Spatiotemporal clutter filtering methods for in vivo microvessel imaging
Song, Pengfei , Song, Pengfei , Chen, Shigao

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1900-1900

10.1121/1.5036186 Get It

Ultrafast plane wave imaging enables acquisition and accumulation of a large number of Doppler ensembles in a short period of time, which substantially boosts ultrasound Doppler sensitivity by at least an order of magnitude. As a key component, spatiotemporal clutter filtering based on singular value decomposition (SVD) has recently demonstrated superior performance in tissue clutter suppression and microvessel signal extraction over conventional high-pass-filter-based clutter filtering techniques. This presentation introduces several novel SVD clutter filter techniques from our recent work, focusing on addressing the technical challenges (complex tissue motion, high computational cost, and noise) of SVD clutter filter during clinical translations of the ultrafast microvessel imaging technology for human imaging. We present a block-wise adaptive SVD filter method that can robustly threshold singular values on a local level, a real-time feasible SVD clutter filtering method based on partial SVD and randomized spatial downsampling, and a noise equalization and suppression method that can significantly improve microvessel imaging quality at a low cost. In vivo performance of these methods will be demonstrated in different organs.
Phantom study of flow speed measurement using ultrafast ultrasound plane wave imaging
Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1901

10.1121/1.5036189 Get It

Color flow imaging is an ultrasound imaging technique widely used to image the blood movement through arteries and veins. Quantification of velocity is urgently demanding. The objective of this study is to use ultrafast plane wave imaging to measure the flow in speed in vitro. For the flow phantom, the diagonal vessel (2-mm inner diameter at 40° angle) was studied with injection of blood mimic fluid via syringe pump at various volume rates (15, 20, 25, and 30 ml/min). Verasonics Vantage system (Verasonics Inc., Kirkland, WA, USA) and a linear array transducer L11-4v (Verasonics Inc., Kirkland, WA, USA) were used for ultrasound acquisition, a 8-angle (−7° to 7°) plane wave compounding with effective pulse-repetition frequency (PRF) of 1000 Hz was used (central frequency = 6.42 MHz, number of transmit cycles = 4). A total of 600 ensembles were acquired. The frame rate was 1000/s.[XZ1] [BZ2] The ultrasound in-phase quadrature data size was 195 × 156 × 600 (axial x lateral x temporal) with data type of complex double. Singular value decomposition (SVD)-based ultrasound blood flow clutter filters was used for ultrafast plane wave imaging.[XZ3] [BZ4] Randomized SVD was utilized to filter noise and tissue motion. Power Doppler image was generated. The color flow images were generated by using the 2-D autocorrelation method. Results showed that color flow measurement can quantitatively evaluate the flow speed in the tube of the flow phantom.
Multi-resolution rank analysis for non-contrast ultrasound imaging of slow flow
Bayat, Mahdi , Alizad, Azra , Fatemi, Mostafa

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1901

10.1121/1.5036188 Get It

While conventional filtering techniques can effectively exclude tissue-related Doppler shifts from those resulting from blood motions in large vessels (flow rates ~ cm/s), significant spectral overlap can hinder proper clutter filtering in imaging slow flows (flow rates ~ mm/s or tenths of mm/s). Recently, several groups have proposed clutter filtering via processing of echo ensembles in the rank space instead of frequency domain. Though significant Doppler content can result from fast moving tissues, global coherence of the induced variations enables a low rank representation. In this talk, we first provide a brief overview of the low rank clutter removal methods. We then present a new framework for the analysis of Doppler ensembles using multi-linear decomposition of a tensor comprising Doppler ensembles at different rates. The model results in a high dimensional tensor from which, after proper rank selection, images of flow at different speeds can be extracted along different fibers. Using simulation models, we demonstrate the superior performance of the proposed method over singular value clutter filtering in imaging small vessels embedded in moving tissue undergoing both translational and shearing motions. We also present in vivo examples where the proposed method provides significant blood to clutter + noise ratio enhancement compared to singular value clutter filtering.
Quantitative morphological analysis of microvasculature in thyroid nodules using non-contrast high-resolution Doppler imaging
Ghavami, Siavash , Gregory, Adriana , Kim, Bae Hyeong, Viksit, Kumar, Webb, Jeremy, Bayat, Mahdi , Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1901-1902

