Back to Authors

Szikora, István

https://orcid.org/0000-0003-3730-3278

A5062195334 | I4210100950

Mayo Clinic

Országos Idegsebészeti Tudományos Intézet

Citations 8

Per-pass analysis of acute ischemic stroke clots: impact of stroke etiology on extracted clot area and histological composition

Journal of NeuroInterventional Surgery | December 9, 2020 | Volume: 13 | Issue: 12 | Pages: 1111-1116

10.1136/neurintsurg-2020-016966 | PMID 33298510

Background Initial studies investigating correlations between stroke etiology and clot composition are conflicting and do not account for clot size as determined by area. Radiological studies have shown that cardioembolic strokes are associated with shorter clot lengths and lower clot burden than non-cardioembolic clots. Objective To report the relationship between stroke etiology, extracted clot area, and histological composition at each procedural pass. Methods As part of the multi-institutional RESTORE Registry, the Martius Scarlett Blue stained histological composition and extracted clot area of 612 per-pass clots retrieved from 441 patients during mechanical thrombectomy procedures were quantified. Correlations with clinical and procedural details were investigated. Results Clot composition varied significantly with procedural passes; clots retrieved in earlier passes had higher red blood cell content (H4=11.644, p=0.020) and larger extracted clot area (H4=10.730, p=0.030). Later passes were associated with significantly higher fibrin (H4=12.935, p=0.012) and platelets/other (H4=15.977, p=0.003) content and smaller extracted clot area. Large artery atherosclerotic (LAA) clots were significantly larger in the extracted clot area and more red blood cell-rich than other etiologies in passes 1–3. Cardioembolic and cryptogenic clots had similar histological composition and extracted clot area across all procedural passes. Conclusion LAA clots are larger and associated with a large red blood cell-rich extracted clot area, suggesting soft thrombus material. Cardioembolic clots are smaller in the extracted clot area, consistent in composition and area across passes, and have higher fibrin and platelets/other content than LAA clots, making them stiffer clots. The per-pass histological composition and extracted clot area of cryptogenic clots are similar to those of cardioembolic clots, suggesting similar formation mechanisms.
Histological stroke clot analysis after thrombectomy: Technical aspects and recommendations

International Journal of Stroke | November 4, 2019 | Volume: 15 | Issue: 5 | Pages: 467-476

10.1177/1747493019884527 | PMID 31679478

The recent advent of endovascular procedures has created the unique opportunity to collect and analyze thrombi removed from cerebral arteries, instigating a novel subfield in stroke research. Insights into thrombus characteristics and composition could play an important role in ongoing efforts to improve acute ischemic stroke therapy. An increasing number of centers are collecting stroke thrombi. This paper aims at providing guiding information on thrombus handling, procedures, and analysis in order to facilitate and standardize this emerging research field.
Prospective study on embolization of intracranial aneurysms with the pipeline device: the PREMIER study 1 year results

Journal of NeuroInterventional Surgery | July 15, 2019 | Volume: 12 | Issue: 1 | Pages: 62-66

10.1136/neurintsurg-2019-015091 | PMID 31308197

Background Preliminary clinical studies on the safety and efficacy of the pipeline embolization device (PED) for the treatment of small/medium aneurysms have demonstrated high occlusion rates with low complications. Objective To evaluate the safety and effectiveness of the PED for treatment of wide necked small and medium intracranial aneurysms. Methods PREMIER is a prospective, multicenter, single arm trial. Patients were treated with the PED for unruptured wide necked aneurysms, measuring ≤12 mm along the internal carotid artery or vertebral artery, between July 2014 and November 2015. At 1 year post-procedure, the primary effectiveness endpoint was complete occlusion (Raymond grade 1) without major parent vessel stenosis (≤50%) or retreatment, and the primary safety endpoint was major stroke in the territory supplied by the treated artery or neurologic death. Results A total of 141 patients were treated with PEDs (mean age 54.6±11.3 years, 87.9% (124/141) women). Mean aneurysm size was 5.0±1.92 mm, and 84.4% (119/141) measured <7 mm. PED placement was successful in 99.3% (140/141) of patients. Mean number of PEDs implanted per patient was 1.1±0.26; a single PED was used in 92.9% (131/141) of patients. At 1 year, 97.9% (138/141) of patients underwent follow-up angiography with 76.8% (106/138) of patients having met the study’s primary effectiveness endpoint. The combined major morbidity and mortality rate was 2.1% (3/140). Conclusions Treatment of wide necked small/medium aneurysms with the PED results in high rates of complete occlusion without significant parent vessel stenosis and low rates of permanent neurologic complications. Trial registration NCT02186561 .
Analyses of thrombi in acute ischemic stroke: A consensus statement on current knowledge and future directions

