Citations

Mayo Clinic

Clear

2356 citation(s) found for "K, Long".

Long-term effects of 4 years of menopausal hormone therapy on white matter integrity
Faubion, Laura L. , Tosakulwong, Nirobul, Lesnick, Timothy G. , Fought, Angela J. , Kendall‐Thomas, June, Kapoor, Ekta , Fields, Julie A. , Bailey, Kent R. , James, Taryn T. , Løbo, Rogerio A. , Pal, Lubna , Hammers, Dustin B. , Cedars, Marcelle I. , Miller, Virginia M. , Harman, S. Mitchell , Gleason, Carey E. , Kantarci, Kejal , Kantarci, Kejal , Mak, Elijah , Kara, Firat , Tosakulwong, Nirobul, Reid, Robert I. , Schwarz, Christopher G. , Manson, JoAnn E. , Hammers, Dustin B , Brinton, Eliot A. , Malek‐Ahmadi, Michael , Naftolin, Frederick , Santoro, Nanette F. , Dowling, N. Maritza

Menopause | July 22, 2025 | Volume: 32 | Issue: 9 | Pages: 818-828

10.1097/gme.0000000000002562 | PMID 40694740 Get It

Objectives: To assess the long-term effects of 4 years of menopausal hormone therapy (mHT) on the brain’s white matter architecture in women who initiated mHT within 3 years of menopause onset. Methods: The Kronos Early Estrogen Prevention Study (KEEPS) was a multicenter, double-blind, randomized, placebo-controlled 4-year mHT trial with treatment arms of oral conjugated equine estrogens (oCEE), transdermal 17β-estradiol (tE2), and placebo in recently postmenopausal women. KEEPS Continuation was an observational follow-up of KEEPS participants. White matter integrity was evaluated in KEEPS Continuation participants 10 years after KEEPS completion using white matter hyperintensity volume, diffusion magnetic resonance imaging (dMRI) techniques, and cerebral infarcts. Linear regression models were fitted for each brain region to evaluate if there were differences in white matter between KEEPS treatment arms. Results: There was no evidence to suggest the long-term effects of 4 years of mHT on brain white matter in KEEPS Continuation participants [n=266, mean age 67 (58-73)]. No differences in dMRI metrics were found in each of the treatment arms (oCEE n=70; tE2 n=79) when compared to placebo (n=94), following a false discovery rate adjustment for multiple comparisons. There were no statistically significant differences in white matter hyperintensity volume or infarct occurrence when comparing each of the treatment arms to placebo. Conclusions: We found no evidence of the long-term effect of 4-year mHT on white matter integrity when compared to placebo, consistent with emerging evidence of the safety of short-term use of mHT in recently postmenopausal women.
Real‐world epilepsy monitoring with ultra‐long‐term subcutaneous electroencephalography: A 15‐month prospective study
Viana, Pedro F. , Biondi, Andrea , Winston, Joel S. , Freestone, Dean R. , Brinkmann, Benjamin H. , Richardson, Mark P. , Duun-Henriksen, Jonas , Biondi, Andrea , Winston, Joel S , Freestone, Dean R , Schulze-Bonhage, Andreas , Brinkmann, Benjamin H , Richardson, Mark P , Viana, Pedro F , Duun‐Henriksen, Jonas , Schulze‐Bonhage, Andreas

