Citations 8

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 | PMID 42743395

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy—Authors’ reply

Europace | July 22, 2026 | Volume: 28 | Issue: 7 | Pages: No page available

10.1093/europace/euag165 | PMID 42481027

Leadless Helix-fixation Pacemakers in Solid Organ Transplant Recipients: A Multisite Experience

Transplantation Direct | May 15, 2026 | Volume: 12 | Issue: 6 | Pages: e1949

10.1097/txd.0000000000001949 | PMID 42158035

Background. Solid organ transplant recipients (SOTRs) are at heightened risk for cardiovascular implantable electronic device-related complications, particularly infection, because of chronic immunosuppression and comorbidities. Although leadless pacemakers (LPs) reduce infection risk by eliminating transvenous leads and generator pockets, adoption in SOTRs has remained limited, largely because earlier systems were restricted to single-chamber ventricular pacing and lacked physiologic atrioventricular synchrony. The helix-fixation Aveir LP platform enables atrial, ventricular, and dual-chamber leadless pacing, but clinical experience in transplant recipients remains limited. Methods. We conducted a retrospective, multisite analysis across an integrated health system, identifying all adult SOTRs who underwent Aveir LP implantation between January 2022 and October 2025. Clinical characteristics, transplant details, pacing indications, device configuration, procedural outcomes, and follow-up data were collected. Primary outcomes included procedural success, complications, and device-related infection. Secondary outcomes included pacing performance, need for system revision or upgrade, and early device durability. Results. Thirteen SOTRs (mean age 64 ± 15 y; 15% female) underwent Aveir LP implantation, including atrial (n = 4), ventricular (n = 5), and dual-chamber (n = 4) systems. Transplanted organs included heart (46%), lung (31%), kidney (38%), and liver (15%), with 31% having multiple organ transplants. Over half of patients were critically ill at implantation, and 46% were dialysis-dependent, representing a high-risk cohort. All procedures were acutely successful with no intraprocedural complications. During a median follow-up of 258 d (interquartile range, 216–641 d), no device-related infections occurred. Electrical performance remained stable, with 1 atrial device replacement at 2.5 y for elevated capture thresholds. Conclusions. In a high-risk population of SOTRs, atrial and atrioventricular synchronous leadless pacing using the Aveir platform was feasible, achieved high acute procedural success, and demonstrated favorable early safety signals, including absence of device-related infection over available follow-up. Larger studies with longer-term follow-up are needed to define durability and long-term outcomes.
The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy

Europace | March 25, 2026 | Volume: 28 | Issue: 3 | Pages: No page available

10.1093/europace/euag040 | PMID 41877360

Abstract Aims The clinical significance of early recurrences during the blanking period following pulmonary vein isolation (PVI) remains uncertain, particularly after pulsed field ablation (PFA). This study aimed to evaluate the prognostic impact of early recurrences at 30-, 60-, and 90-day thresholds on outcomes following PFA for atrial fibrillation (AF). Methods and results Consecutive patients who underwent PFA for AF across multiple centres within the Mayo Clinic health system were included. The primary endpoint was AF-free survival. Kaplan–Meier and multivariate Cox regression analyses were performed to compare outcomes between patients with and without early recurrences using 30-, 60-, and 90-day thresholds. A total of 1162 patients were included. The estimated AF-free survival at 1 year was 70%. Early recurrences within 30-, 60-, and 90-days post-ablation were significantly associated with late recurrences beyond 90 days (hazard ratio [HR] 5.9, 95% confidence interval [CI] 4.4–7.9, P < 0.01; HR 6.6, 95% CI: 5.0–8.6, P < 0.01; and HR 9.1, 95% CI: 7.0–11.7, P < 0.01, respectively). These findings remained significant among patients undergoing continuous rhythm monitoring. Early recurrences within 30 days in this subgroup were significantly associated with a 1-year AF burden >1% or the need for repeat AF ablation (odds ratio 25.0, 95% CI: 6.6–126.8, P < 0.01). Conclusion Early recurrences following PFA are strongly predictive of long-term arrhythmia recurrence and are unlikely to represent transient inflammatory phenomena. Accordingly, the applicability of the conventional blanking interval after PFA should be reconsidered.
Safety, Efficacy, and Mid-Term Outcomes of Pulsed Field Ablation for Cavotricuspid Isthmus–Dependent Flutter: Real-World Data From a Major Health System Registry

Circulation: Arrhythmia and Electrophysiology | December 2, 2025 | Volume: 18 | Issue: 12 | Pages: No page available

10.1161/circep.125.014276 | PMID 41328574

BACKGROUND: Cavotricuspid isthmus (CTI) ablation is frequently performed either as a standalone procedure or in combination with pulmonary vein isolation. With the rapid adoption of pulsed field ablation for atrial fibrillation, it is essential to delineate the utility of this modality in treating CTI-dependent atrial flutter (AFL). This study aims to evaluate the procedural and clinical outcomes of CTI ablation using pulsed field energy. METHODS: We conducted a retrospective analysis of consecutive patients who underwent pulsed field ablation for CTI-dependent AFL between January 2024 and March 2025. The primary end points were acute procedural success, periprocedural complications, and CTI-dependent AFL recurrence during follow-up. RESULTS: A total of 132 patients underwent CTI nonthermal ablation. The median age was 69.5 years, and 27.3% were female. The Farawave catheter was used in 93.9% of cases, PulseSelect in 4.5%, and Sphere-9 in 1.5%. Acute block was achieved in 99.2% of patients, although 8 required adjunctive radiofrequency ablation to complete the line. Periprocedural complications included transient ST-segment elevation in 2 patients and transient conduction disturbances in 3. During a median follow-up of 114 days (n=131), 5 patients (3.8%) experienced recurrence of typical AFL. The 6-month typical AFL-free survival estimate was 93.6%. CONCLUSIONS: Pulsed field ablation appears to be a feasible and effective strategy for CTI-dependent AFL. However, anatomic variability may limit its universal applicability with current catheter designs. Although acute procedural success is high, the long-term durability of the CTI block and its comparative efficacy versus conventional thermal ablation remain areas requiring further investigation.
Polymorphic Ventricular Tachycardia After Cardioversion for AF with Tachycardia-induced Cardiomyopathy

