Back to Authors

Kinnick, Randall R.

Mayo Clinic

Mayo Clinic

Citations 30

Quantifying nonlinear elasticity modulus of tissue-like solids using acoustic radiation force
Panahandeh-Shahraki, Danial, Kinnick, Randall R., Ghavami, Siavash , Guzina, Bojan B. , Kumar, Viksit , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

The Journal of the Acoustical Society of America | April 17, 2018 | Volume: 143 | Issue: 3_Supplement | Pages: 1802-1802

10.1121/1.5035900 Get It

As shown in a recent study, estimation of the magnitude of the acoustic radiation force (ARF) in isotropic tissue-like solids is the key to measuring a third-order nonlinear modulus of elasticity (C)—responsible for coupling the shear and volumetric constitutive responses of a material. Due to experimental limitations, a direct measurement of the ARF in tissue is however difficult. To overcome this problem, we deploy 3D elastodynamic finite element (EFE) simulations of the ARF experiment in tissue-mimicking phantoms to estimate (i) the “background” shear modulus from the phase of the induced shear waves; (ii) the ARF magnitude from the shear wave amplitude, and (iii) the modulus C from the knowledge of the ARF. In this way, by interpreting the ARF-generated shear waves through the prism of 3D-EFE simulations, we facilitate local estimation of the nonlinear C modulus with spatial resolution equaling the size of the focal region. We call this method the C-Elastography (CE). In this study, the CE technique is applied to gelatin phantoms containing an agar-based inclusion. The profiles of the C-modulus in phantoms tested demonstrate good correlation with the phantom geometry, showing marked (and sharp) C-contrast at push points acting on the inclusion. [Acknowledgment: NIH-Grant EB23113.]
An Interposed Pad in Open‐Chest Echocardiographic Porcine Scans for Mimicking Ultrasound Signal Attenuation in a Human Chest
Kinnick, Randall R., Katayama, Minako , Bëlohlávek, Marek

Journal of Ultrasound in Medicine | August 4, 2017 | Volume: 37 | Issue: 2 | Pages: 501-509

10.1002/jum.14351 Get It

Opening a chest in an experimental echocardiographic animal study eliminates ultrasound signal attenuation by the chest wall. We developed a scanning technique that involves the use of an attenuative pad created from a mixture of urethane and titanium dioxide. The pad was interposed within transmission gel between the transducer face and cardiac surface in open‐chest scans in a porcine model. Comparative measurements of left ventricular echogenicity without and with the pad demonstrate that the pad reproducibly causes ultrasound signal attenuation that closely mimics chest attenuation in clinical transthoracic echocardiographic studies.
Generation and measurement of shear waves in micellar fluids using ultrasound-based methods
Amador, Carolina , Otilio, Bruno L., Kinnick, Randall R., Urban, Matthew W.

The Journal of the Acoustical Society of America | June 10, 2017 | Volume: 141 | Issue: 5_Supplement | Pages: 3887-3887

10.1121/1.4988714 Get It

Wormlike micellar fluids are viscoelastic and their mechanical properties have been evaluated with mechanically generated shear waves combined with optical detection as well as rheological testing. In this work, we describe the use of acoustic radiation force and ultrafast ultrasound imaging to generate shear waves and measure their propagation, respectively. This shear wave elastography (SWE) method has been used to measure the viscoelastic mechanical properties in tissue-mimicking phantoms and soft tissues. We tested micellar fluids made from cetrimonium bromide (CTAB) and sodium salicylate (NaSAL) with a 5:3 ratio with different concentrations (100, 200, 300, and 400 mM). We fit an extended Maxwell model to the rheological test data (0.001-15.91Hz) and used the model parameters to calculate the shear wave phase velocity in the range of the SWE data (100-500 Hz). The phase velocities calculated from the rheology testing compared well with the SWE results. The mean absolute error was less than 0.02 m/s for all the micellar fluids tested. The SWE method is nondestructive and can be used for characterization of the viscoelasticity of micellar fluids, which could be used as a model for biological tissues. [This work was supported in part by grant R01DK092255.]
Ultrasonic method to characterize shear wave propagation in micellar fluids
Amador, Carolina , Otilio, Bruno L., Kinnick, Randall R., Urban, Matthew W.

