to 2013 were 44.9 per 100 000 (95% confidence interval [CI], 38.0–51.8), 47.6 per 100 000 (95% CI, 40.8–54.5), and 62.0 per 100 000 (95% CI, 54.4–69.6), respectively. In idiopathic ventricular tachycardia, there was an increase in incidence rate with ages ( P <0.001) but not between sexes ( P =0.12). The age-adjusted incidence of symptomatic PVC was higher in females than in males (46.2 per 100 000 [95% CI, 40.9–51.6] versus 20.5 per 100 000 [95% CI, 16.8–24.3]; P <0.001). The small number of individuals with IVA-associated cardiomyopathy precluded any formal testing. Conclusions— The incidence of IVA is increasing. Furthermore, overall incidence increases with age. Although the rate of idiopathic ventricular tachycardia is similar across sexes, women have a higher incidence of symptomatic PVC.
Low incidence of left atrial delayed enhancement with MRI in patients with AF: a single-centre experience
Bois, John P. , Glockner, James, Young, Phillip M. , Foley, Thomas A. , Newman, Darrell B. , Lin, Grace, Packer, Douglas L. , Brady, Peter A. , Sheldon, Seth, Sheldon, Seth H.

Open Heart | January 9, 2017 | Volume: 4 | Issue: 1 | Pages: e000546

10.1136/openhrt-2016-000546 Get It

Background Atrial fibrillation (AF) is the most common sustained atrial arrhythmia. One potential target for ablation is left atrial (LA) scar (LAS) regions that may be the substrate for re-entry within the atria, thereby sustaining AF. Identification of LAS through LA delayed gadolinium enhancement (LADE) with MRI has been proposed. Objectives We sought to evaluate LADE in patients referred for catheter ablation of AF. Methods Prospective analysis was conducted of consecutive patients who underwent pulmonary vein antrum isolation (PVAI) ablation for AF at a single institution. Patients underwent LADE with MRI to determine LAS regions before ablation. MRI data were analysed independently in accordance with prespecified institutional protocol by two staff cardiac radiologists to whom patient outcomes were masked, and reports of LADE were documented. Where no initial consensus occurred regarding delayed enhancement (DE), a third staff cardiac radiologist independently reviewed the case and had the deciding vote. Results Of the 149 consecutive patients (mean (SD) age, 59 (9) years), AF was persistent in 64 (43%) and paroxysmal in 85 (57%); 45 (30%) had prior ablation. Only five patients (3%) had identifiable DE in LA walls (persistent AF, n=1; paroxysmal AF, n=4). LADE was present in two (4%) of the 45 patients with previous left PVAI. The presence of LADE was not associated with a higher recurrence rate of AF. Conclusions In contrast to previous studies, the finding of DE within LA walls was uncommon and, when present, did not correlate with AF type or risk of AF recurrence. It therefore is of unclear clinical significance.
Impact of Left Atrial Appendage Closure During Cardiac Surgery on the Occurrence of Early Postoperative Atrial Fibrillation, Stroke, and Mortality
Melduni, Rowlens M. , Lee, Hon-Chi, Bailey, Kent R. , Ammash, Naser M., Cha, Stephen S., Seward, James B., Packer, Douglas L. , Rihal, Charanjit S. , Asirvatham, Samuel J. , Fatema, Kaniz , Schaff, Hartzell V. , Gersh, Bernard J. , Noseworthy, Peter A. , Cha, Stephen S., Fatema, Kaniz , Wysokiński, Waldemar E. , Rihal, Charanjit S. , Asirvatham, Samuel J

Circulation | December 1, 2016 | Volume: 135 | Issue: 4 | Pages: 366-378

10.1161/circulationaha.116.021952 Get It

Background: Prophylactic exclusion of the left atrial appendage (LAA) is often performed during cardiac surgery ostensibly to reduce the risk of stroke. However, the clinical impact of LAA closure in humans remains inconclusive. Methods: Of 10 633 adults who underwent coronary artery bypass grafting and valve surgery between January 2000 and December 2005, 9792 patients with complete baseline characteristics, surgery procedure, and follow-up data were included in this analysis. A propensity score–matching analysis based on 28 pretreatment covariates was performed and 461 matching pairs were derived and analyzed to estimate the association of LAA closure with early postoperative atrial fibrillation (POAF) (atrial fibrillation ≤30 days of surgery), ischemic stroke, and mortality. Results: In the propensity-matched cohort, the overall incidence of POAF was 53.9%. In this group, the rate of early POAF among the patients who underwent LAA closure was 68.6% versus 31.9% for those who did not undergo the procedure ( P <0.001). LAA closure was independently associated with an increased risk of early POAF (adjusted odds ratio, 3.88; 95% confidence interval, 2.89–5.20), but did not significantly influence the risk of stroke (adjusted hazard ratio, 1.07; 95% confidence interval, 0.72–1.58) or mortality (adjusted hazard ratio, 0.92; 95% confidence interval, 0.75–1.13). Conclusions: After adjustment for treatment allocation bias, LAA closure during routine cardiac surgery was significantly associated with an increased risk of early POAF, but it did not influence the risk of stroke or mortality. It remains uncertain whether prophylactic exclusion of the LAA is warranted for stroke prevention during non–atrial fibrillation-related cardiac surgery.
Outcomes of atrial arrhythmia radiofrequency catheter ablation in patients with Ebstein’s anomaly
Hassan, Abdalla, Tan, Nicholas Y. , Aung, Htin , Connolly, Heidi M. , Hodge, David O. , Vargas, Emily , Cannon, Bryan C. , Packer, Douglas L. , Asirvatham, Samuel J. , Vargas, Emily R, McLeod, Christopher J. , Asirvatham, Samuel J

EP Europace | November 7, 2016 | Volume: 20 | Issue: 3 | Pages: 535-540

10.1093/europace/euw396 Get It