Abstract Aims Early detection of structural heart disease (SHD) improves patient outcomes. However, population-based screening is not recommended due to the lack of accurate and cost-effective tools. We evaluated the costs of artificial intelligence–enabled electrocardiogram (AI-ECG) alone vs. AI-ECG followed by handheld cardiac ultrasound (HCU) for SHD screening. Methods and results We performed a model-based cost analysis using data from 286 adult patients who underwent ECG and same-day HCU performed by a novice operator. Transthoracic echocardiogram (TTE) was the reference standard. We compared two screening strategies: (i) AI-ECG alone and (ii) a stepwise approach (AI-ECG followed by HCU). We assessed costs per diagnosis of aortic stenosis (AS), increased left ventricular wall thickness (ILVWT), and left ventricular systolic dysfunction (LVSD). Sensitivity analyses were conducted for varying disease prevalence. The stepwise approach decreased the cost per diagnosis of AS from $6386 (AI-ECG alone) to $2746 (57.0% savings), ILVWT from $4448 to $2895 (34.9% savings), and LVSD from $1469 to $1296 (11.8% savings). Overall, the cost per diagnosis for all SHDs combined decreased from $1940 to $1570 (19.1% savings). Sensitivity analysis demonstrated that cost savings were inversely proportional to disease prevalence. Nevertheless, stepwise screening remained cost-saving compared with AI-ECG alone until prevalence exceeded ∼55.9% for AS, 28.9% for ILVWT, 20.7% for LVSD, and 40.8% for all SHDs combined. Conclusion A stepwise screening strategy incorporating HCU after a positive AI-ECG reduces the immediate costs of SHD detection by minimizing unnecessary TTEs. This approach may enhance the feasibility of population-based SHD screening, particularly in lower-prevalence settings.
Echocardiography-Based, Artificial Intelligence-Enabled Electrocardiography (AI-ECG) for Diastolic Hemodynamics Phenotyping in Acute Heart Failure (AHF)
ABSTRACT Background Acute heart failure (AHF) exhibits marked heterogeneity in diastolic hemodynamics, yet comprehensive echocardiographic assessment of diastolic function (DF) and filling pressure (FP) is often infeasible. We evaluated whether artificial intelligence–enabled electrocardiography (AI-ECG) could provide scalable DF grading and FP estimation in hospitalized AHF patients. Methods We retrospectively studied adults hospitalized for AHF across Mayo Clinic sites (2013–2023) who received ≥1 dose of intravenous loop diuretic and had paired 12-lead ECG and TTE. The previously validated AI-ECG DF model was applied without retraining to generate four DF grades and a continuous FP probability. Clinical outcomes were all-cause mortality and heart failure rehospitalization. Associations with clinical severity markers and echocardiographic indices were examined. Kaplan–Meier survival analysis and adjusted multivariable Cox proportional hazards models were performed. Exploratory analyses examine the kinetics of change in FP probability and impact on mortality. Results Among 11,513 patients (median age 75 years, 39% female), AI-ECG DF grading was feasible in 100%, whereas echocardiographic DF was indeterminate in 44% of clinically eligible patients. In 2,582 patients with determinate echocardiographic DF, AI-ECG FP probability discriminated TTE Grade 2–3 dysfunction with AUC 0.85 (95% CI 0.83 – 0.86). Higher AI-ECG DF grades were associated with higher comorbidity burden, worse NYHA class, elevated NT-proBNP, higher MAGGIC scores, elevated PCWP, and more advanced structural remodeling. After multivariable adjustment, AI-ECG DF remained independently associated with mortality (hazard ratio [HR] 1.25, 95% CI 1.16–1.35 for Grade 2; HR 1.44, 95% CI 1.33–1.56 for Grade 3 versus Normal/Grade 1). Combining AI-ECG DF with MAGGIC scores yielded ordered risk gradients, with highest mortality in patients with both high MAGGIC and Grade 2–3 DF. Among patients with serial ECGs, improvement in FP probability was independently associated with lower mortality (HR 0.85, 95% CI 0.79–0.91), whereas worsening did not show a consistent adverse gradient beyond baseline DF. Conclusions In a large, geographically diverse AHF cohort, AI-ECG DF grading was universally feasible, correlated with established hemodynamic severity markers, and provided independent prognostic information beyond established risk factors, supporting its role as a pragmatic, scalable diastolic biomarker in AHF. CLINICAL PERSPECTIVE What Is New? In 11,513 hospitalized acute heart failure (HF) patients, artificial intelligence-enabled electrocardiography provided diastolic function grading in 100% of patients from a single 