Citations

Mayo Clinic

Showing 10 of 108602 citations.

Risk of Different Cancers Among First-degree Relatives of Pancreatic Cancer Patients: Influence of Probands’ Susceptibility Gene Mutation Status
Antwi, Samuel O. , Fagan, Sarah , Chaffee, Kari G. , Hu, Chunling , Lilyquist, Jenna , Oberg, Ann L. , Petersen, Gloria M. , Rabe, Kari G. , Polley, Eric C. , Hart, Steven N. , Shimelis, Hermela , Gnanaolivu, Rohan D., McWilliams, Robert R. , Antwi, Samuel O , Hu, Chunling , Bamlet, William R. , Gnanaolivu, Rohan , Couch, Fergus J.

JNCI: Journal of the National Cancer Institute | November 27, 2017 | Volume: 111 | Issue: 3 | Pages: 264-271

10.1093/jnci/djx272 | PMID 29982661 Get It

Objective Versus Self-Reported Sleep Quality at High Altitude
Anderson, Paul J., Wood‐Wentz, Christina M. , Bailey, Kent R., Johnson, Bruce D.

High Altitude Medicine & Biology | November 27, 2017 | Volume: 24 | Issue: 2 | Pages: 144-148

10.1089/ham.2017.0078 | PMID 29172727 Get It

Anderson, Paul J., Christina M. Wood-Wentz, Kent R. Bailey, and Bruce D. Johnson. Objective versus self-reported sleep quality at high altitude. High Alt Med Biol . 24:144–148, 2023. Background: Previous studies have found little relationship between polysomnography and a diagnosis of acute mountain sickness (AMS) using the Lake Louise Symptom Questionnaire (LLSQ). The correlation between sleep question responses on the LLSQ and polysomnography results has not been explored. We compared LLSQ sleep responses and polysomnography data from our previous study of workers rapidly transported to the South Pole. Methods: Sixty-three subjects completed a 3-hour flight from sea level to the South Pole (3200 m, 9800 ft). Participants completed limited overnight polysomnography on their first night and completed LLSQ upon awakening. We compared polysomnography results at the South Pole with sleep question responses on the LLSQ to assess their degree of correspondence. Results: Twenty-two (30%) individuals reported no sleep problems whereas 20 (32%) reported some problems and 20 (33%) individuals reported poor sleep and 1 reported no sleep ( n = 1). Median sleep efficiency was (94%) among response groups and mean overnight oxygen saturation was 81%. Median apnea hypopnea index (AHI; events/hour) was 10.2 in those who reported no problems sleeping, 5.1 in those reporting some problems sleeping, and 13.7 in those who reported poor sleep. These differences were not statistically significant. Conclusion: Self-reported sleep quality varied but there were no associated significant differences in sleep efficiency, overnight oxygen saturation, nor AHI. Studies that explore the role of objective sleep quality in the development of AMS should remove the sleep question on the LLSQ from AMS scoring algorithms.
Deceased organ donor screening for human immunodeficiency virus, hepatitis B virus and hepatitis C virus: Discordant serology and nucleic acid testing results
Theodoropoulos, Nicole , Nowicki, Marek, Chinchilla-Reyes, C., Dionne, Sara, Jaramillo, Andrés , Mone, Tom, Hasz, Richard , Jendrisak, Martin D., Ladner, Daniela P. , Ison, Michael G. , Ison, M G , Dionne, Sara O. , Ladner, Daniela P , Jaramillo, Andres

Transplant Infectious Disease | November 27, 2017 | Volume: 20 | Issue: 1 | Pages: No page available

