Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
CyberKnife Stereotactic Radiosurgery for Vestibular Schwannomas: Systematic Review and Meta-Analysis of Long-Term Tumor Control and Hearing Preservation Outcomes
Neurosurgery Practice | February 2, 2026 | Volume: 7 | Issue: 1 | Pages: No page available
BACKGROUND AND OBJECTIVES: Stereotactic radiosurgery is a popular intervention for small vestibular schwannomas in patients with preserved hearing. Gamma Knife radiosurgery (GKRS) and CyberKnife radiosurgery (CKRS) represent 2 alternative modalities, with CKRS potentially allowing for the delivery of higher doses over multiple sessions. However, the optimal dosing and hearing outcomes of CKRS remain unclear. This study systematically reviewed all literature describing outcomes following treatment of vestibular schwannomas with CKRS, with a focus on tumor control, hearing preservation, and dosing schema. METHODS: The PubMed, Scopus, and Embase databases were queried to identify primary retrospective studies reporting local tumor control and hearing preservation rates following CKRS for vestibular schwannoma. Studies were reviewed, and the systematic review and meta-analysis were performed according to PRISMA and meta-analysis guidelines. RESULTS: Fifteen studies with study periods ranging from 1998 to 2018 were included. These studies comprised 2018 patients (mean age, 60.2 years; range, 11-91 years; 52% female), of whom 64 had neurofibromatosis type 2. The mean follow-up was 40 (range, 6-120) months, and 309 patients had undergone prior treatment (surgery and/or stereotactic radiosurgery). In aggregate, local control at the last follow-up was 96% (95% CI, 95%-98%), and 73% (95% CI, 66%-81%) of patients had preserved hearing. The most common major complications after CKRS were facial neuropathy (1.4%), trigeminal neuralgia (1.3%), and hydrocephalus (0.5%). CKRS provides a high rate of short-term and mid-term tumor control with hearing preservation comparable with GKRS, but long-term outcomes remain under investigated. CONCLUSION: This systematic review and meta-analysis found that CKRS offers high rates of tumor control and hearing preservation in patients undergoing stereotactic radiosurgery for vestibular schwannomas. Current data suggest that CKRS is a reasonable, safe therapeutic option for patients with small tumors and preserved hearing. Further exploration in larger cohorts and direct comparison with GKRS is merited.
Contemporary adverse event profile of microsurgery for intracranial unruptured aneurysms in high-volume microsurgical centers: the international PRAEMIUM study
OBJECTIVE Objective values on procedural risk are essential to facilitate informed consent and optimize clinical decision-making in patients with unruptured intracranial aneurysms (UIAs). While robust heuristics, such as the PHASES (population, hypertension, age, size of aneurysm, earlier subarachnoid hemorrhage, and site of aneurysm) score, are established for predicting rupture risk, contemporary and granular benchmarks for procedural safety remain scarce. The multinational Prediction of Adverse Events After Microsurgery for Intracranial Unruptured Aneurysms (PRAEMIUM) study aims to comprehensively characterize contemporary adverse event rates following microsurgical treatment at high-volume expert centers, stratified by aneurysm location, morphology, and complexity factors to better inform individual risk/benefit analyses. METHODS A cohort study among 20 participating expert centers from 9 countries was established. Patients treated microsurgically for UIAs were included. The authors describe the epidemiology of treated patients and UIAs and a comprehensive adverse event profile using 3 outcomes measured at hospital discharge: 1) poor neurological outcome (modified Rankin Scale score ≥ 3), 2) new sensorimotor neurological deficits, and 3) all-cause adverse events (Clavien-Dindo grade ≥ 1). Subgroup reports were given for aneurysm location, morphology, and complexity factors (prior aneurysm treatment, calcifications, complex angioanatomy involving critical branch vessels or perforators, and thrombosis). The authors purposely chose discharge as the time point to capture early postoperative risks and complications in patients with asymptomatic UIAs, for whom preserving neurological function is paramount. RESULTS The cohort included 3705 patients (mean age 56 [SD 12] years, 28% male). Overall, at discharge 13.9% of patients (95% CI 12.8%–15.0%) had poor neurological functional outcomes, 14.4% (95% CI 13.3%–15.5%) had new sensorimotor deficits, and 24.1% (95% CI 22.8%–25.5%) experienced all-cause adverse events. Poor neurological outcomes ranged from 8.5% (M1 aneurysms) to 37.4% (posterior circulation aneurysms), neurological deficits from 9.3% (distal anterior cerebral artery [ACA] aneurysms) to 34.2% (posterior circulation aneurysms), and all-cause adverse events from 21.2% (distal ACA aneurysms) to 31.3% (posterior circulation aneurysms). Dissecting and fusiform aneurysms showed notably high rates of poor neurological outcomes (22.0%–33.3%), new deficits (25.4%–26.7%), and adverse events (26.7%–37.0%). Complexity factors significantly influenced outcomes, with prior treatment (22.9%, 19.7%, and 30.1%), calcification (16.3%, 18.1%, and 30.5%), complex angioanatomy (13.1%, 15.9%, and 26.9%), and thrombosis (19.6%, 23.9%, and 39.6%) notably increasing the risks for poor neurological outcomes, deficits, and adverse events, respectively. CONCLUSIONS This large international cohort provides contemporary benchmarks for microsurgical treatment of UIAs, emphasizing variability in outcomes based on aneurysm location, morphology, and complexity. The presented granular and quotable adverse event rates support informed patient counseling and individualized risk/benefit assessments in comparable high-volume centers.
Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach
Interventional Neuroradiology | November 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available
Background The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.
Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Journal of NeuroInterventional Surgery | April 30, 2025 | Volume: 18 | Issue: 3 | Pages: 782-789
Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.
Cerebral venous thrombectomy: the new frontier
Journal of NeuroInterventional Surgery | April 23, 2025 | Volume: 17 | Issue: 10 | Pages: 1029-1031
Background Flow-diverter stents (FDS) have become the standard of care for a wide range of intracranial aneurysms, but their efficacy/safety in the context of recurrent/recanalized aneurysms following stent-assisted coiling (SAC) is not well established. We evaluate the outcomes of FDS retreatment in a large multicenter cohort. Methods We retrospectively analyzed data from 118 patients across 22 institutions who underwent FDS retreatment for recurrent/persistent aneurysms after SAC (2008–22). The primary outcome was angiographic occlusion status at last follow-up, categorized as complete (100%), near-complete (90–99%), or incomplete (<90%) occlusion. Secondary outcomes included procedural complications and clinical outcomes measured by the modified Rankin Scale (mRS). Results A total of 118 patients (median age 57, 74.6% female) with median follow-up of 15.3 months were identified. Complete occlusion was achieved in 62.5% and near-complete occlusion in 25%. FDS deployment within the pre-existing stent was successful in 98.3% of cases. Major complications occurred in 3.4% of cases, including postoperative aneurysmal rupture with resultant mortality (1.6%) and thromboembolic events with long-term disability (1.6%). Favorable clinical outcomes (mRS 0–2) were observed in 95.1% of patients. Wider aneurysm neck diameter was a significant predictor of incomplete occlusion (adjusted OR (aOR) 1.23 per mm, P=0.044), with male sex trending towards association with non-occlusion (aOR 3.2, P=0.07), while baseline hypertension was associated with complete occlusion (aOR 0.32, P=0.048). Conclusions FDS treatment for recurrent/residual aneurysms after SAC represents a viable treatment option for these challenging cases with acceptable safety and reasonable occlusion rates, although lower than de novo FDS occlusion rates.
Comparative meta-analysis of microsurgery versus endovascular therapy and bypass versus nonbypass techniques for blister-like aneurysms: enigmas of the supraclinoid internal carotid artery
Journal of Neurosurgery | February 21, 2025 | Volume: 143 | Issue: 1 | Pages: 243-254
OBJECTIVE Blister aneurysms of the internal carotid artery (ICA) have high associated mortality rates and are challenging due to their friable wall and poorly defined neck. Microsurgical and endovascular treatment options have been suggested, including bypass of the parent vessel to exclude the aneurysm. The goal of this study was to evaluate the safety and efficacy of microsurgical versus endovascular interventions. Additionally, for patients treated with open surgery, the outcomes of bypass were compared to nonbypass techniques. METHODS Three databases were systematically queried for primary studies comparing microsurgery to endovascular therapy and assessing bypass versus nonbypass treatment modalities for blister aneurysms of the ICA. All relevant studies published between 2000 and 2023 were eligible for inclusion. All articles were screened against title and abstract by 2 authors, as were those eligible for full-text assessment. Ultimately, relevant data from all included studies were pooled for meta-analysis in which the Mantel-Haenszel method with random-effects modeling was used. RESULTS Among the 504 cases reported across 24 studies, 182 (35.1%) blister aneurysms of the ICA were surgically treated, whereas 337 (64.9%) involved endovascular treatment. There were 235 (46.6%) female patients in the cohort. Functional outcomes were comparable between groups, with 83% of surgically treated patients and 85% of endovascularly treated patients achieving a favorable outcome (p > 0.05). Among the 7 studies (178 patients) comparing bypass to nonbypass microsurgery, rates of postoperative bleeding, ischemic infarct, vasospasm, recurrence, favorable outcomes, and mortality were comparable for bypass (n = 54, 30.3%) and nonbypass groups (n = 124, 69.7%). CONCLUSIONS Blister aneurysms of the ICA are rare intracranial aneurysms that are difficult to treat with microsurgical and endovascular techniques. Considering only patients treated with open surgery, there appears to be no significant difference in complication profile or functional outcomes between patients undergoing bypass or alternative microsurgical techniques. However, it must be noted that the complex nature of bypass procedures means that much of the data granularity is lost on meta-analysis, suggesting that additional investigations comparing bypass to other open microsurgical techniques may be merited. Similarly, future studies should determine the limitations of dual antiplatelet therapy in endovascular treatment and the efficacy of different numbers and types of overlapping, flow-diverting devices.
