Citations

Mayo Clinic

Showing 10 of 108551 citations.

Fungal, Viral, and Parasitic Pneumonias Associated with Human Immunodeficiency Virus
Skalski, Joseph H. , Limper, Andrew H.

Seminars in Respiratory and Critical Care Medicine | March 14, 2016 | Volume: 37 | Issue: 02 | Pages: 257-266

10.1055/s-0036-1578802 | PMID 26974302 Get It

On My Honor
Shannon, Robert P. , Estupinan, Danny , Villanueva, Armando

Journal of Palliative Medicine | March 14, 2016 | Volume: 19 | Issue: 4 | Pages: 464-464

10.1089/jpm.2015.0410 | PMID 26974690 Get It

Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Zhao, Kristin D. , Ben‐Abraham, Ephraim I., Magnuson, Dixon J., Camp, Jon J. , Berglund, Lawrence J., An, Kai‐Nan , Brønfort, Gert , Gay, Ralph E. , Trentadue, Taylor P

Journal of Biomechanical Engineering | March 14, 2016 | Volume: 138 | Issue: 5 | Pages: No page available

10.1115/1.4032995 | PMID 26974192 Get It

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
Associated Factors and Prognostic Implications of Stimulus-Induced Rhythmic, Periodic, or Ictal Discharges
Braksick, Sherri A. , Burkholder, David B. , Tsetsou, Spyridoula , Martineau, Laurence, Mandrekar, Jay , Rossetti, Andrea O. , Savard, Martin , Britton, Jeffrey W. , Rabinstein, Alejandro A. , Burkholder, David B

JAMA Neurology | March 14, 2016 | Volume: 73 | Issue: 5 | Pages: 585

10.1001/jamaneurol.2016.0006 | PMID 26975002 Get It

Anatomical Variation of Human Collector Channel Orifices
Bentley, Michael D., Hann, Cheryl R., Fautsch, Michael P.

Investigative Opthalmology & Visual Science | March 14, 2016 | Volume: 57 | Issue: 3 | Pages: 1153

10.1167/iovs.15-17753 | PMID 26975026 Get It

History of chickenpox in glioma risk: a report from the glioma international case–control study (GICC)
Amirian, E. Susan , Scheurer, Michael E. , Zhou, Renke, Wrensch, Margaret , Armstrong, Georgina , Olson, Sara H. , Claus, Elizabeth B. , Barnholtz‐Sloan, Jill S. , Schildkraut, Joellen M. , Ali‐Osman, Francis, Sadetzki, Siegal , Jenkins, Robert B. , Bernstein, Jonine L. , Merrell, Ryan , Davis, Faith G., Lai, Rose , Shete, Sanjay , Melin, Beatrice , Bondy, Melissa L. , Lachance, Daniel, Armstrong, Georgina , Lachance, Daniel Honore , Lau, Ching C. , Il’yasova, Dora , Amos, Christopher I. , Barnholtz-Sloan, Jill S

Cancer Medicine | March 14, 2016 | Volume: 5 | Issue: 6 | Pages: 1352-1358

10.1002/cam4.682 | PMID 26972449 Get It

AbstractVaricella zoster virus (VZV) is a neurotropic α‐herpesvirus that causes chickenpox and establishes life‐long latency in the cranial nerve and dorsal root ganglia of the host. To date, VZV is the only virus consistently reported to have an inverse association with glioma. The Glioma International Case‐Control Study (GICC) is a large, multisite consortium with data on 4533 cases and 4171 controls collected across five countries. Here, we utilized the GICC data to confirm the previously reported associations between history of chickenpox and glioma risk in one of the largest studies to date on this topic. Using two‐stage random‐effects restricted maximum likelihood modeling, we found that a positive history of chickenpox was associated with a 21% lower glioma risk, adjusting for age and sex (95% confidence intervals (CI): 0.65–0.96). Furthermore, the protective effect of chickenpox was stronger for high‐grade gliomas. Our study provides additional evidence that the observed protective effect of chickenpox against glioma is unlikely to be coincidental. Future studies, including meta‐analyses of the literature and investigations of the potential biological mechanism, are warranted.
The ototronix MAXUM middle ear implant for severe high-frequency sensorineural hearing loss: Preliminary results
Hunter, Jacob B. , Carlson, Matthew L. , Glasscock, Michael E., Hunter, Jacob B

