Background Complications of endoscopic mucosal resection (EMR) of large colorectal polyps remain a concern. Objective We aimed to compare safety and efficacy of cold EMR (without electrocautery) to hot EMR (with electrocautery) of large colorectal polyps. Design In this multicentre randomised trial, patients with any large (≥20 mm) non-pedunculated colon polyp were assigned to cold or hot EMR (primary intervention), and to submucosal injection with a viscous or non-viscous solution (secondary intervention) following a 2×2 design. The primary outcome was the rate of severe adverse events (SAEs). The secondary outcome was polyp recurrence. In this study, we report results of the primary intervention. Results 660 patients were randomised and analysed. An SAE was observed in 2.1% of patients in the cold EMR group and in 4.3% in the hot EMR group (p=0.10) (per protocol analysis 1.4 vs 5.0%, p=0.017) with fewer perforations following cold EMR (0%) compared with hot EMR (1.6%, p=0.028). Postprocedure bleeding did not differ (1.5% vs 2.2%, p=0.57). The effect of cold resection was independent of the type of submucosal injection solution, polyp size or antithrombotic medications. Recurrence was detected in 27.6% and 13.6% in the cold and hot EMR groups, respectively (p<0.001). Recurrence was not significantly different for 20–29 mm polyps (18.6% vs 13.4%, p=0.24) and for sessile serrated polyps (14.1% vs 8.5%, p=0.33). Conclusion Universal application of cold EMR did not significantly lower SAEs (unless cold EMR could be completed) and doubled the recurrence rate compared with hot EMR. Trial registration details ClinicalTrials.gov, number: NCT03865537 .
Comparable long-term efficacy of cold and hot EMR of large colon polyps – follow up results of a randomized trial
AbstractEUS-guided gallbladder drainage (EUS-GBD) using lumen apposing metal stents (LAMS) has excellent technical and short-term clinical success for acute cholecystitis (AC). The goals of this study were to determine the long-term clinical outcomes and adverse events (AEs) of EUS-GBD with LAMS.A multicenter, retrospective study was conducted at 18 US tertiary care institutions. Inclusion criteria: any AC patient with attempted EUS-GBD with LAMS and minimum 30-day post-procedure follow-up. Long-term clinical success was defined as absence of recurrent acute cholecystitis (RAC) > 30 days and long-term AE was defined as occurring > 30 days from the index procedure.A total of 109 patients were included. Technical success was achieved in 108 of 109 (99.1%) and initial clinical success in 106 of 109 (97.2%). Long-term clinical success was achieved in 98 of 109 (89.9%) over a median follow-up of 140 days (range 30–1188). On multivariable analysis (MVA), acalculous cholecystitis (odds ratio [OR] 15.93, 95% confidence interval [CI] 1.22–208.52, P = 0.04) and the occurrence of a LAMS-specific AE (OR 63.60, 95% CI 5.08–799.29, P <0.01) were associated with RAC. AEs occurred in 38 of 109 patients (34.9%) at any time, and in 10 of 109 (9.17%) > 30 days from the index procedure. Most long-term AEs (7 of 109; 6.42%) were LAMS-specific. No technical or clinical factors were associated with occurrence of AEs. LAMS were removed in 24 of 109 patients (22%). There was no difference in RAC or AEs whether LAMS was removed or not.EUS-GBD with LAMS has a high rate of long-term clinical success and modest AE rates in patients with AC and is a reasonable destination therapy for high-risk surgical candidates.
Cold snare endoscopic resection for large colon polyps – a randomized trial
Background Delayed bleeding is among the most common adverse events associated with endoscopic mucosal resection (EMR) of nonampullary duodenal polyps. We evaluated the rate of delayed bleeding and complete defect closure using a novel through-the-scope (TTS) suturing system for the closure of duodenal EMR defects. Methods We reviewed the electronic medical records of patients who underwent EMR for nonampullary duodenal polyps of ≥ 10 mm and prophylactic defect closure with TTS suturing between March 2021 and May 2022 at centers in the USA. We evaluated the rates of delayed bleeding and complete defect closure. Results 36 nonconsecutive patients (61 % women; mean [SD] age, 65 [12] years) underwent EMR of ≥ 10-mm duodenal polyps followed by attempted defect closure with TTS suturing. The mean (SD) lesion size was 29 (19) mm, defect size was 37 (25) mm; eight polyps (22 %) involved > 50 % of the lumen circumference. Complete closure was achieved in all cases (78 % with TTS suturing alone), using a median of one TTS suturing kit. There were no cases of delayed bleeding and no adverse events attributed to application of the TTS suturing device. Conclusion Prophylactic closure of nonampullary duodenal EMR defects using TTS suturing resulted in a high rate of complete closure and no delayed bleeding events.
