Papilledema is optic nerve swelling caused by increased intracranial hypertension, which has the potential to cause significant vision loss. Papilledema from idiopathic intracranial hypertension (IIH) is typically bilateral and symmetric, but can sometimes be asymmetric and even unilateral. The cause for this asymmetry is unknown. The purpose of this study was to develop ultrasound vibro-elastography (UVE) for assessing patients with papilledema to evaluate for biomechanical differences in these eyes. Nine patients with papilledema from IIH and 9 age-matched healthy control subjects were enrolled. A local harmonic vibration was used to generate wave propagation through the eyelid. Three excitation frequencies of 100, 150, and 200 Hz were used. A 6.4 MHz ultrasound probe was used to measure wave propagation in the eye structures. Wave speeds were measured in the posterior sclera of the maculae. The magnitudes of the wave speed of the IIH patients’ posterior sclera were significantly higher than those of healthy subjects. In patients with unilateral papilledema, the wave speed of the posterior sclera were higher in the eyes with papilledema than in the contralateral eyes without papilledema. UVE provides a noninvasive technique to measure the wave speed of posterior sclera, which is stiffer in eyes with papilledema.
Comparison of Corneal Wave Speed and Ocular Rigidity in Normal and Glaucomatous Eyes
Precis: Ocular biomechanics were compared between treated glaucoma patients and healthy subjects matched for age, intraocular pressure (IOP), and axial length. There was no difference in corneal wave propagation speed, but ocular rigidity was lower in glaucomatous eyes. Purpose: Ocular biomechanical properties are important in understanding glaucoma pathogenesis but the affected tissues are unclear. In this study, we compared corneal wave speed (a measure of corneal elasticity) and ocular rigidity coefficient between glaucomatous and normal eyes. Materials and Methods: Twenty glaucomatous eyes from 10 patients and 20 normal eyes from 13 controls, matched for age, IOP, and axial length were included. Ocular rigidity was calculated based on the difference in supine IOP by pneumatonometry with and without a 10-g weight. Corneal wave speed was determined by ultrasound surface wave elastography. A small, 0.1-second harmonic vibration at 100 Hz was generated through the closed eyelids. Wave propagation was captured by an ultrasound transducer, and wave speed was determined from the phase change with distance. Comparisons were performed using generalized estimating equation models. Results: There were no significant differences in corneal wave speed between glaucomatous and normal eyes (2.16±0.25 vs. 2.07±0.16 m/s, P=0.17). However, ocular rigidity was significantly lower in glaucomatous eyes (0.0218±0.0033 vs. 0.0252±0.0050/μL, P=0.01). Corneal wave speed was not correlated with age and IOP in either group (P≥0.23) but was correlated with ocular rigidity (R=0.48, P=0.02) and inversely correlated with axial length (R=−0.53, P=0.01) in glaucomatous eyes. Conclusion: Glaucomatous eyes tend to have lower ocular rigidity than healthy eyes with similar age, IOP, and axial length. However, the lack of a difference in corneal wave speed suggests that corneal tissue may not be significantly affected, and scleral changes likely play a more important role in glaucoma.
Lung mass density prediction using machine learning based on ultrasound surface wave elastography and pulmonary function testing
Objective: The objective of this study is to predict in vivo lung mass density for patients with interstitial lung disease using different gradient boosting decision tree (GBDT) algorithms based on measurements from lung ultrasound surface wave elastography (LUSWE) and pulmonary function testing (PFT). Methods: Age and weight of study subjects (57 patients with interstitial lung disease and 20 healthy subjects), surface wave speeds at three vibration frequencies (100, 150, and 200 Hz) from LUSWE, and predicted forced expiratory volume (FEV1% pre) and ratio of forced expiratory volume to forced vital capacity (FEV1%/FVC%) from PFT were used as inputs while lung mass densities based on the Hounsfield Unit from high resolution computed tomography (HRCT) were used as labels to train the regressor in three GBDT algorithms, XGBoost, CatBoost, and LightGBM. 80% (20%) of the dataset was used for training (testing). Results: The results showed that predictions using XGBoost regressor obtained an accuracy of 0.98 in the test dataset. Conclusion: The obtained results suggest that XGBoost regressor based on the measurements from LUSWE and PFT may be able to noninvasively assess lung mass density in vivo for patients with pulmonary disease.