10.1121/1.5036190 Get It

We hypothesize that pattern of microvasculature in the thyroid nodules can be a biomarker of thyroid cancer. In this study, morphological features of microvasculature networks are assessed as potential biomarkers for differentiation of benign, suspicious and malignant thyroid nodules. This prospective study included n = 81 patients, with a total of 61 benign, 12 suspicious and 8 malignant nodules verfied by pathology and cytology findings. Thyroid nodules were first identified using conventional B-mode ultrasound. A sequence of raw ultrasound data were acquired from each nodule site in two perpendicular planes at ~600 frames/sec. Power Doppler image of the microvasculature was formed using singular value decomposition clutter removal filtering. Gross images were further processed using a combination of morphology and Hessian-based vessel enhancement filtering. Background-free images of the microvasculature networks were segmented (vessels segment length >385μm and diameter >90μm) for morphological analysis. Using a Bayesian framework, measures of vessels density, diameter and tortuosity were tested for significant differences in the three groups. Among all measures, the probability of vessel diameter >600μm in benign cases was significantly higher than that in malignant cases with the p-value <0.01 using Wilcoxon-Rank-Sum test, suggesting reliable cancer detection performance of the proposed method. [Acknowledgment: NIH Grant EB17213.]
Compound speckle model demonstrates two-phase wash-in of contrast-enhanced ultrasound cine loops
Lacefield, James C. , Lowerison, Matthew R. , Chambers, Ann F. , Leong, Hon S. , Power, Nicholas Edgar

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1902-1902

10.1121/1.5036191 Get It

During contrast-enhanced ultrasound (CEUS) imaging of tumor microvascular perfusion, nearby arteriole enhancement can be a dominant feature of the wash-in kinetics that obscures the perfusion characteristics of the capillary bed. This presentation demonstrates that statistical wash-in curves generated using our compound CEUS speckle model1 exhibit two distinct phases corresponding to “fast-flow” and “slow-flow” enhancement that can be detected by fitting a linear combination of two monoexponential functions with different time constants. CEUS cine loops were acquired from a patient-derived xenograft model of renal cell carcinoma, where fresh tumor fragments were engrafted into the chicken embryo chorioallantoic membrane. Subharmonic CEUS images were acquired at 18 MHz using a destruction-replenishment protocol. Enhancement of manually segmented tumor cross-sections was analyzed offline in MATLAB. The CEUS cine loops from this xenograft model frequently exhibited in-plane arteriole enhancement. The two-phase fit discriminated a slow-flow component in 26.6% of time-intensity wash-in curves and 62.9% of the statistical wash-in curves, leading to a decrease in estimated tumor blood volume by 22.1% and 24.7%, respectively, compared to a simple monoexponential fit. These results suggest that conventional CEUS processing may frequently overestimate capillary blood volume. 1M.R. Lowerison et al., Med. Phys. 44, 99-111 (2017).
Lung ultrasound surface wave elastography for assessing interstitial lung disease
Clay, Ryan , Zhou, Jinling , Osborn, Thomas G. , Greenleaf, James F. , Kalra, Sanjay , Zhang, Xiaoming , Zhou, Boran , Bartholmai, Brian J.

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1776-1776

10.1121/1.5035812 Get It

A lung ultrasound surface wave elastography (LUSWE) technique is developed for assessing interstitial lung disease (ILD). In LUSWE, a 0.1 second harmonic vibration is generated on the chest wall of a subject using a handheld vibrator. An ultrasound probe is aligned with the vibration indenter in the same intercostal region to measure the generated surface wave speed of the lung. A human subject is examined in a sitting position. The lung is tested at the total lung volume. The upper anterior lungs are tested through the second intercostal space in the mid-clavicular line. The lower lateral lungs are tested in the mid-axillary line and the lower posterior lungs are tested in the mid-scapular line. In a prospective clinical study, we measure both lungs through the six intercostal regions for patients and healthy controls. The surface wave speed is measured at 100 Hz, 150 Hz, and 200 Hz. Significant differences of wave speed between patients and controls were found in all lung regions at all frequencies. We also found positive correlation between LUSWE and CT analyses. LUSWE is a safe and noninvasive technique for generating and measuring surface wave propagation on the lung. LUSWE may be useful for assessing ILD.
A deep neural network method for analyzing lung density using lung ultrasound surface wave elastography
Zhou, Boran , Zhang, Xiaoming