Arrhythmia & Electrophysiology Review | November 24, 2025 | Volume: 14 | Issue: No issue available | Pages: No page available

10.15420/aer.2025.38 | PMID 41346408

Ventricular arrhythmias after electrical cardioversion for AF are rare. Most of these arrhythmias are related to QT prolongation, resulting from marked and sudden slowing of heart rates, treatment with Class III antiarrhythmic drugs or other QT-prolonging medications, and the ventricular repolarisation remodelling effect of electrical cardioversion. A case of polymorphic ventricular tachycardia post-cardioversion of rapid AF in a patient with tachycardia-induced cardiomyopathy and the use of amiodarone is reported.
Elevated lipoprotein(a) levels linked to new-onset atrial fibrillation: insights from a retrospective cohort study

European Journal of Preventive Cardiology | February 7, 2025 | Volume: 32 | Issue: 9 | Pages: 769-777

10.1093/eurjpc/zwaf063 | PMID 39919039

Abstract Aims Atrial fibrillation (AF) is the most common cardiac arrhythmia. Although lipoprotein(a) [Lp(a)] is known to be a well-established risk factor for atherosclerotic cardiovascular disease, its role in the development of AF, independent of this association, remains unclear. Methods and results Adult patients from the three Mayo Clinic sites with a baseline Lp(a) and without AF history were included. Patients were categorized into two groups based on their Lp(a) levels: high Lp(a) (≥50 mg/dL) and low Lp(a) (<50 mg/dL). Survival probabilities free from incident AF were compared between Lp(a) groups, during a follow-up period up to 15 years, using the Kaplan–Meier curve and the log-rank test. Multivariable Cox regression analysis was also conducted. A total of 75 376 patients were included (median age: 55 years, 59% males), with a median follow-up duration of 8.8 (inter-quartile range: 3.4, 14.8) years. Incident AF was detected in 5738 (7.6%) patients. Survival probability free from incident AF was significantly lower in patients with elevated Lp(a) (86%) compared with those with low Lp(a) (88%, log-rank P < 0.001). Multivariable analysis adjusted for potential risk factors of AF showed a statistically significant association of elevated Lp(a) with an 11% increase in AF risk (adjusted hazard ratio: 1.11, 95% confidence interval: 1.05–1.18). Conclusion Our study suggests that elevated Lp(a) (≥50 mg/dL) is an independent risk factor for incident AF. Future prospective studies are warranted to validate our results and to test if reducing Lp(a) could mitigate the burden of AF.
Abstract 4147545: Adverse Events with Pulsed Field Ablation - A Review of the Food and Drug Administration’s Manufacturer and User Facility Device Experience Database

Circulation | November 14, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4147545

Introduction: Pulsed field ablation (PFA) is an adaptation of direct current ablation first used for catheter ablation in the 1980s. Expectations of a reduced risk profile led to the current resurgence in investment and interest in the technology as a potential alternative energy source for ablations to treat atrial fibrillation (AF). However, reports of adverse events, including new risks, are increasing. Research Question: How many adverse effects are reported with the use of newly available PFA systems? Aims: Quantify and describe the adverse events from PFA reported to date in the Food and Drug Administration’s (FDA) Manufacturer and User Facility Device Experience (MAUDE) database. Methods: We searched the U.S. FDA’s MAUDE database for all reports filed with the code “QZI”, which is the product code for PFA systems created with the first FDA approvals in February 2024. All reports from inception through April 2024 (a total of 3 months) were included in this review. Per manufacturer presentation in May 2024, approximately 1000 cases utilizing PFA had been captured in a post-market registry of the predominant commercially used technology, but the exact number of cases can not be determined from MAUDE data. Results: A total of 217 adverse events were reported over the first 3 months of US approval, with 91 of these considered patient injuries. These injuries included 10 cases of cardiac tamponade, 7 reports of postoperative arrhythmia, 6 instances of device-related tissue entrapment, 5 cases of hemolysis with impaired renal function, 5 cases of stroke or TIA, including both embolic and hemorrhagic, 3 cases of intraoperative heart block, 2 coronary spasms, and 2 cases of intraoperative ST elevation. (Figure) Of the 91 reported patient safety events, 46 required hospitalization, 13 cases required temporary pacing, 11 required pericardiocentesis, 4 required dialysis, 4 required cardiothoracic surgery, and 2 required cardioversion. Conclusions: A number of adverse events have been reported to the MAUDE database in the first 3 months of FDA approval of PFA. The cardiac electrophysiology community should remain vigilant to ensure that the benefit-risk profile remains acceptable for patient safety.