Citations

Clear

24 citation(s) found for "Rodriguez-Riascos, J".

Serial Artificial Intelligence ECG-Derived Atrial Fibrillation Probability and Recurrence Risk After Pulsed Field Ablation
Sardana, Mayank , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Kim, James , Attia, Zachi I , Wood, Julia , Mangold, Kathryn E , Friedman, Paul A , Noseworthy, Peter A , Srivathsan, Komandoor

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | October 8, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circep.126.015183 | PMID 42845233 Get It

BACKGROUND: Pulsed field ablation is now widely used for atrial fibrillation (AF) ablation, but atrial tachyarrhythmia recurrence remains common and postablation risk tools are limited. We assessed whether a validated sinus‑rhythm artificial intelligence— enabled ECG AF probability score, and its early postablation change, predicts recurrence after pulsed field ablation. METHODS: We studied consecutive patients undergoing index pulsed field ablation across 3 Mayo Clinic sites (February 2024–March 2025) with ≥1 sinus‑rhythm ECG within 180 days preprocedure. Baseline artificial intelligence—enabled ECG AF score (range 0–1) was the mean across baseline ECGs. Recovery indices (RI30/60/90), defined as mean postprocedure artificial intelligence—enabled ECG score within days 1–30/60/90 minus baseline, predicted post‑blanking recurrence using corresponding 30‑, 60‑, and 90‑day blanking windows. The primary outcome was time to first documented AF/atrial flutter/atrial tachycardia episode >30 seconds, ascertained via clinic ECGs, ambulatory monitoring, and device interrogations. Cox regression adjusted for prespecified clinical and echocardiographic covariates assessed associations; Harrell C‑statistic quantified discrimination. RESULTS: Among 1052 patients (67±10 years; 33% women), median baseline score was 0.35; 320 (30%) recurred over 188 days. Higher baseline score independently predicted recurrence (hazard ratio per 0.1 increase, 1.08 [95% CI, 1.03–1.14]). Scores rose on day 0 after ablation, then declined over subsequent weeks, with persistently higher, less‑improving trajectories among patients who recurred (time×recurrence interaction P <0.001). Day 0 score was not independently associated with recurrence after adjustment. Attenuated early recovery (higher recovery index) was independently associated with recurrence, most robustly for RI-90 (hazard ratio per 0.1 increase, 1.15 [95% CI, 1.07–1.24]), and improved discrimination beyond baseline and covariates (C‑statistic, 0.63–0.67; ΔC=0.04). Findings were consistent in a historical thermal ablation cohort. CONCLUSIONS: Baseline and early postablation dynamics of a sinus‑rhythm artificial intelligence—enabled ECG AF probability score are associated with pulsed field ablation recurrence and may aid multivariable risk stratification; prospective validation is warranted.
Atrial Fibrillation in Patients With Pectus Excavatum: Clinical Characteristics, Management, and Outcomes
Habib, Eiad , Mohammed, Arshad , Gotway, Michael B , Wallace, Alyssa, Abdul Nabi, Hussein , Rodriguez-Riascos, Juan F , Youssef, Amal , Koepke, Laura, Odeh, Nour , Villa Etchegoyen, Cecilia , Abdelnabi, Mahmoud , Senjab, Abdulrahman , Farina, Juan María, Sorajja, Dan , El Masry, Hicham , Jaroszewski, Dawn, Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | October 6, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/pace.70462 | PMID 42834350 Get It

