OBJECTIVE The objective was to evaluate the trajectories of hematoma resolution and functional improvement after middle meningeal artery embolization (MMAE) for chronic subdural hematoma (cSDH), model the temporal pattern of cSDH resolution, and identify factors associated with favorable outcomes. METHODS This real-world multicenter retrospective study included cSDH patients treated with MMAE at 24 centers between 2019 and 2024. Hematoma thickness was measured at baseline and at follow-up intervals (1–4 weeks, 1–3 months, 3–6 months, 6–12 months, and > 12 months after embolization). Resolution patterns were modeled using exponential decay functions. Modified Rankin Scale (mRS) scores assessed functional outcomes. Good functional outcome was defined as mRS score ≤ 2. Resolution patterns were modeled using exponential decay functions to estimate time to 50% and 80% reduction. Patients were categorized as complete resolution (≥ 99%) or by quartile of the remaining distribution (substantial [73%–98%], moderate [53%–73%], partial [27%–53%], minimal [< 27%]). The primary outcome was good functional status (mRS score ≤ 2). RESULTS The authors analyzed a total of 1781 patients with 2295 cSDHs who underwent MMAE. The mean ± SD age was 72.8 ± 12.4 years and 68.1% of patients were male. The initial mean hematoma thickness was 15.31 ± 6.53 mm, decreasing to 5.24 ± 5.91 mm at final follow-up (mean reduction 64.3% ± 42.1%). Resolution followed an exponential decay pattern, with an estimated time to 50% reduction of 1.8 months and to 80% reduction of 8.9 months. Complete resolution occurred in 1031 of 2224 patients (46.4%) with complete follow-up. The median (IQR) mRS score improved from 1 (0–3) at baseline to 0 (0–2) at > 12 months. Good functional outcomes were more common in patients with complete versus minimal resolution (68.9% vs 35.0%, p < 0.001). Achieving ≥ 73% resolution within 90 days was associated with better outcomes (good outcome in 76.9% of those with ≥ 73% resolution vs 67.3% in those without, p < 0.001). Neurological deterioration was the strongest predictor of lack of good outcome (23.7% in patients with neurological deterioration vs 82.4% without, p < 0.001). CONCLUSIONS After MMAE for cSDH, reduction in hematoma thickness follows a predictable exponential decay pattern. Greater extent (≥ 80%) and faster timing (within 90 days) of resolution are valuable prognostic indicators. Functional outcomes improve progressively through 6–12 months after the procedure. The relationship between resolution extent and functional outcomes provides quantitative benchmarks for evaluating treatment response.
Woven EndoBridge Device for Ruptured vs. Unruptured Aneurysms: Insights from the WorldWideWEB Study
No container title available | March 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available
Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
Abstract 245: Super‐Large‐Bore vs Large‐Bore Aspiration Catheters in Mechanical Thrombectomy: A Multicenter Propensity‐Matched Analysis
Stroke: Vascular and Interventional Neurology | December 2, 2025 | Volume: 5 | Issue: S1 | Pages: No page available
Background Contact aspiration remains a frontline approach for mechanical thrombectomy (MT) in acute ischemic stroke (AIS). Early evidence correlates catheter size with procedural efficiency and clinical outcomes. Larger‐bore (LB) aspiration catheters may enhance clot ingestion, increase aspiration force, and facilitate faster and more complete recanalization. However, the transition from standard LB catheters (0.068‐0.072″) to super‐large‐bore (SLB, ≥0.080″) devices has raised questions regarding both safety and clinical benefit. Although the use of SLB catheters is increasing, comparative data on their performance versus LB catheters remain limited. This study aims to evaluate the safety and efficacy of SLB compared with LB catheters including data from a large multicenter international registry. Methods We retrospectively analyzed patients with AIS due to LVO treated at 46 international stroke centers between January 2013 and June 2025. Among eligible patients, propensity score matching (PSM) at a 5:1 ratio was used to balance baseline characteristics between those treated with standard LB catheters and those treated with SLB catheters. Safety endpoints included intraprocedural complications, symptomatic intracranial hemorrhage (sICH), distal embolization, and 90‐day mortality. Efficacy endpoints included functional independence at 90 days (modified Rankin Scale [mRS] 0‐2), successful recanalization (TICI ≥2b), first‐pass effect (TICI ≥2b on the first aspiration attempt), and procedural timing to TICI2b. Results A total of 3,100 patients were included (LB n=3,024; SLB n=67). After PSM (LB n=335; SLB n=67), safety outcomes were comparable between groups in terms of intraprocedural complications occurred (p=0.5), sICH (p>0.9), embolization to new territory (p=0.2), and 90‐day mortality (p>0.9). Efficacy outcomes were similarly consistent for functional independence (mRS 0‐2) (p>0.9), successful recanalization (p>0.9), first‐pass effect (p=0.5), and time to TICI ≥2b (27.6 vs. 24.5 minutes; p=0.9). These findings remained consistent in the subgroup with ICA and M1 occlusions, with no significant differences in safety (intraprocedural complications [p=0.4], sICH [p>0.9], embolization to new territory [p=0.6], or 90‐day mortality [p>0.9], nor in efficacy outcomes (functional independence at 90 days [p>0.9], successful recanalization [p=0.9], first‐pass effect [p=0.6], and time to TICI ≥2b [p=0.9]). Conclusion In this large multicenter analysis, the use of SLB aspiration catheters demonstrated comparable safety and efficacy to standard LB catheters for MT in AIS. Despite theoretical advantages in aspiration dynamics, SLB devices did not confer significant procedural or clinical benefit over LB catheters. These findings suggest that while SLB catheters are a feasible alternative, technical and clinical outcomes remain comparable to LB catheters. Further prospective studies are warranted to clarify potential clinical advantages. image
Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach
Interventional Neuroradiology | November 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available
Background The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.
