Citations

Mayo Clinic

Clear

11 citation(s) found for "Itoi, Eiji".

Stabilising function of the biceps in stable and unstable shoulders
Itoi, Eiji, Kuechle, DK, Newman, Morrey, BF, An, K-N, An, K-N.

The Journal of Bone and Joint Surgery. British volume | February 21, 2018 | Volume: 75-B | Issue: 4 | Pages: 546-550

10.1302/0301-620x.75b4.8331107 | PMID 8331107 Get It

We studied the contributions of the long and short heads of the biceps (LHB, SHB) to anterior stability in 13 cadaver shoulders. The LHB and SHB were replaced by spring devices and translation tests at 90 degrees abduction of the arm were performed by applying a 1.5 kg anterior force. The position of the humeral head was monitored by an electromagnetic tracking device with or without an anterior translational force; with 0 kg, 1.5 kg or 3 kg loads applied on either LHB or SHB tendons in 60 degrees, 90 degrees or 120 degrees of external rotation; and with the capsule intact, vented, or damaged by a Bankart lesion. The anterior displacement of the humeral head under 1.5 kg force was significantly decreased by both the LHB and SHB loading in all capsular conditions when the arm was in 60 degrees or 90 degrees of external rotation. At 120 degrees of external rotation, anterior displacement was significantly decreased by LHB and SHB loading only when there was a Bankart lesion. We conclude that LHB and SHB have similar functions as anterior stabilizers of the glenohumeral joint with the arm in abduction and external rotation, and that their role increases as shoulder stability decreases. Both heads of the biceps have been shown to have a stabilising function in resisting anterior head displacement, and consideration should therefore be given to strengthening the biceps during rehabilitation programmes for chronic anterior instability of the shoulder.
Dynamic Stabilizing Function of the Deltoid Muscle in Shoulders with Anterior Instability
Kido, Tadato , Itoi, Eiji, Lee, Seok-Beom, Neale, Patricia G., An, Kai‐Nan

The American Journal of Sports Medicine | July 19, 2017 | Volume: 31 | Issue: 3 | Pages: 399-403

10.1177/03635465030310031201 | PMID 12750133 Get It

Background The stabilizing role of the deltoid muscle has not been extensively studied. Purpose To study the contribution of the deltoid muscle to anterior stability of the shoulder. Study Design Controlled laboratory study. Methods We used nine fresh cadaveric shoulders with the arm at 90° of abduction and 90° of external rotation. The position of the humeral head was monitored by an electromagnetic tracking device with 0 and 1.5 kg of anterior translation force; with 0, 1, 3, and 5 kg of force applied to each of the anterior, middle, and posterior portions of the deltoid muscle; and with the capsule intact, vented, and with a simulated Bankart lesion. Results With the capsule intact, anterior displacement was significantly reduced by application of load to the middle deltoid muscle. After the capsule was vented, load application to the anterior, middle, or posterior deltoid muscle significantly reduced anterior displacement. With a simulated Bankart lesion, effects of muscle loading were most apparent: anterior displacement was significantly reduced with loading of each muscle portion. Conclusion The deltoid muscle is an anterior stabilizer of the glenohumeral joint with the arm in abduction and external rotation. Clinical Relevance The stabilizing function of the deltoid muscle takes on more importance as the shoulder becomes unstable.
Quantitative Assessment of Classic Anteroinferior Bony Bankart Lesions by Radiography and Computed Tomography
Lee, Seok-Beom, Amrami, Kimberly K. , Wenger, Doris E. , An, Kai‐Nan , Itoi, Eiji

The American Journal of Sports Medicine | July 18, 2017 | Volume: 31 | Issue: 1 | Pages: 112-118

