Citations

Mayo Clinic

Clear

248 citation(s) found for "O, Hodge David".

Healthcare Utilization by Glaucoma Patients in a Team Care Model
Damento, Gena M., Winkler, Nelson S., Hodge, David O. , Khanna, Sunil S., Khanna, Cheryl L.

Seminars in Ophthalmology | September 21, 2018 | Volume: 33 | Issue: 7-8 | Pages: 829-837

10.1080/08820538.2018.1514059 | PMID 30240281 Get It

Outcomes After Implantable Cardioverter-Defibrillator Generator Replacement for Primary Prevention of Sudden Cardiac Death
Madhavan, Malini , Waks, Jonathan W. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mehta, Ramila A. , Hodge, David O. , Higgins, Angela , Webster, Tracy L., Witt, Chance M. , Cha, Yong‐Mei , Higgins, Angela Y. , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 17, 2018 | Volume: 9 | Issue: 3 | Pages: No page available

10.1161/circep.115.003283 | PMID 26921377 Get It

Background— The effectiveness of implantable cardioverter-defibrillators (ICDs) for primary prevention of sudden death in patients with an ejection fraction (EF) ≤35% and clinical heart failure is well established. However, outcomes after replacement of the ICD generator in patients with recovery of EF to >35% and no previous therapies are not well characterized. Methods and Results— Between 2001 and 2011, generator replacement was performed at 2 tertiary medical centers in 253 patients (mean age, 68.3±12.7 years; 82% men) who had previously undergone ICD placement for primary prevention but subsequently never received appropriate ICD therapy. EF had recovered to >35% in 72 of 253 (28%) patients at generator replacement. During median (quartiles) follow-up of 3.3 (1.8–5.3) years after generator replacement, 68 of 253 (27%) experienced appropriate ICD therapy. Patients with EF ≤35% were more likely to experience ICD therapy compared with those with EF >35% (12% versus 5% per year; hazard ratio, 3.57; P =0.001). On multivariable analysis, low EF predicted appropriate ICD therapy after generator replacement (hazard ratio, 1.96 [1.35–2.87] per 10% decrement; P =0.001). Death occurred in 25% of patients 5 years after generator replacement. Mortality was similar in patients with EF ≤35% and >35% (7% versus 5% per year; hazard ratio, 1.10; P =0.68). Atrial fibrillation (3.24 [1.63–6.43]; P <0.001) and higher blood urea nitrogen (1.28 [1.14–1.45] per increase of 10 mg/dL; P <0.001) were associated with mortality. Conclusions— Although approximately one fourth of patients with a primary prevention ICD and no previous therapy have EF >35% at the time of generator replacement, these patients continue to be at significant risk for appropriate ICD therapy (5% per year). These data may inform decisions on ICD replacement.
Risk of Appropriate Therapy and Death Before Therapy After Implantable Cardioverter-Defibrillator Generator Replacement
Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Lushinsky, Emilie C., Mulholland, Megan B., Cha, Yong‐Mei , Madhavan, Malini , Noseworthy, Peter A. , Gersh, Bernard J.

Circulation: Arrhythmia and Electrophysiology | September 14, 2018 | Volume: 11 | Issue: 8 | Pages: No page available

