Back to Authors

Deshmukh, Abhishek J

0000-0002-9560-1102

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Citations 61

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 | PMID 42743395

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
Cardiac Resynchronization Therapy and Circulating Metabolomic Profile in Patients With Advanced Heart Failure

Circulation: Heart Failure | September 10, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/circheartfailure.125.014148 | PMID 42717876

BACKGROUND: It is unknown whether cardiac resynchronization therapy (CRT) improves systemic metabolomic profile by enhancing left ventricular function. The observational cohort study aimed to investigate the effect of CRT on left ventricular ejection fraction (LVEF) and circulating plasma metabolites in patients who had heart failure with reduced LVEF. METHODS: We prospectively screened patients with ischemic cardiomyopathy and nonischemic cardiomyopathy who received CRT with a defibrillator for LVEF ≤35% according to current guidelines. Clinical assessment included echocardiography and device interrogation. Blood samples for metabolomic analysis were collected before CRT and at 6-month follow-up. Plasma was subjected to gas chromatography-mass spectrometry and 1 H nuclear magnetic resonance-based metabolomic analysis. RESULTS: Totally 92 patients were enrolled, with a mean age of 67.3±11.3 years (37.0% female). LVEF was significantly improved from 28.9±7.6% at baseline to 36.0±11.3% at 6 months ( P <0.001) and to 40.1±12.6% at 12 months ( P <0.001). After CRT, 42 metabolite features were significantly decreased compared with the baseline. The ketone bodies, including 3-hydroxybutyrate ( P <0.001) and acetone ( P =0.01), were reduced. A branched-chain amino acid, isoleucine, was also decreased after CRT ( P =0.01). These metabolomic changes were mainly observed in the nonischemic cardiomyopathy group, while the metabolomic profile in the ischemic cardiomyopathy group was characterized by enhanced amino acid oxidation and elevated levels of lactate and pyruvate. The improvement in LVEF positively correlated with the ratio of changes in ketone bodies and isoleucine. CONCLUSIONS: CRT may modulate the systemic plasma metabolomic profile, which correlated with improvement in left ventricular function in patients with severe heart failure with reduced ejection fraction.
Tirzepatide and the Incidence of Atrial Fibrillation in Adults With Overweight or Obesity: An Updated Meta‐Analysis of Randomized Controlled Trials

Journal of the American Heart Association | September 9, 2026 | Volume: 15 | Issue: 18 | Pages: No page available

10.1161/jaha.125.044249 | PMID 42714458

Background Tirzepatide is a dual agonist for glucose‐dependent insulinotropic polypeptide and glucagon‐like peptide‐1 receptors, with proven efficacy in weight loss and improvement in cardiovascular outcomes. However, the effects of tirzepatide on the incidence of atrial fibrillation in patients with overweight or obesity remain unclear. Methods PubMed, Embase, and Cochrane Library were searched for randomized controlled trials comparing tirzepatide versus placebo for individuals with overweight or obesity. Odds ratios (ORs) with 95% credible intervals (CrIs) were pooled using a Bayesian binomial‐normal hierarchical model, appropriate for rare‐event outcomes. Results Our meta‐analysis included 10 randomized controlled trials, including 6515 individuals, of whom 4491 (68.9%) were randomized to tirzepatide. The pooled OR was 2.20 (95% CrI, 0.81–6.75) for atrial fibrillation, 2.16 (95% CrI, 0.90–5.87) for atrial arrhythmia, and 1.84 (95% CrI, 1.04–3.90) for any arrhythmia. Conclusions Tirzepatide was not associated with atrial fibrillation or atrial arrhythmia. Although higher odds of overall arrhythmias were observed, event rates were low and the findings should be interpreted cautiously.
Large Language Models for PVC Localization: Proof of Concept or Clinical Tool?

Journal of Cardiovascular Electrophysiology | September 8, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70499 | PMID 42709933

The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy—Authors’ reply

Europace | July 22, 2026 | Volume: 28 | Issue: 7 | Pages: No page available

10.1093/europace/euag165 | PMID 42481027

First-in-Human Clinical Experience With Focal Pulsed Field and Radiofrequency Dual-Modality Ablation for Treatment Refractory Left Ventricular Summit PVCs

Circulation: Arrhythmia and Electrophysiology | April 24, 2026 | Volume: 19 | Issue: 6 | Pages: No page available

10.1161/circep.126.014942 | PMID 42030455

BACKGROUND: Radiofrequency (RF) ablation of premature ventricular complexes (PVCs) originating from the left ventricular summit may be unsuccessful, highlighting the need for alternative approaches. We aimed to assess the efficacy and safety of a novel dual-modality focal catheter in treating left ventricular summit PVCs in patients who had failed previous RF ablation. METHODS: Patients were prospectively enrolled and underwent a redo ablation procedure using an irrigated, contact-force sensing, dual-modality focal catheter (TactiFlex Duo, Abbott) under compassionate use indication. The ablation strategy, including the choice of energy modality (monopolar pulsed field [PF], RF, or both), was left to the operator’s discretion. Safety assessments included serial biomarkers, renal function, and CMR within 36 hours. Efficacy was defined as ≥80% reduction in PVC burden with symptom resolution at 3-month follow-up. RESULTS: Six consecutive patients (4 men; mean age, 53.8±15 years) with symptomatic left ventricular summit PVCs and a prior failed RF ablation (range, 1–2) were prospectively enrolled. All PVCs had an inferior axis, with a left bundle V1 morphology observed in 4 of 6 cases (mean burden, 30.1±5.3%). Acute suppression of PVCs was achieved in all cases. Acute suppression with a single PF application in the great cardiac vein-anterior interventricular vein occurred in 2 patients, while 3 patients required additional RF, PF, or combined RF+PF applications at adjacent sites. One patient with an inaccessible great cardiac vein-anterior interventricular vein was successfully treated in the left ventricular outflow tract with RF+PF application. Transient, reversible left anterior descending vasospasm was observed during PF delivery in 2 of 5 cases that underwent PF application adjacent to a coronary artery, despite pretreatment with intracoronary nitroglycerin without ECG or hemodynamic sequelae. All patients had durable suppression of PVCs at follow-up. CONCLUSIONS: In its first human application, dual-modality ablation was feasible and effective for refractory left ventricular summit PVCs. Transient coronary vasospasm occurred, though it was reversible and without acute clinical consequences.
Systemic Embolic Events in People Who Inject Drugs With Patent Foramen Ovale and Right-Sided Infective Endocarditis: A Systematic Review