Exosome-Induced Vaginal Tissue Regeneration in a Porcine Mesh Exposure Model
Objectives The purpose of this study was to explore the utility of an injectable purified exosome product derived from human apheresis blood to (1) augment surgical closure of vaginal mesh exposures, and (2) serve as a stand-alone therapy for vaginal mesh exposure. Methods Sixteen polypropylene meshes (1×1–3×3 cm) were implanted in the vaginas of 7 Yorkshire-crossed pigs by urogynecologic surgeons (day 0). On day 7, group 1 underwent surgical intervention via vaginal tissue suture reclosure with (n=2 pigs, n=4 meshes) or without (n=2 pigs, n=4 meshes) exosome injection; group 2 underwent medical intervention with an exosome injection (n=3, n=8 meshes). One animal in group 2 was given oral 2′-deoxy-5-ethynyluridine to track cellular regeneration. Euthansia occurred at 5 weeks. Results Mesh exposures treated with surgical closure alone experienced reexposure of the mesh. Exosome treatment with or without surgical closure resulted in partial to full mesh exposure resolution up to 3×3 cm. Exosome-treated tissues had significantly thicker regenerated epithelial tissue (208 μm exosomes-only and 217 μm surgery+exosomes, versus 80 μm for surgery-only; P < 0.05); evaluation of 2′-deoxy-5-ethynyluridine confirmed de novo regeneration throughout the epithelium and underlying tissues. Capillary density was significantly higher in the surgery+exosomes group ( P = 0.03). Surgery-only tissues had a higher inflammatory and fibrosis response as compared with exosome-treated tissues. Conclusions In this pilot study, exosome treatment augmented healing in the setting of vaginal mesh exposure, reducing the incidence of mesh reexposure after suture closure and decreasing the area of mesh exposure through de novo tissue regeneration after exosome injection only. Further study of varied local tissue conditions and mesh configurations is warranted.
Grading Bleomycin‐Induced Pulmonary Fibrosis in ex vivo Mouse Lungs Using Ultrasound Image Analysis
ObjectivesThe aim of this study was to assess bleomycin‐induced pulmonary fibrosis on ex vivo mouse lungs using ultrasound image grading and texture analysis.MethodsExcised mouse lungs were divided into 3 groups: control, mild fibrosis, and severe fibrosis based on the monitored indicators of health. B‐mode ultrasound images were obtained via scanning the mouse lungs ex vivo. The surface smoothness, echo density, and angle of lesions or the lung margin were graded, and the imaging contrast, correlation, homogeneity, and entropy were assessed via texture analysis.ResultsThe grades of surface smoothness, echo density, and angle were statistically higher for the severe fibrosis group compared with those of the control and mild fibrosis groups (P < .05). In addition, statistically significant differences in the contrast, correlation, and homogeneity between mild and severe fibrosis groups were observed (P < .05).ConclusionsThe results obtained in this study suggest that ultrasound image grading and texture analysis are valuable and meaningful methods for assessing pulmonary fibrosis in a bleomycin mouse model.
Ultrasound Vibroelastography for Evaluation of Secondary Extremity Lymphedema
Background Lymphedema treatment is an ongoing challenge. It impacts quality of life due to pain, loss of range of motion of the extremity, and repeated episodes of cellulitis. Different modalities have been used to evaluate lymphedema; some are more error-prone and some are more invasive. However, these measurements are poorly standardized, and intrarater and interrater reliabilities are difficult to achieve. This pilot study aims to assess the feasibility of ultrasound vibroelastography for assessing patients with extremity lymphedema via measuring shear wave speeds of subcutaneous tissues. Methods Patients with clinical and lymphoscintigraphic diagnosis of secondary lymphedema in the extremities without prior surgical treatment were included. A 0.1-s harmonic vibration was generated at three frequencies (100, 150, and 200 Hz) by the indenter of a handheld shaker on the skin. An ultrasound probe was used for noninvasively capturing of wave propagation in the subcutaneous tissue. Wave speeds were measured in the subcutaneous tissues of both the control and affected extremities. Results A total of 11 female patients with secondary lymphedema in the extremities were enrolled in this study. The magnitudes of the wave speeds of the region of interest in the subcutaneous tissue at lymphedema sites in the upper extremity (3.9 ± 0.17 m/s, 5.96 ± 0.67 m/s, and 7.41 ± 1.09 m/s) were statistically higher than those of the control sites (2.1 ± 0.27 m/s, 2.93 ± 0.57 m/s, and 3.56 ± 0.76 m/s) at 100, 150, and 200 Hz (P < 0.05), and at 100 and 200 Hz (P < 0.05) between lymphedema (4.33 ± 0.35 m/s, 4.17 ± 1.00 m/s, and 4.56 ± 0.37 m/s) and controls sites (2.48 ± 0.43 m/s, 2.77 ± 0.55 m/s, and 3.06 ± 0.29 m/s) in the lower extremity. Conclusions These preliminary data suggest that ultrasound vibroelastography may be useful in the evaluation of secondary lymphedema and can be a valuable tool to noninvasively track treatment progress.