10.1177/03635465030310010301 | PMID 12531767 Get It

Background An anteroinferior osseous defect of the glenoid rim is sometimes encountered in patients with recurrent anterior dislocations of the shoulder. A defect of more than 21% of the glenoid length is reported to cause instability after Bankart repair. Hypothesis We can estimate the critical size of glenoid defects by using radiography or computed tomography. Study Design A controlled laboratory study. Methods Osseous defects of 0%, 9%, 21%, 34%, and 46% of the glenoid length were created stepwise in 12 cadaveric scapulae, and plain radiographs simulating the axillary and West Point views and computed tomographic images were obtained. The maximum width of the remnant glenoid was measured under each condition and expressed as a percentage of the width of the intact glenoid. Results A 21% defect appeared to be 18.6% of the intact glenoid on the West Point view. With computed tomography, a 21% defect resulted in loss of 50% of the width on a single slice across the lower one-fourth of the glenoid. Conclusions We can estimate the size of a glenoid defect by using the West Point radiographic view or computed tomogram. Clinical Relevance These images gave decisive information as to whether an osseous glenoid defect required bone grafting to achieve stability after Bankart repair.
Comparison of Passive Stiffness Changes in the Supraspinatus Muscle After Double‐Row and Knotless Transosseous‐Equivalent Rotator Cuff Repair Techniques: A Cadaveric Study
Giambini, Hugo , Hooke, Alexander W. , Zhao, Chunfeng , Sperling, John W. , Steinmann, Scott P. , Yamamoto, Nobuyuki , Itoi, Eiji, An, Kai‐Nan , Hatta, Taku, Hatta, Taku

Arthroscopy | May 4, 2016 | Volume: 32 | Issue: 10 | Pages: 1973-1981

10.1016/j.arthro.2016.02.024 | PMID 27157656 Get It

Purpose To investigate the alteration of passive stiffness in the supraspinatus muscle after double‐row (DR) and knotless transosseous‐equivalent (KL‐TOE) repair techniques, using shear wave elastography (SWE) in cadavers with rotator cuff tears. We also aimed to compare altered muscular stiffness after these repairs to that obtained from shoulders with intact rotator cuff tendon. Methods Twelve fresh‐frozen cadaveric shoulders with rotator cuff tear (tear size: small [6], medium‐large [6]) were used. Passive stiffness of 4 anatomic regions in the supraspinatus muscle was measured based on an established SWE method. Each specimen underwent DR and KL‐TOE footprint repairs at 30° glenohumeral abduction. SWE values, obtained at 0°, 10°, 20°, 30°, 60°, and 90° abduction, were assessed in 3 different conditions: preoperative (torn) and postoperative conditions with the 2 techniques. The increased ratio of SWE values after repair was compared among the 4 regions to assess stiffness distribution. In addition, SWE values were obtained on 12 shoulders with intact rotator cuff tendons as control. Results In shoulders with medium‐large‐sized tears, supraspinatus muscles showed an increased passive stiffness after rotator cuff repairs, and this was significantly observed at adducted positions. KL‐TOE repair showed uniform stiffness changes among the 4 regions of the supraspinatus muscle (mean, 189% to 218% increase after repair), whereas DR repair caused a significantly heterogeneous stiffness distribution within the muscle (mean, 187% to 319% after repair, P = .002). Although a repair‐induced increase in muscle stiffness was observed also in small‐sized tears, there were no significant differences in repaired stiffness changes between DR and KL‐TOE (mean, 127% to 138% and 127% to 130% after repairs, respectively). Shoulders with intact rotator cuff tendon showed uniform SWE values among the 4 regions of the supraspinatus muscle (mean, 38.2 to 43.0 kPa). Conclusions Passive stiffness of the supraspinatus muscle increases after rotator cuff repairs for medium‐large‐sized tears. KL‐TOE technique for the medium‐large‐sized tear provided a more uniform stiffness distribution across the repaired supraspinatus muscles compared with the DR technique. Clinical Relevance Based on this insight, investigating rotator cuff muscle stiffness changes, further studies using SWE may determine the optimal repair technique for various sizes of rotator cuff tears.
Feasibility assessment of shear wave elastography to rotator cuff muscle
Itoigawa, Yoshiaki , Sperling, John W. , Steinmann, Scott P. , Chen, Qingshan , Song, Pengfei , Chen, Shigao , An, Kai‐Nan, Itoi, Eiji , Hatta, Taku , An, Kai‐Nan , Song, Pengfei

