Citations

Clear

23 citation(s) found for "Albuquerque, Felipe C".

Cerebrospinal Fluid Biomarkers for Diagnosis and the Prognostication of Acute Ischemic Stroke: A Systematic Review
Adeleye, Olufunmilola , Winkler, Ethan A. , Hartke, Joelle N., Karahalios, Katherine , Mihaljević, Sandra, Rani, Anupama , Raikwar, Sudhanshu P. , Rulney, Jarrod, Scherschinski, Lea , Ducruet, Andrew F. , Albuquerque, Felipe C. , Lawton, Michael T. , Raikwar, Sudhanshu , Scherschinski, Lea , Adeleye, Olufunmilola , Naik, Anant , Koester, Stefan Wolfgang , Desai, Shashvat M. , Catapano, Joshua S , Jadhav, Ashutosh P. , Jha, Ruchira Menka

Mayo Clinic

International Journal of Molecular Sciences | June 30, 2023 | Volume: 24 | Issue: 13 | Pages: 10902

10.3390/ijms241310902 | PMID 37446092 Get It

Despite the high incidence and burden of stroke, biological biomarkers are not used routinely in clinical practice to diagnose, determine progression, or prognosticate outcomes of acute ischemic stroke (AIS). Because of its direct interface with neural tissue, cerebrospinal fluid (CSF) is a potentially valuable source for biomarker development. This systematic review was conducted using three databases. All trials investigating clinical and preclinical models for CSF biomarkers for AIS diagnosis, prognostication, and severity grading were included, yielding 22 human trials and five animal studies for analysis. In total, 21 biomarkers and other multiomic proteomic markers were identified. S100B, inflammatory markers (including tumor necrosis factor-alpha and interleukin 6), and free fatty acids were the most frequently studied biomarkers. The review showed that CSF is an effective medium for biomarker acquisition for AIS. Although CSF is not routinely clinically obtained, a potential benefit of CSF studies is identifying valuable biomarkers from the pathophysiologic microenvironment that ultimately inform optimization of targeted low-abundance assays from peripheral biofluid samples (e.g., plasma). Several important catabolic and anabolic markers can serve as effective measures of diagnosis, etiology identification, prognostication, and severity grading. Trials with large cohorts studying the efficacy of biomarkers in altering clinical management are still needed.
Intrasaccular flow disruption for ruptured aneurysms: an international multicenter study
Diestro, Jose Danilo Bengzon , Dibas, Mahmoud , Adeeb, Nimer , Regenhardt, Robert W. , Vranic, Justin E. , Guenego, Adrien , Lay, Sovann V. , Balushi, Ali Al , Shotar, Eimad , Premat, Kévin , Möhlenbruch, Markus , Foreman, Paul M. , Vachhani, Jay A. , Župančić, Vedran , Hafeez, Muhammad Ubaid , Rai, Hamid, Tutino, Vincent M. , Mirshani, Shervin, Ghozy, Sherief , Alotaibi, Naif M. , Rabinov, James D. , Ren, Yifan , Goren, Oded , Piano, Mariangela , Michelozzi, Caterina , Elens, Stéphanie , Starke, Robert M. , Nguyên, Anh , Jones, Jesse , Psychogios, Marios, Spears, Julian , Bullrich, María Bres , Mayich, Michael , Salem, Mohamed M. , Burkhardt, Jan‐Karl , Jankowitz, Brian T. , Ulfert, Christian , Lubicz, Boris , Puri, Ajit S , Pero, Guglielmo , Asadi, Hamed , Siddiqui, Adnan H. , Ducruet, Andrew F. , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Stapleton, Christopher J. , Knopman, Jared , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Aziz‐Sultan, Mohammad Ali , Patel, Aman B. , Dmytriw, Adam A. , Shotar, Eimad , Saliou, Guillaume , Lylyk, Ivan , Vachhani, Jay A , Rai, Hamid , Tutino, Vincent M , Harker, Pablo , Ren, Yifan , Schirmer, Clemens M , Michelozzi, Caterina , Elens, Stephanie , Hassan, Ameer E , Nguyen, Anh , Jones, Jesse , Parra-Fariñas, Carmen , Salem, Mohamed M , Domingo, Ricardo A , Tawk, Rabih, Pero, Guglielmo , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Cuellar-Saenz, Hugo H , Dmytriw, Adam A , Siddiqui, Adnan H , Dibas, Mahmoud , Ghozy, Sherief , Diestro, Jose Danilo B , Regenhardt, Robert W , Hafeez, Muhammad U , Ulfert, Christian , Lay, Sovann V , Burkhardt, Jan‐Karl , Renieri, Leonardo , Naamani, Kareem El , Saliou, Guillaume , Lylyk, Iván , Rutledge, Caleb , Harker, Pablo , Schirmer, Clemens M. , Kühn, Anna Luisa , Hassan, Ameer E , Salehani, Arsalaan , Psychogios, Marios‐Nikos , Domingo, Ricardo A. , Huynh, Thien , Tawk, Rabih G. , Panni, Pietro , Griessenauer, Christoph J. , Du, Rose , Jabbour, Pascal , Limbucci, Nicola , Cuellar, Hugo , Cognard, Christophe

