Citations

Mayo Clinic

Showing 10 of 108403 citations.

Influence of Surgical Technique and Surgical Skill on Outcomes of Cleft Palate Repair
Kirschner, Richard E. , Temkit, M’hamed , Baylis, Adriane L. , Hardin-Jones, Mary , Pollard, Sarah Hatch , Chapman, Kathy , Gosain, Arun K. , Sitzman, Thomas J. , Chee-Williams, Jessica L. , Chapman, Kathy L.

Plastic & Reconstructive Surgery | September 8, 2025 | Volume: 157 | Issue: 4 | Pages: 551e-562e

10.1097/prs.0000000000012422 | PMID 40920490 Get It

Background: There remains significant uncertainty about the fistula rate following palate repair with the Furlow double opposing Z-plasty (Furlow DOZ) technique compared with a straight-line/mucosal incision with intravelar veloplasty (IVVP) technique. Moreover, the relative impact of technique and surgical skill on fistula incidence remains unclear. Methods: A prospective, observational study of cleft palate repair was conducted. Enrollment occurred at 18 U.S.-based cleft centers, including 64 cleft surgeons. The primary outcome was postoperative fistula. Results: Overall, 1219 participants underwent cleft palate repair, 1178 of whom presented for follow-up. Of these, 581 (49.3%) underwent palate repair with the Furlow DOZ technique, 483 (41.0%) with the straight-line/IVVP technique, and 114 (9.7%) with an alternative technique. The overall fistula incidence was 5.3% (62 of 1162 analyzed for fistula occurrence). The fistula incidence was significantly lower in the Furlow DOZ group (2.4% [14 of 564]) than in the straight-line/IVVP group (7.8% [37 of 427]), with a propensity score–weighted risk difference of 5.7% (95% CI, 1.6% to 9.9%; P = 0.007). The fistula incidence varied substantially among surgeons: the top quartile’s fistula rate was 0% (0 fistulas among 417 repairs), whereas the bottom quartile’s fistula rate was 18.9% (31 fistulas among 164 repairs). Conclusions: Fistula incidence following cleft palate repair was significantly lower when using the Furlow DOZ technique, compared with the straight-line/IVVP technique. The effect of surgical technique was smaller, however, than the variation observed between the top and bottom quartiles of surgeons. These findings suggest that changing surgical technique may lead to small changes in fistula incidence, but greater opportunities exist to improve outcomes by improving surgical skill.
Mid-Term Survival in Patients Awaiting Heart and Kidney Transplantation with Impella 5.5 Support
Desai, Smruti, Paghdar, Smit , Ruiz, Jose , Jang, Ji-Min, Malkani, Sharan , Yip, Daniel , Leoni, Juan , Nativí, Jose, Sareyyüpoğlu, Başar , Landolfo, Kevin, Patel, Parag, Goswami, Rohan M , Jang, Ji-Min, Leoni, Juan Carlos , Landolfo, Kevin , Pham, Si M. , Goswami, Rohan

