Back to Authors

Diestro, Jose Danilo Bengzon

https://orcid.org/0000-0001-8450-2021

A5009503380 | I1297363086

Mayo Clinic

St. Michael's Hospital

Citations 14

Temporal relationship between hematoma resolution and functional recovery after middle meningeal artery embolization for chronic subdural hematoma

Journal of Neurosurgery | May 20, 2026 | Volume: No volume available | Issue: No issue available | Pages: 1-12

10.3171/2025.12.jns251884 | PMID 42172679

OBJECTIVE The objective was to evaluate the trajectories of hematoma resolution and functional improvement after middle meningeal artery embolization (MMAE) for chronic subdural hematoma (cSDH), model the temporal pattern of cSDH resolution, and identify factors associated with favorable outcomes. METHODS This real-world multicenter retrospective study included cSDH patients treated with MMAE at 24 centers between 2019 and 2024. Hematoma thickness was measured at baseline and at follow-up intervals (1–4 weeks, 1–3 months, 3–6 months, 6–12 months, and > 12 months after embolization). Resolution patterns were modeled using exponential decay functions. Modified Rankin Scale (mRS) scores assessed functional outcomes. Good functional outcome was defined as mRS score ≤ 2. Resolution patterns were modeled using exponential decay functions to estimate time to 50% and 80% reduction. Patients were categorized as complete resolution (≥ 99%) or by quartile of the remaining distribution (substantial [73%–98%], moderate [53%–73%], partial [27%–53%], minimal [< 27%]). The primary outcome was good functional status (mRS score ≤ 2). RESULTS The authors analyzed a total of 1781 patients with 2295 cSDHs who underwent MMAE. The mean ± SD age was 72.8 ± 12.4 years and 68.1% of patients were male. The initial mean hematoma thickness was 15.31 ± 6.53 mm, decreasing to 5.24 ± 5.91 mm at final follow-up (mean reduction 64.3% ± 42.1%). Resolution followed an exponential decay pattern, with an estimated time to 50% reduction of 1.8 months and to 80% reduction of 8.9 months. Complete resolution occurred in 1031 of 2224 patients (46.4%) with complete follow-up. The median (IQR) mRS score improved from 1 (0–3) at baseline to 0 (0–2) at > 12 months. Good functional outcomes were more common in patients with complete versus minimal resolution (68.9% vs 35.0%, p < 0.001). Achieving ≥ 73% resolution within 90 days was associated with better outcomes (good outcome in 76.9% of those with ≥ 73% resolution vs 67.3% in those without, p < 0.001). Neurological deterioration was the strongest predictor of lack of good outcome (23.7% in patients with neurological deterioration vs 82.4% without, p < 0.001). CONCLUSIONS After MMAE for cSDH, reduction in hematoma thickness follows a predictable exponential decay pattern. Greater extent (≥ 80%) and faster timing (within 90 days) of resolution are valuable prognostic indicators. Functional outcomes improve progressively through 6–12 months after the procedure. The relationship between resolution extent and functional outcomes provides quantitative benchmarks for evaluating treatment response.
Woven EndoBridge Device for Ruptured vs. Unruptured Aneurysms: Insights from the WorldWideWEB Study

No container title available | March 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-8939206/v1

Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry

Journal of NeuroInterventional Surgery | April 30, 2025 | Volume: 18 | Issue: 3 | Pages: 782-789

10.1136/jnis-2024-022628 | PMID 40306928

Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study

Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740

10.3171/2024.10.jns241058 | PMID 39889291

OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
Defining ideal middle cerebral artery bifurcation aneurysm size for Woven EndoBridge embolization

Journal of Neurosurgery | October 12, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-11

10.3171/2024.5.jns232204 | PMID 39393093

OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.
Creation of a predictive calculator to determine adequacy of occlusion of the woven endobridge (WEB) device in intracranial aneurysms—A retrospective analysis of the WorldWide WEB Consortium database

Interventional Neuroradiology | August 10, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199241267320 | PMID 39127463

