Back to Authors

Kapa, Suraj

https://orcid.org/0000-0003-2283-4340

Mayo Clinic

Mayo Clinic

Citations 124

Abstract 17152: Artificial Intelligence ECG for the Detection of Cardiac Injury as Confirmed by High Sensitivity Cardiac Troponin T-Concentrations
Sandoval, Yader , Jaffe, Allan S. , Friedman, Paul A. , Attia, Zachi I. , Carter, Rickey E. , Kapa, Suraj , López-Jiménez, Francisco , Noseworthy, Peter A. , Jaffe, Allan S.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.17152 Get It

Background: High-sensitivity cardiac troponin (hs-cTn) assays quantify cTn in patients at very low concentrations. Myocyte injury due to ischemia or other pathologies cause blood levels to increase, which is prognostic. A noninvasive, rapid, broadly available, home-based test to detect hs-cTn increases would facilitate risk-stratification. Since myocyte injury is associated with ECG changes, we hypothesized an artificial intelligence ECG (AI-ECG) could non-invasively predict current or impending hs-cTnT elevations. Objective: To develop an AI-ECG convolutional neural network (CNN) to detect an abnormal hs-cTnT (5 th Gen cTnT, Roche Diagnostics) concentration using a 12-lead ECG, and a single lead ECG (lead I), which would enable smartphone, home-based detection. Methods: We developed single lead and 12-lead ECG CNNs to detect a) hs-cTnT concentrations that were at or above the 6ng/L limit that can be reported b) above the 99 th percentile upper limits of >15ng/L for men and >10ng/L for women. All ECGs were recorded within one hour of the hs-cTnT measurements. We used 73,012 ECG and hs-cTnT pairs from 47,542 unique patients to train the network, 9031 ECGs from 5,811 patients for internal validation to optimize hyperparameters, and 18,276 ECG and hs-cTnT pairs from 11,904 different patients as a holdout test set to determine the area under the receiver-operator curve (AUC). Results: The mean age was 63.9±17.5 years, and 30,348 of the 59,446 patients (51%) were male. Of the 91,288 hs-cTnT pairs 73,271 (80.2%) were above 6ng/L and 50,799 (55.6%) are above the 99 th percentile. In the test set, the AUC for the detection of a hs-cTnT level higher than 6ng/L was 0.88 using the 12 lead ECG and 0.834 with the single lead. For the detection of hs-cTnT level above of 99 th percentile, the 12 lead ECG AUC was 0.853 and the single lead was 0.806. Conclusion: The AI-ECG permits detection of levels of hs-cTnT consistent with myocardial injury. This may allow a home-based, non-invasive test that would be massively scalable and could further enhance rapid-risk stratification and patient triage with potentially significant cost reductions and enable novel triage strategies at sites without hs-cTn assays.
Abstract 16741: A Comparison of High versus Conventional Power Radiofrequency Catheter Ablation for Pulmonary Vein Isolation: A Systematic Review and Meta-Analysis
Amin, Mustapha, Nayfeh, Tarek , Nanaa, Ahmad , Saadi, Samer , Killu, Ammar M. , Madhavan, Malini , Mulpuru, Siva K. , Deshmukh, Abhishek , Nayfeh, Tarek , Saadi, Samer , Kapa, Suraj , DeSimone, Christopher V.

Circulation | November 12, 2020 | Volume: 142 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.142.suppl_3.16741 Get It