ESC Heart Failure | September 8, 2025 | Volume: 12 | Issue: 6 | Pages: 4140-4149

10.1002/ehf2.15189 | PMID 40920548 Get It

Abstract Background Patients with end-stage heart failure and chronic kidney disease requiring dual-organ transplantation (DOT) face significant challenges in utilizing durable mechanical circulatory support due to the risks associated with renal replacement therapies (RRTs) and multi-organ failure. Given the limited options available for long-term support in this patient population, there remains a critical need for alternative strategies to optimize end-organ function and bridge patients safely to transplant. With prolonged waitlist times for DOT, we present our experience with the Impella 5.5 as temporary mechanical circulatory support, demonstrating its potential to provide hemodynamic stability and support as a bridge to transplantation (BTT) in this complex cohort. Methods A single-centre retrospective review was completed of all patients listed for single-organ transplantation or DOT between December 2019 and November 2022 at Mayo Clinic in Florida, supported by the Impella 5.5 intended as BTT. The focus of this analysis was patients requiring RRT or listed for heart/kidney transplantation. Data were extracted from the electronic health record at baseline and during their transplant episode of care after institutional review board approval as exempt status for retrospective data collection. Results A total of 41 patients were supported with Impella 5.5, intended as BTT. All patients underwent successful transplantation. We focus on the 10 patients with Impella support who underwent DOT. In the DOT group, the median age at transplantation was 63 years (59–66), with nine males and one female. The baseline median ejection fraction was 19% (15–22), with 50% Caucasian and 50% African American and an even split between ischaemic and non-ischaemic aetiology. Median body mass index was 30 kg/m2 (26–31), and 60% were in blood group O. The median time on the waitlist for DOT patients was 53 days (29–75). Perioperative management of DOT Impella patients demonstrated baseline haemodynamics of RA 11 mmHg (7–16), mean PA 36 mmHg (32–47), PCWP 29 mmHg (21–35), mixed venous saturation (SVO2%) 51 (46–61) and Fick CI 2.03 L/min/m2 (1.66–2.5). Post-Impella placement haemodynamics demonstrated significant improvements in RA pressure to 5 mmHg (4–8), P = 0.02, SVO2 to 70% (65–72), P = 0.002, and Fick CI to 5.5 (5.2–8), P = 0.03. The average duration of support was 44 days (range 10–94). The median glomerular filtration rate at baseline was 27 mmol/L (16–29). Twenty-four hour urine protein averaged 168 mg/24 h (range 87–328), with the 24 h creatinine clearance of 29 mg/24 h (range 24–35). Eight of the 10 patients required continuous or intermittent RRT before DOT. The median total duration of RRT (including Impella support) was 36 days (9–72). DOT recipients had a 1 year survival of 90%, with an average follow-up of 432 days. Conclusions Our findings demonstrate that prolonged use of the Impella 5.5 provides safe and effective haemodynamic support for patients with end-stage heart and kidney failure awaiting dual-organ transplantation. With a 1 year survival rate of 90%, our data suggest that Impella 5.5 can be a viable alternative to traditional support strategies, particularly in patients who are otherwise limited by RRTs. As dual-organ transplantation becomes more prevalent, the Impella 5.5 offers a promising bridge to transplant, improving both short-term and long-term outcomes in this complex patient population.
The Growing Promise of Elinzanetant for Treatment of Menopausal Symptoms—Sustained Relief Without Hormones
Mehta, Jaya , Millstine, Denise , Millstine, Denise M, Manson, JoAnn E.

JAMA Internal Medicine | September 8, 2025 | Volume: 185 | Issue: 11 | Pages: 1328

10.1001/jamainternmed.2025.4436 | PMID 40920369 Get It

Impact of Metabolically Healthy and Unhealthy Obesity on Outcomes of Sepsis Complicated by Septic Shock in Elderly Patients
Chilingarashvili, Giorgi , Pasnoor, Diksha Sanjana , Bajjuri, Shreya, Parekh, Ritika, Manjappachar, Nirmala, Gummadi, Jyotsna , Nanjundappa, Athmananda , Desai, Rupak , Desai, Rupak

Journal of Intensive Care Medicine | September 8, 2025 | Volume: 41 | Issue: 6 | Pages: 486-494

10.1177/08850666251372543 | PMID 40920206 Get It

Purpose: Obesity is a risk factor for sepsis complications in older adults. We assessed the impact of metabolically healthy obesity (MHO) and metabolically unhealthy obesity (MUHO) on outcomes in septic shock. Methods: We conducted a retrospective analysis using the National Inpatient Sample (2016-2020) to identify a cohort of 1,737,075 patients aged 65 years and older who were hospitalized with septic shock, as defined by ICD-10 diagnosis codes. Obese patients without hypertension, diabetes, or hyperlipidemia were classified as MHO; those with ≥1 risk factor as MUHO. Baseline demographics and hospital characteristics were compared using χ² and Mann–Whitney U tests. Multivariable logistic regression adjusted for age, sex, race, comorbidity index, and hospital factors estimated odds ratios (ORs) for respiratory failure, mechanical ventilation, in-hospital mortality, and cardiac arrest. Secondary endpoints included length of stay (LOS) and hospitalization cost. Results: Among 268 050 obese patients, 23 915 (1.4%) were classified as MHO and 244 135 (14.1%) as MUHO. Both phenotypes were more prevalent in females and least common among Asian patients. MHO prevalence was highest among Native Americans, while MUHO was most common among Hispanics in 2020. From 2016 to 2019, the prevalence of both phenotypes remained stable, with modest increases observed during the 2020 sepsis surge. Respiratory failure occurred most frequently in the MHO group (∼70%), followed by MUHO (∼65%) and non-obese patients (∼60%). After adjusting for confounders, both MHO and MUHO groups had higher odds of respiratory failure and mechanical ventilation compared to non-obese patients. In-hospital mortality increased across all groups in 2020; however, MUHO patients had lower adjusted mortality risk. Cardiac arrest rates remained unchanged, while length of stay and hospitalization costs were highest among MHO patients. Conclusions: MHO and MUHO both confer higher respiratory failure and ventilation risk; lower mortality in MUHO warrants further study. Clinical Implications Phenotypic obesity classification may improve sepsis risk stratification and inform metabolic-specific management.
Integrating AI-Based Biomarkers Into Diabetic Kidney Disease Care: Evidence From the KidneyIntelX Precision Program
Baloch, Muhammad Yasir, Thongprayoon, Charat , Cheungpasitporn, Wisit

