Back to Authors

Denis, Max

https://orcid.org/0000-0002-5750-2197

Mayo Clinic

Mayo Clinic

Citations 9

Evaluation of bone fracture healing in children using acoustic radiation force: Initial in vivo results
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Denis, Max , Milbrandt, Todd A. , Kumar, Viksit , Larson, A. Noelle , Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | April 24, 2019 | Volume: 145 | Issue: 3_Supplement | Pages: 1893-1893

10.1121/1.5101860 Get It

Vibrational characteristics of the bone are directly dependent on bone’s physical properties. In this paper, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on acoustic radiation force of ultrasound for bone characterization in patients with fracture. In this method, we excite the clavicle and ulna by an ultrasound radiation force (URF) pulse. The URF pulse induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. To further separate different vibration characteristics, we adopt a variational mode decomposition (VMD) technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, which allows analyzing the acoustic signals in terms of their constitutive components. We conducted a prospective study that included a total of 15 patients, 12 with clavicle fractures and 3 with ulna fractures. The contralateral intact bones were used as control. Statistical analysis demonstrated that fracture bones can be differentiated from intact bone with a detection probability of 80%. Also, we introduce a “healing factor” that quantifies the progress of healing in clavicle bones. Statistical analysis showed that healing factor can track the progress of healing in clavicle in 80% of fractures.
Ultrasound Radiation Force for the Assessment of Bone Fracture Healing in Children: An In Vivo Pilot Study
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Bayat, Mahdi , Denis, Max , Milbrand, Todd A., Larson, A. Noelle , Fatemi, Mostafa , Alizad, Azra , Kumar, Viksit, Larson, A Noelle , Alizad, Azra , Fatemi, Mostafa , Kumar, Viksit

Sensors | February 25, 2019 | Volume: 19 | Issue: 4 | Pages: 955

10.3390/s19040955 Get It

Vibrational characteristics of bone are directly dependent on its physical properties. In this study, a vibrational method for bone evaluation is introduced. We propose a new type of quantitative vibro-acoustic method based on the acoustic radiation force of ultrasound for bone characterization in persons with fracture. Using this method, we excited the clavicle or ulna by an ultrasound radiation force pulse which induces vibrations in the bone, resulting in an acoustic wave that is measured by a hydrophone placed on the skin. The acoustic signals were used for wave velocity estimation based on a cross-correlation technique. To further separate different vibration characteristics, we adopted a variational mode decomposition technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions, allowing analysis of the acoustic signals by their constitutive components. This prospective study included 15 patients: 12 with clavicle fractures and three with ulna fractures. Contralateral intact bones were used as controls. Statistical analysis demonstrated that fractured bones can be differentiated from intact ones with a detection probability of 80%. Additionally, we introduce a “healing factor” to quantify the bone healing progress which successfully tracked the progress of healing in 80% of the clavicle fractures in the study.
Vibro-acoustic method for detection of osteopenia and osteoporosis
Ghavami, Siavash , Gregory, Adriana , Webb, Jeremy, Denis, Max , Bayat, Mahdi , Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1801-1801

10.1121/1.5035894 Get It

Early detection of osteopenia and osteoporosis is critical in identifying at-risk groups and manage necessary therapy. In this paper, a new noninvasive and quantitative vibro-acoustic method is proposed for detection of osteoporosis and osteopenia. In this method, we excite the bone by an ultrasound radiation force (URF) pulse. The URF pulse induces a vibration in the bone, resulting an acoustic wave that is received by a hydrophone placed on the skin. This prospective study included n = 23 volunteers. The number of volunteers with osteopenia and osteoporosis were 7, 6, respectively, and the number of volunteers with normal bone was 10. URF excitations were applied at four equi-distance points on the bone. The resulting acoustic signals were used for wave velocity estimation based on cross-correlation technique. In general, the hydrophone signal may be modeled as a superposition of different modes of bone vibration. Based on this model, we used variational mode decomposition (VMD) as an efficient technique to decompose the received signal into an ensemble of band-limited intrinsic mode functions. Statistical analysis demonstrates that osteopenia and osteoporosis bones can be differentiated from normal bone with p< 0.001 using Wilcoxon rank-sum test on estimated velocity of the modes with maximum power.
Clinical results of ultrasound bladder vibrometry for assessment of bladder compliance
Cheong, Mathew , Denis, Max , Gregory, Adriana , Nenadic, Ivan , Husmann, Douglas A. , Mynderse, Lance A. , Bayat, Mahdi , Kumar, Viksit , Mehrmohammadi, Mohammad , Alizad, Azra , Fatemi, Mostafa

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2176-2176

10.1121/1.4950464 Get It

Healthy human bladder is a viscoelastic shell capable of expanding to allow storage of urine at low pressures. The ability to maintain low pressures as the urine volume increases is called bladder compliance. Compliance is a key in proper functioning of urinary system. Spinal cord injuries and other neurogenic diseases can cause deterioration in bladder expansion capability (e.g., through excessive growth of fibrotic tissue), which in turn can increase the rigidity of the wall and reduce bladder compliance. Urodynamic study (UDS) is the clinical standard for evaluation of the bladder compliance through observation of bladder pressure-volume behavior. However, this method is costly and invasive. Ultrasound bladder vibrometry (UBV) has been introduced as noninvasive technique for evaluation of bladder viscoelasticity through excitation of the bladder using ultrasound radiation force and tracking the resulting Lamb waves. Here, we present the results of UBV from 44 patients undergoing concurrent UDS and UBV studies. Our results show that elasticity parameters obtained from the UBV closely correlate with the UDS pressure-volume data with a median Pearson’s correlation value of more than 0.8. These results prove the potential utility of UBV as an alternative noninvasive method for bladder compliance assessment. [Work supported by NIH grant DK99231.]
Bone demineralization assessment using acoustic radiation force
Denis, Max , Wan, Leighton , Cheong, Mathew , Fatemi, Mostafa , Alizad, Azra