International Journal of Stroke | May 23, 2017 | Volume: 12 | Issue: 6 | Pages: 606-614

10.1177/1747493017709671 | PMID 28534706

Limited data exist on clot composition and detailed characteristics of arterial thrombi associated with large vessel occlusion in acute ischemic stroke. Advances in endovascular thrombectomy and related imaging modalities have created a unique opportunity to analyze thrombi removed from cerebral arteries. Insights into thrombus composition, etiology, physical properties and neurovascular interactions may lead to future advancements in acute ischemic stroke treatment and improved clinical outcomes. Advances in imaging techniques may enhance clot characterization and inform therapeutic decision-making prior to treatment and reveal stroke etiology to guide secondary prevention. Current imaging techniques can provide some information about thrombi, but there remains much to evaluate about relationships that may exist among thrombus composition, occlusion characteristics and treatment outcomes. Improved pathophysiological characterization of clot types, their properties and how these properties change over time, together with clinical correlates from ongoing studies, may facilitate revascularization with thrombolysis and thrombectomy. Interdisciplinary approaches covering clinical, engineering and scientific aspects of thrombus research will be key to advancing the understanding of thrombi and improving acute ischemic stroke therapy. This consensus statement integrates recent research on clots and thrombi retrieved from cerebral arteries and provides a rationale for further analyses, including current opportunities and limitations.
Long-Term Clinical and Angiographic Outcomes Following Pipeline Embolization Device Treatment of Complex Internal Carotid Artery Aneurysms: Five-Year Results of the Pipeline for Uncoilable or Failed Aneurysms Trial

Neurosurgery | February 5, 2017 | Volume: 80 | Issue: 1 | Pages: 40-48

10.1093/neuros/nyw014 | PMID 28362885

Abstract BACKGROUND: Early and mid-term safety and efficacy of aneurysm treatment with the Pipeline Embolization Device (PED) has been well demonstrated in prior studies. OBJECTIVE: To present 5-yr follow-up for patients treated in the Pipeline for Uncoilable or Failed Aneurysms clinical trial. METHODS: In our prospective, multicenter trial, 109 complex internal carotid artery (ICA) aneurysms in 107 subjects were treated with the PED. Patients were followed per a standardized protocol at 180 d and 1, 3, and 5 yr. Aneurysm occlusion, in-stent stenosis, modified Rankin Scale scores, and complications were recorded. RESULTS: The primary endpoint of complete aneurysm occlusion at 180 d (73.6%) was previously reported. Aneurysm occlusion for those patients with angiographic follow-up progressively increased over time to 86.8% (79/91), 93.4% (71/76), and 95.2% (60/63) at 1, 3, and 5 yr, respectively. Six aneurysms (5.7%) were retreated. New serious device-related events at 1, 3, and 5 yr were noted in 1% (1/96), 3.5% (3/85), and 0% (0/81) of subjects. There were 4 (3.7%) reported deaths in our trial. Seventy-eight (96.3%) of 81 patients with 5-yr clinical follow-up had modified Rankin Scale scores ≤2. No delayed neurological deaths or hemorrhagic or ischemic cerebrovascular events were reported beyond 6 mo. No recanalization of a previously occluded aneurysm was observed. CONCLUSION: Our 5-yr findings demonstrate that PED is a safe and effective treatment for large and giant wide-necked aneurysms of the intracranial ICA, with high rates of complete occlusion and low rates of delayed adverse events.
Pipeline for uncoilable or failed aneurysms: 3-year follow-up results