12-lead ECG without requiring additional clinical variables, compared with 56% feasibility for guideline-based echocardiography grading. AI-ECG diastolic function grades correlated with established marker of severity (NYHA functional class, NT-proBNP, MAGGIC risk scores, and pulmonary capillary wedge pressure) and remained independently associated with both mortality and HF rehospitalization after multivariable adjustment. Serial AI-ECG measurements identified post-discharge filling pressure trajectories, with improvement independently associated with 15% lower mortality, a first demonstration that longitudinal ECG assessment can track post-discharge hemodynamic recovery. What Are the Clinical Implications? AI-ECG transforms the universally obtained 12-lead ECG into an actionable hemodynamic biomarker that addresses the critical gap when echocardiographic diastolic function assessment is indeterminate or unavailable in acute HF patients. Despite markedly different hemodynamic severity and long-term outcomes across AI-ECG diastolic function grades, hospitalization length of stay did not differ, suggesting advanced diastolic dysfunction represents occult risk not easily recognized during routine acute care and highlighting the need for improved post-discharge risk stratification. The continuous filling pressure probability metric enables longitudinal monitoring of post-discharge hemodynamic status using serial routine ECGs, potentially identifying patients requiring intensified follow-up or specialist referral.
Higher artificial intelligence‐
ECG
atrial fibrillation prediction model output and estimated physiologic aging predict higher risk of adverse vascular events in patients with migraine
Abstract Objective To investigate the ability of artificial intelligence‐enabled electrocardiogram (AI‐ECG) atrial fibrillation (AF) prediction model output and delta age, defined as AI‐estimated age minus chronological age, to predict adverse vascular outcomes in patients with migraine. Background Migraine, especially migraine with aura, is associated with an increased risk of cardiovascular events. Using normal sinus rhythm ECG, our institution has developed AI‐ECG models that predict the probability of AF and estimate patients' age, and from that, delta age (estimated age minus actual age) has been shown to reflect cardiovascular health and physiologic aging. Methods We conducted a retrospective cohort study that included adult patients with migraine who had at least one digital, standard 12‐lead ECG from 2000 to 2020 at any Mayo Clinic site. The first normal sinus rhythm ECG was defined as the index ECG, and those with adverse vascular events or AF prior to, or within 3 days after, index ECG were excluded. AI‐ECG AF prediction model output and delta age were obtained from the index ECG. The primary outcome was a composite endpoint of adverse vascular events that included acute myocardial infarction, acute ischemic stroke, venous thromboembolism, and death. New‐onset AF was also recorded as a secondary outcome. Results A total of 29,928 patients were included. The mean age was 44.3 ± 14.5 years, and the median follow‐up time was 54 months. During the study period, 4662 (15.6%) patients had adverse vascular events, and 1384 (4.6%) patients developed new‐onset AF. A higher AF prediction model output was associated with a higher risk of adverse vascular outcomes (adjusted hazard ratio [aHR]:1.15 [95% confidence interval: 1.12 to 1.18] for every 10% increase in prediction model output), as was a larger delta age (aHR:1.16 [1.12 to 1.21] for every 10‐year increase in delta age). Moreover, AI‐ECG AF prediction model outputs of ≥1% (aHR: 1.45 [1.36 to 1.54]) and delta age ≥−1 years (aHR: 1.09 [1.02 to 1.16]) were found to be the optimal cutoffs to dichotomize patients into high‐risk and low‐risk groups for adverse vascular events. Higher AI‐ECG AF prediction model output at baseline also predicted a higher likelihood of having new‐onset AF during the study period (aHR: 1.31 [1.26 to 1.37]), and the development of new‐onset AF was associated with a higher risk of adverse vascular events (aHR: 2.43 [2.17 to 2.73]). Conclusions For patients with migraine, a higher AI‐ECG AF prediction model output and delta age are predictive of adverse vascular outcomes. A higher AF prediction model output is also predictive of future AF development. Furthermore, we identified the cutoffs for both AI‐ECG models that can distinguish patients between high‐ and low‐risk groups. Our results showed that AI‐ECG models could inform clinical practice and identify patients with migraine at risk for future adverse vascular events.