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2028-2028

10.1121/1.4949983 Get It

In this work, an ultrasound-guided remote measurement technique is proposed for bone demineralization assessment. Utilizing an acoustic radiation force (ARF) beam as our excitation source and a receiving hydrophone, the mechanical properties of a bone can be noninvasively assessed. Focusing the ARF beam on the bone surface acts as point force generating vibrational waves. Coupling the bone surface and hydrophone, the ensuing radiating acoustic pressure from these vibrational waves are captured for analysis. Of particular interest, are the features best related to the bone’s mechanical properties. Conducting ex-vivo experiments demonstrated that the velocity feature best delineates intact and demineralized bones. The typical velocity of an intact bone (3000 m/s) is higher in comparison to a 72 h demineralized bone (1600 m/s). According to the receiver operating characteristic (ROC) curve, the optimal velocity cut-off value of 3096 m/s yields 80% sensitivity and 82.61% specificity between the intact and demineralized bones. Other features, such as the spectra of the demineralized bones’ acoustic response, exhibited higher attenuation for frequencies below 200 kHz in comparison to the intact bones. A time-frequency analysis demonstrated a frequency shift with demineralization. These results demonstrate the potential application of our proposed technique for monitoring bone demineralization.
Transition to turbulence in acoustically driven flows
Thompson, Charles , Chandra, Kavitha , Denis, Max , Mehta, Vineet

Journal of the Acoustical Society of America | May 1, 2015 | Volume: 137 | Issue: 4_Supplement | Pages: 2223-2223

10.1121/1.4920098 Get It

Direct numerical solutions of the three-dimensional time-dependent Navier-Stokes equation are presented for the evolution of three-dimensional finite-amplitude disturbances in the Stokes boundary layer. The basic flow is driven harmonically in time and the disturbances represent a departure from the basic state of the fluid. For fixed value of the fluid viscosity, instability is shown to be a function of the amplitude of oscillation of the basic flow, excitation frequency, and the channel wall geometry. Special attention is given to pressure gradient and surface wave driven flows. Conditions for instability and transition are outlined.
Ultrasonic scattering from poroelastic materials using a mixed displacement-pressure formulation
Denis, Max , Nguon, Chrisna, Chandra, Kavitha , Thompson, Charles

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2289-2289

10.1121/1.4900280 Get It

In this work, a numerical technique suitable for evaluating the ultrasonic scattering from a three-dimensional poroelastic material is presented. Following Biot’s derivation of the macroscopic governing equations for a fluid saturated poroelastic material, the predicted two propagating wave equations are formulated in terms of displacement and pressure. Assuming that porosity variations on a microscopic scale have a cumulative effect in generating a scattered field, the scattering attenuation coefficient of a Biot medium can be determined. The scattered fields of the wave equations are numerically evaluated as Neumann series solutions of the Kirchhoff-Helmholtz integral equation. A Padé approximant technique is employed to extrapolate beyond the Neumann series’ radius of convergence (weak scattering regime). In the case of bovine trabecular bone, the relationship between the scattering attenuation coefficient and the structural and mechanical properties of the trabecular bone is of particular interest. The results demonstrate the validity of the linear frequency-dependent assumption of attenuation coefficient n the low frequency range. Further comparisons, between measured observations and the numerical results will be discussed.
Difference frequency scattered waves from nonlinear interactions of a solid sphere
Nguon, Chrisna, Denis, Max , Chandra, Kavitha , Thompson, Charles

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2256-2256

10.1121/1.4900146 Get It

In this work, the generation of difference frequency waves arising from the interaction of dual-incident beams on a solid sphere is considered. The high-frequency incident beams induce a radiation force onto the fluid-saturated sphere causing the scatterer to vibrate. An analysis on the contribution between the difference frequency sound and radiation force pressure is of particular interest. The scattered pressure due to the two primary waves are obtained as solutions to the Kirchhoff–Helmholtz integral equation for the fluid–solid boundary. Due to the contrasting material properties between the host fluid and solid sphere, high-order approximations are used to evaluate the integral equation.
Differentiation of benign and malignant breast lesions using Comb-Push Ultrasound Shear Elastography
Denis, Max , Mehmohammadi, Mohammad, Meixner, Duane D. , Fazzio, Robert T. , Chen, Shigao , Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2159-2159

10.1121/1.4899813 Get It

In this work, the results from our Comb Push Ultrasound Shear Elastography (CUSE) assessment of suspicious breast lesions are presented. The elasticity value of the breast lesions are correlated to histopathological findings to evaluate their diagnostic value in differentiating between malignant and benign breast lesions. A total of 44 patients diagnosed with suspicious breast lesions were evaluated using CUSE prior to biopsy. All patient study procedures were conducted according to the protocol approved by Mayo Clinic Institutional Review Board (IRB). Our cohort consisted of 27 malignant and 17 benign breast lesions. The results indicate an increase in shear wave velocity in both benign and malignant lesions compared to normal breast tissue. Furthermore, the Young’s modulus is significantly higher in malignant lesions. An optimal cut-off value of the Young’s modulus ≥ 80 kPa was observed for the receiver operating characteristic (ROC) curve. This is concordant with the published cut-off values of elasticity for suspicious breast lesions. [This work is supported in part by the grant 3R01CA148994-04S1 and 5R01CA148994-04 from NIH.]