Mayo Clinic

Journal of NeuroInterventional Surgery | July 22, 2022 | Volume: 15 | Issue: 9 | Pages: 844-850

10.1136/jnis-2022-019153 | PMID 35868856 Get It

Background The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. Methods Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. Results The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. Conclusion There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.
Letter: An International Investigation Into the COVID-19 Pandemic and Workforce Depletion in Highly Specialized Neurointerventional Units – Insights From Stroke Thrombectomy and Aneurysm Registry and Endovascular Neurosurgery Research Group
Alawieh, Ali , Kasab, Sami Al , Almallouhi, Eyad , Levitt, Michael R. , Jabbour, Pascal , Sweid, Ahmad , Starke, Robert M. , Wolfe, Stacey Q , Fragata, Isabel , Maier, Ilko , Matouk, Charles, Howard, Brian M. , Grossberg, Jonathan A , Cawley, M. F., Kan, Peter , Hafeez, Muhammad Ubaid , Singer, Justin, Crowley, R. Webster , Joshi, Krishna C. , Brinjikji, Waleed , Ogilvy, Christopher S. , Gomez‐Paz, Santiago , Veznedaroglu, Erol, Binning, Mandy J., Soomro, Jazba , Williamson, Richard , Chalhoub, Reda , Crosa, Roberto , Webb, Sharon, Psychogios, Marios, Ducruet, Andrew F. , Albuquerque, Felipe C. , Turner, Raymond, Casagrande, Walter, Leacy, Reade De , Fessler, Richard D., Osanai, Toshiya , Chowdhry, Shakeel , Schirmer, Clemens M. , Ringer, Andrew J. , Spiotta, Alejandro M , collaborators, STAR and ENRG, Savastano, Luis E., Gomez-Paz, Santiago , Crosa, Roberto , Levitt, Michael R , De Leacy, Reade , Schirmer, Clemens M , Almallouhi, Eyad , Hafeez, Muhammad U , Wolfe, Stacey Quintero , Fragata, Isabel , Howard, Brian M , Alawieh, Ali M , Ogilvy, Christopher S , Jabbour, Pascal , Saini, Vasu A , Fargen, Kyle M , Arthur, Adam Stephen , Goyal, Nitin , Cawley, Michael, Savastano, Luis , Levy, Elad I. , Waqas, Muhammad, Mokin, Maxim , Mascitelli, Justin R , Yoo, Albert J. , Grande, Andrew Walker , Psychogios, Marios‐Nikos , Majmundar, Neil J. , Al‐Mufti, Fawaz , Mocco, J , Park, Minhee , collaborators, STAR and ENRG