Artificial intelligence 12-lead electrocardiography to determine atrial fibrillation risk among UK Biobank participants with predisposing conditions
Abstract Aims Artificial intelligence electrocardiography (AI-ECG) algorithms are emerging tools for identifying individuals at risk of atrial fibrillation (AF). We evaluated the predictive performance of a validated AI-ECG algorithm for incident AF in UK Biobank participants with AF risk factors, irrespective of prevalent cardiovascular disease, and its incremental value when added to clinical predictors. Methods and results The AI-ECG tool was applied to sinus rhythm ECGs from UK-Biobank participants with risk factors for AF but no AF. Model performance was evaluated using time-dependent ROC-AUC and Harrell’s C-index. Multivariable Cox regression was used to identify clinical risk factors associated with incident AF and to quantify the contribution of AI-ECG. A total of 21 842 participants (56% male) were included. The median follow-up time was 3.7 years (IQR 0.5–5.4) The ECG-AI tool achieved a ROC-AUC of 0.73 (95% CI 0.68–0.78) at 1 and 0.69 (95% CI 0.66–0.72) at 3 years. A multivariable Cox regression model using clinical parameters achieved a ROC-AUC of 0.71 (95% CI 0.66–0.75) at 1 and 0.71 (95% CI 0.68–0.74) at 3 years. By adding ECG-AI to the clinical Cox regression model, the ROC-AUC increased to 0.75 (95%CI 0.71–0.80) at 1 and 0.74 (95% CI 0.71–0.77) at 3 years. AI-ECG showed a hazard ratio of 1.23 per decile increase (95% CI 1.18–1.27). Conclusion An AI-ECG algorithm improved the prediction of incident AF when added to a clinical parameter-based model over a median follow-up time of 3.7 years among individuals with comorbidities predisposing to AF who may benefit from targeted screening and preventive strategies.
Performance of a deep learning ECG model in predicting atrial fibrillation among patients with implantable loop recorders
Abstract Introduction Atrial fibrillation (AF) is a major contributor to stroke risk, yet many cases remain undiagnosed due to its silent nature. Deep learning-based electrocardiogram (DL-ECG) analysis can streamline AF risk stratification, providing a more reliable and accessible method to stratify risk using only a standard resting ECG. However, this tool has been validated only on AF detected clinically or with short ECG event monitors. Purpose This study aimed to validate the predictive accuracy of a DL-ECG model for identifying AF in normal sinus rhythm (NSR) ECGs among patients undergoing continuous cardiac monitoring with implantable loop recorders (ILRs). Methods We conducted a historical cohort study across three major U.S. academic medical centers, enrolling patients with an ILR and no prior diagnosis or documented ECG evidence of AF. Pre-implantation 10-second, 12-lead ECGs in NSR were analyzed using the DL-ECG model. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with the CHARGE-AF score. Kaplan-Meier survival analysis and Cox proportional hazards models assessed the association between DL-ECG risk categories and incident AF, defined as any episode lasting ≥6 minutes. Results We included 2,523 patients (mean age 66 ± 17 years, 52% male). AF was detected in 658 (26%) over a median follow-up of 19 months (IQR 8-37), Table 1. The DL-ECG model classified 1,634 patients (65%) as at low-risk and 889 (35%) as at high-risk. AF developed in 242 (14.8%) of the low-risk group and 416 (46.8%) of the high-risk group, yielding an AUC of 0.73 (95% CI 0.70-0.75), surpassing the CHARGE-AF AUC of 0.69 (95% CI 0.66-0.71). A combined DL-ECG and CHARGE-AF model yielded an AUC of 0.74 (95% CI 0.72-0.76), Figure 1 presents the AUC, Net Reclassification Index, and DeLong test comparisons among the three models. High-risk patients had a significantly higher incidence of AF, which remained significant after adjusting for CHARGE-AF variables, Figure 2. AF incidence increased as DL-ECG quartiles increased, with 61% of patients at the top quartile