Background: Despite the well-established potent benefit of mechanical thrombectomy (MT) for large vessel occlusion (LVO) stroke, access to MT has not been studied globally. We conducted a worldwide survey of countries on 6 continents to define MT access (MTA), the disparities in MTA, and its determinants on a global scale. Methods: Our survey was conducted in 75 countries through the Mission Thrombectomy 2020+ global network between November 22, 2020, and February 28, 2021. The primary end points were the current annual MTA, MT operator availability, and MT center availability. MTA was defined as the estimated proportion of patients with LVO receiving MT in a given region annually. The availability metrics were defined as ([current MT operators×50/current annual number of estimated thrombectomy-eligible LVOs]×100 = MT operator availability) and ([current MT centers×150/current annual number of estimated thrombectomy-eligible LVOs]×100= MT center availability). The metrics used optimal MT volume per operator as 50 and an optimal MT volume per center as 150. Multivariable-adjusted generalized linear models were used to evaluate factors associated with MTA. Results: We received 887 responses from 67 countries. The median global MTA was 2.79% (interquartile range, 0.70–11.74). MTA was <1.0% for 18 (27%) countries and 0 for 7 (10%) countries. There was a 460-fold disparity between the highest and lowest nonzero MTA regions and low-income countries had 88% lower MTA compared with high-income countries. The global MT operator availability was 16.5% of optimal and the MT center availability was 20.8% of optimal. On multivariable regression, country income level (low or lower–middle versus high: odds ratio, 0.08 [95% CI, 0.04–0.12]), MT operator availability (odds ratio, 3.35 [95% CI, 2.07–5.42]), MT center availability (odds ratio, 2.86 [95% CI, 1.84–4.48]), and presence of prehospital acute stroke bypass protocol (odds ratio, 4.00 [95% CI, 1.70–9.42]) were significantly associated with increased odds of MTA. Conclusions: Access to MT on a global level is extremely low, with enormous disparities between countries by income level. The significant determinants of MT access are the country’s per capita gross national income, prehospital LVO triage policy, and MT operator and center availability.
The Hydrogel Endovascular Aneurysm Treatment Trial (HEAT): A Randomized Controlled Trial of the Second-Generation Hydrogel Coil
Abstract BACKGROUND Aneurysm recurrence after coiling has been associated with aneurysm growth, (re)hemorrhage, and a greater need for follow-up. The second-generation HydroCoil Embolic System (HES; MicroVention, Inc) consists of a platinum core with integrated hydrogel and was developed to reduce recurrence through enhancing packing density and healing within the aneurysm. OBJECTIVE To compare recurrence between the second-generation HES and bare platinum coil (BPC) in the new-generation Hydrogel Endovascular Aneurysm Treatment Trial (HEAT). METHODS HEAT is a randomized, controlled trial that enrolled subjects with ruptured or unruptured 3- to 14-mm intracranial aneurysms amenable to coiling. The primary endpoint was aneurysm recurrence using the Raymond-Roy scale. Secondary endpoints included minor and major recurrence, packing density, adverse events related to the procedure and/or device, mortality, initial complete occlusion, aneurysm retreatment, hemorrhage from target aneurysm during follow-up, aneurysm occlusion stability, and clinical outcome at final follow-up. RESULTS A total of 600 patients were randomized (HES, n = 297 and BPC, n = 303), including 28% with ruptured aneurysms. Recurrence occurred in 11 (4.4%) subjects in the HES arm and 44 (15.4%) subjects in the BPC arm ( P = .002). While the initial occlusion rate was higher with BPC, the packing density and both major and minor recurrence rates were in favor of HES. Secondary endpoints including adverse events, retreatment, hemorrhage, mortality, and clinical outcome did not differ between arms. CONCLUSION Coiling of small-to-medium aneurysms with second-generation HES resulted in less recurrence when compared to BPC, without increased harm. These data further support the use of the second-generation HES for the embolization of intracranial aneurysms. Video Abstract