Mayo Clinic

Neurosurgery | August 24, 2020 | Volume: 87 | Issue: 6 | Pages: E697-E699

10.1093/neuros/nyaa415 | PMID 32893855 Get It

The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil
Bendok, Bernard R. , Abi-Aad, Karl R., Ward, Jennifer , Kniss, Jason F , Kwasny, Mary , Rahme, Rudy J. , Aoun, Salah G. , Tecle, Najib E. El , Zammar, Samer G. , Aoun, Rami James N. , Patra, Devi Prasad, Raymond, Jean , Woo, Henry H. , Dabus, Guilherme , Milot, Geneviève , Scott, John A. , DeNardo, Andrew , Investigators, HEAT Study, Lavine, Sean D., Bozorgchami, Hormozd, Veznedaroglu, Erol, Albuquerque, Felipe C. , Fiorella, David, Boulos, Alan S. , Cortes, Maria, Kanaan, Hilal, Jindal, Gaurav , Klucznik, Richard , Kalmes, David, Xavier, Andrew, Hussain, Muhammad , Moran, Christopher J. , Adel, Brian van , Milot, Genevieve, Hirsch, Joshua A , Carpenter, Jeffrey , Powers, Ciarán J. , Luh, George, Tummala, Ramanchandra, Evans, Avery J. , Garg, Ankur, James, Roberts, Sauvageau, Eric , Fields, Jeremy D. , Grobelny, Thomas, Hartman, J., Patra, Devi P. , Bendok, Bernard R , Ward, Jennifer D, Ahmadieh, Tarek Y. El , Ansari, Sameer A. , Fiorella, David , Dabus, Guilherme C. , Almandoz, Josser E Delgado , Dashti, Shervin R , Investigators, HEAT Study, Deshaies, Eric Michael , Fiorella, David, Tawk, Rabih G. , Romero, Charles, Kelly, Michael , Chaudry, Imran , Pandey, Aditya S , Wang, Dennis Y.Q. , Milot, Genevieve, Jabbour, Pascal , Shankar, Jai , Patsalides, Athos T , Lee, Sung , James, Robert F. , Jayaraman, Mahesh V. , Satti, Sudhakar R

Mayo Clinic

Neurosurgery | February 10, 2020 | Volume: 86 | Issue: 5 | Pages: 615-624

10.1093/neuros/nyaa006 | PMID 32078692 Get It

Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract
Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience
Srinivasan, Visish M. , Spiotta, Alejandro M , Hendricks, Benjamin K , Ducruet, Andrew F. , Albuquerque, Felipe C. , Puri, Ajit S , Cooke, Daniel L. , Ogilvy, Christopher S. , Enríquez-Marulanda, Alejandro , Rai, Ansaar , Boo, SoHyun , Carlson, Andrew P. , Crowley, R. Webster , Rangel-Castilla, Leonardo , Díaz, Orlando , Bohnstedt, Bradley N. , O’Connor, Kyle P. , Burkhardt, Jan‐Karl , Johnson, Jeremiah N., Chen, Stephen , Kan, Peter , Ogilvy, Christopher S , Srivatsan, Aditya , Amans, Matthew R. , Hetts, Steven W. , Thomas, Ajith J , Rangel-Castilla, Leonardo , Lanzino, Giuseppe , Chen, Peng R

Mayo Clinic

Journal of Neurosurgery | December 13, 2019 | Volume: 133 | Issue: 6 | Pages: 1756-1765

10.3171/2019.5.jns19313 | PMID 31703202 Get It

OBJECTIVE Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications. RESULTS A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A 1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist’s armamentarium, especially with regard to its off-label use.
Staged Percutaneous Intervention for Concurrent Chronic Total Occlusions in Patients With ST‐Segment–Elevation Myocardial Infarction: A Systematic Review and Meta‐Analysis
Villablanca, Pedro , Olmedo, Wilman, Weinreich, Michael , Kassas, Ibrahim, Briceño, David , Sanina, Cristina , Brevik, Thomas, Ong, Emily , Attubato, Michael , Menegus, Mark, Wiley, José , Ramakrishna, Harish , Gupta, Tanush , Mohananey, Divyanshu , Albuquerque, Felipe N. , Kalra, Ankur

Mayo Clinic

Journal of the American Heart Association | April 13, 2018 | Volume: 7 | Issue: 8 | Pages: No page available