Epilepsia | July 19, 2025 | Volume: 66 | Issue: 11 | Pages: 4476-4489

10.1111/epi.18566 | PMID 40682766 Get It

Abstract Objective Novel subcutaneous electroencephalography (sqEEG) systems enable prolonged, near‐continuous cerebral monitoring in real‐world conditions. Nevertheless, the feasibility, acceptability and overall clinical utility of these systems remain unclear. We report on the longest observational study using ultra‐long‐term sqEEG to date. Methods We conducted a 15‐month prospective, observational study including 10 adult people with treatment‐resistant epilepsy. After device implantation, patients were asked to record sqEEG, to use an electronic seizure diary, and to complete acceptability and usability questionnaires. sqEEG seizures were annotated visually, aided by automated detection. Individualized temporal patterns of seizure occurrence were assessed via circadian circular statistics and via Fano factor analysis. Results Over a median duration of 438 days, 10 patients recorded a median 18.8 h/day, totaling 71 984 h of real‐world sqEEG data. Adherence and acceptability remained high throughout the study. Although 754 sqEEG seizures were recorded across patients, more than half (52%) of these were not reported in the patient diary. Of the 140 (27%) diary reports not associated with an identifiable sqEEG seizure, the majority (68%) were reported as seizures with preserved awareness. The sqEEG to diary F1 agreement score was highly variable, ranging from .06 to .97. Patient‐specific patterns of circadian seizure occurrence and seizure clustering were found, including several relevant discrepancies between sqEEG and diary. Significance We demonstrate feasibility and high acceptability of ultra‐long‐term (months–years) sqEEG monitoring. These systems help provide real‐world, more objective seizure counting compared to patient diaries. It is possible to objectively monitor individual temporal fluctuations of seizure occurrence.
Global Consensus Statement on the Management of Pregnancy in Inflammatory Bowel Disease
Mahadevan, Uma , Seow, Cynthia H. , Chaparro, María, Flanagan, Emma , Julsgaard, Mette , Kane, Sunanda V. , Watermeyer, Gillian , Fisher, Susan G. , Anderson, Phil, Duricova, Dana, Dubinsky, Marla C. , Long, Millie, IBD, Global Consensus Group for Pregnancy and, Barnes, Edward L, Chaparro, María, Kane, Sunanda, Ng, Siew, Fisher, Susan, Dubinsky, Marla, Long, Millie, Huang, Vivian , Julsgaard, Mette , Barnes, Edward L. , Chaparro, María, Friedman, Sonia , Ng, Siew C. , Torres, Joana , Yamamoto-Furusho, Jesus , Robinson, Christopher James , Fisher, Susan, Gearry, Richard B. , IBD, Global Consensus Group for Pregnancy and, Barnes, Edward L, Chaparro, María, Ng, Siew, Dubinsky, Marla, Long, Millie

Inflammatory Bowel Diseases | July 15, 2025 | Volume: 31 | Issue: 10 | Pages: 2615-2664

10.1093/ibd/izaf171 | PMID 40874613 Get It

Abstract Background & Aims Pregnancy can be a complex and risk-filled event for women with inflammatory bowel disease (IBD). High-quality studies in this population are lacking, with limited data on medications approved to treat IBD during pregnancy. For patients, limited knowledge surrounding pregnancy impacts pregnancy rates, medication adherence, and outcomes. Limited provider knowledge leads to highly varied practices in care affected by local dogma, available resources, individual interpretation of the literature, and fear of harming the fetus. The variations in guidelines by different societies and countries reflect this and lead to confusion for physicians and patients alike. The Global Consensus Consortium is a group of 39 IBD and content experts and 7 patient advocates from 6 continents who convened to review and assess current data and come to an agreement on best practices based on these data. Methods The GRADE (Grading of Recommendations Assessment, Development, and Evaluation) process was used when sufficient published data were available and the RAND (Research and Development) process in those instances where expert opinion was needed to guide consistent practice. Recommendations were informed by the guiding principle that maternal health best supports infant health. Results The topics were divided into ten categories with 34 GRADE recommendations and 35 consensus statements. Conclusions Overall, the goal of the group was to provide data-driven and practical guidance to improve the care of women with IBD around the globe based on the best available research.
Assessing Acute and Long‐Term Toxicities of Proton Radiation Therapy in Pediatric Pelvic Tumors: Findings From the Pediatric Proton Consortium Registry
Almohtasib, Jamil , Indelicato, Daniel J. , Paulino, Arnold C. , Mihalcik, Stephen A. , Ermoian, Ralph P. , Chang, J. , Kwok, Young , Perkins, Stephanie M., Hill‐Kayser, Christine E. , Zeina, Wael, Yock, Torunn I. , Gargollo, Patricio C. , Ermoian, Ralph , Chang, John Hah-Chih , Laack, Nadia N Issa , Yock, Torunn I , Paulino, Arnold C , Indelicato, Daniel J , Lee, Jae Young , Perentesis, John P. , Laack, Nadia N.