developing AF during follow-up, Figure 3. False negatives (patients initially classified as low-risk but in whom later AF was detected) had a longer median time to AF detection (127 days [IQR 28-425] vs. 101 days [IQR 20-318] for true positives, p = 0.01), and where found to have at least one positive ECG during follow-up in 36%, compared to 32% of true negatives, indicating eventual risk reclassification. Conclusions Among patients undergoing ILR monitoring, the DL-ECG model demonstrated superior predictive performance compared to CHARGE-AF, offering a promising and accessible alternative for early detection of silent AF. This approach could aid early AF detection, particularly in resource-limited settings where access to specialized rhythm monitoring services is limited.Table 1 and Figure 1 Figure 2 and 3
Assessment of diastolic function using AI-enhanced electrocardiogram and prognosis in patients with left bundle branch block
Abstract Background Left ventricular diastolic function (LVDF) and left bundle branch block (LBBB) are both linked with increased risk of LV systolic dysfunction, heart failure, and mortality. Assessing LVDF, which is typically done through echocardiography, becomes challenging in the presence of LBBB due to the intraventricular conduction delay that disrupts the reliability of tissue Doppler imaging. Recently, we validated an artificial intelligence-enabled electrocardiogram (AI-ECG) model to assess LVDF and filling pressures. Methods We performed a retrospective study among patients with ECG-confirmed LBBB who also underwent comprehensive echocardiography within 14 days of the index ECG between September 2001 and June 2022. Using multivariable survival models, we assessed the risk of all-cause mortality across AI-ECG-derived LVDF grades. Results Of 2,554 patients with LBBB (mean age 72.0+12.6, 54.6% women), 252 (9.8%), 656 (25.7%), and 1,436 (56.2%), and 210 (8.2%) had normal LVDF, G1 LVDF, G2 LVDF, and G3 LVDF, respectively. The median LV ejection fraction (LVEF) was 54% and 49.3% of the patients had heart failure. Worse LVDF was associated with older age, lower LVEF, and higher rates of diabetes, hypertension, chronic pulmonary disease, renal failure, cardiovascular disease, and heart failure (p-of-trend<0.001 for all). During a median follow-up of 2.6 years (interquartile range 0.5-4.0 years), 847 (33.2%) patients died. In multivariable survival analysis, adjusted to multiple risk factors including baseline LVEF and heart failure, worse LVDF was independently associated with a higher risk of death [G1 LVDF: adjusted hazard ratio (aHR) 2.15 (95% confidence interval (95%CI) 0.75-1.77), G2 LVDF: aHR 2.25 (95%CI 1.50-3.38) G3 LVDF: aHR 2.96 (95%CI 1.88-4.65); p<0.001 for both)]. These findings were consistent also in a subgroup of patients with baseline LVEF > 50%. Conclusion Among patients with LBBB, worse LVDF, as derived by a dedicated AI-ECG algorithm is independently associated with all-cause mortality beyond baseline LVEF and clinical heart failure.survival across AI-ECG LVDF grades
Adapting AI for 24/7 ECG monitoring: Holter-based detection of LV dysfunction
Abstract Background Artificial intelligence (AI) models trained on 12-lead ECGs effectively detect left ventricular systolic dysfunction (LVSD; left ventricular ejection fraction [LVEF] <=40%). Continuous ECG monitoring via Holter recordings provides an opportunity for opportunistic screening for structural heart disease beyond rhythm disorders. We hypothesized that a lead-invariant version of the 12-lead AI model would enable a Holter monitor to screen for both arrhythmias and ventricular dysfunction. Methods We retrospectively analyzed continuous Holter ECGs from 17,665 patients who underwent a Holter and transthoracic echocardiogram (TTE) within 30 days of each other at Mayo Clinic. From each Holter, a random 20-minute of valid (non-flatline/lead disconnect) ECG segment was extracted and analyzed for LVSD detection using the adapted