10.1111/tid.12821 | PMID 29178242 Get It

AbstractBackgroundBefore the 2014 policy change pertaining to infectious disease screening, many organ procurement organizations (OPOs) were supplementing serologic screening of deceased organ donors with nucleic acid testing (NAT) for human immunodeficiency virus (HIV‐1), hepatitis B virus (HBV), and hepatitis C virus (HCV). The number of seronegative,NAT‐positive donors has not been directly measured.MethodsHIV,HBV, andHCVscreening results of 11 229 donor referrals evaluated from 2010 to 2013 were obtained from 3OPO‐affiliated laboratories, capturing 35% of all donors in the United States. Laboratories used either polymerase chain reaction assay or transcription‐mediated amplification assay to test 9643 deceased donors byNAT.ResultsTheNATresults were positive in 21 (0.2%), 1 (0.02%), and 11 (0.1%) donors who were seronegative forHIV,HBV, andHCV, respectively. All discordantHIV‐1 results were from one laboratory using a polymrease chain reaction assay. Thirteen of the reactiveHIV NATresults in seronegative referrals were repeated and were non‐reproducibly positive (NRP). Ten (0.1%), 452 (7.8%), and 197 (2.2%) ofHIV‐,HBV‐, andHCV‐seropositive donors, respectively, were negative byNAT.ConclusionsThis study highlights the importance of robust quality assurance to minimizeNRP NATresults.NATmay allow for increased utilization of organs fromHBV‐ andHCV‐seropositive,NAT‐negative donors.
Pazopanib for renal cell carcinoma leads to elevated mean arterial pressures in a murine model
Kempton, Amber, Justice, Cody N. , Guo, Aaron , Cefalu, Matthew , Makara, Michael, Ho, Thai H. , Smith, Sakima A. , Ho, Thai , Janssen, Paul M.L.

Clinical and Experimental Hypertension | November 27, 2017 | Volume: 40 | Issue: 6 | Pages: 524-533

10.1080/10641963.2017.1403623 | PMID 29172746 Get It

Diagnostic utility of surgical lung biopsies in elderly patients with indeterminate interstitial lung disease
Vaszar, Laszlo T. , Larsen, Brandon T. , Swanson, Karen L., Ryu, Jay H. , Tazelaar, Henry D. , Ryu, Jay H , Tazelaar, Henry D.

Respirology | November 27, 2017 | Volume: 23 | Issue: 5 | Pages: 507-511

10.1111/resp.13223 | PMID 29178216 Get It

AbstractBackground and objectiveIdiopathic pulmonary fibrosis (IPF) is increasingly diagnosed by clinical and computed tomography (CT) criteria; however, surgical lung biopsy (SLB) may still be required in patients who lack definite CT features of usual interstitial pneumonia (UIP). We reviewed a cohort of elderly patients who underwent SLB, to evaluate the benefit of SLB in diagnosing idiopathic interstitial pneumonia (IIP).MethodsWe searched the pathology records of Mayo Clinic for ambulatory patients at least 75 years old, who underwent SLB between 2000 and 2012 for indeterminate IIP. Histologic slides were reviewed and clinical data were extracted from the record.ResultsA total of 55 patients (35 male) were enrolled. Median (interquartile range) age was 77 (76–80) years. Forced vital capacity was 70 (61–76)% and diffusing capacity of the lungs for carbon monoxide was 48 (42–54)% of predicted. In total, 37 (67%) patients had IPF, including 61% of those with HRCT findings inconsistent with UIP. Thirty‐day mortality was 10% and 90‐day mortality was 15%.ConclusionThe high mortality rate of SLB complicates the risk–benefit analysis in elderly patients with IIP. The expected value of the SLB is probably highest when the HRCT features are inconsistent with UIP, due to the frequent (39%) retrieval of patterns other than UIP.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Diehn, Felix E. , Michalak, Gregory J. , Kotsenas, Amy L. , Lindell, E. Paul , Halaweish, Ahmed F., DeLone, David R. , Campeau, Norbert G , Halaweish, Ahmed F , Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G. , Diehn, Felix E

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 | PMID 29225924 Get It

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.
Can time to failure predict the faulty component in artificial urinary sphincter device malfunctions?
Yang, David Y. , Linder, Brian J. , Miller, Adam R. , Rangel, Laureano J. , Elliott, Daniel S. , Yang Md, David , Linder, Brian J