Kidney News | September 8, 2025 | Volume: 17 | Issue: 9 | Pages: 20

10.62716/kn.001182025 Get It

Applying High-reliability Principles to Infusion Pump Safety: A Case Study at a Multisite Health System
West, Ann , Schueler, Nicole, Moody, Rachel, Andersen, Merissa T., Dinsmore, Jill S., Miller, David B. , Wickens, Charles D., Byom, Pauline M., Lehnertz, Andrea Y., Ramar, Kannan , West, Ann M, West, Ann M., Andersen, Merissa T.

Journal of Patient Safety | September 8, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/pts.0000000000001395 | PMID 40919878 Get It

Objectives: A framework of high-reliability principles was used to identify, investigate, and mitigate infusion pump safety concerns at a large, multisite health care system. We developed a systematic approach to address challenges associated with overinfusions, underinfusions, and the inability to clear upstream occlusion alarms. We identified 112,875 upstream occlusion events for 389,604 infusion starts (failure rate, 29%) within 6 months. Methods: Five high-reliability principles were applied to infusion pump management. Preoccupation with failure emphasized reporting safety concerns and performing appropriate clinical and bench tests. Deference to expertise prompted the development of a multidisciplinary team with internal and external partners. Sensitivity to operations prompted assessment of human factors design, with simulations and analysis of medication-specific factors (e.g., viscosity; infusion rates). Reluctance to simplify prompted assessment of tubing characteristics (e.g., concentricity; wall thickness) with micro–computed tomography and process development for removing faulty equipment. Practice of resilience ensured ongoing engagement and commitment to a culture of safety and patient advocacy. Results: The multidisciplinary oversight team prompted a national recall, removal of malfunctioning pumps, and development of system-wide training and mitigation protocols. Despite ongoing pump challenges, our team optimized internal patient safety systems and processes. The cause of these malfunctions remains under investigation, but serious patient harm has been prevented. Conclusions: Key strategies for enhancing patient safety were continuous vigilance, interdisciplinary collaboration, and embracing complexity in a large health care organization. Future directions involve deeply integrating these high-reliability principles across all aspects of health care delivery to continue improving safety and quality outcomes.
Detecting Diverse Seizure Types with Wrist-Worn Wearable Devices: A Comparison of Machine Learning Approaches
Faust, Louis , Cui, Jie, Knepper, Camille, Brinkmann, Benjamin H. , Nasseri, Mona , Brinkmann, Benjamin H , Cui, Jie , Worrell, Gregory A.

Sensors | September 8, 2025 | Volume: 25 | Issue: 17 | Pages: 5562

10.3390/s25175562 | PMID 40942991 Get It

Objective: To evaluate the feasibility and effectiveness of wrist-worn wearable devices combined with machine learning (ML) approaches for detecting a diverse array of seizure types beyond generalized tonic–clonic (GTC), including focal, generalized, and subclinical seizures. Materials and Methods: Twenty-eight patients undergoing inpatient video-EEG monitoring at Mayo Clinic were concurrently monitored using Empatica E4 wrist-worn devices. These devices captured accelerometry, blood volume pulse, electrodermal activity, skin temperature, and heart rate. Seizures were annotated by neurologists. The data were preprocessed to experiment with various segment lengths (10 s and 60 s) and multiple feature sets. Three ML strategies, XGBoost, deep learning models (LSTM, CNN, Transformer), and ROCKET, were evaluated using leave-one-patient-out cross-validation. Performance was assessed using area under the receiver operating characteristic curve (AUROC), seizure-wise recall (SW-Recall), and false alarms per hour (FA/h). Results: Detection performance varied by seizure type and model. GTC seizures were detected most reliably (AUROC = 0.86, SW-Recall = 0.81, FA/h = 3.03). Hyperkinetic and tonic seizures showed high SW-Recall but also high FA/h. Subclinical and aware-dyscognitive seizures exhibited the lowest SW-Recall and highest FA/h. MultiROCKET and XGBoost performed best overall, though no single model was optimal for all seizure types. Longer segments (60 s) generally reduced FA/h. Feature set effectiveness varied, with multi-biosignal sets improving performance across seizure types. Conclusions: Wrist-worn wearables combined with ML can extend seizure detection beyond GTC seizures, though performance remains limited for non-motor types. Optimizing model selection, feature sets, and segment lengths, and minimizing false alarms, are key to clinical utility and real-world adoption.
Introduction to the Physiology, Anatomy, and Biochemistry of Autonomic Medicine
Sturgill, Forrest , Shouman, Kamal , Sandroni, Paola , Shouman, Kamal , Sturgill, Forrest L.