lead-invariant AI model. To evaluate stability, we examined model performance across different time points of the day, presenting results as area under the receiver operating characteristic curve (AUC) over time. Moreover, we illustrated the model’s robustness to noisy data by comparing its performance on raw ECG signals with that on bandpass-filtered inputs. Results Among 17,665 patients (mean age 59 years, 48.57% female), 4.96% had an LVEF <=40%. The AI model demonstrated strong predictive performance (20-minute segment AUC 0.90, mean prediction of 24-hour AUC 0.92). Analysis of results over time (Figure) revealed temporal patterns in predictive accuracy, with specific time periods showing greater stability. Despite modest variability, model performance remained consistently high throughout the day, confirming robustness across different physiological states. The predictions remained robust with noisy input. We did not observe performance improvement when the baseline wander and high frequency noise are removed by the bandpass filter. Conclusion Applying a 12-lead AI ECG model with a lead-invariant framework to a continuous Holter ECG enables effective screening for left ventricular dysfunction. This suggests that AI-based analysis of Holter-monitors can facilitate opportunistic screening of ventricular dysfunction and may enable assessment of an arrhythmia’s impact on LVEF, as well as the relationship between arrhythmia burden and LVEF.Figure 1.Mean prediction AUC of the day Figure 2.AUC for different time point
AI-ECG-determined diastolic dysfunction in patients with STEMI
Abstract Background Left ventricular ejection fraction (LVEF) and diastolic dysfunction (DD) are key prognostic factors in patients with ST-segment elevation myocardial infarction (STEMI). AI-enabled ECG (AI-ECG) has been shown to have excellent agreement with transthoracic echocardiography (TTE) assessment and incremental prognostic value to LVEF. Methods We retrospectively analyzed 1,005 adult acute STEMI patients referred for echocardiography (10/2007–01/2025) who had ECGs within seven days before and after the reference echocardiogram. The ECG closest to the TTE date was designated as the pre-STEMI and post-STEMI ECG, respectively. AI-ECG was used to classify diastolic function grades and grades 2 and 3 were considered as DD. Patients were stratified by LVEF (≤50% vs. >50%) at the time of TTE and the association between AI-ECG-determined DD and 10-year mortality was assessed using Cox regression and Kaplan-Meier curves. Results Among 1,005 patients (mean age 66.4 ± 13.4 years, 29.9% females), AI-ECG-determined DD prior to STEMI was present in 47.9% of patients with LVEF ≤50% and 30.3% of those with preserved LVEF (>50%). DD status remained unchanged post-STEMI in 79.3% of cases, while 10.2% showed worsening diastolic function. Regardless of LVEF, AI-ECG-determined DD prior to STEMI was associated with higher mortality risk (LVEF ≤50%: HR 3.03, 95% CI 2.16–4.24, p < 0.001; LVEF >50%: HR 2.32, 95% CI 1.58–3.41, p < 0.001). Post STEMI AI-ECG-determined DD remained a significant predictor of mortality (LVEF ≤50%: HR 2.54, 95% CI 1.82–3.53, p < 0.001; LVEF >50%: HR 2.43, 95% CI 1.66–3.58, p < 0.001). Echocardiographically determined DD also correlated with higher mortality (LVEF ≤50%: HR 4.91, 95% CI 2.95–8.15, p < 0.001; LVEF >50%: HR 2.72, 95% CI 1.68–4.41, p < 0.001). In patients with LVEF ≤50%, AI-ECG-determined DD remained associated with higher mortality even after adjusting for echocardiographically determined DD (pre-STEMI: HR 1.85, 95% CI 1.23–2.80, p < 0.001; post-STEMI: HR 1.90, 95% CI 1.23–2.91, p < 0.001). Conclusion AI-ECG-determined DD is a significant predictor of mortality in STEMI, independent of LVEF. The presence of normal filling pressure may indicate a better clinical outcome in patients with reduced LVEF patients. These findings underscore the clinical utility of AI-ECG in refining risk stratification beyond conventional LVEF assessment.
