Citations

Mayo Clinic

Clear

343 citation(s) found for "Asirvatham, Samuel J".

Telocytes express ANO‐1‐encoded chloride channels in canine ventricular myocardium
Pinilla, Pedro J Gomez, Beyder, Arthur, Farrugia, Gianrico , Asirvatham, Samuel J. , Gomez Pinilla, Pedro J, Kapa, Suraj , Asirvatham, Samuel J , DeSimone, Christopher V. , McLeod, Christopher J. , Kapa, Suraj

Journal of Arrhythmia | April 6, 2019 | Volume: 35 | Issue: 3 | Pages: 515-521

10.1002/joa3.12176 | PMID 31293701 Get It

AbstractIntroductionIt is unknown if ANO‐1 is expressed in the heart, though the presence of a calcium‐activated chloride current has been proposed to mediate some cardiac dysrhythmias. Furthermore, a specific cell type termed telocytes, morphologically mimicking Cajal cells which use ANO‐1 to modulate their pacemaker activity in the gut, have been described in the heart. We therefore sought to determine whether this channel is expressed in the canine heart.MethodsMyocardium was sampled from the ventricles of five canines. Sections were labeled with anti‐Kit and anti‐ANO‐1 antibodies. Slides were reviewed by four investigators looking at cell morphology, distribution, and co‐localization. Identification of telocytes was based on criteria including morphology, Kit positivity (+), and ANO‐1 positivity (+).ResultsClusters of cells meeting criteria for telocytes were seen in the epicardium, sub‐epicardium, and mid‐myocardium. A small subset of cells that were morphologically similar to myocytes was ANO‐1 (+) but Kit (−). In total, three different cell classes were found: (i) Kit (+), ANO‐1 (+) cells with the appearance of telocytes; (ii) Kit (+), ANO‐1 (−) cells; and (iii) Kit (−), ANO‐1 (+) cells with the morphologic appearance of cardiac myocytes.ConclusionsTelocytes are present in the canine ventricle and express ANO‐1. These data merit further study to elucidate the functional expression of these channels in the heart and whether they may be targets for cardiac arrhythmias.
Three-Dimensional Printed Biopatches With Conductive Ink Facilitate Cardiac Conduction When Applied to Disrupted Myocardium
Pedrotty, Dawn , Kuzmenko, Volodymyr , Sugrue, Alan , Livia, Christopher , Vaidya, Vaibhav R. , Asirvatham, Samuel J. , Gatenholm, Paul , Pedrotty, Dawn M, Sugrue, Alan M, Asirvatham, Samuel J , Livia, Christopher , Karabulut, Erdem , McLeod, Christopher J. , Kapa, Suraj

Circulation: Arrhythmia and Electrophysiology | March 8, 2019 | Volume: 12 | Issue: 3 | Pages: No page available

10.1161/circep.118.006920 | PMID 30845835 Get It

Background: Reentrant ventricular arrhythmias are a major cause of sudden death in patients with structural heart disease. Current treatments focus on electrically homogenizing regions of scar contributing to ventricular arrhythmia with ablation or altering conductive properties using antiarrhythmic drugs. The high conductivity of carbon nanotubes may allow restoration of conduction in regions where impaired electrical conduction results in functional abnormalities. We propose a new concept for arrhythmia treatment using a stretchable, flexible biopatch with conductive properties to attempt to restore conduction across regions in which activation is disrupted. Methods: Carbon nanotube patches composed of nanofibrillated cellulose/single-walled carbon nanotube ink 3-dimensionally printed in conductive patterns onto bacterial nanocellulose were developed and evaluated for conductivity, flexibility, and mechanical properties. The patches were applied on 6 canines to epicardium before and after surgical disruption. Electroanatomic mapping was performed on normal epicardium, then repeated over surgically disrupted epicardium, and then finally with the patch applied passively. Results: We developed a 3-dimensional printable carbon nanotube ink complexed on bacterial nanocellulose that was (1) expressable through 3-dimensional printer nozzles, (2) electrically conductive, (3) flexible, and (4) stretchable. Six canines underwent thoracotomy, and, during epicardial ventricular pacing, mapping was performed. We demonstrated disruption of conduction after surgical incision in all 6 canines based on activation mapping. The patch resulted in restored conduction based on mapping and assessment of conduction direction and velocities in all canines. Conclusions: We have demonstrated 3-dimensional custom-printed electrically conductive carbon nanotube patches can be surgically manipulated to improve cardiac conduction when passively applied to surgically disrupted epicardial myocardium in canines.
Real‐world experience with leadless cardiac pacing
Vaidya, Vaibhav R. , Dai, Mingyan , Asirvatham, Samuel J. , Rea, Robert F., Thome, Trena, Mulpuru, Siva K. , Venkatachalam, Kalpathi L., Ryan, J. , Friedman, Paul A. , Cha, Yong‐Mei , Thome, Trena M, Ryan, James D , Friedman, Paul A , Cha, Yong-Mei , Asirvatham, Samuel J , Srivathsan, Komandoor , Kusumoto, Fred

Pacing and Clinical Electrophysiology | January 11, 2019 | Volume: 42 | Issue: 3 | Pages: 366-373

