Department of Cardiovascular Medicine, Mayo Clinic, Phoenix, Arizona, USA.
Citations 5
Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
Management of Recurrent Atrial Fibrillation After Catheter Ablation: Five-Year Outcomes of Repeat Catheter Ablation Versus Antiarrhythmic Therapy
Europace | August 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
Abstract Background Recurrence of symptomatic atrial fibrillation (AF) after catheter ablation (CA) is not uncommon. However, real-world long-term data on clinical outcomes of rhythm control strategies in patients with recurrent AF after CA remain limited. Methods Using the TriNetX database, we identified adult patients (≥18 years) with recurrent AF after index CA. A 3-month blanking period was applied, during which no rhythm-control therapy was received. Patients were classified into two groups: repeat CA or initiation of antiarrhythmic drug (AAD) therapy. Propensity score matching (PSM) was performed to balance baseline characteristics. Hazard ratios (HR) with 95% confidence intervals (CI) were calculated. Outcomes included all-cause mortality, all-cause hospitalization, heart failure (HF) exacerbation, ischemic stroke, and major bleeding over 5 years. Results Among 4,056 patients with recurrent AF post-CA, 17.2% underwent repeat CA. After PSM, 697 patients in the repeat CA group (mean age 68.9 ± 9.6 years; 35.7% female) and 697 in the AAD group (mean age 68.4 ± 10.0 years; 37.6% female) were analyzed. Repeat CA was associated with lower all-cause mortality (3.3% vs 8.2%; HR 0.44; 95% CI, 0.27–0.72; P < 0.01), all-cause hospitalization (42.8% vs 56.4%; HR 0.71; 95% CI, 0.61–0.82; P < 0.01) and HF exacerbation (12.5% vs 24.8%; HR 0.50; 95% CI, 0.39–0.64; P < 0.01). No differences were observed in ischemic stroke (5.3% vs 4.7%; HR 1.22; 95% CI, 0.77–1.96; P = 0.40) or major bleeding (4.6% vs 6.2%; HR 0.82; 95% CI, 0.52–1.29; P = 0.39). Conclusions Repeat CA was associated with lower mortality, hospitalization, and HF exacerbation over 5 years.
Post-Catheter Ablation Long-Term Antithrombotic Strategies in Atrial Fibrillation: A Network Meta-Analysis of Randomized Controlled Trials
Circulation: Arrhythmia and Electrophysiology | April 3, 2026 | Volume: 19 | Issue: 4 | Pages: No page available
BACKGROUND: Catheter ablation for atrial fibrillation is a widely used rhythm-control strategy, yet its role in reducing thromboembolic risk and enabling oral anticoagulation (OAC) discontinuation remains uncertain. This meta-analysis aims to comprehensively synthesize and evaluate randomized controlled trial evidence supporting long-term antithrombotic strategies in patients with atrial fibrillation undergoing catheter ablation. METHODS: A systematic literature search was performed in MEDLINE/PubMed, Embase, and the Cochrane Central Register of Controlled Trials to identify randomized controlled trials evaluating antithrombotic strategies after catheter ablation for atrial fibrillation. The primary outcome was ischemic stroke. A frequentist network meta-analysis comparing reported treatment arms, along with a pooled incidence meta-analysis for outcomes of interest, was conducted. RESULTS: Four randomized controlled trials, including 3924 patients, met the inclusion criteria. Three trials compared long-term OAC continuation versus OAC discontinuation, and 1 compared OAC continuation with left atrial appendage occlusion after catheter ablation. No significant differences in stroke incidence were observed when comparing OAC or left atrial appendage occlusion with no antithrombotic therapy (incidence rate ratio, 0.90 [95% CI, 0.02–33.85]; P =0.95; incidence rate ratio, 0.79 [95% CI, 0.00–241.01]; P =0.94, respectively). Among patients who discontinued antithrombotic therapy without undergoing left atrial appendage occlusion (n=1161), with 2864 cumulative person-years of follow-up, the pooled incidence of stroke was 0.23 events per 100 person-years (95% CI, 0.02–2.43; I 2 =0%). CONCLUSIONS: This analysis reinforces that, across randomized data, the incidence of thromboembolic events in patients who discontinued OAC after successful ablation remained low. However, the evaluation of net clinical benefit is limited by the low number of events across all treatment arms, underscoring the need for larger studies with prolonged follow-up to further validate the safety of this strategy, particularly in higher-risk populations.
Artificial Intelligence–Electrocardiography to Predict Incident Atrial Fibrillation and Clinical Outcomes in Kidney Transplant Recipients
Key Points Atrial fibrillation after kidney transplantation is common and is associated with poor prognosis. Artificial intelligence applied to 12-lead electrocardiograms pretransplant accurately predicts the risk of new-onset atrial fibrillation in our cohort. High-risk artificial intelligence electrocardiography score was independently associated with increased risk of mortality and allograft failure. Background Incident atrial fibrillation (AF) is common after kidney transplantation (KTx) and is associated with worse clinical outcomes. Artificial intelligence electrocardiography (AI-ECG) algorithms have demonstrated efficacy in predicting risk of new-onset AF in the general population; however, their prognostic value in KTx recipients is relatively unknown. Methods Retrospective analysis was conducted on KTx recipients without AF, with at least one pretransplant ECG between 2011 and 2021 across three tertiary centers in the United States (Mayo Clinic sites in MN, AZ, and FL). A previously validated AI-ECG algorithm estimated the probability of incident AF for each patient. Based on AI-ECG probabilities, patients were categorized into high-risk and low-risk groups, with the optimal AI-ECG score cutoff determined. The incidence of new-onset AF, allograft failure, and mortality was compared between groups. Results Overall, 6246 patients (age 53.5±13.8 years; 58.9% male) were included. Pretransplant AI-ECG probability of AF ≥5% was the optimal cutoff for high risk of incident AF (sensitivity 72%, specificity 62%). High-risk scores were associated with true new-onset AF at 30 days (adjusted hazard ratio [aHR], 2.89; 95% confidence intervals [CI], 2.05 to 4.09; P < 0.001), 3 years (aHR, 2.54; 95% CI, 1.99 to 3.26, P < 0.001), and 5 years post-transplant (aHR, 2.48; 95% CI, 1.99 to 3.09, P < 0.001). High-risk AI-ECG scores were also associated with increased mortality (aHR, 1.56; 95% CI, 1.30 to 1.88, P < 0.001) and overall allograft failure (aHR, 1.50; 95% CI, 1.30 to 1.75, P < 0.001) through the 5-year follow-up. Conclusions This pretransplant AI-ECG parameter identified patients at increased risk of new-onset AF post-KTx and provided prognostic utility. Overall, this easy to obtain tool allows for risk stratification of patients who may benefit from closer monitoring, targeted risk factor modification, and early intervention.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available
Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.