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1803-1803

10.1121/1.5035903 Get It

Lung density is directly associated with lung pathology. Computed Tomography (CT) evaluates lung pathology using the Hounsfield unit (HU) but not directly the lung density. We recently developed a lung ultrasound surface wave elastography (LUSWE) technique for measuring the surface wave speed of superficial lung tissue. The objective of this study is to analyze lung density of superficial lung tissue using deep neural network (DNN) and wave speed measurements obtained from LUSWE. The synthetic training dataset (7,88,000 in total) in terms of wave speeds of superficial lung tissue at different excitation frequencies from LUSWE, viscoelasticity and density of lung tissue was used to train the DNN. DNN is composed of 3 hidden layers of 1024 neurons and trained for 10 epochs with a batch size of 4096 and a learning rate of 0.001 with Adam optimizer. Test dataset in terms of wave speeds at different excitation frequencies (100, 150, and 200 Hz) as well as elasticity was used to predict the lung density and evaluate its accuracy. The obtained results showed that predictions matched well with test dataset (validation accuracy is 0.997). This method may be useful to analyze lung density based on the LUSWE measurements.
Quantifying nonlinear elasticity modulus of tissue-like solids using acoustic radiation force
Panahandeh-Shahraki, Danial, Kinnick, Randall R., Ghavami, Siavash , Guzina, Bojan B. , Kumar, Viksit , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035900 Get It

As shown in a recent study, estimation of the magnitude of the acoustic radiation force (ARF) in isotropic tissue-like solids is the key to measuring a third-order nonlinear modulus of elasticity (C)—responsible for coupling the shear and volumetric constitutive responses of a material. Due to experimental limitations, a direct measurement of the ARF in tissue is however difficult. To overcome this problem, we deploy 3D elastodynamic finite element (EFE) simulations of the ARF experiment in tissue-mimicking phantoms to estimate (i) the “background” shear modulus from the phase of the induced shear waves; (ii) the ARF magnitude from the shear wave amplitude, and (iii) the modulus C from the knowledge of the ARF. In this way, by interpreting the ARF-generated shear waves through the prism of 3D-EFE simulations, we facilitate local estimation of the nonlinear C modulus with spatial resolution equaling the size of the focal region. We call this method the C-Elastography (CE). In this study, the CE technique is applied to gelatin phantoms containing an agar-based inclusion. The profiles of the C-modulus in phantoms tested demonstrate good correlation with the phantom geometry, showing marked (and sharp) C-contrast at push points acting on the inclusion. [Acknowledgment: NIH-Grant EB23113.]
Parametric phantom study of shear wave velocity image reconstruction
Racedo, Jorge , Urban, Matthew W.

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035899 Get It

Shear wave elastography is being increasingly used for multiple applications including investigation of diffuse disease in the liver or kidney and malignancies or neoplasms in the breast and thyroid. It is important to provide robust and accurate reconstructions of shear wave velocity (SWV) for imaging purposes to provide reliable data for diagnosis. One such approach was a two-dimensional method for estimating SWV (Song, et al., Ultrasound Med. Biol. 40, pp. 1343–1355, 2014). This method uses a weighted average using a large window and smaller patches to perform time-domain cross-correlations for the calculation of the SWV. We also implemented a spatial sigmoid weighting to combine reconstruction results from independent reconstructions after directional filtering. We used a Verasonics system equipped with a linear array transducer to conduct a parametric study in phantoms to investigate the effects of the window and patch on image reconstruction metrics. Measurements were made in homogeneous phantoms and in a phantom with cylindrical inclusions of different diameters. Larger windows and patches typically yielded low variability but did not always produce the highest contrast. This investigation is the basis for an adaptive method for reconstructing SWV in soft tissues and choosing optimal parameters for the SWV reconstruction.
Vibro-acoustic method for detection of osteopenia and osteoporosis
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Denis, Max , Bayat, Mahdi , Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1801-1801

10.1121/1.5035894 Get It

Early detection of osteopenia and osteoporosis is critical in identifying at-risk groups and manage necessary therapy. In this paper, a new noninvasive and quantitative vibro-acoustic method is proposed for detection of osteoporosis and osteopenia. In this method, we excite the bone by an ultrasound radiation force (URF) pulse. The URF pulse induces a vibration in the bone, resulting an acoustic wave that is received by a hydrophone placed on the skin. This prospective study included n = 23 volunteers. The number of volunteers with osteopenia and osteoporosis were 7, 6, respectively, and the number of volunteers with normal bone was 10. URF excitations were applied at four equi-distance points on the bone. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. In general, the hydrophone signal may be modeled as a superposition of different modes of bone vibration. Based on this model, we used variational mode decomposition (VMD) as an efficient technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions. Statistical analysis demonstrates that osteopenia and osteoporosis bones can be differentiated from normal bone with p< 0.001 using Wilcoxon rank-sum test on estimated velocity of the modes with maximum power.