ABSTRACT Background Pectus excavatum (PE), the most common congenital chest wall deformity, has known associations with connective tissue disorders and may lead to cardiopulmonary impairment; however, its relationship with atrial fibrillation (AF) remains underexplored. Objectives This study aimed to describe the frequency, clinical characteristics, and management of AF within an institutional cohort of patients with PE, and to determine whether the outcomes observed in clinically distinct subgroups persisted after adjustment for baseline risk. Methods This was a retrospective cohort study design. Patients with both PE and documented AF between January 1, 1990, and November 10, 2024, were included. Clinical, echocardiographic, and therapeutic data were collected. Bleeding and thromboembolic outcomes were evaluated using multivariable logistic regression adjusted for age, sex, CHA 2 DS 2 ‐VASc score, and anticoagulant class, and the surgically treated subgroup was additionally compared using propensity score matching. Results Among 11,578 patients with PE, 1309 (11.3%) had AF. Of those who had AF, mean age was 66.9 years; 54% were female, and 83% had paroxysmal AF. The mean CHA 2 DS 2 ‐VASc and HAS‐BLED scores were 2.8 and 1.9, respectively. Thromboembolic events occurred in 196 (15%) patients, most commonly stroke (11%), followed by pulmonary embolism (4%) and deep venous thrombosis (4%). Bleeding events occurred in 313 patients (24%), most commonly hematuria (12%), gastrointestinal bleed (11%), epistaxis (5%), and intracranial hemorrhage (1%). Seventy‐two patients (6%) underwent the Nuss procedure and were younger (45.3 vs. 68.2 years, p < 0.001), predominantly male (65%), and had lower risk scores compared to the non‐Nuss cohort. Patients who underwent the Nuss procedure had significantly fewer bleeding events (5.6% vs. 25%, p < 0.001) with similar thromboembolic rates. The pectus severity index, available in the 370 patients who underwent dedicated radiologic review, was not associated with bleeding (adjusted OR 0.89, 95% CI 0.75–1.05). The difference in bleeding by surgical status persisted after multivariable adjustment (adjusted OR 0.28, 95% CI 0.10–0.79) and after propensity score matching (5.6% vs. 16.7%, p = 0.030). Conclusions AF was identified in approximately one in nine patients within this single‐institution cohort of adults with PE, with paroxysmal AF representing the predominant subtype. Patients who had undergone surgical repair demonstrated a lower incidence of bleeding events than anticipated based on their baseline risk profile; however, given the limited number of events observed, this finding should be interpreted with caution and requires validation in larger studies. In the absence of a non–PE comparator group, these data are insufficient to determine whether PE independently confers an elevated risk of AF, and prospective, controlled investigations are necessary to elucidate this relationship.
Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
Fatunde, Olubadewa A. , Vemulapalli, Hema Srikanth , Rodriguez, Juan F. , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Somappa, Aakash , Estrada-Vargas, Camilo A , Fatunde, Olubadewa A , Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J , McLeod, Christopher J , El Masry, Hicham , Deshmukh, Abhishek J , Kella, Danesh K , Killu, Ammar M , Mulpuru, Siva K , Sardana, Mayank , Scott, Luis R , Sugrue, Alan M, Srivathsan, Komandoor , Prasitlumkum, Narut , Rojas, Carlos, Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J. , Masry, Hicham El , Deshmukh, Abhishek , Kella, Danesh , Killu, Ammar M. , Mulpuru, Siva K. , Scott, Luis R. , Sugrue, Alan , Srivathsan, Komandoor

Mayo Clinic

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 | PMID 42743395 Get It

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy—Authors’ reply
Rodriguez, Juan F. , Vemulapalli, Hema Srikanth , Kim, James Y. , Scott, Luis R. , Valverde, Arturo M. , Deshmukh, Abhishek , McLeod, Christopher J. , Srivathsan, Komandoor , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Sardana, Mayank , Deshmukh, Abhishek J , Kapa, Suraj , McLeod, Christopher J , Srivathsan, Komandoor , Valverde, Arturo M , Kapa, Suraj , Kim, James

Mayo Clinic

Europace | July 22, 2026 | Volume: 28 | Issue: 7 | Pages: No page available

10.1093/europace/euag165 | PMID 42481027 Get It

Dual Coronary Sinus Lead Strategy to Avoid Tricuspid Valve Traversal in Biventricular Pacing
Baqal, Omar , Liu, Michael B. , Rodriguez, Juan F. , Kanaan, Christopher , Somappa, Aakash , Estrada‐Vargas, Camilo A., Srivathsan, Komandoor, Rodriguez-Riascos, Juan F , Kanaan, Christopher N , Baqal, Omar J , Liu, Michael , Estrada-Vargas, Camilo A , Asirvatham, Samuel J. , Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | July 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/pace.70348 | PMID 42400389 Get It

