Clinical results of ultrasound bladder vibrometry for assessment of bladder compliance
Cheong, Mathew , Denis, Max , Gregory, Adriana , Nenadic, Ivan , Husmann, Douglas A. , Mynderse, Lance A. , Bayat, Mahdi , Kumar, Viksit , Mehrmohammadi, Mohammad , Alizad, Azra , Fatemi, Mostafa

Journal of the Acoustical Society of America | May 6, 2016 | Volume: 139 | Issue: 4_Supplement | Pages: 2176-2176

10.1121/1.4950464 Get It

Healthy human bladder is a viscoelastic shell capable of expanding to allow storage of urine at low pressures. The ability to maintain low pressures as the urine volume increases is called bladder compliance. Compliance is a key in proper functioning of urinary system. Spinal cord injuries and other neurogenic diseases can cause deterioration in bladder expansion capability (e.g., through excessive growth of fibrotic tissue), which in turn can increase the rigidity of the wall and reduce bladder compliance. Urodynamic study (UDS) is the clinical standard for evaluation of the bladder compliance through observation of bladder pressure-volume behavior. However, this method is costly and invasive. Ultrasound bladder vibrometry (UBV) has been introduced as noninvasive technique for evaluation of bladder viscoelasticity through excitation of the bladder using ultrasound radiation force and tracking the resulting Lamb waves. Here, we present the results of UBV from 44 patients undergoing concurrent UDS and UBV studies. Our results show that elasticity parameters obtained from the UBV closely correlate with the UDS pressure-volume data with a median Pearson’s correlation value of more than 0.8. These results prove the potential utility of UBV as an alternative noninvasive method for bladder compliance assessment. [Work supported by NIH grant DK99231.]
Ultrasound bladder vibrometry for evaluation of bladder compliance: Preliminary in vivo results
Nenadic, Ivan , Greenleaf, James F. , Husmann, Douglas A. , Mynderse, Lance A. , Mehrmohammadi, Mohammad , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4011-4011

10.1121/1.4830635 Get It

Bladder compliance is defined as bladder’s ability to expand in volume without a significant change in pressure. The bladder wall is a multi-layered structure including a muscular layer and fibrous connective tissue. As the percent of connective tissue in the bladder interstitium increases compared to smooth muscle, the bladder becomes more rigid and less capable of expanding during filling. Currently, urodynamic studies (UDS) are considered as the clinical gold standard for bladder compliance assessment. This procedure is invasive and is associated with patient discomfort and is expensive. Ultrasound bladder vibrometry (UBV) is a novel acoustic-radiation-forced-based method for noninvasive assessment of bladder compliance. In UBV, an impulsive acoustic radiation force is focused on the bladder wall (under B-mode ultrasound image guidance) to induce vibrations which may be modeled by as a Lamb wave. High frame rate ultrasound is then utilized to detect the induced waves. This wave motion is then used to estimate the viscoelastic properties and the compliance of the bladder wall. Our results reveal a remarkable agreement between UBV and UDS cystometry measures, suggesting the potential of UBV as a viable clinical tool for the assessment of bladder compliance.
Application of shear wave imaging and shear wave dispersion ultrasound vibrometry in assessing viscoelastic properties of human thyroid: In vivo pilot study
Amador, Carolina , Urban, Matthew W. , Callstrom, Matthew R. , Greenleaf, James F. , Mehrmohammadi, Mohammad , Song, Pengfei , Morris, John C. , Chen, Shigao , Fatemi, Mostafa , Alizad, Azra , Urban, Matthew W

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4009-4009

10.1121/1.4830625 Get It

Thyroid cancer is the fastest growing age and gender adjusted cancer in 2011 according the American Cancer Society. The majority of the clinically diagnosed thyroid nodules are benign while less than 5% represent intrathyroidal cancers. Currently, the clinical gold-standard procedure for assessing the thyroid nodules is needle biopsy, a procedure that is associated with significant financial burden as well as pain and risk for patients. Therefore, a noninvasive, affordable, and potentially widely available method to differentiate between benign and malignant thyroid nodules can play an important role in reducing the number of unnecessary biopsies. In this study, we investigate the feasibility of two acoustic radiation force elastography techniques, shear wave dispersion ultrasound vibrometry (SDUV) and comb-push ultrasound shear wave elastography (CUSE imaging), in identifying thyroid nodules (imaging) and differentiating between benign and malignant pathologies based on their elasticity and viscosity (SDUV measurements). Our preliminary results show that the measured shear elasticity and shear viscosity parameters depend on tissue type; hence, these measurements may be utilized to differentiate between healthy normal thyroid tissue, benign nodules, and malignant nodules. Further studies on a large population of patients is required to better evaluate the role of the combination of elasticity and viscosity properties of tissue in differentiating various thyroid nodules.