Abstract 12443: In-Beam PET Verification of Catheter-free Arrhythmia Ablation by Scanned Carbon-12 Ion Beam Irradiation
Fiedler, F. , Helmbrecht, S. , Constantinescu, A., Lugenbiel, Patrick , Prall, Matthias, Kaderka, Robert, Takami, Mitsuru , Eichhorn, Anna, Thomas, Dierk , Katus, Hugo A. , Johnson, Susan B., Parker, Kay, Asirvatham, Samuel, Packer, Douglas L. , Lehmann, H. Immo , Graeff, Christian , Prall, M. W., Richter, Daniel , Parker, Kay, Debus, Jürgen , Bert, Christoph , Durante, Marco

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.12443 Get It

Introduction: Highly precise irradiation using carbon-12 (12C) ions is a new means for catheter-free ablation. Besides energy deposition leading to the dose distribution, nuclear interactions lead to by-product β+-activity that can be measured using positron-emission-tomography (PET). Hypothesis: In-beam PET scanning during focused myocardial irradiation using 12C can adequately depict 12C dose deposition. Methods: Pigs were irradiated with 25, 40, and 55 Gy for AV node (AVN), LA-PV junction, and local LV freewall ablations. PET measurement was performed by means of a double head camera system installed at irradiation site. Coincidences were captured in end-expiration during beam extraction pauses of the accelerator. Results: Evaluation of PET images was qualitatively performed using the coronal plane of the activity distribution superimposed on the contrast-CT in the center of the target contour. Strong β+-activities were measured in AVN and LV ablations. In AVN ablations, activity was localized to the target location, without target activity spreading to the level of the aortic root or coronary sinus (Figure A). Local LV irradiations revealed strong activity in the target location, slightly extending into left lung and chest wall (Figure B). In 55 Gy animals, the cardiac entry channel showed increased activity, decreasing in 40 Gy and more so in 25 Gy animals. Conclusion: This is the first study applying in-beam PET to track 12C dose-deposition into the target location for catheter-free ablation in intact animals. Correlation of β+-activity to electrophysiological outcome, lesion induction, and potential side-effects may be critically important in dosing therapy and predicting outcomes.
ECG-based 4D-dose reconstruction of cardiac arrhythmia ablation with carbon ion beams: application in a porcine model
Eichhorn, Anna, Constantinescu, A., Kaderka, Robert, Prall, Matthias, Lugenbiel, Patrick , Takami, Mitsuru , Thomas, Dierk , Bert, Christoph , Packer, Douglas L. , Graeff, Christian , Lehmann, H. Immo , Bert, Christoph , Durante, Marco , Graeff, Christian , Richter, Daniel , Prall, M. W., Durante, Marco

Physics in Medicine & Biology | June 23, 2017 | Volume: 62 | Issue: 17 | Pages: 6869-6883

10.1088/1361-6560/aa7b67 Get It

Abstract Noninvasive ablation of cardiac arrhythmia by scanned particle radiotherapy is highly promising, but especially challenging due to cardiac and respiratory motion. Irradiations for catheter-free ablation in intact pigs were carried out at the GSI Helmholtz Center in Darmstadt using scanned carbon ions. Here, we present real-time electrocardiogram (ECG) data to estimate time-resolved (4D) delivered dose. For 11 animals, surface ECGs and temporal structure of beam delivery were acquired during irradiation. R waves were automatically detected from surface ECGs. Pre-treatment ECG-triggered 4D-CT phases were synchronized to the R – R interval. 4D-dose calculation was performed using GSI’s in-house 4D treatment planning system. Resulting dose distributions were assessed with respect to coverage ( D 95 and V 95), heterogeneity (HI = D 5– D 95) and normal tissue exposure. Final results shown here were performed offline, but first calculations were started shortly after irradiation The D 95 for TV and PTV was above 95% for 10 and 8 out of 11 animals, respectively. HI was reduced for PTV versus TV volumes, especially for some of the animals targeted at the atrioventricular junction, indicating residual interplay effects due to cardiac motion. Risk structure exposure was comparable to static and 4D treatment planning simulations. ECG-based 4D-dose reconstruction is technically feasible in a patient treatment-like setting. Further development of the presented approach, such as real-time dose calculation, may contribute to safe, successful treatments using scanned ion beams for cardiac arrhythmia ablation.