Predictors of Intracranial Aneurysm Residual Filling After Treatment With Flow Diversion at Early Follow-up: A Multicenter Experience of 2277 Patients
BACKGROUND AND OBJECTIVES: Flow-diverting stents (FDSs) have improved treatment options for intracranial aneurysms. Although FDS have proven successful in treating aneurysms that would previously have required complex microsurgical or endovascular repairs, treatment failures remain a concern. In this multicenter study, we aim to analyze the predictors of residual aneurysmal filling at early angiographic follow-up. METHODS: A retrospective analysis of a prospectively maintained neuroendovascular database at 14 high-volume US centers was conducted for all patients who underwent FDS placement for intracranial aneurysms between 2011 and 2019. Aneurysms were graded on the O'Kelly-Marotta scale (OKM). RESULTS: A total of 2277 patients underwent FDS embolization for intracranial aneurysms during the study period. The patient's mean age was 55 (SD ± 13.5) years, and 82% were female. The median maximal aneurysm diameter was 6.7 mm (IQR 4.10-11 mm). Complete aneurysm obliteration (OKM grade 4) occurred in 1109 patients (68%), and 146 (9%) were OKM grade 3, 188 (12%) were OKM grade 2, and 174 (11%) were OKM grade 1. In the adjusted multivariate analysis, individuals in the 65-74 years and 75+ years age groups had significantly increased risk of residual aneurysm filling at 6-month follow-up compared with the 18-44 years age group (odds ratio [OR] 1.92 (95% CI: 1.33-2.78) and 2.92 (95% CI: 1.79-4.77), respectively). Aneurysms arising from the superior cerebellar artery, the basilar artery, and the carotid terminus were more likely to have a residual filling (OR 12.6, 95% CI: 1.39–14.7; OR 4.27, 95% CI: 1.39–14.7; OR 3.16, 95% CI: 1.24–8.06, respectively). CONCLUSION: As the utilization of FDS for intracranial aneurysms becomes more widespread, the efficacy of aneurysm obliteration needs to be assessed. Our results indicate that several patient-dependent factors, such as age, aneurysm location, and size, predict the likelihood of residual aneurysm filling 6 months post-treatment.
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Journal of NeuroInterventional Surgery | April 30, 2025 | Volume: 18 | Issue: 3 | Pages: 782-789
Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study
Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740
OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
EXCELLENT Registry: A Prospective, Multicenter, Global Registry of Endovascular Stroke Treatment With the EMBOTRAP Device
BACKGROUND: The EXCELLENT registry aimed to evaluate the effectiveness of the EMBOTRAP Revascularization Device in an all-comer population in a real-world setting, with a focus on the composition of retrieved clots. METHODS: EXCELLENT is a prospective, global registry of patients with acute ischemic stroke treated with EMBOTRAP as the first-line mechanical thrombectomy device conducted at 34 sites (25 sites contributing clot) from September 2018 to March 2021, utilizing core imaging and central histology laboratories blinded to clinical data, independent 90-day modified Rankin Scale assessment and Clinical Events Committee. RESULTS: After screening 3799 patients, a total of 997 subjects (mean age, 70.0±14.2 years; 51.8% women; 19.7% non-White) were included. The first-pass modified Treatment in Cerebral Infarction (mTICI) ≥2b rate was 64.5% (623/966), first-pass mTICI ≥2c was 39.1% (378/966), and final mTICI ≥2b was 94.5% (931/985). A total of 427/912 (46.8%) patients achieved a 90-day modified Rankin Scale of 0 to 2 or ≤baseline. Embolization to a new territory occurred in 0.2% (2/984), and symptomatic intracranial hemorrhage at 24 hours in 1.6% (16/997). The 90-day mortality was 19.1% (175/918). Device- and/or procedure-related serious adverse events occurred in 5.9% (54/912) through 90 days. The mean RBC percentage of retrieved clots was 45.62±21.372. Among patients who achieved mTICI ≥2b with the first pass, 15.7% (52/331) and 9.7% (32/331), respectively, had RBC-poor (<25%) and RBC-rich (>75%) clots. Patients with no clot retrieved in any procedural pass had a lower percentage of hyperdense or susceptibility vessel sign on baseline imaging (58.9% versus 74.7%; P <0.001), pointing to a potential preprocedure indicator of challenging clot. CONCLUSIONS: The EXCELLENT registry informs real-world practices in mechanical thrombectomy and sheds light on the range of clots effectively retrieved by current technology. This is the first report of detailed patient characteristics where mechanical thrombectomy maneuvers failed to remove any clot material. Although the composition of nonretrievable clots cannot be assessed histologically, the results support the notion that no retrieval may be correlated with imaging findings suggesting clots lower in RBC. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03685578.
OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database
Interventional Neuroradiology | August 10, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available
Background Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.