Quantification of lung surface wave speed in a water-filled lung: An ex vivo swine lung study
Lung edema is a common symptom of congestive heart failure and inflammatory conditions, such as acute respiratory distress syndrome. Currently, computed tomography (CT) is considered the standard to assess lung edema, but it requires ionizing radiation and poses a significant logistic burden. Lung ultrasound (LUS) has previously been used to assess lung edema using ultrasound B-line artifacts, but analysis of the B-line artifacts relies on visual interpretation. We developed lung ultrasound surface wave elastography (LUSWE) to measure lung surface wave speed safely. This project aims to evaluate LUSWE to quantify lung surface wave speed in an ex vivo water-filled swine lung. The lung surface wave speeds were measured at baseline and at frequencies of 100 Hz, 200 Hz, 300 Hz, and 400 Hz. Then, an amount of water was filled into the lung through its trachea. Ultrasound imaging was used to guide the water filling until significant changes were visible on the imaging. The lung surface wave speeds were measured. An additional 120 ml of water was then filled into the lung. The lung surface wave speeds were measured again. The results demonstrated that the lung surface wave speed decreased with respect to water content.
Ultrasound surface wave elastography for assessing extremity lymphedema: A pilot clinical study
Lymphedema is a condition in which protein-rich fluid accumulates in the tissue causing impaired limb function from swelling and stiffness. Understanding the mechanical properties of soft tissue in lymphedematous limbs is important in clinical diagnosis. We recently developed an ultrasound surface wave elastography (USWE) technique for measuring the shear wave speed of tissue. The aim of this study is to evaluate lymphedematous limb use USWE. A total of 11 patients with lymphedema were included. Both normal and affected extremities were measured. A 0.1-s harmonic vibration was generated by the indenter of the handheld shaker on the limb. Ultrasound probe was used for detecting the tissue motion. Shear wave speed of the tissue was measured using 2-D processing window technique. A region of interest was selected to measure superficial and deep fat tissues. The obtained results showed that the magnitudes of the wave speeds of both the superficial and deep fat tissue at lymphedema sites were statistically higher than those of the control sites, respectively. This suggests that USWE may be useful in assessing correlation between tissue stiffness and lymphedema and would enable physicians to monitor disease severity.
A Pilot Study of Wet Lung Using Lung Ultrasound Surface Wave Elastography in an Ex Vivo Swine Lung Model
Extravascular lung water (EVLW) is a basic symptom of congestive heart failure and other conditions. Computed tomography (CT) is standard method used to assess EVLW, but it requires ionizing radiation and radiology facilities. Lung ultrasound reverberation artifacts called B-lines have been used to assess EVLW. However, analysis of B-line artifacts depends on expert interpretation and is subjective. Lung ultrasound surface wave elastography (LUSWE) was developed to measure lung surface wave speed. This pilot study aimed at measureing lung surface wave speed due to lung water in an ex vivo swine lung model. The surface wave speeds of a fresh ex vivo swine lung were measured at 100 Hz, 200 Hz, 300 Hz, and 400 Hz. An amount of water was then filled into the lung through its trachea. Ultrasound imaging was used to guide the water filling until significant changes were visible on the imaging. The lung surface wave speeds were measured again. It was found that the lung surface wave speed increases with frequency and decreases with water volume. These findings are confirmed by experimental results on an additional ex vivo swine lung sample.
Evaluation of posterior sclera viscoelasticity in eyes with papilledema by using ultrasound vibro-elastography
Papilledema is optic nerve swelling caused by increased intracranial pressure, which has the potential to cause significant vision loss. Papilledema is typically bilateral and symmetric but can sometimes be asymmetric and even unilateral. The cause for this asymmetry is unknown. The purpose of this study was to utilize ultrasound vibro-elastography (UVE) to assess for biomechanical differences in eyes with papilledema. Nine patients with papilledema and 9 age-matched controls were enrolled. An external harmonic vibration was used to generate wave propagation through the eyelid with three excitation frequencies of 100, 150, and 200 Hz. A 6.4 MHz ultrasound probe was used to noninvasively measure the wave propagation in the posterior sclera to provide shear wave speeds and viscoelasticity (fit with Voigt model). The magnitudes of the shear wave speed and viscoelasticity of the idiopathic intracranial hypertension patients’ posterior sclera were significantly higher than those of healthy subjects. Moreover, for patients with unilateral papilledema, the magnitudes of wave speed and viscoelasticity of the posterior sclera were statistically higher in eyes with papilledema than in the contralateral eyes without papilledema. UVE provides a noninvasive technique to measure the viscoelastic properties of the posterior sclera, which is stiffer in eyes with papilledema.