Background Endovascular treatment with the woven endobridge (WEB) device has been widely utilized for managing intracranial aneurysms. However, predicting the probability of achieving adequate occlusion (Raymond–Roy classification 1 or 2) remains challenging. Objective Our study sought to develop and validate a predictive calculator for adequate occlusion using the WEB device via data from a large multi-institutional retrospective cohort. Methods We used data from the WorldWide WEB Consortium, encompassing 356 patients from 30 centers across North America, South America, and Europe. Bivariate and multivariate regression analyses were performed on a variety of demographic and clinical factors, from which predictive factors were selected. Calibration and validation were conducted, with variance inflation factor (VIF) parameters checked for collinearity. Results A total of 356 patients were included: 124 (34.8%) were male, 108 (30.3%) were elderly (≥65 years), and 118 (33.1%) were current smokers. Mean maximum aneurysm diameter was 7.09 mm (SD 2.71), with 112 (31.5%) having a daughter sac. In the multivariate regression, increasing aneurysm neck size (OR 0.706 [95% CI: 0.535–0.929], p = 0.13) and partial aneurysm thrombosis (OR 0.135 [95% CI: 0.024–0.681], p = 0.016) were found to be the only statistically significant variables associated with poorer likelihood of achieving occlusion. The predictive calculator shows a c-statistic of 0.744. Hosmer–Lemeshow goodness-of-fit test indicated a satisfactory model fit with a p-value of 0.431. The calculator is available at: https://neurodx.shinyapps.io/WEBDEVICE/ . Conclusion The predictive calculator offers a substantial contribution to the clinical toolkit for estimating the likelihood of adequate intracranial aneurysm occlusion by WEB device embolization.
Association of preprocedural antiplatelet use with decreased thromboembolic complications for intracranial aneurysms undergoing intrasaccular flow disruption

Journal of Neurosurgery | May 3, 2024 | Volume: 141 | Issue: 4 | Pages: 992-999

10.3171/2024.2.jns232918 | PMID 38701528

OBJECTIVE This study was conducted to investigate the impact of antiplatelet administration in the periprocedural period on the occurrence of thromboembolic complications (TECs) in patients undergoing treatment using the Woven EndoBridge (WEB) device for intracranial wide-necked bifurcation aneurysms. The primary objective was to assess whether the use of antiplatelets in the pre- and postprocedural phases reduces the likelihood of developing TECs, considering various covariates. METHODS A retrospective multicenter observational study was conducted within the WorldWideWEB Consortium and comprised 38 academic centers with endovascular treatment capabilities. Univariable and multivariable logistic regression analyses were performed to determine the association between antiplatelet use and TECs, adjusting for covariates. Missing predictor data were addressed using multiple imputation. RESULTS The study comprised two cohorts: one addressing general thromboembolic events and consisting of 1412 patients, among whom 103 experienced TECs, and another focusing on symptomatic thromboembolic events and comprising 1395 patients, of whom 50 experienced symptomatic TECs. Preprocedural antiplatelet use was associated with a reduced likelihood of overall TECs (OR 0.32, 95% CI 0.19–0.53, p < 0.001) and symptomatic TECs (OR 0.49, 95% CI 0.25–0.95, p = 0.036), whereas postprocedural antiplatelet use showed no significant association with TECs. The study also revealed additional predictors of TECs, including stent use (overall: OR 4.96, 95% CI 2.38–10.3, p < 0.001; symptomatic: OR 3.24, 95% CI 1.26–8.36, p = 0.015), WEB single-layer sphere (SLS) type (overall: OR 0.18, 95% CI 0.04–0.74, p = 0.017), and posterior circulation aneurysm location (symptomatic: OR 18.43, 95% CI 1.48–230, p = 0.024). CONCLUSIONS The findings of this study suggest that the preprocedural administration of antiplatelets is associated with a reduced likelihood of TECs in patients undergoing treatment with the WEB device for wide-necked bifurcation aneurysms. However, postprocedural antiplatelet use did not show a significant impact on TEC occurrence.
First pass effect as an independent predictor of functional outcomes in medium vessel occlusions: An analysis of an international multicenter study

European Stroke Journal | October 27, 2023 | Volume: 9 | Issue: 1 | Pages: 114-123

10.1177/23969873231208276 | PMID 37885243

Abstract Introduction: First pass effect (FPE), achievement of complete recanalization (mTICI 2c/3) with a single pass, is a significant predictor of favorable outcomes for endovascular treatment (EVT) in large vessel occlusion stroke (LVO). However, data concerning the impact on functional outcomes and predictors of FPE in medium vessel occlusions (MeVO) are scarce. Patients and Methods: We conducted an international retrospective study on MeVO cases. Multivariable logistic modeling was used to establish independent predictors of FPE. Clinical and safety outcomes were compared between the two study groups (FPE vs non-FPE) using logistic regression models. Good outcome was defined as modified Rankin Scale 0–2 at 3 months. Results: Eight hundred thirty-six patients with a final mTICI ⩾ 2b were included in this analysis. FPE was observed in 302 patients (36.1%). In multivariable analysis, hypertension (aOR 1.55, 95% CI 1.10–2.20) and lower baseline NIHSS score (aOR 0.95, 95% CI 0.93–0.97) were independently associated with an FPE. Good outcomes were more common in the FPE versus non-FPE group (72.8% vs 52.8%), and FPE was independently associated with favorable outcome (aOR 2.20, 95% CI 1.59–3.05). 90-day mortality and intracranial hemorrhage (ICH) were significantly lower in the FPE group, 0.43 (95% CI, 0.25–0.72) and 0.55 (95% CI, 0.39–0.77), respectively. Conclusion: Over 2/3 of patients with MeVOs and FPE in our cohort had a favorable outcome at 90 days. FPE is independently associated with favorable outcomes, it may reduce the risk of any intracranial hemorrhage, and 3-month mortality.
Stent-assisted Woven EndoBridge device for the treatment of intracranial aneurysms: an international multicenter study