Pediatric Blood & Cancer | July 15, 2025 | Volume: 72 | Issue: 10 | Pages: No page available

10.1002/pbc.31811 | PMID 40660625 Get It

ABSTRACTIntroductionProton beam therapy (PT) offers a targeted approach to treating pediatric tumors by minimizing radiation exposure to surrounding healthy tissue. However, the specific toxicity profile associated with it remains underexplored. This study aims to investigate the incidence and risk factors of acute and late treatment‐related toxicities following PT in pediatric patients with pelvic tumors.MethodsUsing data from the Pediatric Proton Consortium Registry (PPCR), we analyzed 126 pediatric patients who underwent PT for pelvic tumors. We assessed the incidence of gastrointestinal (GI), genitourinary (GU), and musculoskeletal (MSK) toxicities at baseline, during treatment, and across follow‐up intervals.ResultsAcute toxicities were observed in 61.9% of patients posttreatment, with new GI, GU, and MSK toxicities occurring in 54.3%, 9.7%, and 7.0% of baseline toxicity‐free patients, respectively. Follow‐up indicated that 20.6%, 22.2%, and 13.5% of patients developed late GI, GU, and MSK toxicities, respectively. Use of passive scattering proton therapy and radiation to the abdomen were significant predictors of GI toxicity development, while higher radiation dose was associated with MSK toxicity development.ConclusionOur findings demonstrate the safety profile of PT among pediatric patients while identifying specific risk factors, such as passive scattering proton therapy and abdominal irradiation, that contribute to increased GI toxicity. While proton therapy appears to be a well‐tolerated treatment option, the observed toxicity rates highlight the need for continued monitoring and long‐term follow‐up.
Enhancing proton therapy quality assurance with custom‐designed Octopoint phantom and Gafchromic film
Tang, Xueyan , Beltran, Chris , Furutani, Keith M. , Gilson, Glen, Gustafson, Jon M., Herman, Michael , Johnson, J. , Kruse, Jon J. , Long, Kenneth M., Mundy, Daniel W. , Remmes, Nicholas B. , Tasson, A , Whitaker, Todd , Matysiak, Witold, Tryggestad, E., Matysiak, W , Gilson, Graham S, Gustafson, Jon, Ito, Shima, Johnson, Jed E , Tasson, Alexandria , Whitaker, Thomas J , Tryggestad, Erik J, Beltran, Chris J , Furutani, Keith M , Matysiak, Witold P , Ito, Shima , Long, Kenneth M.

Journal of Applied Clinical Medical Physics | July 14, 2025 | Volume: 26 | Issue: 7 | Pages: No page available

10.1002/acm2.70156 | PMID 40657664 Get It

Abstract Background Proton therapy offers precise tumor targeting while minimizing damage to surrounding healthy tissue, making it especially valuable for treating tumors near critical organs and in pediatric patients. However, its success depends on accurate beam delivery, requiring rigorous quality assurance (QA) to maintain treatment precision and effectiveness. Purpose This study aims to standardize the measurement of key aspects of proton therapy delivery, such as gantry and couch isocentricity, spot position accuracy, and spot size consistency. The goal is to enhance the delivery accuracy of proton therapy across various clinical settings, improving patient outcomes. Methods The QA framework uses the Octopoint phantom, Gafchromic film, and spot position monitor (SPM) log data to evaluate proton beam isocentricity, spot position, and spot size. The Octopoint phantom, made from acrylic, was used with Gafchromic films at various gantry and couch angles to measure isocentricity. MATLAB tools were used to analyze spot positions, and SPM logs provided verification. Sensitivity tests were conducted to assess the system's response to intentional shifts and errors, ensuring alignment with clinical QA standards. Results The Octopoint phantom's stepwise two‐dimensional (2D) fitting process, validated against film‐measured dose profiles, accurately identified beam and ball bearing (BB) centroid locations. Isocentricity tests conducted over 8 months across four gantries demonstrated consistent beam‐to‐BB radial offsets. The phantom showed excellent repeatability, with a maximum standard deviation of 0.1 mm across various couch‐gantry combinations. Sensitivity testing across all axes revealed a strong alignment between intended shifts and measured values. Over the course of a year, film measurements tracked spot position and size consistency, with deviations remaining within acceptable clinical limits. Comparisons with SPM data further confirmed the system's reliability in maintaining beam accuracy across different gantry angles and energy levels. Conclusions This study presents a reliable QA framework for ensuring precision in proton therapy delivery. By combining the Octopoint phantom, Gafchromic film analysis, and SPM log file evaluation, we effectively measured isocentricity, spot position accuracy, and spot size stability. The framework demonstrated adaptability across various clinical QA tasks, enhancing the accuracy and safety of proton therapy treatments.
Plasma Metabolomics, Lipidomics, and Acylcarnitines Are Associated With Vision and Genotype but Not With Dietary Intake in Long‐Chain 3‐Hydroxyacyl‐ CoA Dehydrogenase Deficiency (
Chung, H. , Gregor, Ashley, Sim, Elaine, Lau, Alison, Black, Danielle, Scanga, Hannah L. , Linshinski, Angela, Yang, Paul , Matern, Dietrich , Gillingham, Melanie B , Chung, Hak, Choi, Dongseok , Lau, Alison, Black, Danielle, Pennesi, Mark Edward , Sahel, José‐Alain , Nischal, Ken Kanwal , Everett, Lesley A , Vockley, Jerry , Harding, Cary O. , Gillingham, Melanie B.