Objectives: We sought to evaluate the procedural safety and outcomes of high power (HP) versus conventional power (CP) radiofrequency (RF) ablation during pulmonary vein isolation (PVI). Methods: A systematic search was used via MEDLINE, EMBASE, and Cochrane databases between 01/1998 and 05/2020 for studies comparing the safety and efficacy between HP and CP during RF ablation for PVI using contact-force catheters (ThermocoolSmartTouch or TactiCath). The search terms used were “AF” AND “catheter ablation” OR “radiofrequency ablation”. Results: From eight comparative observational studies, we developed a cohort of 992 patients (478 in the HP and 514 in the CP group). The median maximum energy output used in the HP group was 50W vs 35W in the CP group. There was a statistically significant difference noted in acute pulmonary vein reconnection (APVR) in the HP group compared to the CP groups at16% vs 32.6%, respectively (RR: 0.53, 95% CI: 0.33 - 0.86, P = 0.01). Freedom from arrhythmia at 12 months follow-up was also significant and found to be 87.8% of cases in the HP group versus75.2% of cases in the CP group (RR: 0.46, 95%CI: 0.32 - 0.65, P <0.01). The mean RF ablation time was 20.1 minutes in the HP group vs 39.6 minutes in the CP group (P <0.01). The mean total procedural time was 103.5 minutes in the HP group compared to 135 minutes in the CP group (P <0.01). Two patients in the CP group experienced severe adverse events (1 cardiac tamponade and 1 myocardial infarction). No serious AEs were found in the HP group. Non-serious AEs (groin complications, pericardial effusion, and phrenic nerve injury) were reported in 0.35% and 0.51% of cases in the HP and CP group, respectively. Conclusion: This study suggests that HP PVI ablation can be associated with better ablation outcomes by reducing the rate of acute and late PV reconnection and atrial arrhythmia recurrence, with similar safety profiles, and shorter procedural times. These findings merit evaluation in a randomized controlled trial.
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Kuzmenko, Volodymyr , Sämfors, Sanna, Livia, Christopher , Vaidya, Vaibhav R. , Sugrue, Alan , Behfar, Atta , Asirvatham, Samuel J. , Gatenholm, Paul , Kapa, Suraj , van Zyl, Martin , Livia, Christopher , Vaidya, Vaibhav , Sugrue, Alan , Asirvatham, Samuel J , Gatenholm, Paul , Kapa, Suraj , Behfar, Atta , Karabulut, Erdem , McLeod, Christopher J.

Journal of Cardiovascular Electrophysiology | September 23, 2020 | Volume: 31 | Issue: 12 | Pages: 3293-3301

10.1111/jce.14762 Get It

AbstractIntroductionTherapies for substrate‐related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization.MethodsA nanocellulose carbon nanotube‐conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue.ResultsThe conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The direct current conductivity under aqueous conduction was 4.3 × 10−1 S/cm. In four canine hearts, when compared with the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of the conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation restored through the ablated tissue. Gross specimen examination demonstrated retention of the hydrogel within the tissue.ConclusionsThis proof‐of‐concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long‐term retention and biocompatibility of the hydrogel through in vivo experimentation.
Mortality in Patients With Right Bundle‐Branch Block in the Absence of Cardiovascular Disease
Gaba, Prakriti , Pedrotty, Dawn , Bonikowske, Amanda R. , Allison, Thomas G. , Bonikowske, Amanda , DeSimone, Christopher V. , Kapa, Suraj

Journal of the American Heart Association | September 14, 2020 | Volume: 9 | Issue: 19 | Pages: No page available

10.1161/jaha.120.017430 Get It

Background Right bundle‐branch block (RBBB) occurs in 0.2% to 1.3% of people and is considered a benign finding. However, some studies have suggested increased risk of cardiovascular morbidity and mortality. We sought to evaluate risk attributable to incidental RBBB in patients without prior diagnosis of cardiovascular disease (CVD). Methods and Results We reviewed the Mayo Clinic Integrated Stress Center database for exercise stress tests performed from 1993 to 2010. Patients with no known CVD—defined as absence of coronary disease, structural heart disease, heart failure, or cerebrovascular disease—were selected. Only Minnesota residents were included, all of whom had full mortality and outcomes data. There were 22 806 patients without CVD identified; 220 of whom (0.96%) had RBBB, followed for 6 to 23 years (mean 12.4±5.1). There were 8256 women (36.2%), mean age was 52±11 years; and 1837 deaths (8.05%), including 645 cardiovascular‐related deaths (2.83%), occurred over follow‐up. RBBB was predictive of all‐cause (hazard ratio [HR], 1.5; 95% CI, 1.1–2.0; P =0.0058) and cardiovascular‐related mortality (HR,1.7; 95% CI, 1.1–2.8; P =0.0178) after adjusting for age, sex, diabetes mellitus, hypertension, obesity, current and past history of smoking, and use of a heart rate‐lowering drug. Patients with RBBB exhibited more hypertension (34.1% versus 23.7%, P <0.0003), decreased functional aerobic capacity (82±25% versus 90±24%; P <0.0001), slower heart rate recovery (13.5±11.5 versus 17.1±9.4 bpm; P <0.0001), and more dyspnea (28.2% versus 22.4%; P <0.0399) on exercise testing. Conclusions Patients with RBBB without CVD have increased risk of all‐cause mortality, cardiovascular‐related mortality, and lower exercise tolerance. These data suggest RBBB may be a marker of early CVD and merit further prospective evaluation.
Natural History of Patients Diagnosed with Cardiac Sarcoidosis at Left Ventricular Assist Device Implantation or Cardiac Transplantation
Schmidt, Tyler , Rosenbaum, Andrew , Kolluri, Nikhil , Stulak, John M., Daly, Richard C. , Schirger, John A., Elwazir, Mohamed Y. , Kapa, Suraj , Blauwet, Lori A., Schmidt, Tyler J , Rosenbaum, Andrew N , Kapa, Suraj , Elwazir, Mohamed , Cooper, Leslie T.