International Journal of Urology | November 26, 2017 | Volume: 25 | Issue: 2 | Pages: 146-150

10.1111/iju.13485 | PMID 29178540 Get It

ObjectiveArtificial urinary sphincter malfunctions can occur in any of the individual components. Preoperative identification of the malfunctioning component can be valuable for patient counseling and surgical planning. The optimal strategy for repair of failed artificial urinary sphincter components is debated given the relative rarity of the situation. The aim of the present study was to evaluate the relationship of time to failure with failed artificial urinary sphincter component and to compare our outcomes of specific component versus complete device replacement.MethodsFrom 1983 to 2011, 1805 artificial urinary sphincter procedures were carried out at Mayo Clinic (Rochester, Minnesota, USA), of which 1072 patients underwent primary artificial urinary sphincter placement. Clinical variables, including time to failure, were evaluated for association with component failure. Bootstrap analysis was used to estimate the differences in time to reach a fixed percentage of component failure.ResultsA total of 115 patients experienced device failure at a median follow up of 4.2 years. Urethral cuff, abdominal reservoir, scrotal pump and tubing malfunction occurred in 53 (4.9%), 26 (2.4%), 11 (1%) and 25 (2.3%) patients, respectively. Increasing age at the time of primary surgery was protective of cuff malfunction (hazard ratio 0.97, P = 0.04). Time to 3% urethral cuff failure outpaced other component failures (P < 0.05). Secondary failure‐free rates after whole device versus specific component revisions were comparable (P = 0.38).ConclusionsClinical predictors for artificial urinary sphincter failure continue to be difficult to establish. Although single component versus entire device replacement have similar outcomes, if pursuing single component revision, we recommend cuff‐first interrogation in devices in place for >3 years, as this represents the most likely component to fail.
A Mysterious DRESS Case: Autoimmune Enteropathy Associated with DRESS Syndrome
Adike, Abimbola , Boppana, Vaishnavi, Lam‐Himlin, Dora , Stanton, Melissa, Nelson, Steven B., Ruff, Kevin C. , Nelson, Steven

Case Reports in Gastrointestinal Medicine | November 26, 2017 | Volume: 2017 | Issue: No issue available | Pages: 1-5

10.1155/2017/7861857 | PMID 29333302 Get It

Drug Reaction with Eosinophilia and Systemic Symptoms (DRESS) is a rare but potentially life-threatening cutaneous hypersensitivity reaction characterized by extensive mucocutaneous eruption, fever, hematologic abnormalities, and extensive organ involvement. Here, we present a case of a young woman with DRESS syndrome following exposure to vancomycin with renal, cutaneous, and gastrointestinal involvement. To the best of our knowledge, this is the first case description in the literature of DRESS of the gastrointestinal tract with autoimmune enteropathy.
Three‐dimensional virtual cystoscopy: Noninvasive approach for the assessment of urinary tract in fetuses with lower urinary tract obstruction
Werner, Heron , Ribeiro, Gerson , Jesús, Nilson Ramires de , Santos, Gildásio Rocha, Alexandria, Helenara Abadia Ferreira, Júnior, Edward Araujo , Ruano, Rodrigo , Araujo Júnior, Edward , Lopes, Jorge

Prenatal Diagnosis | November 25, 2017 | Volume: 37 | Issue: 13 | Pages: 1350-1352

10.1002/pd.5188 | PMID 29178428 Get It

What is already known about this topic? Lower urinary tract obstruction is associated with high morbidity and mortality. Fetal cystoscopy may allow the correct identification of the etiology of the obstruction and may provide the adequate treatment. What does this study add? Three‐dimensional virtual navigation is a noninvasive approach that provides an immersive virtual reality in the assessment of fetal structures. Three‐dimensional virtual cystoscopy provides a noninvasive evaluation of fetal lower urinary tract obstruction that in the future may help in the selection of candidates for fetal cystoscopy.