ABSTRACT Patients requiring permanent pacing after tricuspid valve intervention present challenges due to the need to cross tricuspid valve prostheses. We report three cases of successful dual coronary sinus (CS) lead implantation for biventricular pacing following a range of tricuspid interventions—surgical tricuspid annuloplasty, transcatheter edge‐to‐edge repair, and transcatheter tricuspid valve replacement. The approach avoided tricuspid valve traversal, was technically feasible and resulted in satisfactory pacing performance without procedural complications. Dual CS lead configurations were individualized based on CS anatomy and pacing characteristics. The degree of QRS narrowing achieved varied according to lead location and ventricular activation patterns, highlighting the importance of individualized lead placement strategies and device programming. Dual CS lead pacing may represent a viable alternative for biventricular pacing in selected patients with prior tricuspid valve interventions. Larger studies are needed to evaluate long‐term outcomes and define the optimal role of this approach among available pacing strategies in this patient population.
Safety and efficacy of pulsed field ablation for atrial fibrillation in patients with wild-type TTR amyloidosis: A multicentre study
Rodriguez-Riascos, J, Kim, J, Vemulapalli, H, Navale, D, Somappa, A, Srivathsan, K, Somappa, Aakash , Rodriguez, Juan F. , Vemulapalli, Hema Srikanth , Navale, Dravid, Srivathsan, Komandoor

Mayo Clinic

Europace | June 25, 2026 | Volume: 28 | Issue: Supplement_1 | Pages: No page available

10.1093/europace/euag105.164 Get It

Abstract Background/Introduction Atrial fibrillation (AF) is a common finding in patients with wild-type TTR amyloidosis. AF ablation represents a cornerstone of rhythm control in this population; however, the role of pulsed field ablation (PFA) remains unclear. Purpose This study aimed to describe the safety and efficacy of PFA for the treatment of atrial fibrillation in patients with wild-type TTR amyloidosis. Methods We conducted a prospective data collection of consecutive patients who underwent PFA for AF and had a confirmed diagnosis of wild-type TTR amyloidosis. The study included three centres within a major US health system. All procedures were performed between May 2024 and May 2025. A standardised follow-up strategy was applied, including 48-hour Holter monitoring between 90 and 180 days after ablation. The primary safety endpoint was the occurrence of procedural complications. The primary efficacy outcomes were acute procedural success and AF-free survival at six months after a blanking period of 30 days. AF recurrence was defined as any electrocardiographically documented episode lasting more than 30 seconds. Results A total of 13 patients were included in the study. The mean age was 72.6 ± 4.8 years, and all patients were male. Three patients (23.1%) underwent an index "redo" ablation. Seven patients (53.8%) had paroxysmal atrial fibrillation (AF). The median CHA2DS2-VASc score was 3 [2, 4.5], with a mean ejection fraction of 50.4 ± 14.8% and a mean left atrial volume index of 47.6 ± 15.7 mL/m². Eleven patients underwent PFA with the pentaspline Farawave catheter, and two with the focal Sphere-9 catheter. Additional extra-pulmonary vein lesions were performed in 11 patients, including posterior wall ablation in ten patients, cavotricuspid isthmus ablation in five, and mitral isthmus ablation in four patients. The primary endpoint occurred in one patient (7.7%) who developed acute respiratory failure complicated by pulseless electrical activity (PEA) arrest. The patient was successfully resuscitated but required prolonged hospital admission. All patients achieved acute pulmonary vein isolation, and six-month atrial fibrillation-free survival was 54.4%. Conclusion In this multicentre experience, pulsed field ablation (PFA) in patients with cardiac amyloidosis was feasible and acutely safe; however, the mid-term efficacy was suboptimal, with a relatively low six-month arrhythmia-free survival despite complete acute pulmonary vein isolation. These findings suggest that the current PFA strategies may not provide durable rhythm control in this population, underscoring the need for tailored ablation approaches and further research to improve long-term outcomes in patients with cardiac amyloidosis and atrial fibrillation.Figure 1
Post-Catheter Ablation Long-Term Antithrombotic Strategies in Atrial Fibrillation: A Network Meta-Analysis of Randomized Controlled Trials
Rodriguez-Riascos, Juan F., Navale, Dravid, Somappa, Aakash , Mendizabal, Ricardo Estrada, Scott, Luis R., Shen, Win-Kuang, Srivathsan, Komandoor , Estrada-Mendizábal, Ricardo J. , Rodriguez, Juan F. , Rodriguez-Riascos, Juan F , Estrada-Mendizabal, Ricardo J , Scott, Luis R , Shen, Win-Kuang , Srivathsan, Komandoor , Scott, Luis R.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | April 3, 2026 | Volume: 19 | Issue: 4 | Pages: No page available