The Laryngoscope | March 14, 2016 | Volume: 126 | Issue: 9 | Pages: 2124-2127

10.1002/lary.25872 | PMID 26972428 Get It

Long‐term outcome of patients with POEMS syndrome: An update of the Mayo Clinic experience
Kourelis, Taxiarchis , Kumar, Shaji , Lacy, Martha Q. , Dingli, David , Go, Ronald S. , Kapoor, Prashant , Lust, John A., Hayman, Suzanne R. , Hwa, Yi L. , Zeldenrust, Steven R., Russell, Stephen J. , Lin, Yi , Kyle, Robert A. , Dispenzieri, Angela , Kourelis, Taxiarchis V, Buadi, Francis K. , Go, Ronald S , Hwa, Yi, Gertz, Morie A. , Rajkumar, S. Vincent , Leung, Nelson , Gonsalves, Wilson I. , Dispenzieri, Angela , Russell, Stephen J , Dingli, David , Lin, Yi

American Journal of Hematology | March 14, 2016 | Volume: 91 | Issue: 6 | Pages: 585-589

10.1002/ajh.24356 | PMID 26972803 Get It

Over the past decade, a number of changes have occurred in the diagnostic evaluation, management, and long‐term follow‐up of patients with POEMS syndrome at our institution. This study included 291 patients with POEMS syndrome diagnosed at the Mayo Clinic between 1974 and 2014. Patients diagnosed after 2003 had more features of the syndrome identified at diagnosis and were more likely to receive an autologous transplant (49% versus 8%, P < 0.0001) and to have achieved a hematologic complete response (CR) to treatment (41% vs 25%, P < 0.0001). With 2273 person‐years of follow‐up, 10‐year overall survival (OS) was 62% (95% C.I., 56%, 67%). On multivariate analysis, the three factors associated with superior OS were younger age (RR 0.98 [0.96–1.00]), albumin greater‐than 3.2 g/dL (RR 0.5 [0.32–0.89]) and attainment of complete hematologic response (RR 0.4 [0.2, 0.9]). This study confirms the very good long‐term outcomes of patients with POEMS syndrome and identifies two new prognostic risk factors: albumin at diagnosis and attainment of complete hematologic response. Am. J. Hematol. 91:585–589, 2016. © 2016 Wiley Periodicals, Inc.
Clinimetric testing of the comprehensive cervical dystonia rating scale
Comella, Cynthia , Waliczek, Tracy, Rosen, Ami, Galpern, Wendy R., Adler, Charles, Barbano, Richard L. , Reich, Stephen G. , Rodriguez, Ramon L. , Severt, William, Zurowski, Mateusz , Fox, Susan H. , Stebbins, Glenn T. , Adler, Charles A, Perlmutter, Joel S. , Jinnah, H. A. , Factor, Stewart Alan , Goetz, Christopher G. , Jankovic, Joseph J.

Movement Disorders | March 14, 2016 | Volume: 31 | Issue: 4 | Pages: 563-569

10.1002/mds.26534 | PMID 26971359 Get It

ABSTRACT Introduction The aim of this study was to test the clinimetric properties of the Comprehensive Cervical Dystonia Rating Scale. This is a modular scale with modifications of the Toronto Western Spasmodic Torticollis Rating Scale (composed of three subscales assessing motor severity, disability, and pain) now referred to as the revised Toronto Western Spasmodic Torticollis Scale‐2; a newly developed psychiatric screening instrument; and the Cervical Dystonia Impact Profile‐58 as a quality of life measure. Methods Ten dystonia experts rated subjects with cervical dystonia using the comprehensive scale. Clinimetric techniques assessed each module of the scale for reliability, item correlation, and factor structure. Results There were 208 cervical dystonia patients (73% women; age, 59 ± 10 years; duration, 15 ± 12 years). Internal consistency of the motor severity subscale was acceptable (Cronbach's alpha = 0.57). Item to total correlations showed that elimination of items with low correlations (<0.20) increased alpha to 0.71. Internal consistency estimates for the subscales for disability and pain were 0.88 and 0.95, respectively. The psychiatric screening scale had a Cronbach's alpha of 0.84 and satisfactory item to total correlations. When the subscales of the Toronto Western Spasmodic Torticollis Scale‐2 were combined with the psychiatric screening scale, Cronbach's alpha was 0.88, and construct validity assessment demonstrated four rational factors: motor; disability; pain; and psychiatric disorders. The Cervical Dystonia Impact Profile‐58 had an alpha of 0.98 and its construction was validated through a confirmatory factor analysis. Conclusions The modules of the Comprehensive Cervical Dystonia Rating Scale are internally consistent with a logical factor structure. © 2016 International Parkinson and Movement Disorder Society
Cardiovascular Implantable Electronic Device Infections due toPropionibacteriumSpecies
Rafei, Abdelghani El , Sohail, M. Rizwan , Steckelberg, James M., Wilson, Walter R. , El Rafei, Abdelghani, DeSimone, Daniel C. , DeSimone, Christopher V. , Baddour, Larry M. , Sohail, M Rizwan

Pacing and Clinical Electrophysiology | March 12, 2016 | Volume: 39 | Issue: 6 | Pages: 522-530

10.1111/pace.12845 | PMID 26970081 Get It