Citations

Mayo Clinic

Clear

87 citation(s) found for "Z, Justin Lee".

Impact of obesity on catheter ablation of ventricular tachycardia: In‐hospital and 30‐day outcomes
Tan, Min Choon , Yeo, Yong Hao , Ang, Qi Xuan , Tan, Jian Liang , Lee, Justin Z. , Rattanawong, Pattara , Yeo, Yong Hao , Tan, Min C , Tan, Bryan E‐Xin , Rattanawong, Pattara

Journal of Arrhythmia | July 5, 2023 | Volume: 39 | Issue: 4 | Pages: 672-675

10.1002/joa3.12892 | PMID 37560290 Get It

AbstractBackgroundEvidence on the impact of obesity on catheter ablation for ventricular tachycardia (VT) is scarce.Method and ResultsWe queried the Nationwide Readmissions Database to determine the hospital outcomes and procedural complications of VT ablation among the obese and nonobese populations. Obesity was associated with a more prolonged length of stay (p < .01), higher cost of hospitalization (p < .01), and higher rates of pericardial effusion or hemopericardium (p = .05) and vascular complications (p = .05). There was no significant difference in early mortality, 30‐day readmissions, and other procedural complications.ConclusionVT ablation could be performed relatively safely among patients with obesity.
Abstract 9696: Long-Term Outcomes With Abandoning versus Extracting Sterile Leads: A 10-Year Population-Based Study
Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Asirvatham, Samuel J. , Kusumoto, Fred , Lee, Justin

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.9696 Get It

Background: Long-term outcomes of lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) during cardiac implantable electronic devices (CIED) procedures requiring lead addition or replacement remain unclear. Hypothesis: We hypothesized that there is no difference in long-term (10-year) outcomes of LA versus TLE during CIED procedures requiring lead addition. Methods: We performed a retrospective cohort study of a population residing in seven adjacent counties of southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE for sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10-years or until their death were included. Outcomes were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system. Results: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. In long-term follow-up, indications for subsequent lead extraction arose in 9.1% (n=14) of patients with initial LA and 5.3% (n=1) in patients with initial TLE, after an average of 7-years. Moreover, out of 14 patients, who required secondary extraction in the LA cohort, 28.6% did not proceed with the extraction. Of the remaining 10 patients, 60% had clinical success and 40% had a clinical failure with the extraction. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges such as requiring balloon venoplasty or serial dilation (5.2% vs. 5.3%, P=1.0). There was no difference in 10-year survival probability among LA group and TLE group (P=0.64). Conclusion: Indications for subsequent extraction arose in 9.1% of patients with the initial LA approach for sterile leads after an average of 7.3 years and 28.6% did not proceed with the extraction. Of the patients who underwent the subsequent extraction, 60% had clinical success and 40% had a clinical failure. There was no difference in 10-year survival probability between patients with the initial LA approach or TLE approach.
Abstract 11583: Impact of Micra Pacemaker Implantation on Echocardiographic Parameters: A Multi-Center Analysis
Sriramoju, Anil, Elbanna, Mostafa , Seri, Amith Reddy , Fahmy, Mostafa Mahmoud , KoKo, Nway, Sriramoju, Anil , Baqal, Omar J , Ashraf, Hasan, Lee, Justin , Masry, Hicham El

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.11583 Get It

Introduction: Studies on leadless pacemakers (LP) are very limited and they often fail to reflect real population outcomes. Hypothesis: We sought to evaluate the effect of leadless pacemaker implantation on the echocardiographic parameters including ventricular function and valvular competence. Methods: A retrospective review including 162 patients (81 Micra Leadless pacemaker implant and 81 dual-chamber transvenous pacemakers) from 3 centers were included. Follow-up clinical, echocardiographic, and pacing characteristics were obtained over a median of 14+/-2 months. Results: baseline demographics and clinical characteristics were comparable between the 2 groups including age (78.6+/-9.9, Range 35-95) and gender (49 males, 69.5%). Compared to conventional pacemakers, LP patients had worsening tricuspid regurgitation noted on follow-up echo in 59.3% of patients compared to baseline(P<0.001). This difference was independent of the RV pacing percentage and device location. In addition, LP implantation resulted in a reduction of RV function (P=0.003) and left ventricular ejection fraction (P=0.03). The RV Pacing burden in LP patient patients was not associated with a change in LVEF during the follow-up period (95% CI -0.24, 0.20, p = 0.846). Conclusions: LP therapy is associated with worsening tricuspid valve regurgitation and biventricular dysfunction over a mean 1 year of follow-up. Additional prospective randomized studies are warranted to further evaluate these findings.
Abstract 10913: Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Deshmukh, Abhishek , Scott, Luis, Cha, Yong‐Mei , Mulpuru, Siva K. , Lee, Justin Z. , Tan, Min Choon , Rattanawong, Pattara , Srivathsan, Komandoor , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A.