Open Forum Infectious Diseases | April 24, 2026 | Volume: 13 | Issue: 5 | Pages: No page available

10.1093/ofid/ofag245 | PMID 42169692

Abstract Background Knowing the prevalence of patent foramen ovale (PFO) and the increasing number of people who inject drugs (PWID) with right-sided infective endocarditis (RSIE), we aimed to better characterize the syndrome of injection drug use, RSIE, and PFO with systemic embolic events. Method A systematic search across multiple databases was independently screened using predefined criteria (from inception until September 2025). Published cases of adult PWID diagnosed with RSIE and ischemic stroke or other systemic embolic event were included, provided they had PFO assessment. Individuals were excluded if they had cardiac implantable electronic device (CIED) infections or any other conditions associated with systemic or paradoxical embolism. Results The review identified 13 studies with 14 young patients, mostly without comorbidities, predominantly infected with Staphylococcus aureus. In most cases, echocardiography revealed large tricuspid valve vegetations. Neuroimaging confirmed multiple ischemic infarcts, while 5 patients showed emboli outside the central nervous system (4 of them as the only systemic embolism). At least 11 (79%) patients had echocardiographic evidence of right-to-left shunting. Management included cardiac surgery in 6 cases that involved valve replacement or repair, percutaneous PFO closure in 2 cases, and percutaneous mechanical aspiration in 1 case. Three patients (21%) died during hospitalization, and only 27.3% patients had outpatient follow-up. Conclusions RSIE with systemic embolism in PWID with PFO has rarely been reported, affects younger patients without sex predominance, and was usually due to S. aureus with large tricuspid vegetations. Right-to-left shunting was characteristic, and outcomes were poor despite combined medical, surgical, and interventional therapies.
The blanking interval after atrial fibrillation ablation: time for reassessment with pulsed field energy

Europace | March 25, 2026 | Volume: 28 | Issue: 3 | Pages: No page available

10.1093/europace/euag040 | PMID 41877360

Abstract Aims The clinical significance of early recurrences during the blanking period following pulmonary vein isolation (PVI) remains uncertain, particularly after pulsed field ablation (PFA). This study aimed to evaluate the prognostic impact of early recurrences at 30-, 60-, and 90-day thresholds on outcomes following PFA for atrial fibrillation (AF). Methods and results Consecutive patients who underwent PFA for AF across multiple centres within the Mayo Clinic health system were included. The primary endpoint was AF-free survival. Kaplan–Meier and multivariate Cox regression analyses were performed to compare outcomes between patients with and without early recurrences using 30-, 60-, and 90-day thresholds. A total of 1162 patients were included. The estimated AF-free survival at 1 year was 70%. Early recurrences within 30-, 60-, and 90-days post-ablation were significantly associated with late recurrences beyond 90 days (hazard ratio [HR] 5.9, 95% confidence interval [CI] 4.4–7.9, P &lt; 0.01; HR 6.6, 95% CI: 5.0–8.6, P &lt; 0.01; and HR 9.1, 95% CI: 7.0–11.7, P &lt; 0.01, respectively). These findings remained significant among patients undergoing continuous rhythm monitoring. Early recurrences within 30 days in this subgroup were significantly associated with a 1-year AF burden &gt;1% or the need for repeat AF ablation (odds ratio 25.0, 95% CI: 6.6–126.8, P &lt; 0.01). Conclusion Early recurrences following PFA are strongly predictive of long-term arrhythmia recurrence and are unlikely to represent transient inflammatory phenomena. Accordingly, the applicability of the conventional blanking interval after PFA should be reconsidered.
Positron Emission Tomography/Computed Tomography in Cardiac Implantable Electronic Device Infections: Insights From the Emerging Infections Network

Open Forum Infectious Diseases | March 3, 2026 | Volume: 13 | Issue: 3 | Pages: No page available

10.1093/ofid/ofag109 | PMID 41852557

Abstract The practice patterns of fluorine 18–labeled fluorodeoxyglucose positron emission tomography/computed tomography ([18F] FDG PET/CT) use in cardiac implantable electronic device infection remain undefined. Among 258 Emerging Infections Network respondents, 69% reported never or rarely using [18F] FDG PET/CT. Limited access and insurance barriers were the most common obstacles.
Impact of Timing of Atrial Fibrillation Ablation on AF Recurrence and Clinical Outcomes in Patients With HFpEF and HFrEF

Journal of Cardiovascular Electrophysiology | January 14, 2026 | Volume: 37 | Issue: 4 | Pages: 898-899

10.1111/jce.70247 | PMID 41528062