Journal of Inherited Metabolic Disease | July 10, 2025 | Volume: 48 | Issue: 4 | Pages: No page available

10.1002/jimd.70060 | PMID 40635623 Get It

ABSTRACT 3‐hydroxy acylcarnitines (3‐OH‐ACs) are key biomarkers for screening of long‐chain 3‐hydroxyacyl‐CoA dehydrogenase and trifunctional protein deficiencies (LCHADD/TFPD). The utility of this biomarker for disease monitoring in identified patients remains debated, and recent suggestions have highlighted the potential use of lipidomics for diagnosis, monitoring, prognosis, and/or identification of new biomarkers. We evaluated the use of omics in LCHADD/TFPD patients by analyzing plasma acylcarnitine profiles, metabolomics, and lipidomics, combined with genotype, visual assessments, and dietary records. Fasting plasma from 39 participants with LCHADD/TFPD and 32 control subjects were analyzed through untargeted metabolomic and lipidomic analyses. In LCHADD/TFPD participants, acylcarnitine profiling, visual and retinal function assessments were performed, and 3‐day diet records were collected. Relationships between acylcarnitines, metabolomics, lipidomics, along with visual outcomes and dietary intake were investigated. Plasma of LCHADD/TFPD participants exhibited elevated 3‐OH‐ACs, which correlated with genotype and visual outcomes. Metabolomics successfully distinguished LCHADD/TFPD from controls, and the biggest divergence was observed in lipid pathways. Metabolomic profiles tightly correlated with 3‐OH‐ACs, genotype, and visual outcomes. Lower concentrations of total lipids and some individual lipid species such as phosphoethanolamines (PE) were detected in LCHADD/TFPD, except for elevations in several certain triglycerides. LCHADD/TFPD participants followed a diet low in long‐chain fat (LCFA) as recommended. LCFA intake did not correlate with either plasma 3‐OH‐ACs or metabolomics. 3‐OH‐ACs are strong consistent biomarkers of LCHADD/TFPD that are associated with clinical parameters of vision and genotype. We did not observe a relationship between dietary LCFA intake and 3‐OH‐ACs.
Multi‐Institutional Survey of 4‐Year Ultrasound Quality Control Findings
Long, Zaiyang , Russ, Megan , Larson, S, Holland, Mark, Lu, Zhengfeng , Kofler, Cameron , Chen, Jianfeng, Zagzebski, James A., Stickel, Jennifer R. , Dohatcu, Andreea, Stickel, Jennifer , Zhou, Wei , Li, Zhimin

Journal of Ultrasound in Medicine | July 3, 2025 | Volume: 44 | Issue: 11 | Pages: 2103-2111