10.1161/circep.117.006155 | PMID 30354311 Get It

Background The decision to initially implant an implantable cardioverter-defibrillator (ICD) is informed by robust randomized controlled trials, but no such data exist to guide the decision to replace an ICD generator. In this study, we aimed to determine outcomes after ICD generator replacement. Methods All patients with ischemic or nonischemic cardiomyopathy who underwent ICD generator replacement from 2001 to 2011 at Mayo Clinic, MN, or Beth Israel Deaconess Medical Center, MA, were included. Outcomes included (1) appropriate therapy after generator replacement and (2) death before appropriate therapy after generator replacement. Cox proportional hazards modeling was used to determine the associations between patient characteristics and outcomes. Results In 1421 patients undergoing ICD generator replacement (mean±SD age 69.6±12.1 years, 81% male), appropriate therapy occurred after replacement in 435 patients (30.6%) over a mean follow-up of 2.7±2.6 years. Associated factors included lower left ventricular ejection fraction and history of appropriate therapy before generator replacement. Death before appropriate ICD therapy occurred in 336 (23.7%) patients. Older age, lower left ventricular ejection fraction, and noncardiac comorbidities, including diabetes mellitus, chronic lung disease, peripheral vascular disease, lower hemoglobin, and lower glomerular filtration rate, were associated with greater risk of death before appropriate therapy. A progressive increase in mortality was observed with aggregation of these noncardiac comorbidities. Conclusions The decision to replace the ICD should take into consideration not only left ventricular ejection fraction and history of ventricular arrhythmias, but also comorbid illnesses that may impact the duration and the quality of life.
Baseline peripheral blood biomarkers associated with clinical outcome of advanced lung cancer in patients treated with anti-PD-1 antibody.
Soyano, Aixa , Dholaria, Bhagirathbhai , Diehl, Nancy N. , Hodge, David O. , Lou, Yanyan , Dholaria, Bhagirathbhai R , Soyano, Aixa , Marin‐Acevedo, Julian A.

Journal of Clinical Oncology | September 6, 2018 | Volume: 35 | Issue: 15_suppl | Pages: e20599-e20599

10.1200/jco.2017.35.15_suppl.e20599 Get It

e20599 Background: The anti-PD-1 antibodies nivolumab and pembrolizumab have demonstrated improved overall survival (OS) and progression free survival (PFS) in a subset of patients with metastatic or locally advanced lung cancer (LC). To date, no blood biomarkers have been identified to predict clinical outcome to anti-PD-1 agents. Methods: A retrospective analysis of 52 patients with advanced LC and treated with anti-PD-1 antibodies in a single institution was performed. White blood cell count (WBC), absolute neutrophil count (ANC), absolute lymphocyte count (ALC), absolute neutrophil to absolute lymphocyte count ratio (ANC/ALC), absolute eosinophil count (AEC), and platelet counts at baseline before start of anti-PD-1 antibody were assessed. Kaplan–Meier and Cox regression analysis were done. Results: 48 patients were treated with nivolumab (92.3%) and 4 patients with pembrolizumab (7.7%). Median follow up was 13.6 months and median OS was 26 months. Higher baseline ANC and ANC/ALC ratio significantly correlated with worse clinical outcomes. Patients with baseline ANC > 6060/mm3 had a significantly increased risk of death [hazard ratio (HR) = 2.46; 95% CI 1.12–5.42, P = 0.025] and of progression on anti-PD-1 antibody [HR = 2.41; 95% CI 1.25–4.64, P = 0.009] compared with patients with ANC ≤6060/mm3. Similarly, patients with baseline ANC/ALC ratio ≥ 4.59 had a significantly increased risk of death [HR = 2.41; 95% CI 1.11–5.24, P = 0.027] and of progression on anti-PD-1 antibody [HR = 2.08; 95% CI 1.10–3.95, P = 0.027] compared with patients with ANC/ALC < 4.59. One year survival rate in patients who had ANC < 3390/mm3, ANC 3390-6060/mm3 and ANC > 6060/mm3 were 86.5%, 76.9% and 48.1% respectively. Conclusions: Increased baseline ANC and ANC/ALC were associated with poor PFS and OS in LC patients treated with anti-PD-1 antibodies. Although these findings need to be validated in a large sample size, our data suggested that baseline ANC and ANC/ALC ratio might help the risk stratification and assist treatment strategies. The potential predictive value of peripheral blood biomarkers for clinical outcomes to anti-PD-1 antibody should be further investigated in a prospective study.
Survival trends among non‐small‐cell lung cancer patients over a decade: impact of initial therapy at academic centers
Lou, Yanyan , Dholaria, Bhagirathbhai , Soyano, Aixa , Hodge, David O. , Cochuyt, Jordan J., Thomas, Mathew , Johnson, Margaret M. , Patel, Neal M. , Miller, Robert C. , Adjei, Alex A. , Hodge, David, Cochuyt, Jordan, Manochakian, Rami , Ko, Stephen J. , Ailawadhi, Sikander , Thomas, Mathew , Dholaria, Bhagirathbhai R , Soyano, Aixa , Ailawadhi, Sikander