ASAIO Journal | September 6, 2020 | Volume: 67 | Issue: 5 | Pages: 583-587

10.1097/mat.0000000000001262 Get It

To our knowledge, natural history has not been reported for cardiac sarcoidosis (CS) diagnosed by pathologic evaluation of the apical core at left ventricular assist device (LVAD) implantation or cardiac transplantation. We retrospectively identified 232 consecutive patients meeting CS criteria. Of these patients, 54 were diagnosed by pathologic confirmation of CS, 10 after evaluation of the apical core (LVAD implant) or explanted heart (transplant). We compared clinical characteristics at initial evaluation and outcomes for these 10 patients with those of 10 patients with known CS before LVAD implant/transplant. In the study group, five patients (50%) had confirmed extracardiac sarcoidosis before LVAD implant/transplant; five had not been diagnosed with sarcoidosis. Mean (standard deviation) left ventricular ejection fraction at initial evaluation was 23% (16%), and left ventricular end-diastolic dimension was 61 (10) mm. Four patients died during follow-up; however, no survival difference was found for the 10 patients diagnosed incidentally and the group with a previous diagnosis or institutional LVAD/transplant cohorts. Patients diagnosed with CS on pathological examination of the apical core/explanted heart may have severe dilated cardiomyopathy as the initial presentation. Outcomes for patients with CS after advanced heart failure therapies may be comparable with those of non-CS patients.
Utilization and procedural adverse outcomes associated with Watchman device implantation
Khalil, Fouad , Arora, Shilpkumar , Killu, Ammar M. , Egbe, Alexander C. , Kapa, Suraj , Mulpuru, Siva K. , Mohamad, Alkhouli, Friedman, Paul A. , Holmes, David R. , Deshmukh, Abhishek , Mulpuru, Siva, Khalil, Fouad , Kapa, Suraj , Tripathi, Byomesh , DeSimone, Christopher V. , Noseworthy, Peter A. , Gersh, Bernard J.

EP Europace | August 9, 2020 | Volume: 23 | Issue: 2 | Pages: 247-253

10.1093/europace/euaa219 Get It

AbstractAims The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies.Methods and results The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code—02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively.Conclusion Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.
Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
Artificial Intelligence and Machine Learning in Arrhythmias and Cardiac Electrophysiology
Feeny, Albert , Chung, Mina K. , Attia, Zachi I. , Čikeš, Maja , Firouznia, Marjan , Friedman, Paul A. , Kalscheur, Matthew M. , Narayan, Sanjiv M. , Piccini, Jonathan P. , Tarakji, Khaldoun G. , Thomas, Suma A., Turakhia, Mintu P. , Wang, Paul J. , Attia, Zachi I , Kalscheur, Matthew M , Turakhia, Mintu P , Narayan, Sanjiv M , Madabhushi, Anant , Kapa, Suraj , Noseworthy, Peter A. , Passman, Rod , Pérez, Marco , Peters, Nicholas Simon , Trayanova, Natalia A.

Circulation: Arrhythmia and Electrophysiology | July 6, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circep.119.007952 Get It

Artificial intelligence (AI) and machine learning (ML) in medicine are currently areas of intense exploration, showing potential to automate human tasks and even perform tasks beyond human capabilities. Literacy and understanding of AI/ML methods are becoming increasingly important to researchers and clinicians. The first objective of this review is to provide the novice reader with literacy of AI/ML methods and provide a foundation for how one might conduct an ML study. We provide a technical overview of some of the most commonly used terms, techniques, and challenges in AI/ML studies, with reference to recent studies in cardiac electrophysiology to illustrate key points. The second objective of this review is to use examples from recent literature to discuss how AI and ML are changing clinical practice and research in cardiac electrophysiology, with emphasis on disease detection and diagnosis, prediction of patient outcomes, and novel characterization of disease. The final objective is to highlight important considerations and challenges for appropriate validation, adoption, and deployment of AI technologies into clinical practice.
Injectable conductive hydrogel restores conduction through ablated myocardium
Zyl, Martin van , Pedrotty, Dawn , Karabalut, Erdem, mfors, Sanna S, Livia, Chris, Vaidya, Vaibhav R. , Sugrue, Alan , Gatenholm, Paul , Kuzmenko, Volodymyr , Livia, Christopher , McLeod, Christopher J. , Behfar, Atta , Asirvatham, Samuel J. , Kapa, Suraj