Clinical Anatomy | December 30, 2014 | Volume: 28 | Issue: 2 | Pages: 213-218

10.1002/ca.22498 | PMID 25557287 Get It

Pre‐surgical measurement of supraspinatus muscle extensibility is important for rotator cuff repair. The purpose of the present study was to explore the potential feasibility of a shear wave ultrasound elastography (SWE)‐based method, combined with B‐mode ultrasound, to measure the in vivo stiffness of the supraspinatus muscle non‐invasively and thus obtain key information about supraspinatus muscle extensibility. Our investigation comprised two steps. First, we determined the orientation of the supraspinatus muscle fibers in cadaveric shoulders without rotator cuff tear in order to optimize the ultrasound probe positions for SWE imaging. Second, we investigated the feasibility of quantifying the stiffness of the normal supraspinatus muscle by SWE in vivo. The supraspinatus muscle was divided into four anatomical regions: anterior superficial (AS), posterior superficial (PS), anterior deep (AD), and posterior deep (PD). Each region was examined by SWE. The SWE stiffnesses of AD, AS, PD, and PS were 40.0 ± 12.4, 34.0 ± 9.9, 32.7 ± 12.7, 39.1 ± 15.7 kPa, respectively. SWE combined with B‐Mode ultrasound imaging could be a feasible method for quantifying the local stiffness of the rotator cuff muscles. Clin. Anat. 28:213–218, 2015. © 2014 Wiley Periodicals, Inc.
The Effect of the Remplissage Procedure on Shoulder Range of Motion: A Cadaveric Study
Omi, Rei, Hooke, Alexander W. , Zhao, Kristin D. , Matsuhashi, Tomoya , Yamamoto, Nobuyuki , Sperling, John W. , Steinmann, Scott P. , An, Kai‐Nan , Gotō, Akira , Gotō, Akira , Itoi, Eiji , Trentadue, Taylor P

Arthroscopy | January 3, 2014 | Volume: 30 | Issue: 2 | Pages: 178-187

10.1016/j.arthro.2013.11.003 | PMID 24388452 Get It

Purpose The purpose of this in vitro biomechanical study was to assess the effects of the remplissage procedure for small‐ and large‐sized Hill‐Sachs lesions (HSLs) on shoulder range of motion (ROM) with a special interest in the apprehension position. Methods HSLs of 50% and 100% of the glenoid width were simulated in 7 cadaveric shoulders as small and large lesions, respectively, and the postoperative condition was reproduced by placing suture anchors on the articular surface and tying down the infraspinatus at the medial edge of the would‐be lesion site. ROMs were measured in abduction, internal rotation, and external rotation with the humerus in the adducted and abducted position. In addition, the ROM was measured in the anterior apprehension position, in which 2 torques of external rotation and extension were applied simultaneously, and external rotation and horizontal extension ROMs were measured with the humerus in different abduction angles (20°, 40°, and 60°). Results For standard ROMs, the procedure for the 50% HSL maintained complete ROMs, whereas the procedure for the 100% HSL significantly decreased external rotation ROM with the humerus in both the adducted and abducted positions, as well as abduction ROM. In the apprehension position, remplissage for the 50% HSL decreased extension ROM with the humerus abducted to 40° and 60°. Remplissage for the 100% HSL significantly decreased both external and extension ROMs regardless of the humeral abduction angle. Conclusions In the cadaveric model with an intact humeral head and the simulated postoperative condition, the remplissage procedure for a large HSL caused significant restrictions in ROM of abduction in the scapular plane and external rotation with the humerus in both adduction and abduction. It also caused significant restrictions in both external rotation and extension ROMs in the apprehension position. Clinical Relevance The indication for the remplissage procedure for the larger HSL should be considered carefully, especially for the competitive throwing athlete who needs exceptional external rotation ROM for optimal overhead throwing performance.
Effect of an Anterior Glenoid Defect on Anterior Shoulder Stability
Yamamoto, Nobuyuki , Abe, Hidekazu, Kikuchi, Kazuma , Seki, Nobutoshi , Minagawa, Hiroshi , Tuoheti, Yilihamu, Itoi, Eiji

The American Journal of Sports Medicine | March 4, 2009 | Volume: 37 | Issue: 5 | Pages: 949-954