Journal of Neurosurgery | October 14, 2016 | Volume: 127 | Issue: 1 | Pages: 81-88

10.3171/2015.6.jns15311 | PMID 27739944

OBJECTIVEThe long-term effectiveness of endovascular treatment of large and giant wide-neck aneurysms using traditional endovascular techniques has been disappointing, with high recanalization and re-treatment rates. Flow diversion with the Pipeline Embolization Device (PED) has been recently used as a stand-alone therapy for complex aneurysms, showing significant improvement in effectiveness while demonstrating a similar safety profile to stent-supported coil treatment. However, relatively little is known about its long-term safety and effectiveness. Here the authors report on the 3-year safety and effectiveness of flow diversion with the PED in a prospective cohort of patients with large and giant internal carotid artery aneurysms enrolled in the Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial.METHODSThe PUFS trial is a prospective study of 107 patients with 109 aneurysms treated with the PED. Primary effectiveness and safety end points were demonstrated based on independently monitored 180-day clinical and angiographic data. Patients were enrolled in a long-term follow-up protocol including 1-, 3-, and 5-year clinical and imaging follow-up. In this paper, the authors report the midstudy (3-year) effectiveness and safety data.RESULTSAt 3 years posttreatment, 74 subjects with 76 aneurysms underwent catheter angiography as required per protocol. Overall, complete angiographic aneurysm occlusion was observed in 71 of these 76 aneurysms (93.4% cure rate). Five aneurysms were re-treated, using either coils or additional PEDs, for failure to occlude, and 3 of these 5 were cured by the 3-year follow-up. Angiographic cure with one or two treatments of Pipeline embolization alone was therefore achieved in 92.1%. No recanalization of a previously completely occluded aneurysm was noted on the 3-year angiograms. There were 3 (2.6%) delayed device- or aneurysm-related serious adverse events, none of which led to permanent neurological sequelae. No major or minor late-onset hemorrhagic or ischemic cerebrovascular events or neurological deaths were observed in the 6-month through 3-year posttreatment period. Among 103 surviving patients, 85 underwent functional outcome assessment in which modified Rankin Scale scores of 0–1 were demonstrated in 80 subjects.CONCLUSIONSPipeline embolization is safe and effective in the treatment of complex large and giant aneurysms of the intracranial internal carotid artery. Unlike more traditional endovascular treatments, flow diversion results in progressive vascular remodeling that leads to complete aneurysm obliteration over longer-term follow-up without delayed aneurysm recanalization and/or growth.Clinical trial registration no.: NCT00777088 (clinicaltrials.gov)
Neuroophthalmological outcomes associated with use of the Pipeline Embolization Device: analysis of the PUFS trial results

Journal of Neurosurgery | July 10, 2015 | Volume: 123 | Issue: 4 | Pages: 897-905

10.3171/2014.12.jns141777 | PMID 26162031

OBJECT Neuroophthalmological morbidity is commonly associated with large and giant cavernous and supraclinoid internal carotid artery (ICA) aneurysms. The authors sought to evaluate the neuroophthalmological outcomes after treatment of these aneurysms with the Pipeline Embolization Device (PED). METHODS The Pipeline for Uncoilable or Failed Aneurysms (PUFS) trial was an international, multicenter prospective trial evaluating the safety and efficacy of the PED. All patients underwent complete neuroophthalmological examinations both before the PED procedure and at a 6-month follow-up. All examinations were performed for the purpose of this study and according to study criteria. RESULTS In total, 108 patients were treated in the PUFS trial, 98 of whom had complete neuroophthalmological follow-up. Of the patients with complete follow-up, 39 (40%) presented with a neuroophthalmological baseline deficit that was presumed to be attributable to the aneurysm, and patients with these baseline deficits had significantly larger aneurysms. In 25 of these patients (64%), the baseline deficit showed at least some improvement 6 months after PED treatment, whereas in 1 patient (2.6%), the deficits only worsened. In 5 patients (5%), new deficits had developed at the 6-month follow-up, while in another 6 patients (6%), deficits that were not originally assumed to be related to the aneurysm had improved by that time. A history of diabetes was associated with failure of the baseline deficits to improve after the treatment. The aneurysm maximum diameter was significantly larger in patients with a new deficit or a worse baseline deficit at 6 months postprocedure. CONCLUSIONS Patients treated with the PED for large and giant ICA aneurysms had excellent neuroophthalmological outcomes 6 months after the procedure, with deficits improving in most of the patients, very few deficits worsening, and few new deficits developing.
O-009 Safety of flow diversion: Results from a multicentre registry