Journal of Integrative Neuroscience | September 8, 2025 | Volume: 24 | Issue: 8 | Pages: No page available

10.31083/jin31369 | PMID 40919619 Get It

Autonomic medicine is a rapidly evolving field focused on understanding diseases and processes that affect the autonomic nervous system (ANS). The ANS regulates essential involuntary physiologic processes such as heart rate, blood pressure, and digestion. This review introduces the key anatomical structures, physiological mechanisms, and biochemical processes underlying autonomic function. The anatomy section focuses on the peripheral components of the ANS, including the sympathetic and parasympathetic divisions. The physiological section explores the process of homeostasis and the intricate feedback systems that maintain this balance within the body. Finally, the biochemistry of autonomic signaling, focusing on the neurotransmitters acetylcholine, norepinephrine, and epinephrine, and their receptors, is reviewed. Pertinent clinical points are highlighted throughout, emphasizing the importance of the basic science to the clinical world. This review aims to provide a comprehensive basic science foundation for clinicians and researchers exploring the field of autonomic medicine.
The Use of Plasma Exchange for Clozapine Intoxication: A Case Report
Peters, Bradley J. , Sullivan, Luz Y. , Lange, R., Jones, K. A. , Baqir, Misbah , Jones, Katie W, Lange, Rebecca L.

Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy | September 8, 2025 | Volume: 45 | Issue: 10 | Pages: 706-710

10.1002/phar.70057 | PMID 40916481 Get It

ABSTRACTWe describe a case of a 56‐year‐old male who developed severe, refractory hypotension after an intentional ingestion of clozapine and who became hemodynamically stable after one session of therapeutic plasma exchange (TPE). The patient, who presented after an ingestion of clozapine, was found to have altered mental status and hypotension in the emergency department. Escalating catecholamine vasoactive agents were necessary to maintain adequate hemodynamics. Angiotensin II was added and rapidly up titrated in efforts to maintain adequate blood pressure. Due to persistent hemodynamic instability despite four vasoactive agents, TPE was attempted to enhance the elimination of the highly protein bound medication. Within 2 h of completing TPE, the catecholamines and vasopressin were stopped, and angiotensin II dosing was significantly decreased. This is the first report of utilizing TPE as a method of enhanced elimination of a toxic clozapine ingestion resulting in severe hemodynamic compromise. Further study is necessary to determine if TPE should be incorporated into the care of patients experiencing clozapine toxicity.
Flap Complications Following Maxillectomy, Reconstructive Surgery, and Postoperative Proton Radiotherapy: A Cohort Study and Considerations for Risk Mitigation
Safavi, Amir H. , Yang, Fan , Wu, Yingzhi, Matros, Evan , Hespe, Geoffrey E. , Gelblum, Daphna Y. , Cohen, Marc A. , Shen, Brian, Sine, Kevin, Mah, Dennis , Lee, Nancy Y. , Gelblum, Daphna Y , Cohen, Marc A , Ganly, Ian , Hung, Tony K. W. , Wong, Richard J. , Han, Dong Soo

Head & Neck | September 8, 2025 | Volume: 48 | Issue: 2 | Pages: 407-415

10.1002/hed.70040 | PMID 40916977 Get It

ABSTRACT Background Flap complications following maxillectomy, reconstruction, and adjuvant proton beam therapy (PBT) for primary maxillary and sinonasal malignancies are not well described. Methods This retrospective cohort study included consecutive patients treated between 2016 and 2023 from a single‐institutional database. Results Thirteen patients were identified with a median follow‐up of 26 months. No immediate post‐operative complications occurred, with a median time between surgery and PBT of 61 days. Nine patients (69.2%) had high‐risk postoperative pathology and required 66+ Gy(RBE), including five (38.5%) with gross disease receiving 70 Gy(RBE). Flap necrosis and fistulization occurred in three patients (23.1%) following PBT (median time from PBT to complication, 112 days). Higher flap mean and minimum dose, flap volume receiving at least 66 Gy[RBE], and minimum dose to 50% flap volume were associated with complications. Conclusions Careful patient selection and planning strategies should be considered to mitigate flap complication risk following adjuvant PBT for high‐risk post‐operative pathology.