10.1177/0363546508330139 | PMID 19261900 Get It

Background There have been few biomechanical studies to clarify which size of a glenoid defect is critical. However, those studies have assumed that the defect occurred anteroinferiorly. Recent studies have reported that the defect is located anteriorly rather than anteroinferiorly. Therefore, the effect of the anterior, not anteroinferior, glenoid defect on shoulder stability needs to be investigated. Hypothesis The anterior glenoid defect would have a similar effect on anterior shoulder stability as that of the anteroinferior glenoid defect. Study Design Controlled laboratory study. Methods Eight fresh-frozen cadaveric shoulders were used (mean age, 74 years). The specimen was attached to a shoulder-testing device with the arm in abduction and external rotation. An osseous defect was created stepwise with a 2-mm increment of the defect width. The stability ratio was used to evaluate joint stability. With a 50-N axial force, the translational force applied to the humeral head was measured by a force transducer. Results The stability ratio without a defect (32% ± 6%) significantly decreased after creating a 6-mm defect (17% ± 5%; P = .0001), which was equivalent to 20% of the glenoid length. Conclusion An osseous defect at 3 o'clock with a width that was equal to or greater than 20% of the glenoid length significantly decreased anterior stability. Clinical Relevance The results suggest that reconstruction of the glenoid concavity might be necessary in shoulders with an anterior glenoid defect of at least 20% of the glenoid length.
MOMENT ARMS OF THE ARM MUSCLES AT THE GLENOHUMERAL JOINT USING THE TENDON EXCURSION METHOD
Itoi, Eiji, Lee, Seok-Beom, Berglund, Lawrence J., Schultz, Fredrick M., Neale, Patricia G., An, Kai‐Nan

Journal of Musculoskeletal Research | September 15, 2008 | Volume: 11 | Issue: 02 | Pages: 45-53

10.1142/s0218957708001973 Get It

Muscle moment arm defines the function of the muscle. To date, moment arms of the arm muscles at the glenohumeral joint using the tendon excursion method have not been reported. As the functions of these muscles at the shoulder joint are controversial, this study was undertaken to determine the moment arms of the long and short heads of the biceps (LHB, SHB), the coracobrachialis, and the long head of the triceps muscles. The moment arms were determined in 10 cadaveric shoulders by measuring the tendon excursion when the arm was rotated by 1 radian (57.3°) in 22 different motions. The LHB was a flexor, horizontal flexor, and abductor. The SHB and coracobrachialis were flexors, horizontal flexors, and adductors. The long head of the triceps was an extensor and adductor. Arm rotation significantly affected the function of the LHB only: it was an internal rotator in flexion and an external rotator in abduction. This study clarifies the individual function of the arm muscles at the glenohumeral joint.
Contribution of Axial Arm Rotation to Humeral Head Translation
Motzkin, Neil E., Morrey, B.F. , An, Kai‐Nan , Itoi, Eiji

The American Journal of Sports Medicine | June 21, 2007 | Volume: 22 | Issue: 4 | Pages: 499-503

10.1177/036354659402200411 | PMID 7943515 Get It

The contribution of axial arm rotation to translation of the humeral head with the arm in the hanging position was examined using nine fresh-frozen cadaveric shoulders. Three standard clinical tests were simulated: anterior and posterior translation and sulcus tests. In both the anterior translation and sulcus tests, anterior and infe rior displacements were significantly restricted in inter nal rotation but not in neutral and external rotation. In the posterior translation test, no significant differences in displacement could be observed in internal, neutral, or external rotation. Since anterior and inferior translations of the humeral head were significantly affected by the rotation of the arm, we recommend that the anterior translation and sulcus tests be performed in various rotations.
Intraarticular pressure of the shoulder
Motzkin, Neil E., Browne, A.O., Hoffmeyer, Pierre , Morrey, B.F. , An, Kai‐Nan , Itoi, Eiji

Arthroscopy | July 22, 2006 | Volume: 9 | Issue: 4 | Pages: 406-413

10.1016/s0749-8063(05)80314-7 | PMID 8216571 Get It

Summary Nine fresh frozen cadaveric shoulders were used to examine the changes in intraarticular pressure (IAP) of the shoulder joint and the position of the humeral head under various loads to determine the relationship between these parameters. All the soft tissues superficial to the rotator cuff were removed. The position of the humerus relative to the scapula was monitored using an electromagnetic tracking system before and after venting the capsule with 0, 0.5, and 1.0 kg of load applied to the humerus inferiorly in addition to the weight of the arm. Simultaneously, the IAP was monitored using a pressure transducer before venting the capsule. Venting had a significant effect on the position of the humeral head: the positions of the head after venting were significantly lowered in all loading conditions. The average IAP was −76 cm H 2 O without load, and the value decreased in a linear fashion with increased load; the correlations were significant in four of six shoulders without dislocation. The correlations were less significant between the pressure and the position, and there were no significant correlations between the load and the position. IAP, which is determined primarily by the load applied, is important to stabilize the shoulder inferiorly. Because IAP is intimately related to the external load and the response is specific to individuals, examination of IAP response to external load may be helpful in characterizing various instabilities of the shoulder.