Extravascular Implantable Cardioverter Defibrillator (EV-ICD) therapy in patients with genetic heart disease: a single center experience
Abstract Background The extravascular implantable cardioverter defibrillator (EV-ICD) was designed to avoid lead-related complications associated with transvenous systems and deliver features such as anti-tachycardia pacing (ATP) and reduced generator size that provide an advantage over a subcutaneous ICD (S-ICD). As such, the EV-ICD is an attractive alternative for younger patients with genetic heart diseases (GHDs) who are not in need of permanent pacing. Objective To examine the indications, complications, and the clinical outcomes of patients with GHDs who received an EV-ICD. Methods A retrospective review of the electronic record was done for all GHD patients evaluated in genetic heart rhythm and/or cardiomyopathy clinics who had an EV-ICD implanted between 1/2021 and 2/2025. Basic demographic, ICD indications, complications, and therapy data were then extracted for all study patients. Results Overall, 23 patients (35% female; mean age 39 ± 16 years; 61% with a disease-causative genetic variant; mean LVEF 57%) with an underlying GHD (hypertrophic cardiomyopathy in 9, arrhythmogenic cardiomyopathy in 8, idiopathic ventricular fibrillation in 3, dilated cardiomyopathy in 2, and long QT syndrome in 1) had an EV-ICD implanted. For the majority, an EV-ICD was implanted for primary prevention (15/23; 65%) and represented their first ICD system (21/23; 91%). The success rate of the procedure was 96% with only one abandoned procedure because of poor R-wave sensing. Inadvertent intraprocedural lead placement in the pericardial space occurred in 1 patient with previous thoracotomy and surgically placed epicardial lead without sequelae or need for revision. Over a mean follow-up of 8±9 months, the rate of complications was low (1/23; 4%) with one electrode displacement and this patient underwent defibrillation threshold testing (DFT), the device properly detected VF and emitted a successful shock 30 J. Thus far, 2 patients have received appropriate VT/VF-terminating therapies (3 ICD shocks, 0 ATP) with successful conversion to sinus rhythm. One patient died following an electrical storm. One patient had 3 inappropriate ICD shock for sinus tachycardia while exercising followed by 1 successful shock for VF. Conclusion In this early experience, EV-ICDs appear to be safe and effective in younger patients with genetic arrhythmogenic and hypertrophic cardiomyopathies. Future studies are needed to better understand the utility of EV-ICDs in patients with cardiac channelopathies and advantages of EV-ICDs over transvenous and S-ICD systems in patients with an array of sudden death-predisposing GHDs.
Deep learning for estimating right ventricular function from routine coronary angiography
Abstract Aims Coronary angiography might contain clinically relevant information, beyond its traditional role in delineating coronary artery disease. We sought to explore the role of deep learning (DL) in detecting right ventricular dysfunction from routinely acquired cine images during coronary angiography. Methods and results 3D-convolutional neural networks (CNN) were trained to identify right ventricle (RV) dysfunction from diagnostic angiography of the right coronary artery (RCA). The model’s input was two cine angiograms from LAO and RAO projections. The model’s output was normal vs. abnormal RV function. Ground truth on RV function was obtained from the nearest transthoracic echocardiogram to the coronary angiogram. Two analyses were performed to identify (i) any RV dysfunction (≥mild) and (ii) significant RV dysfunction (≥mild–moderate). A total of 10 336 coronary angiograms from 9849 patients (mean age 66, 36% women) were included. The cohort was split into training (70%), validation (15%), and testing (15%) sets. In the testing sets, the models attained an area under the ROC curve (AUC), sensitivity, and specificity of 0.82 (95% CI: 0.80–0.84), 0.75, and 0.74, for detecting any RV dysfunction, and 0.83 (95% CI: 0.80–0.86), 0.82, and 0.70 for detecting significant (≥mild–moderate) RV dysfunction. Combining an ECG-driven AI model with the angio-driven model improved the AUC values to 0.83 and 0.87 for detecting any or advanced RV dysfunction, respectively. Conclusion A novel deep learning algorithm yielded acceptable classification accuracy in detecting RV dysfunction from routine cine angiography of the RCA. The model’s performance improved further by adding ECG to its inputs.