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10913 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. Objective: This study sought to determine the causes of early mortality (≤90-days) after AF ablation and to further understand the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6,723 patients were included in the study. The 30-day and 90-day all-cause mortality rates were 0.09% and 0.22%, respectively. Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06%. Most of the early deaths (93.3%) occurred after discharge from index hospitalization, among which 64.3% were readmitted before their death, 14% died at home, and 7% were discharged on comfort care and died in hospice. The main reason for readmission leading to death was respiratory failure (33%). Conclusion: Atrial fibrillation ablation procedure has a 90-day mortality of 0.22% and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was 0.06%.
Abstract 10571: Causes of Early Mortality After Catheter Ablation of Ventricular Tachycardia in Patients With Reduced Left Ventricular Ejection Fraction
Lee, Justin Z. , Deshmukh, Abhishek , Shen, Win K., Scott, Luis R. , Cha, Yong‐Mei , Mulpuru, Siva K. , Tan, Min Choon , Srivathsan, Komandoor , Masry, Hicham El , Asirvatham, Samuel J. , McLeod, Christopher J.

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10571 Get It

Background: Recognition of the causes of early mortality after ventricular tachycardia (VT) ablation in patients with reduced left ventricular ejection fraction is an essential step toward improving post-procedural outcomes. Objective: This study sought to determine the causes of early mortality (≤30-days) after VT ablation in patients with reduced left ventricular ejection fraction and to understand further the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of all patients undergoing VT ablation in patients with reduced left ventricular ejection fraction from January 1, 2013, to November 10, 2021, at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record within the Mayo Clinic system and outside records. Results: A total of 503 patients (mean age 63 ± 13 years, 11.2% female) with EF <50% were included in the study. The 30-day all-cause mortality rate was 5% (n=25), and the mortality rate due to a procedural complication was 0.4%. Among all 30-day deaths, recurrent VT was the most common primary cause of death (44%). This was followed by decompensated heart failure (28%), procedure-related death (8%), cerebrovascular accident (CVA) (4%), and infection (4%). Most patients (91%) who died from VT had the VT recurrence within three days of the ablation. 76% of patients with early mortality had delayed referral for VT ablation, and 72% opted for comfort care before death. Conclusions: The overall early mortality (≤30-days) rate after catheter ablation of VT in patients with reduced left ventricular ejection fraction was 5%, but the death rate directly due to a procedural complication was only 0.4%. The most common cause of death was recurrent VT, followed by heart failure. Further research into ablation strategies is vital to improving the safety, efficacy, and durability of VT ablation.
Abstract 10567: Sepsis-Related Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10567 Get It

Background: Recognition of the infectious characteristics among the sepsis-related early mortality after transvenous lead removal (TLR) is an essential step to improving patient outcomes. Objective: This study sought to understand the infectious characteristic and circumstances among the sepsis-related early mortality after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Patient details were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 2,319 patients were included in the study. The overall 30-day sepsis-related mortality rate was 1.25% (n=29). Among the sepsis-related deaths, 24 patients (83%) had systemic cardiac implantable electronic device (CIED) infection, and 4 patients (14%) initially had isolated pocket infection. The average time from admission to TLR was 11 days. MSSA was the most common organism (n=8, 28%), and this was followed by MRSA (n=4, 14%) and Candida (n=3, 10%). Twenty of these patients (69%) had vegetation on the echocardiogram: vegetation on lead only in 9 patients, vegetation on both valve and lead in 8 patients, and vegetation on valve only in 3 patients. Among valvular vegetations, 5 patients had tricuspid valve vegetations, 3 patients had aortic valve vegetations, 2 patients had mitral valve vegetations, and 1 patient had both mitral and aortic valve vegetation. The average size of vegetation was 1.3±0.8 x 1.1±0.6 cm. Conclusions: The 30-day sepsis-related mortality rate was 1.25%. Among the sepsis-related early deaths, MSSA was the most common organism, and more than two-thirds (69%) of the patients had vegetations on cardiac imaging. This highlights the importance of further research to improve the infection outcome in TLR patients.
Abstract 10559: Causes of Early Mortality After Transvenous Lead Removal
Lee, Justin Z. , Deshmukh, Abhishek , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Friedman, Paul A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Kusumoto, Fred , Asirvatham, Samuel J.