10.1002/jum.16763 | PMID 40607767 Get It

Objectives Periodic quality control (QC) testing of ultrasound (US) imaging systems is essential to ensure and maintain image quality and safety. The study aims to analyze QC findings from medical physics annual surveys of modern clinical US systems in a multi‐institutional survey. Methods QC results from annual surveys between 2018 and 2021 were retrospectively collected from 12 medical physicists from 11 institutions or consulting companies (hereafter referred to as sites). QC tests were classified as scanner‐ and transducer‐related tests, where scanner‐related tests also included evaluation of diagnostic workstation display monitors and routine QC programs if applicable. Test methodology and pass/fail criteria were established by each site. QC findings were defined as results requiring follow‐up action by service engineers, vendors, or other personnel. The percentage of annual findings was calculated for each site and averaged across the years of data contributed. Furthermore, findings across all sites were aggregated for an overall analysis. Results QC data from a total of 1069 scanner tests and 4542 transducer tests were collected. The average annual percentage of scanner‐related findings varied from 0 to 40.8% among all sites (first quartile 8.7%, median 18.2%, and third quartile 34.1%), while that of transducer‐related findings ranged between 0.5% and 19.9% (first quartile 3.9%, median 7.2%, and third quartile 14.5%). For scanner‐related tests, the top 3 categories of findings were associated with physical and mechanical integrity (171 findings, 74.7%), quantitative testing of the scanner display monitor (40 findings, 17.5%), and scanner port creating artifacts (10 findings, 4.4%). The top 3 findings for transducers related to uniformity and artifact (227 findings, 79.9%), physical and mechanical integrity (44 findings, 15.5%), and sensitivity in fundamental mode (9 findings, 3.2%). Conclusions Medical physics annual surveys revealed considerable actionable findings of modern US systems, which inform the status of current US QC practices in the United States and may guide future standardization and recommendation of QC tests.
A Retrospective Study Identifying Factors Associated with Long-Term Survival in Lung Transplant Recipients: A Focus on Psychosocial Wellbeing and Social Determinants of Health
Huang, Eric , Saddoughi, Sahar A. , Yadav, Hemang , Pennington, Kelly M. , Kennedy, Cassie C.

Respiratory The American Medical Journal | July 2, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.33590/respiramj/fajf6685 Get It

Long-Term Autoimmune Polyarthritis due to COVID-19 Vaccine
Pallipamu, Namratha, Pandit, Trupiti, Pandit, Ramesh

HCA Healthcare Journal of Medicine | July 1, 2025 | Volume: 6 | Issue: 3 | Pages: No page available

10.36518/2689-0216.1619 | PMID 40642580 Get It

Background Vaccinations for COVID-19 have played a pivotal role in controlling the global pandemic, with most adverse events being mild and transient. However, rare post-vaccination autoimmune responses have been reported. The understanding of long-term rheumatologic sequelae, particularly autoimmune polyarthritis following COVID-19 vaccination, remains limited. Case Presentation We report the case of a 41-year-old previously healthy man who developed progressive polyarthritis and systemic symptoms following the Johnson & Johnson COVID-19 vaccine. The initial symptoms of joint swelling and arthralgia appeared within a week of the first vaccine dose, subsiding temporarily with medication. After receiving a booster dose, the patient experienced worsening polyarthritis affecting multiple joints including knees, elbows, wrists, shoulders, and neck, along with low-grade fever, fatigue, and functional decline. Despite outpatient anti-inflammatory therapy, symptoms persisted and worsened over the next six months, prompting hospitalization. Workup revealed elevated inflammatory markers (ESR 77 mm/hr, CRP 193.2 mg/L), synovial fluid consistent with inflammatory arthritis, and infectious serologies. Imaging showed joint effusions and calcified pulmonary granulomas. He was diagnosed with vaccine-induced reactive arthritis. Treatment with intravenous corticosteroids led to partial symptom relief, and he was discharged on oral steroids and initiated on methotrexate for long-term management. Conclusion Clinicians should maintain a high index of suspicion for autoimmune phenomena such as reactive polyarthritis following COVID-19 vaccination, especially in patients with new-onset joint symptoms. Early recognition and referral to rheumatology may improve outcomes. Further studies are needed to clarify the pathophysiology, risk factors, and long-term prognosis of such vaccine-associated autoimmune conditions.