10.1161/jaha.117.008415 | PMID 29654206 Get It

Background Studies have shown that chronic total occlusion ( CTO ) in a noninfarct‐related artery in patients with ST‐segment–elevation myocardial infarction is linked to increased mortality. It remains unclear whether staged revascularization of a noninfarct‐related artery CTO in patients with ST‐segment–elevation myocardial infarction translates to improved outcomes. We performed a meta‐analysis to compare outcomes between patients presenting with ST‐segment–elevation myocardial infarction with concurrent CTO who underwent percutaneous coronary intervention of noninfarct‐related artery CTO versus those who did not. Method and Results We conducted an electronic database search of all published data. The primary end point was major adverse cardiovascular events. Secondary end points were all‐cause mortality, cardiovascular mortality, myocardial infarction, repeat revascularization with either percutaneous coronary intervention or coronary artery bypass grafting, stroke, and heart failure readmission. Odds ratios ( ORs ) and 95% confidence intervals ( CIs ) were computed. Random effects model was used and heterogeneity was considered if I 2 >25. Six studies (n=1253 patients) were included in the analysis. There was a significant difference in major adverse cardiovascular events ( OR , 0.54; 95% CI , 0.32–0.91), cardiovascular mortality ( OR , 0.43; 95% CI , 0.20–0.95), and heart failure readmissions ( OR , 0.57; 95% CI , 0.36–0.89), favoring the patients in the CTO percutaneous coronary intervention group. No significant differences were observed between the 2 groups for all‐cause mortality ( OR , 0.47; 95% CI , 0.22–1.00), myocardial infarction ( OR , 0.78; 95% CI , 0.41–1.46), repeat revascularization ( OR , 1.13; 95% CI , 0.56–2.27), and stroke ( OR , 0.51; 95% CI , 0.20–1.33). Conclusions In this meta‐analysis, CTO percutaneous coronary intervention of the noninfarct‐related artery in patients presenting with ST‐segment–elevation myocardial infarction was associated with a significant reduction in major adverse cardiovascular events, cardiovascular mortality, and heart failure readmissions.
Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial
Becske, Tibor , Brinjikji, Waleed , Potts, Matthew B. , Kallmes, David F. , Shapiro, Maksim , Moran, Christopher J. , McDougall, Cameron G. , Szikora, István , Woo, Henry H. , Siddiqui, Adnan H. , Albuquerque, Felipe C. , Saatçi, Işıl , Cekirge, Saruhan H., Berez, Aaron L., Cher, Daniel , Berentei, Zsolt, Nelson, Peter K. , Levy, Elad I. , Lanzino, Giuseppe , Lopes, Demetrius K. , Fiorella, David , Marosföi, Miklós , Siddiqui, Adnan H , Szikora, Istvan