10.1161/circep.125.014692 | PMID 41930400 Get It

BACKGROUND: Catheter ablation for atrial fibrillation is a widely used rhythm-control strategy, yet its role in reducing thromboembolic risk and enabling oral anticoagulation (OAC) discontinuation remains uncertain. This meta-analysis aims to comprehensively synthesize and evaluate randomized controlled trial evidence supporting long-term antithrombotic strategies in patients with atrial fibrillation undergoing catheter ablation. METHODS: A systematic literature search was performed in MEDLINE/PubMed, Embase, and the Cochrane Central Register of Controlled Trials to identify randomized controlled trials evaluating antithrombotic strategies after catheter ablation for atrial fibrillation. The primary outcome was ischemic stroke. A frequentist network meta-analysis comparing reported treatment arms, along with a pooled incidence meta-analysis for outcomes of interest, was conducted. RESULTS: Four randomized controlled trials, including 3924 patients, met the inclusion criteria. Three trials compared long-term OAC continuation versus OAC discontinuation, and 1 compared OAC continuation with left atrial appendage occlusion after catheter ablation. No significant differences in stroke incidence were observed when comparing OAC or left atrial appendage occlusion with no antithrombotic therapy (incidence rate ratio, 0.90 [95% CI, 0.02–33.85]; P =0.95; incidence rate ratio, 0.79 [95% CI, 0.00–241.01]; P =0.94, respectively). Among patients who discontinued antithrombotic therapy without undergoing left atrial appendage occlusion (n=1161), with 2864 cumulative person-years of follow-up, the pooled incidence of stroke was 0.23 events per 100 person-years (95% CI, 0.02–2.43; I 2 =0%). CONCLUSIONS: This analysis reinforces that, across randomized data, the incidence of thromboembolic events in patients who discontinued OAC after successful ablation remained low. However, the evaluation of net clinical benefit is limited by the low number of events across all treatment arms, underscoring the need for larger studies with prolonged follow-up to further validate the safety of this strategy, particularly in higher-risk populations.
The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy
Rodriguez, Juan F. , Vemulapalli, Hema Srikanth , Kim, James Y. , Scott, Luis R. , Valverde, Arturo M. , Deshmukh, Abhishek , McLeod, Christopher J. , Srivathsan, Komandoor , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Sardana, Mayank , Deshmukh, Abhishek J , Kapa, Suraj , McLeod, Christopher J , Srivathsan, Komandoor , Valverde, Arturo M , Kapa, Suraj , Kim, James

Mayo Clinic

Europace | March 25, 2026 | Volume: 28 | Issue: 3 | Pages: No page available

10.1093/europace/euag040 | PMID 41877360 Get It

Abstract Aims The clinical significance of early recurrences during the blanking period following pulmonary vein isolation (PVI) remains uncertain, particularly after pulsed field ablation (PFA). This study aimed to evaluate the prognostic impact of early recurrences at 30-, 60-, and 90-day thresholds on outcomes following PFA for atrial fibrillation (AF). Methods and results Consecutive patients who underwent PFA for AF across multiple centres within the Mayo Clinic health system were included. The primary endpoint was AF-free survival. Kaplan–Meier and multivariate Cox regression analyses were performed to compare outcomes between patients with and without early recurrences using 30-, 60-, and 90-day thresholds. A total of 1162 patients were included. The estimated AF-free survival at 1 year was 70%. Early recurrences within 30-, 60-, and 90-days post-ablation were significantly associated with late recurrences beyond 90 days (hazard ratio [HR] 5.9, 95% confidence interval [CI] 4.4–7.9, P &lt; 0.01; HR 6.6, 95% CI: 5.0–8.6, P &lt; 0.01; and HR 9.1, 95% CI: 7.0–11.7, P &lt; 0.01, respectively). These findings remained significant among patients undergoing continuous rhythm monitoring. Early recurrences within 30 days in this subgroup were significantly associated with a 1-year AF burden &gt;1% or the need for repeat AF ablation (odds ratio 25.0, 95% CI: 6.6–126.8, P &lt; 0.01). Conclusion Early recurrences following PFA are strongly predictive of long-term arrhythmia recurrence and are unlikely to represent transient inflammatory phenomena. Accordingly, the applicability of the conventional blanking interval after PFA should be reconsidered.
Safety, Efficacy, and Mid-Term Outcomes of Pulsed Field Ablation for Cavotricuspid Isthmus–Dependent Flutter: Real-World Data From a Major Health System Registry
Rodriguez, Juan F. , Vemulapalli, Hema Srikanth , Prajapati, Poojan , Muthu, Padmapriya , Kim, James Y. , Sorajja, Dan , Shen, Win‐Kuang , Masry, Hicham El , Valverde, Arturo M. , Munger, Thomas M. , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , El Masry, Hicham , Sardana, Mayank , Valverde, Arturo M , Srivathsan, Komandoor , Muthu, Padmapriya , Srivathsan, Komandoor , Kim, James