Endoscopic submucosal dissection for colorectal dysplasia in inflammatory bowel disease: a US multicenter study
Abstract Background and study aims In patients with inflammatory bowel disease (IBD), endoscopically visible lesions with distinct borders can be considered for endoscopic resection. The role of endoscopic submucosal dissection (ESD) for these lesions is not well defined because of a paucity of data. We aimed to evaluate the outcomes of colorectal ESD of dysplastic lesions in patients with IBD across centers in the United States. Patients and methods This was a retrospective analysis of consecutive patients with IBD who were referred for ESD of dysplastic colorectal lesions at nine centers. The primary endpoints were the rates of en bloc resection and complete (R0) resection. The secondary endpoints were the rates of adverse events and lesion recurrence. Results A total of 45 dysplastic lesions (median size 30mm, interquartile range [IQR] 23 to 42 mm) in 41 patients were included. Submucosal fibrosis was observed in 73 %. En bloc resection was achieved in 43 of 45 lesions (96 %) and R0 resection in 34 of 45 lesions (76 %). Intraprocedural perforation occurred in one patient (2.4 %) and was treated successfully with clip placement. Delayed bleeding occurred in four patients (9.8 %). No severe intraprocedural bleeding or delayed perforation occurred. During a median follow-up of 18 months (IQR 13 to 37 months), local recurrence occurred in one case (2.6 %). Metachronous lesions were identified in 11 patients (31 %). Conclusions ESD, when performed by experts, is safe and effective for large, dysplastic colorectal lesions in patients with IBD. Despite the high prevalence of submucosal fibrosis, en bloc resection was achieved in nearly all patients with IBD undergoing ESD. Careful endoscopic surveillance is necessary to monitor for local recurrence and metachronous lesions after ESD.
First interobserver agreement of optical coherence tomography in the bile duct: A multicenter collaborative study
Abstract Background and study aims Optical coherence tomography (OCT) is a new technology available for evaluation of indeterminate biliary strictures. It allows under-the-surface visualization and preliminary studies have confirmed standardized characteristics associated with malignancy. The aim of this study is to evaluate the first interobserver agreement in identifying previously agreed upon OCT criteria and diagnosing of malignant versus benign disease. Patients and methods Fourteen endoscopists were asked to review an atlas of reference clips and images of eight criteria derived from expert consensus A total of 35 de-identified video clips were then evaluated for presence of the eight criteria and for final diagnosis of malignant versus benign using the atlas as reference Intraclass correlation (ICC) analysis was done to evaluate interrater agreement. Results Clips of 23 malignant lesions and 12 benign lesions were scored. Excellent interobserver agreement was seen with dilated hypo-reflective structures (0.85) and layering effacement (0.89); hyper-glandular mucosa (0.76), intact layering (0.81), and onion-skin layering (0.77); fair agreement was seen with scalloping (0.58), and thickened epithelium (0.4); poor agreement was seen with hyper-reflective surface (0.36). The diagnostic ICC for both neoplastic (0.8) and non-neoplastic (0.8) was excellent interobserver agreement. The overall diagnostic accuracy was 51 %, ranging from 43 % to 60 %. Conclusions Biliary OCT is a promising new modality for evaluation of indeterminate biliary strictures. Interobserver agreement ranged from fair to almost perfect on eight previously identified criteria. Interobserver agreement for malignancy diagnosis was substantial (0.8). Further studies are needed to validate this data.
Endoscopic resection outcomes and predictors of failed en bloc endoscopic mucosal resection of colorectal polyps ≤ 20 mm among advanced endoscopy trainees
Abstract Background and study aims En bloc endoscopic mucosal resection (EMR) is preferred over piecemeal resection for polyps ≤ 20 mm. Data on colorectal EMR training are limited. We aimed to evaluate the en bloc EMR rate of polyps ≤ 20 mm among advanced endoscopy trainees and to identify predictors of failed en bloc EMR. Methods This was a multicenter prospective study evaluating trainee performance in EMR during advanced endoscopy fellowship. A logistic regression model was used to identify the number of procedures and lesion cut-off size associated with an en bloc EMR rate of ≥ 80 %. Multivariate analysis was performed to identify predictors of failed en bloc EMR. Results Six trainees from six centers performed 189 colorectal EMRs, of which 104 (55 %) were for polyps ≤ 20 mm. Of these, 57.7 % (60/104) were resected en bloc. Trainees with ≥ 30 EMRs (OR 6.80; 95 % CI: 2.80–16.50; P = 0.00001) and lesions ≤ 17 mm (OR 4.56;95 CI:1.23–16.88; P = 0.02) were more likely to be associated with an en bloc EMR rate of ≥ 80 %. Independent predictors of failed en bloc EMR on multivariate analysis included: larger polyp size (OR:6.83;95 % CI:2.55–18.4; P = 0.0001), right colon location (OR:7.15; 95 % CI:1.31–38.9; P = 0.02), increased procedural difficulty (OR 2.99; 95 % CI:1.13–7.91; P = 0.03), and having performed < 30 EMRs (OR: 4.87; 95 %CI: 1.05–22.61; P = 0.04). Conclusions In this pilot study, we demonstrated that a relatively low proportion of trainees achieved en bloc EMR for polyps ≤ 20 mm and identified procedure volume and lesion size thresholds for successful en bloc EMR and independent predictors for failed en bloc resection. These preliminary results support the need for future efforts to define EMR procedure competence thresholds during training.
S1046 Predicting Histological Diagnosis After Endoscopic Submucosal Dissection With Demographic Characteristics and Endoscopic Lesion Characteristics: An Analysis of a Large Cohort in North America