Journal of Neurosurgery | October 21, 2023 | Volume: 140 | Issue: 4 | Pages: 1071-1079

10.3171/2023.8.jns235 | PMID 37862717

OBJECTIVE The Woven EndoBridge (WEB) device is an intrasaccular flow disruptor designed for wide-necked bifurcation aneurysms. These aneurysms may require the use of a concomitant stent. The objective of this study was to determine the clinical and radiological outcomes of patients undergoing stent-assisted WEB treatment. In addition, the authors also sought to determine the predictors of a concomitant stent in aneurysms treated with the WEB device. METHODS The data for this study were taken from the WorldWideWEB Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups based on treatment: stent-assisted WEB and WEB device alone. The authors compared clinical and radiological outcomes of both groups. Univariable and multivariable binary logistic regression analyses were performed to determine factors that predispose to stent use. RESULTS The study included 691 intracranial aneurysms (31 with stents and 660 without stents) treated with the WEB device. The adequate occlusion status did not differ between the two groups at the latest follow-up (83.3% vs 85.6%, p = 0.915). Patients who underwent stenting had more thromboembolic (32.3% vs 6.5%, p < 0.001) and procedural (16.1% vs 3.0%, p < 0.001) complications. Aneurysms treated with a concomitant stent had wider necks, greater heights, and lower dome-to-neck ratios. Increasing neck size was the only significant predictor for stent use. CONCLUSIONS This study demonstrates that there is no difference in the degree of aneurysm occlusion between the two groups; however, complications were more frequent in the stent group. In addition, a wider aneurysm neck predisposes to stent assistance in WEB-treated aneurysms.
Aspiration Versus Stent‐Retriever as First‐Line Endovascular Therapy Technique for Primary Medium and Distal Intracranial Occlusions: A Propensity‐Score Matched Multicenter Analysis

Stroke: Vascular and Interventional Neurology | July 6, 2023 | Volume: 3 | Issue: 6 | Pages: No page available

10.1161/svin.123.000931 | PMID 41585056

Background For acute proximal intracranial artery occlusions, contact aspiration may be more effective than stent‐retriever for first‐line reperfusion therapy. Due to the lack of data regarding medium vessel occlusion thrombectomy, we evaluated outcomes according to first‐line technique in a large, multicenter registry. Methods Imaging, procedural, and clinical outcomes of patients with acute proximal medium vessel occlusions (M2, A1, or P1) or distal medium vessel occlusions (M3, A2, P2, or further) treated at 37 sites in 10 countries were analyzed according to first‐line endovascular technique (stent‐retriever versus aspiration). Multivariable logistic regression and propensity‐score matching were used to estimate the odds of the primary outcome, expanded Thrombolysis in Cerebral Infarction score of 2b–3 (“successful recanalization”), as well as secondary outcomes (first‐pass effect, expanded Thrombolysis in Cerebral Infarction 2c‐3, intracerebral hemorrhage, and 90‐day modified Rankin scale, 90‐day mortality) between treatment groups. Results Of the 440 included patients (44.5% stent‐retriever versus 55.5% aspiration), those treated with stent‐retriever had lower baseline Alberta Stroke Program Early Computed Tomography Scale scores (median 8 versus 9; P <0.01), higher National Institutes of Health Stroke Scale scores (median 13 versus 11; P =0.02), and nonsignificantly fewer medium‐distal occlusions (M3, A2, P2, or other: 17.4% versus 23.8%; P =0.10). Use of a stent‐retriever was associated with 15% lower odds of successful recanalization (odds ratio [OR], 0.85; [95% CI 0.74–0.98]; P =0.02), but this was not significant after multivariable adjustment in the total cohort (adjusted OR, 0.88; [95% CI 0.72–1.09]; P =0.24), or in the propensity‐score matched cohort (n=105 in each group) (adjusted OR, 0.94; [95% CI 0.75–1.18]; P =0.60). There was no significant association between technique and secondary outcomes in the propensity‐score matched adjusted models. Conclusion In this large, diverse, multinational medium vessel occlusion cohort, we found no significant difference in imaging or clinical outcomes with aspiration versus stent‐retriever thrombectomy.