Mayo Clinic

Neurosurgery | February 5, 2017 | Volume: 80 | Issue: 1 | Pages: 40-48

10.1093/neuros/nyw014 | PMID 28362885 Get It

Abstract BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: To present 5-yr follow-up for patients treated in the Pipeline for Uncoilable or Failed Aneurysms clinical trial. METHODS: In our prospective, multicenter trial, 109 complex internal carotid artery (ICA) aneurysms in 107 subjects were treated with the PED. Patients were followed per a standardized protocol at 180 d and 1, 3, and 5 yr. Aneurysm occlusion, in-stent stenosis, modified Rankin Scale scores, and complications were recorded. RESULTS: The primary endpoint of complete aneurysm occlusion at 180 d (73.6%) was previously reported. Aneurysm occlusion for those patients with angiographic follow-up progressively increased over time to 86.8% (79/91), 93.4% (71/76), and 95.2% (60/63) at 1, 3, and 5 yr, respectively. Six aneurysms (5.7%) were retreated. New serious device-related events at 1, 3, and 5 yr were noted in 1% (1/96), 3.5% (3/85), and 0% (0/81) of subjects. There were 4 (3.7%) reported deaths in our trial. Seventy-eight (96.3%) of 81 patients with 5-yr clinical follow-up had modified Rankin Scale scores ≤2. No delayed neurological deaths or hemorrhagic or ischemic cerebrovascular events were reported beyond 6 mo. No recanalization of a previously occluded aneurysm was observed. CONCLUSION: Our 5-yr findings demonstrate that PED is a safe and effective treatment for large and giant wide-necked aneurysms of the intracranial ICA, with high rates of complete occlusion and low rates of delayed adverse events.
Pipeline for uncoilable or failed aneurysms: 3-year follow-up results
Becske, Tibor , Potts, Matthew B. , Shapiro, Maksim , Kallmes, David F. , Brinjikji, Waleed , Saatçi, Işıl , McDougall, Cameron G. , Szikora, István , Moran, Christopher J. , Woo, Henry H. , Berez, Aaron L., Cher, Daniel , Siddiqui, Adnan H. , Albuquerque, Felipe C. , Berentei, Zsolt, Marosföi, Miklós , Cekirge, Saruhan H., Nelson, Peter K. , Lanzino, Giuseppe , Lopes, Demetrius K. , Levy, Elad I. , Fiorella, David , Siddiqui, Adnan H , Szikora, Istvan

Mayo Clinic

Journal of Neurosurgery | October 14, 2016 | Volume: 127 | Issue: 1 | Pages: 81-88

10.3171/2015.6.jns15311 | PMID 27739944 Get It

OBJECTIVEThe long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODSThe PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTSAt 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONSPipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)
Neuroophthalmological outcomes associated with use of the Pipeline Embolization Device: analysis of the PUFS trial results
Sahlein, Daniel H. , Fouladvand, Mohammad, Becske, Tibor , Saatçi, Işıl , McDougall, Cameron G. , Szikora, István , Moran, Christopher J. , Woo, Henry H. , Berez, Aaron L., Cher, Daniel , Siddiqui, Adnan H. , Albuquerque, Felipe C. , Berentei, Zsolt, Marosföi, Miklós , Cekirge, Saruhan H., Kallmes, David F. , Nelson, Peter K. , Lanzino, Giuseppe , Lopes, Demetrius K. , Levy, Elad I. , Fiorella, David , Siddiqui, Adnan H , Szikora, Istvan

Mayo Clinic

Journal of Neurosurgery | July 10, 2015 | Volume: 123 | Issue: 4 | Pages: 897-905

10.3171/2014.12.jns141777 | PMID 26162031 Get It

OBJECT Neuroophthalmological morbidity is commonly associated with large and giant cavernous and supraclinoid internal carotid artery (ICA) aneurysms. The authors sought to evaluate the neuroophthalmological outcomes after treatment of these aneurysms with the Pipeline Embolization Device (PED). METHODS The Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial was an international, multicenter prospective trial evaluating the safety and efficacy of the PED. All patients underwent complete neuroophthalmological examinations both before the PED procedure and at a 6-month follow-up. All examinations were performed for the purpose of this study and according to study criteria. RESULTS In total, 108 patients were treated in the PUFS trial, 98 of whom had complete neuroophthalmological follow-up. Of the patients with complete follow-up, 39 (40%) presented with a neuroophthalmological baseline deficit that was presumed to be attributable to the aneurysm, and patients with these baseline deficits had significantly larger aneurysms. In 25 of these patients (64%), the baseline deficit showed at least some improvement 6 months after PED treatment, whereas in 1 patient (2.6%), the deficits only worsened. In 5 patients (5%), new deficits had developed at the 6-month follow-up, while in another 6 patients (6%), deficits that were not originally assumed to be related to the aneurysm had improved by that time. A history of diabetes was associated with failure of the baseline deficits to improve after the treatment. The aneurysm maximum diameter was significantly larger in patients with a new deficit or a worse baseline deficit at 6 months postprocedure. CONCLUSIONS Patients treated with the PED for large and giant ICA aneurysms had excellent neuroophthalmological outcomes 6 months after the procedure, with deficits improving in most of the patients, very few deficits worsening, and few new deficits developing.