Cancer Medicine | September 2, 2018 | Volume: 7 | Issue: 10 | Pages: 4932-4942

10.1002/cam4.1749 | PMID 30175515 Get It

Abstract Background Treatment of non‐small‐cell lung cancer (NSCLC) has been rapidly advancing over the last decade. Academic centers are considered equipped with better expertise. NSCLC outcome trends in novel therapeutic era and impact of initial treatment at academic centers have not been reported. Methods The National Cancer Database (NCDB) was used to identify NSCLC incident cases from 2004 to 2013. Overall survival (OS) was plotted by year of diagnosis and type of initial treatment center, accounting for several factors available in NCDB. Results A total of 1 150 722 NSCLC patients were included and separated by initial treatment center type (academic: 31.5%; nonacademic: 68.5%). Median follow‐up and OS for all patients were 11.8 months (range: 0‐133.6 months) and 13.1 months (95% CI: 13.08‐13.17), respectively. Median OS improved significantly for those diagnosed in 2010‐2013 (14.8 months [95% CI: 14.7‐14.9]) as compared to 2004‐2009 (12.4 months [95% CI: 12.3‐12.5]) ( P < 0.001). Treatment at academic centers was associated with improved OS (multivariate HR for OS = 0.929 [95% CI: 0.92‐0.94], P < 0.0010). Four‐year OS for academic and nonacademic cohorts was 28.5%% and 22.1%, respectively ( P < 0.001), and the difference was more pronounced in stage I to III NSCLC. Conclusion In this largest analysis, thus far, NSCLC survival has improved over time, and type of initial treatment center significantly influences survival. Identifying and removing barriers to obtaining initial treatment of NSCLC at academic medical centers could improve OS.
P2925Outcomes of direct current cardioversion in adults with cardiac amyloidosis
El‐Am, Edward , Grogan, Martha , Ammash, Naser M., Melduni, Rowlens M. , Hodge, David O. , Lin, Grace , Dispenzieri, Angela , White, Richard D. , Noseworthy, Peter A. , Pislaru, Sorin V. , Nkomo, Vuyisile T.

European Heart Journal | August 30, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy565.p2925 Get It

Comparison of Brain Natriuretic Peptide Levels to Simultaneously Obtained Right Heart Hemodynamics in Stable Outpatients with Pulmonary Arterial Hypertension
Helgeson, Scott A. , Imam, J. Saadi , Moss, John E. , Hodge, David O. , Burger, Charles D. , Helgeson, Scott A , Burger, Charles

Diseases | May 3, 2018 | Volume: 6 | Issue: 2 | Pages: 33

10.3390/diseases6020033 | PMID 29723983 Get It

Pulmonary arterial hypertension (PAH) is a progressive disease that requires validated biomarkers of disease severity. While PAH is defined hemodynamically by right heart catheterization (RHC), brain natriuretic peptide (BNP) is recommended by guidelines to assess disease status. Retrospectively collected data in 138 group 1 PAH patients were examined for the correlation of BNP levels to simultaneously obtained right heart catheterization (RHC). Patients were mostly Caucasian women, with functional class III symptoms, mean BNP of 406 ± 443 pg/mL, and an average right atrial pressure (RAP) of 9.9 ± 5.7 mm Hg and mean pulmonary artery pressure (mPAP) of 47.3 ± 14.7 mm Hg. Significant correlation was demonstrated between BNP and RAP (p = 0.021) and mPAP (p = 0.003). Additional correlation was seen with right heart size on echocardiography: right atrial (RAE; p = 0.04) and right ventricular enlargement (p = 0.03). An increased BNP level was an independent predictor of mortality (p < 0.0001), along with RAP (p = 0.039) and RAE (p = 0.018). Simultaneous collection of BNP at the time of RHC confirmed the correlation of BNP with right heart hemodynamics. The current results reinforce the use of BNP level as a continuous variable to assess disease severity in group 1 PAH.
Efficacy and safety of rivaroxaban compared to enoxaparin in treatment of cancer‐associated venous thromboembolism
Simmons, Benjamin, Wysokiński, Waldemar E. , Saadiq, Rayya A. , Bott‐Kitslaar, Dalene , Casanegra, Ana I. , Lenz, Charles J., Daniels, Paul R. , Bjarnason, Haraldur , Vargas, Emily , Hodge, David O. , Loprinzi, Charles L. , Wysokinski, Waldemar , Casanegra, Ana, Lenz, Charles, Daniels, Paul, Hodge, David, Holton, Sara J, Loprinzi, Charles, McBane, Robert , Casanegra, Ana I , Henkin, Stanislav , Holton, Sara , Cerhan, James R. , McBane, Robert D. , Bjarnason, Haraldur

