Back to Authors

Sugrue, Alan M

Mayo Clinic

Department of Medicine, Mayo Clinic, Rochester, MN.

Citations 5

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 | PMID 42743395

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
Leak closure following left atrial appendage exclusion procedures: A multicenter registry

Catheterization and Cardiovascular Interventions | March 2, 2022 | Volume: 99 | Issue: 6 | Pages: 1867-1876

10.1002/ccd.30139 | PMID 35233927

AbstractBackgroundThough infrequent, incomplete left atrial appendage closure (LAAC) may result from residual leaks. Percutaneous closure has been described though data is limited.MethodsWe compiled a registry from four centers of patients undergoing percutaneous closure of residual leaks following LAAC via surgical means or with the Watchman device. Leak severity was classified as none (no leak), mild (1–2 mm), moderate (3–4 mm), or severe (≥5 mm). Procedural and clinical success was defined as the elimination of leak or mild residual leak at the conclusion of the procedure or follow‐up, respectively.ResultsOf 72 (age 72.2 ± 9.2 years; 67% male) patients, 53 had undergone prior LAAC using the Watchman device and 19 patients surgical LAAC. Mean CHADS2‐VA2Sc score was 4.0 ± 1.8. The median leak size was 5 mm, range: 2–13). A total of 13 received Amplatzer Vascular Plug‐II, 18 received Amplatzer Duct Occluder‐II and 40 patients received coils. One underwent closure using a 21 mm‐Watchman. Procedural success was 94%. Zero surgical and nine Watchman patients (13%) had a residual leak at procedural‐end (five mild, three moderate, and one severe)—only one patient had no reduction in leak size. Overall leak size reduction was 94%. Two (3%) had intraoperative pericardial effusion. There were no device embolizations, device‐related thrombi, or procedural deaths. Clinical success was maintained at 94%. Two had cerebrovascular accidents—at 2 days (transient ischemic attack) and 10 months postprocedure. Two had major bleeding outside the 30‐day periprocedural window.ConclusionPercutaneous closure of residual leaks following left atrial appendage closure is feasible and associated with good outcomes. The procedural risk appears to be satisfactory.
Sinus rhythm heart rate increase after atrial fibrillation ablation is associated with lower risk of arrhythmia recurrence

Pacing and Clinical Electrophysiology | February 17, 2021 | Volume: 44 | Issue: 4 | Pages: 651-656

10.1111/pace.14197 | PMID 33592679

AbstractBackgroundPulmonary vein isolation (PVI) with autonomic modulation may be more successful than PVI alone for atrial fibrillation (AF) ablation and may be signaled by changes in sinus rhythm heart rate (HR) post ablation. We sought to determine if a change in sinus rhythm HR predicted AF recurrence post PVI.MethodsPatients who underwent AF ablation from 2000 to 2011 were included if sinus rhythm was noted on ECG within 90 days pre and 7 days post ablation. Basic ECG interval and HR changes were analyzed and outcomes determined.ResultsA total of 1152 patients were identified (74.3% male, mean age 57 ± 11 years). Mean AF duration was 5.2 ± 5.3 years. Paroxysmal AF was noted in 712 (61.8%) of the patients. Mean EF was 61% ± 6%. Sinus rhythm HR was 61 ± 11 pre‐ablation and 76 ± 13 bpm post‐ablation (27% ± 24% increase, p < .001). The ability of relative HR change post‐ablation to predict AF recurrence was borderline (hazard ratio 0.65 [0.41–1.01], p = .067). With patients separated into quartiles based on the relative HR change, the upper quartile with the largest relative increase in HR had a significantly lower rate of AF recurrence compared to the lowest quartile following multi variable modeling (p = .038). There were significant changes in PR (171 ± 28 to 167 ± 30 ms) and QTc (424 ± 25 to 434 ± 29 ms) intervals (both p < .001) but these were not predictive of outcome.ConclusionRelative changes in HR post AF ablation correlates with AF recurrence. Further prospective studies are needed to confirm this relationship.
Three-Dimensional Printed Biopatches With Conductive Ink Facilitate Cardiac Conduction When Applied to Disrupted Myocardium