The Journal of the Acoustical Society of America | October 21, 2016 | Volume: 140 | Issue: 3 | Pages: 1719-1726

10.1121/1.4962531 Get It

Viscoelastic micellar fluid characteristics have been measured with mechanically generated shear waves and showed good agreement to shear oscillatory methods. In this paper, shear waves in wormlike micellar fluids using ultrasound were successfully generated and detected. Micellar fluids of different concentrations (100, 200, 300, and 400 mM) were studied with ultrasound-based and conventional rheology methods. The measured micellar fluid complex modulus from oscillatory shear tests between 0.001 and 15.91 Hz was characterized with an extended Maxwell fluid model. The elastic and viscous parameters found using rheological testing were used to estimate shear wave phase velocity over a frequency range from 100 to 500 Hz, and compared to shear wave velocity measured with ultrasound-based methods with a mean absolute error 0.02 m/s. The shear wave frequency content was studied and an increase in shear wave center frequency was found as a function of micellar fluid concentration. Moreover, the bias found in the shear wave group velocity with respect to rheological measurement is attributed to the micellar fluid viscous component. Finally, the shear wave phase velocity evaluated at the center frequency agreed well with the rheological measurements.
Automated Compression Device for Viscoelasticity Imaging
Nabavizadeh, Alireza , Kinnick, Randall R., Bayat, Mahdi , Amador, Carolina , Fatemi, Mostafa , Urban, Matthew W. , Alizad, Azra , Fatemi, Mostafa

IEEE Transactions on Biomedical Engineering | September 22, 2016 | Volume: 64 | Issue: 7 | Pages: 1535-1546

10.1109/tbme.2016.2612541 Get It

Characterization of anisotropic media with shear waves
Aristizabal, Sara , Qiang, Bo, Amador, Carolina , Kinnick, Randall R., Greenleaf, James F. , Urban, Matthew W. , Brigham, John C. , Zhang, Xiaoming

The Journal of the Acoustical Society of America | October 18, 2014 | Volume: 136 | Issue: 4_Supplement | Pages: 2124-2124

10.1121/1.4899649 Get It

In conventional shear wave elastography materials are assumed to be linear, elastic, homogeneous, and isotropic. These assumptions are important to account for in certain tissues because they are not always appropriate. Many tissues such as skeletal muscle, the kidney, and the myocardium are anisotropic. Shear waves can be used to investigate the directionally dependent mechanical properties of anisotropic media. To study these tissues in a systematic way and to account for the effects of the anisotropic architecture, laboratory-based phantoms are desirable. We will report on several phantom-based approaches for studying shear wave anisotropy, assuming that these materials are transversely isotropic. Phantoms with embedded fibers were used to mimic anisotropic tissues. Homogeneous phantoms were compressed to induce transverse isotropy according to the acoustoelastic phenomenon, which is related to nonlinear behavior of the materials. The fractional anisotropy of these phantoms was quantified to compare with measurements made in soft tissues. In addition, soft tissues are also viscoelastic, and we have developed a method to model viscoelastic transversely isotropic materials with the finite element method (FEM). The viscoelastic property estimation from phantom experiments and FEM simulations will also be discussed.
Robust shear wave motion tracking using ultrasound harmonic imaging
Zhao, Heng , Manduca, Armando, Kinnick, Randall R., Greenleaf, James F. , Song, Pengfei , Urban, Matthew W. , Pislaru, Sorin V. , Chen, Shigao

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4010-4010

10.1121/1.4830628 Get It

Robust shear-wave motion detection is essential for producing reliable shear elasticity measurements for ultrasound shear-wave elastography (SWE). However, because shear-wave motion is extracted from radiofrequency signals which can be heavily contaminated by noise, shear-wave motion detection can be very challenging, especially for in vivo applications. This study investigated the implementation of harmonic imaging (HI) to facilitate more robust shear-wave tracking based on HI’s effectiveness in suppressing imaging noise associated with ultrasound reverberation, phase aberration, and clutter noise. A HI shear-wave tracking sequence was developed combining the pulse-inversion HI method with the plane wave imaging technique to transmit phase-inverted pulses at a high frame rate of several kilohertz. The backscattered ultrasound signals from phase-inverted pulses were added to suppress the fundamental and enhance the second harmonic component, from which the shear-wave motion was extracted. A pork belly phantom experiment showed that HI could significantly improve shear-wave motion detection by producing almost three-fold less underestimation of shear-wave motion and over ten-fold more precision for shear-wave speed measurements than fundamental imaging. An in vivo transthoracic case study of a human heart showed that HI substantially improved the success rate of shear-wave motion detection and could provide consistent estimates of the left ventricle myocardium stiffness.
Ultrasound-based shear wave evaluation in transverse isotropic tissue mimicking phantoms
Aristizabal, Sara , Kinnick, Randall R., Amador, Carolina , Nenadic, Ivan , Greenleaf, James F. , Urban, Matthew W. , Urban, Matthew W