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10559 Get It

Background: Recognition of the causes of early mortality after transvenous lead removal (TLR) is an essential step for the development of quality improvement programs. Objective: This study sought to determine the causes of early mortality after TLR and to further understand the circumstances surrounding death after TLR. Methods: We performed a retrospective analysis of all patients undergoing TLR from January 1, 2001, to January 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system and outside records when available. The causes of death were further characterized based on whether it was related to the TLR procedure. Results: A total of 2,319 patients were included in the study. The overall 30-day all-cause mortality rate was 3%. Among all 30-day deaths, infection was the most common primary cause of death (42%). This was followed by decompensated heart failure (17%), procedure-related death (10%), sudden cardiac arrest (7%), and respiratory failure (6%). The 30-day mortality rate directly due to complications associated with the TLR procedure was 0.3% due to vascular tear and cardiac perforation. A third of deaths (33%) occurred after discharge from index hospitalization, among which 43% were readmitted before their death, 35% died at home or a nursing facility, and 22% were discharged on comfort care and died in hospice. The main reasons for readmission prior to death were sepsis and decompensated heart failure. Conclusions: The majority (90%) of 30-day mortality after TLR was not due to complications associated with TLR procedures. The primary causes were infection and decompensated heart failure. This highlights the importance of further research to reduce postoperative mortality from these factors, including deaths after hospital discharge.
Heart failure is associated with increased risk of all‐cause mortality after transvenous lead extraction: A systematic review and meta‐analysis
Talaei, Fahimeh , Tan, Min Choon , Trongtorsak, Angkawipa , Lee, Justin Z. , Tan, Min C , Rattanawong, Pattara , Rattanawong, Pattara

Journal of Arrhythmia | June 8, 2023 | Volume: 39 | Issue: 4 | Pages: 596-606

10.1002/joa3.12880 | PMID 37560268 Get It

AbstractBackgroundTransvenous lead extraction (TLE) is increasingly considered in cardiac implantable electronic device management. Heart failure (HF) might be associated with mortality risks after the TLE procedure. This study aims to assess mortality risk in HF patients undergoing TLE.MethodWe searched MEDLINE and Embase databases from inception to June 2022 to identify articles that included patients with and without HF who underwent TLE, which reported mortality in both groups. The pooled effect size was calculated with a random‐effects model and 95% CI to compare post‐TLE mortality between the two groups.ResultsEleven studies were included in the analysis. Each left ventricular ejection fraction (LVEF) increased by 1% was associated with reduced mortality by 2% (HR = 0.98, 95% CI: 0.97–0.99, I2 = 74.9%, p < .01). The presence of HF compared to those without HF was associated with higher mortality rates (OR: 3.04, 95% CI: 2.56–3.61, I2 = 0.0%, p < .531). There was a significant increase in the mortality rates in patients with New York Heart Association (NYHA) function class III (OR: 2.29, 95% CI: 1.29–4.06, I2 = 0.0%, p = .498) and NYHA IV (OR: 8.5, 95% CI: 2.98–24.3, I2 = 0.0%, p = .997).ConclusionsOur study found that post‐TLE mortality decreases by 2% as LVEF increases by 1%, also mortality is higher in patients with NYHA III and IV.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Tan, Min Choon , Karikalan, Suganya Arunachalam , Deshmukh, Abhishek , Srivathsan, Komandoor , Scott, Luis R. , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A. , Mulpuru, Siva K. , Cha, Yong‐Mei , Munger, Thomas M. , Lee, Justin Z. , Karikalan, Suganya , Deshmukh, Abhishek J , Srivathsan, Komandoor , Scott, Luis R , McLeod, Christopher J , Asirvatham, Samuel J , Noseworthy, Peter A , Deshmukh, Abhishek J , Tan, Min C , Rattanawong, Pattara

Circulation: Arrhythmia and Electrophysiology | April 21, 2023 | Volume: 16 | Issue: 5 | Pages: No page available

10.1161/circep.122.011365 | PMID 37082954 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
Subcutaneous implantable cardioverter‐defibrillator noise following left ventricular assist device implantation
Khetarpal, Banveet Kaur , Javaid, Awad , Lee, Justin Z. , Mulpuru, Siva K. , Sorajja, Dan , Cha, Yong‐Mei , Mulpuru, Siva K , Kusumoto, Fred , Srivathsan, Komandoor

Journal of Arrhythmia | February 13, 2023 | Volume: 39 | Issue: 2 | Pages: 198-206

10.1002/joa3.12826 | PMID 37021015 Get It

AbstractBackgroundThe incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established.MethodsWe performed a retrospective study of patients implanted with LVAD and with a pre‐existing S‐ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida).ResultsOf the 908 LVAD patients, a pre‐existing S‐ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third‐generation EMBLEM MRI S‐ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD‐related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S‐ICD sensing vector, adjusting S‐ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S‐ICD device therapies to be turned off permanently.ConclusionsThe incidence of LVAD‐related S‐ICD noise is high in patients with concomitant LVAD and S‐ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S‐ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD‐SICD device interference and the need to improve S‐ICD detection algorithms to eliminate noise.