No container title available | July 6, 2020 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.159406900.02369826 Get It

Abstract Introduction: Therapies for substrate-related arrhythmias include ablation or drugs targeted at altering conductive properties or disruption of slow zones in heterogeneous myocardium. Conductive compounds such as carbon nanotubes may provide a novel personalizable therapy for arrhythmia treatment by allowing tissue homogenization. Methods: A nanocellulose-carbon nanotube conductive hydrogel was developed to have conduction properties similar to normal myocardium. Ex vivo perfused canine hearts were studied. Electroanatomic activation mapping of the epicardial surface was performed at baseline, after radiofrequency ablation, and after uniform needle injections of the conductive hydrogel through the injured tissue. Gross histology was used to assess distribution of conductive hydrogel in the tissue. Results: The conductive hydrogel viscosity was optimized to decrease with increasing shear rate to allow expression through a syringe. The DC conductivity under aqueous conduction was 4.3·10-1 S/cm. In 4 canine hearts, when compared to the homogeneous baseline conduction, isochronal maps demonstrated sequential myocardial activation with a shift in direction of activation to surround the edges of the ablated region. After injection of conductive hydrogel, isochrones demonstrated conduction through the ablated tissue with activation similar to baseline in all 4 hearts. Gross specimen examination demonstrated retention of the hydrogel within the tissue. Conclusions: This proof-of-concept study demonstrates that conductive hydrogel can be injected into acutely disrupted myocardium to restore conduction. Future experiments should focus on evaluating long-term retention and biocompatibility of the hydrogel through in vivo experimentation.
An artificial intelligence-enabled analysis of ECG changes after androgen deprivation therapy (ADT) for prostate cancer.
Breen, William G. , Herrmann, Joerg , Friedman, Paul D., Attia, Zachi Itzhak, Stish, B.J., Carter, Rickey E. , Johnson, Patrick W. , Routman, David M. , Noseworthy, Peter A. , Friedman, Paul, López-Jiménez, Francisco , Attia, Zachi I. , Kapa, Suraj

Journal of Clinical Oncology | May 25, 2020 | Volume: 38 | Issue: 15_suppl | Pages: e17535-e17535

10.1200/jco.2020.38.15_suppl.e17535 Get It

e17535 Background: Androgen Deprivation Therapy (ADT) is commonly used to treat prostate cancer (PC), but has been associated with cardiac morbidity and mortality. The exact mechanisms of this association are unclear. We sought to use an artificial intelligence (AI) enabled algorithm to identify ECG changes in PC patients who received ADT compared to PC patients who did not receive ADT. Methods: From 1,000,000 ECGs performed on 210,414 patients between 1993 and 2017 at our institution, a convolutional neural network was developed to detect predictive signatures for cardiac pathologies. During this process, the ability to predict “estimated sex” of the patient was developed, with output values ranging from 0 (female) to 1 (male). We applied this algorithm to 8,619 ECGs performed on 1,057 men age 75 or younger treated with radiation for high-risk or recurrent PC at our institution, and compared estimated sex after receiving ADT (n = 1,065) to ADT-naive ECGs (n = 7,554). We correlated ECG-identified estimated sex with serum testosterone levels using Spearman rank correlation. Results: Patients who had received ADT had a mean (SD) estimated sex value of 0.81 (0.26) compared to 0.92 (0.17) for those who did not (p < 0.001). Difference between estimated sex in post-ADT ECGs and ADT-naive ECGs remained significant across age groups (Table). Decreased serum total testosterone correlated with decreased estimated sex values in men receiving ADT (R = .57, p < 0.001). Conclusions: ADT for prostate cancer is associated with changes in AI-identified ECG parameters, including lower estimated male sex after receiving ADT. Lower ECG male sex estimate was associated with decreased serum testosterone. In this study, we provide preliminary proof of concept for a potential non-invasive means of monitoring treatment effect and physiologic change using ECGs. [Table: see text]