Journal of NeuroInterventional Surgery | July 15, 2013 | Volume: 5 | Issue: Suppl 2 | Pages: A6.1-A6

10.1136/neurintsurg-2013-010870.9

Purpose To determine the rates of neurologic adverse events following Pipeline Embolic Device (PED) placement for intracranial aneurysm treatment. Methods A retrospective review of medical records was performed at 19 centres to identify consecutive intracranial aneurysms treated with the PED following regulatory approval for marketing the device in the given country. All patients in whom at least one PED was placed and in whom follow-up was available prior to IRB or ethics panel approval were enrolled. Three anatomic/size subgroups were defined, including 1) pre-PComm, internal carotid artery aneurysms 10mm or greater (“large ICA”), 2) ICA aneurysms >10mm and/or at/distal to the PComm region (“other anterior circulation”), and 3) posterior circulation aneurysms. “Primary safety events” included stroke, haemorrhage, parent artery stenosis, permanent cranial neuropathy, and spontaneous rupture of the target aneurysm. Severe safety events were defined as any event causing significant impairment of functioning causing the inability of the subject to carry out usual activities. Statistical analysis was performed using standard summary statistics; p-values comparing subgroups were computed using Pearson's chi-square test for discrete variables and analysis of variance for continuous variables. Results To date, 580 aneurysms, including 183 large ICA, 344 other anterior circulation, and 53 posterior circulation aneurysms have been treated and followed for a mean duration of 7.8 months (SD 7.3, range 0.1 - 40.8). 437 (76%) of 580 aneurysms were saccular and 80 (14%) were fusiform; 32 (5.5%) were classified as giant (<25mm diameter). 549 (93%) were unruptured. 241 (42%) were treated with multiple PEDs. Primary safety events were noted in 62 (12%) cases. Severe neurological events occurred in 35 (6.8%) cases, and occurred more frequently in posterior circulation aneurysms (7 (13%)) than in either large ICA or other anterior circulation aneurysms (15 (8.8%) and (13 (4.5%), respectively, p=.035). Major stroke occurred in 20 (3.9%) of 515 subjects (4.1%, 3.1%, and 7.5% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.31). Ipsilateral intracranial haemorrhage occurred in 12 (2.3%) subjects (3.5%, 1.7%, and 1.9% in large ICA, other anterior circulation, and posterior circulation aneurysms, respectively, p=.47). Spontaneous aneurysm rupture occurred in 3 (0.6%) aneurysms, all of which were giant, resulting in a 9% incidence of rupture in giant aneurysms. Mortality rate was 4.3% and was significantly higher for posterior circulation aneurysms (11.3%) as compared to anterior circulation aneurysms (3.5%, p=.019). Conclusions Preliminary data indicates that in approximately 7% of aneurysms treated with PED, substantial neurologic complications occurred, with rates of both severe neurologic events and mortality occurring significantly higher in the posterior as compared to the anterior circulation. Both ipsilateral haemorrhage and spontaneous aneurysm rupture were rare, with the latter event limited to giant aneurysms. Disclosures D. Kallmes: 1; C; MicroVention, Sequent, Benvenue, eV3. 2; C; General Electric, Codman, eV3. E. Boccardi: None. A. Bonafe: None. S. Cekirge: None. D. Fiorella: 2; C; Pipeline proctor, consultant, (<10K, EV3). R. Hanel: None. P. Jabbour: None. E. Levy: None. D. Lopes: 6; C; Receives compensation for training & proctoring for Pipeline devices. P. Lylyk: None. C. McDougall: None. A. Siddiqui: None. I. Szikora: None. H. Woo: None.