10.1111/pace.13601 | PMID 30632622 Get It

AbstractBackgroundLeadless cardiac pacing (LCP) has emerged as a new modality for permanent pacing. We sought to describe comparative outcomes between LCP and transvenous pacemakers.MethodsPatients receiving LCP (Micra [Medtronic, Minneapolis, MN, USA] and Nanostim [St. Jude Medical/Abbott Laboratories, Chicago, IL, USA]) between 2014 and 2017 at the Mayo Clinic Heart Rhythm Enterprise practice (Rochester, MN, USA; Jacksonville, FL, USA; and Scottsdale, AZ, USA) were identified. We identified 1:1 age‐ and sex‐matched controls receiving single‐chamber transvenous ventricular pacemakers (TVP). Statistical analyses were performed with JMP 13.0.0 (SAS, Institute Cary, NC, USA).ResultsNinety patients underwent LCP implantation (73 Micra and 17 Nanostim) with a median follow‐up duration of 62 (interquartile range 28‐169) days. Both groups had 100% successful device implant rates. There were no differences in procedure‐related major (0% vs 1%) or minor complications (8% vs 3%) in the LCP versus TVP groups (P > 0.05). Excluding Nanostim patients, there was a lower rate of device‐related revision or extraction in the Micra versus TVP groups (0% vs 5%, P = 0.028). Device endocarditis was more common in the TVP group (0% vs 3%, P = 0.04). Estimated longevity was greater for the LCP group (median 12.0 vs 10.0 years, P < 0.0001). An increase in severity of tricuspid valve regurgitation (TR) by ≥2 grades occurred in none of the LCP patients, and in 19% of the TVP patients (P = 0.017).ConclusionThere are no significant differences in procedural complications among patients receiving LCP versus TVP. The Micra group had lower rates of device‐related revision/extraction compared to the TVP group. Patients with leadless pacemaker were less likely to develop endocarditis or worsening TR.
Pericardiotomy Enhances Left Ventricular Diastolic Reserve With Volume Loading in Humans
Borlaug, Barry A. , Pochettino, Alberto , Pedrotty, Dawn , Asirvatham, Samuel J. , Carter, Rickey E. , Mauermann, William J., Pedrotty, Dawn M, Abel, Martin D, Asirvatham, Samuel J , Borlaug, Barry A , Carter, Rickey E , Schaff, Hartzell V. , Abel, Martin

Circulation | January 7, 2019 | Volume: 138 | Issue: 20 | Pages: 2295-2297

10.1161/circulationaha.118.036006 | PMID 30571519 Get It

Percutaneous pericardial access for electrophysiological studies in patients with prior cardiac surgery: approach and understanding the risks
Killu, Ammar M. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Expert Review of Cardiovascular Therapy | December 30, 2018 | Volume: 17 | Issue: 2 | Pages: 143-150

10.1080/14779072.2019.1561276 | PMID 30596289 Get It

Elimination of Purkinje Fibers by Electroporation Reduces Ventricular Fibrillation Vulnerability
Livia, Christopher , Sugrue, Alan , Witt, Tyra A. , Polkinghorne, Murray , Maor, Elad , Behfar, Atta , Asirvatham, Samuel J. , Witt, Tyra, Polkinghorne, Murray D, Kapa, Suraj , Lehmann, Helge I, Behfar, Atta , Asirvatham, Samuel J , Livia, Christopher , Maor, Elad , Lehmann, H. Immo , DeSimone, Christopher V. , McLeod, Christopher J.

Journal of the American Heart Association | September 16, 2018 | Volume: 7 | Issue: 15 | Pages: No page available

10.1161/jaha.118.009070 | PMID 30371233 Get It

Background The Purkinje network appears to play a pivotal role in the triggering as well as maintenance of ventricular fibrillation. Irreversible electroporation ( IRE ) using direct current has shown promise as a nonthermal ablation modality in the heart, but its ability to target and ablate the Purkinje tissue is undefined. Our aim was to investigate the potential for selective ablation of Purkinje/fascicular fibers using IRE . Methods and Results In an ex vivo Langendorff model of canine heart (n=8), direct current was delivered in a unipolar manner at various dosages from 750 to 2500 V, in 10 pulses with a 90‐μs duration at a frequency of 1 Hz. The window of ventricular fibrillation vulnerability was assessed before and after delivery of electroporation energy using a shock on T‐wave method. IRE consistently eradicated all Purkinje potentials at voltages between 750 and 2500 V (minimum field strength of 250–833 V/cm). The ventricular electrogram amplitude was only minimally reduced by ablation: 0.6±2.3 mV ( P =0.03). In 4 hearts after IRE delivery, ventricular fibrillation could not be reinduced. At baseline, the lower limit of vulnerability to ventricular fibrillation was 1.8±0.4 J, and the upper limit of vulnerability was 19.5±3.0 J. The window of vulnerability was 17.8±2.9 J. Delivery of electroporation energy significantly reduced the window of vulnerability to 5.7±2.9 J ( P =0.0003), with a postablation lower limit of vulnerability=7.3±2.63 J, and the upper limit of vulnerability=18.8±5.2 J. Conclusions Our study highlights that Purkinje tissue can be ablated with IRE without any evidence of underlying myocardial damage.
5921Premature ventricular contraction-triggered ventricular fibrillation: an under-recognized mechanism of sudden cardiac arrest in the young
Giudicessi, John R. , Kappa, S, Cannon, Bryan C. , Ackerman, Michael J. , Noseworthy, Peter A. , McLeod, Christopher J. , Asirvatham, Samuel J.

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy566.5921 Get It

P3698Correlation of lead length with procedural safety outcomes of magnetic resonance imaging in patients with legacy pacemakers and defibrillators
Padmanabhan, Deepak , Naksuk, Niyada , Deshmukh, Abhishek , Mulpuru, Siva K. , Felmlee, Joel P. , Dalzell, Connie, Olson, Nora E., Jondal, Mary Lou, Watson, Robert E. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh , Kapa, Suraj , Asirvatham, Samuel J.

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy563.p3698 Get It