European Journal of Haematology | April 4, 2018 | Volume: 101 | Issue: 2 | Pages: 136-142

10.1111/ejh.13074 | PMID 29617053 Get It

AbstractBackgroundLow molecular weight heparin (LMWH) is the guideline‐endorsed treatment for cancer‐associated venous thromboembolism (cVTE). Study objectives were to compare the efficacy and safety of rivaroxaban and enoxaparin in cVTE.MethodsUsing a cohort study design, consecutive patients with cVTE (3/1/2013‐7/31/2016), enrolled in the Mayo Thrombophilia Clinic Direct Oral Anticoagulants Registry, were compared to contemporary cancer patients receiving enoxaparin. The cumulative incidence of venous thromboembolism (VTE) recurrence, major and clinically relevant non‐major bleeding, and survival were assessed at 3 and 12 months.ResultsNinety‐eight patients received rivaroxaban (51% female, mean age 63 ± 12 years) and 168 enoxaparin (34.5% female, mean age 62 ± 15 years). The most common cancers included gastrointestinal/pancreatic, genitourinary and hematologic cancers. More than half of patients had pulmonary emboli at presentation. More than half had metastases, and two‐thirds were receiving chemotherapy. At 3 months, there were no differences in VTE recurrence (rivaroxaban 1.0% vs enoxaparin 4.2%; P = .15), major bleeding (rivaroxaban 5.1% vs enoxaparin 3.6%; P = .55), or all‐cause mortality (rivaroxaban 4.1% vs enoxaparin 8.9%; P = .14). At 12 months, these outcomes did not differ by treatment strategy.ConclusionThe results of this “real‐world” experience with cVTE suggest that rivaroxaban may offer a safe and effective alternative to LMWH.
Feasibility, Safety, and Tolerance of Mesenchymal Stem Cell Therapy for Obstructive Chronic Lung Allograft Dysfunction
Keller, Cesar A., Gonwa, Thomas A., Hodge, David O. , Hei, Derek J. , Centanni, John M., Keller, Cesar Ariel , Gonwa, Thomas Arthur, Hodge, David Orel, Zubair, Abba Chedi, Zubair, Abba C.

Stem Cells Translational Medicine | January 11, 2018 | Volume: 7 | Issue: 2 | Pages: 161-167

10.1002/sctm.17-0198 | PMID 29322685 Get It

Abstract Feasibility, tolerance, and safety of intravenous infusions of allogeneic mesenchymal stem cell (MSC) therapy in lung transplant recipients with bronchiolitis obliterans syndrome (BOS) are not well established. MSCs were manufactured, cryopreserved, transported to our facility, thawed, and infused into nine recipients with moderate BOS (average drop in forced expiratory volume in 1 second was 56.8% ± 3.2% from post-transplant peak) who were refractory to standard therapy and not candidates for retransplant. Cells were viable and sterile prior to infusion. Patients received a single infusion of either 1 (n = 3), 2 (n = 3), or 4 (n = 3) million MSCs per kg. Patients were medically evaluated before; during; and at 24 hours, 1 week, and 1 month after infusion for evidence of infusion-related adverse events and tolerance of therapy. Vital signs, pulmonary function test results, Borg Dyspnea Index, and routine laboratory data were recorded. Vital signs and O2 saturation did not significantly change during or up to 2 hours after MSC infusion. There were no significant changes in gas exchange variables, pulmonary function test results, or laboratory values at 1, 7, and 30 days postinfusion compared with preinfusion values. Infusion of MSCs in patients with BOS was feasible, safe, and well tolerated and did not produce any significant adverse changes in clinical, functional, or laboratory variables during or up to 30 days after infusion. Manufacturing, transport, and administration of intravenous, allogeneic bone marrow-derived MSCs in doses from 1 to 4 million MSCs per kg is safe in lung transplant recipients with BOS.