Circulation: Arrhythmia and Electrophysiology | March 8, 2019 | Volume: 12 | Issue: 3 | Pages: No page available

10.1161/circep.118.006920 | PMID 30845835

Background: Reentrant ventricular arrhythmias are a major cause of sudden death in patients with structural heart disease. Current treatments focus on electrically homogenizing regions of scar contributing to ventricular arrhythmia with ablation or altering conductive properties using antiarrhythmic drugs. The high conductivity of carbon nanotubes may allow restoration of conduction in regions where impaired electrical conduction results in functional abnormalities. We propose a new concept for arrhythmia treatment using a stretchable, flexible biopatch with conductive properties to attempt to restore conduction across regions in which activation is disrupted. Methods: Carbon nanotube patches composed of nanofibrillated cellulose/single-walled carbon nanotube ink 3-dimensionally printed in conductive patterns onto bacterial nanocellulose were developed and evaluated for conductivity, flexibility, and mechanical properties. The patches were applied on 6 canines to epicardium before and after surgical disruption. Electroanatomic mapping was performed on normal epicardium, then repeated over surgically disrupted epicardium, and then finally with the patch applied passively. Results: We developed a 3-dimensional printable carbon nanotube ink complexed on bacterial nanocellulose that was (1) expressable through 3-dimensional printer nozzles, (2) electrically conductive, (3) flexible, and (4) stretchable. Six canines underwent thoracotomy, and, during epicardial ventricular pacing, mapping was performed. We demonstrated disruption of conduction after surgical incision in all 6 canines based on activation mapping. The patch resulted in restored conduction based on mapping and assessment of conduction direction and velocities in all canines. Conclusions: We have demonstrated 3-dimensional custom-printed electrically conductive carbon nanotube patches can be surgically manipulated to improve cardiac conduction when passively applied to surgically disrupted epicardial myocardium in canines.
Ischemic Stroke or Systemic Embolism After Transseptal Ablation of Arrhythmias in Patients With Cardiac Implantable Electronic Devices

Journal of the American Heart Association | April 14, 2016 | Volume: 5 | Issue: 4 | Pages: No page available

10.1161/jaha.115.003163 | PMID 27076562

Background Incidental mobile thrombi are commonly found on endovascular leads of cardiac implantable electronic devices ( CIED s). Transseptal puncture for catheter ablation of arrhythmia poses a risk for paradoxical embolism. We examined risk of ischemic stroke, transient ischemic attack ( TIA ), or systemic embolism after transseptal ablation in patients with and without CIED s. Methods and Results Using a national administrative claims database, 31 720 patients who underwent a transseptal catheter ablation between January 2004 and September 2014 were identified. Two propensity‐matched cohorts were created by matching demographic variables, administrative variables, Charlson Comorbidity Index, CHA 2 DS 2 ‐Vasc score, and year and indication for ablation (5533 and 11 300 patients with and without CIED s). Incidence rates and Cox proportional hazards models were used to estimate risk of ischemic stroke, TIA , or systemic embolism for patients with and without CIED s. Impact of oral anticoagulation ( OAC ) use on the endpoint was examined. Over a mean follow‐up of 2.1 years, the incidence of the combined endpoint was 1.9 per 100 person‐years in patients with CIED s and 1.5 per 100 person‐years in patients without CIED s ( P =0.03). Among patients not on OAC , presence of a cardiac device was associated with an increased risk (hazard ratio [ HR ], 1.71 [1.24–2.35]; P <0.01), whereas there was no association noted among patients treated with OAC ( HR , 0.98 [0.75–1.28]). Conclusion CIED s are associated with an increased risk of stroke, TIA , or systemic embolism after transseptal ablation, but this risk is attenuated with postablation OAC use. Role of anticoagulation post‐transseptal ablation in patients with CIED warrants further investigation.