Impact of smoking on recurrence rates among wide-neck intracranial aneurysms treated with Woven EndoBridge: a multicenter retrospective study
Journal of Neurosurgery | January 31, 2025 | Volume: 142 | Issue: 6 | Pages: 1732-1740
OBJECTIVE Tobacco smoking is among the factors known to significantly augment the risk of untreated intracranial aneurysm (IA) growth and rupture. Smoking appears to have a variable effect on different endovascular treatment modalities. The impact of smoking on the safety, efficacy, and outcomes of Woven EndoBridge (WEB) device use for wide-neck IAs has not been evaluated. This study aimed to investigate the outcomes of WEB devices by smoking status. METHODS A retrospective multicenter analysis was conducted on the data of patients from 36 sites worldwide treated with the WEB device for intracranial saccular aneurysms. Patients were stratified based on smoking status (current, former, and never smokers). The Student t-test and chi-square test were performed for continuous and categorical variables, respectively. Multivariable logistic regression was used to adjust for confounders. RESULTS Of 1376 patients with available smoking status, 504 were current smokers, 358 were former smokers, and 514 were never smokers. Upon adjusting for significant confounders, no association was found between smoking and recurrence outcomes (OR 1.39, 95% CI 0.69–2.80; p = 0.36), thromboembolic and hemorrhagic complications, and mortality among IAs treated with the WEB device. There was no statistically significant difference in outcomes between former and never smokers (OR 1.23, 95% CI 0.70–2.18; p = 0.46). The location of aneurysms differed between smoking groups, with former smokers having more anterior circulation aneurysms compared with current and never smokers (99.0% vs 96.9% vs 95.3%; p = 0.01). In terms of clinical symptoms, headache and dizziness were more common in the never smokers compared with current and former smokers (13.9% vs 8.9% vs 7.7%, p = 0.01). CONCLUSIONS This large-scale study suggests no significant correlation between smoking and the recurrence of IAs treated with the WEB device. Biological studies are warranted to better understand the biological impact of smoking on the growth and rupture of treated IAs.
OBJECTIVE The Woven EndoBridge (WEB) device was approved to treat wide-necked bifurcation aneurysms. The device is designed as an intrasaccular flow disruptor covering aneurysm widths up to 10 mm. Although prior studies combined all aneurysm sizes, it is known that aneurysms behave differently in response to endovascular treatment based on their size. Therefore, the authors’ objective was to identify ideal middle cerebral artery (MCA) aneurysm width and neck sizes most suitable for WEB treatment. METHODS The WorldWideWEB consortium is a large multicenter retrospective database that analyzes intracranial aneurysms treated with the WEB device. In this study, all unruptured MCA bifurcation aneurysms with available measurements were included. Cutoff values based on aneurysm width and neck in relation to aneurysm occlusion status were measured using the receiver operating characteristic (ROC) curve. Propensity score matching (PSM) was then used to compare treatment outcomes between aneurysms smaller and larger than the cutoff value for both width and neck size. RESULTS The ideal cutoff values for MCA bifurcation aneurysm width and neck were 6.1 mm and 4.6 mm, respectively. On PSM, 87 matched pairs were compared based on width size (≤ 6.1 mm and > 6.1 mm), and 77 matched pairs were compared based on neck size (≤ 4.6 mm and > 4.6 mm). There was a significant difference in adequate aneurysm occlusion between aneurysms smaller and larger than those cutoff values for both widths (93% vs 76%, p = 0.0017) and neck sizes (90% vs 70%, p = 0.0026). The retreatment rate was also significantly higher for larger aneurysms in both parameters. CONCLUSIONS This study shows that MCA bifurcation aneurysms ≤ 6.1 mm in width and ≤ 4.6 mm in neck size are significantly better candidates for WEB treatment, leading to improved occlusion status and reduced retreatment rate, which are important considerations when using WEB devices.