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | December 2, 2025 | Volume: 18 | Issue: 12 | Pages: No page available

10.1161/circep.125.014276 | PMID 41328574 Get It

BACKGROUND: Cavotricuspid isthmus (CTI) ablation is frequently performed either as a standalone procedure or in combination with pulmonary vein isolation. With the rapid adoption of pulsed field ablation for atrial fibrillation, it is essential to delineate the utility of this modality in treating CTI-dependent atrial flutter (AFL). This study aims to evaluate the procedural and clinical outcomes of CTI ablation using pulsed field energy. METHODS: We conducted a retrospective analysis of consecutive patients who underwent pulsed field ablation for CTI-dependent AFL between January 2024 and March 2025. The primary end points were acute procedural success, periprocedural complications, and CTI-dependent AFL recurrence during follow-up. RESULTS: A total of 132 patients underwent CTI nonthermal ablation. The median age was 69.5 years, and 27.3% were female. The Farawave catheter was used in 93.9% of cases, PulseSelect in 4.5%, and Sphere-9 in 1.5%. Acute block was achieved in 99.2% of patients, although 8 required adjunctive radiofrequency ablation to complete the line. Periprocedural complications included transient ST-segment elevation in 2 patients and transient conduction disturbances in 3. During a median follow-up of 114 days (n=131), 5 patients (3.8%) experienced recurrence of typical AFL. The 6-month typical AFL-free survival estimate was 93.6%. CONCLUSIONS: Pulsed field ablation appears to be a feasible and effective strategy for CTI-dependent AFL. However, anatomic variability may limit its universal applicability with current catheter designs. Although acute procedural success is high, the long-term durability of the CTI block and its comparative efficacy versus conventional thermal ablation remain areas requiring further investigation.
Evaluating Pulsed Field Ablation for Atrial Fibrillation: A Systematic Review and Meta‐Analysis of Procedural Outcomes
Prajapati, Poojan , Rodriguez, Juan F. , Muthu, Padmapriya , Vemulapalli, Hema S , Rodriguez-Riascos, Juan F , Vemulapalli, Hema Srikanth , Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | November 18, 2025 | Volume: 49 | Issue: 2 | Pages: 124-142

10.1111/pace.70082 | PMID 41251427 Get It

ABSTRACT Background While radiofrequency ablation (RFA) and cryoablation (CBA) are established treatments for atrial fibrillation (AF), pulsed field ablation (PFA) offers potential benefits. This study compares PFA's procedural outcomes with RFA and CBA. Methods A PRISMA‐guided systematic review searched PubMed, Cochrane, Embase, and Scopus through September 2024. Studies comparing PFA to RFA or CBA in paroxysmal and persistent AF were included. Results From 1413 titles, 28 studies (7944 patients, 4–13 months follow‐up) met inclusion criteria. PFA showed lower recurrence versus RFA (RR = 0.85, p < 0.05) and CBA (RR = 0.81, p < 0.01). Procedure times were shorter versus RFA (‐46.39 min, p < 0.01) and CBA (‐9.26 min, p < 0.01). PFA had fewer complications than CBA (RR = 0.45, p < 0.01) and thermal ablation (RR = 0.55, p < 0.01), with similar rates to RFA (RR = 0.81, p = 0.25). Fluoroscopy times were higher. Conclusion Promising results with PFA suggest it as a viable alternative to thermal ablation.