The Journal of the Acoustical Society of America | November 1, 2013 | Volume: 134 | Issue: 5_Supplement | Pages: 4010-4010

10.1121/1.4830626 Get It

Introduction: Ultrasound radiation force-based methods can quantitatively evaluate tissue viscoelastic material properties. A limitation of current methods includes neglecting the inherent anisotropy nature of tissue. To explore this phenomenon, we created a phantom incorporating fibrous material that has preferential orientations. Methods: Two phantoms were made in a cube-shaped mold using a fibrous material arranged in multiple layers and embedded in porcine gelatin using two different concentrations of the gelatin (8%, 14%). Shear wave measurements were made in the phantoms at different angles by rotating the phantom, where 0° and 180° were defined along the fibers, and 90° and 270° across the fibers. Measurements were performed using a Verasonics ultrasound system equipped with a linear array transducer. Results/Discussion: The mean shear wave speeds and mean standard deviations for 8% and 14% gelatin along the fibers (0°) were (3.60 ± 0.03 and 4.10 ± 0.11 m/s) and across the fibers (90°) were (3.18 ± 0.12 and 3.90 ± 0.02 m/s), respectively. Conclusion: The fibrous gelatin-based phantoms exhibited anisotropy that could be measured using quantitative shear waves speed measurements. Increasing the gelatin percentage increases the shear wave speed and anisotropic moduli. [This study was supported by NIH grant DK092255.]
Spectral characteristics of breast vibro-acoustography images
Whaley, Dana H. , Urban, Matthew W. , Kinnick, Randall R., Greenleaf, James F. , Alizad, Azra , Fatemi, Mostafa , Urban, Matthew W

The Journal of the Acoustical Society of America | October 31, 2013 | Volume: 120 | Issue: 5_Supplement | Pages: 3269-3269

10.1121/1.4776997 Get It

Vibro-acoustography image is a function of the dynamic characteristics of the object at the vibration (difference) frequency (df). The dynamic characteristic of tissue is closely related to pathology. Therefore, it is important to evaluate image features versus df. Here, the influence of df on breast vibro-acoustography images is studied by scanning human breast at various df values ranging from 20 to 90 kHz. The subjects were chosen from a group of volunteers with different breast abnormalities. Images were compared subjectively to study image features and the appearances of breast lesions versus df. It is demonstrated that having a collection of images of the same tissue at different df values generally provides a better perception of the tissue structure and improves lesion identification. In most cases, higher df resulted in a higher signal-to-noise ratio and thus a higher image quality. Finally, a frequency-compounded images was obtained by calculating the weighted sum of images at different df values. It is demonstrated that image compounding normally improves visualization of breast tissue and abnormalities. [Work supported by NIH Grant EB-00535 and Grant BCTR0504550 from the Susan G. Komen Breast Cancer Foundation. Disclosure: Parts of the techniques used here are patented by MF and JFG.]
A noninvasive resonant mode imaging
Zhang, Xiaoming , Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

The Journal of the Acoustical Society of America | October 25, 2013 | Volume: 121 | Issue: 5_Supplement | Pages: 3110-3110

10.1121/1.4782046 Get It

The mechanical response of tissues to external forces has gained considerable interest in medical diagnosis. One approach of imaging the tissue elastic properties is to apply an external force on the surface of the body. Another approach is to generate a localized force inside the tissue with the radiation force of ultrasound. In this paper, a noninvasive method for imaging the vibration mode of an object is investigated. The radiation force of ultrasound is used to scan the object at a resonant frequency of the object. The vibration of the object is measured by laser and the resulting acoustic emission from the object is measured by a hydrophone. Experimental studies are carried out on a mechanical heart valve and arterial phantoms. The mode images on the valve are made by the hydrophone measurement and confirmed by FEM simulations. Compared with conventional B-scan imaging on arterial phantoms, the mode imaging can show not only the interface of the artery and the gelatin, but also the vibration modes of the artery. The images taken on the phantom surface suggest that an image of an interior artery can be made by vibration measurements on the surface of the body.