Back to Authors

Holmes, David R.

https://orcid.org/0000-0002-0037-0373

Mayo Clinic

Mayo Clinic

Citations 350

Three‐dimensional prototyping for procedural simulation of transcatheter mitral valve replacement in patients with mitral annular calcification
Sabbagh, Abdallah El , Eleid, Mackram F. , Matsumoto, Jane M., Anavekar, Nandan S., Al‐Hijji, Mohammed , Said, Sameh M. , Holmes, David R. , Rihal, Charanjit S. , Foley, Thomas A. , El Sabbagh, Abdallah , Al-Hijji, Mohammed A , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Catheterization and Cardiovascular Interventions | January 23, 2018 | Volume: 92 | Issue: 7 | Pages: No page available

10.1002/ccd.27488 Get It

AbstractIntroductionThree‐dimensional (3D) prototyping is a novel technology which can be used to plan and guide complex procedures such as transcatheter mitral valve replacement (TMVR).MethodsEight patients with severe mitral annular calcification (MAC) underwent TMVR. 3D digital models with digital balloon expandable valves were created from pre‐procedure CT scans using dedicated software. Five models were printed. These models were used to assess prosthesis sizing, anchoring, expansion, paravalvular gaps, left ventricular outflow tract (LVOT) obstruction, and other potential procedure pitfalls. Results of 3D prototyping were then compared to post procedural imaging to determine how closely the achieved procedural result mirrored the 3D modeled result.Results3D prototyping simulated LVOT obstruction in one patient who developed it and in another patient who underwent alcohol septal ablation prior to TMVR. Valve sizing correlated with actual placed valve size in six out of the eight patients and more than mild paravalvular leak (PVL) was simulated in two of the three patients who had it. Patients who had mismatch between their modeled valve size and post‐procedural imaging were the ones that had anterior leaflet resection which could have altered valve sizing and PVL simulation. 3D printed model of one of the latter patients allowed modification of anterior leaflet to simulate surgical resection and was able to estimate the size and location of the PVL after inserting a valve stent into the physical model.Conclusion3D prototyping in TMVR for severe MAC is feasible for simulating valve sizing, apposition, expansion, PVL, and LVOT obstruction.
The Heart-Brain Team—Towards Optimal Team-Based Coordinated Care
Graff‐Radford, Jonathan , Holmes, David R. , Alkhouli, Mohamad

JAMA Cardiology | January 17, 2018 | Volume: 3 | Issue: 3 | Pages: 187

10.1001/jamacardio.2017.5072 Get It

Mitral Valve Anatomic Predictors of Hemodynamic Success With Transcatheter Mitral Valve Repair
Thaden, Jeremy J. , Malouf, Joseph F., Pislaru, Sorin V. , Holmes, David R. , Reeder, Guy S., Rihal, Charanjit S. , Eleid, Mackram F. , Sabbah, Michael S. , Nkomo, Vuyisile T. , Rihal, Charanjit S.

Journal of the American Heart Association | January 13, 2018 | Volume: 7 | Issue: 2 | Pages: No page available

10.1161/jaha.117.007315 Get It

Background Mitral regurgitation is a heterogeneous disease. Determining which patients derive optimal outcomes from transcatheter edge‐to‐edge mitral valve repair (TMVR) remains challenging. We sought to determine whether baseline mitral valve anatomic characteristics are predictive of left atrial pressure (LAP) changes during TMVR with MitraClip. Methods and Results Consecutive patients with severe mitral regurgitation undergoing TMVR (n=112) underwent continuous intraprocedural LAP monitoring and retrospective echocardiographic analysis for specific mitral anatomic characteristics. Procedural success (optimal LAP reduction) was defined as ≥40% reduction in left atrial V‐wave pressure compared with baseline. Echocardiographic predictors of optimal LAP reduction and increased postprocedure mean diastolic gradient were evaluated. Mean age was 79±14 years, and 36 patients (32%) were women. Primary, mixed, and secondary mitral regurgitation were present in 78 patients (70%), 22 patients (20%), and 12 patients (10%), respectively. Baseline mean LAP and V‐wave were 22±6 and 38±13 mm Hg; after TMVR, these decreased to 19±5 and 27±10 mm Hg, respectively ( P <0.0001 for both). Independent predictors of optimal LAP reduction were the presence of a flail scallop, mitral regurgitation localized to a single scallop, and high‐quality 3‐dimensional echocardiographic imaging. Independent predictors of elevated postprocedure mean diastolic gradient were elevated preprocedure mean diastolic gradient, mitral annular calcification, and implantation of multiple clips. Conclusions Mitral valve pathoanatomic features, including a flail leaflet and single jet, are predictive of optimal LAP reduction with TMVR. High‐quality 3‐dimensional imaging may help select patients with the highest likelihood of optimal hemodynamic results with TMVR. These data expand current knowledge about patient selection for TMVR and deserve further study in larger cohorts.
Analysis of Brain SPECT Images Coregistered with MRI in Patients with Epilepsy: Comparison of Three Methods
Long, Zaiyang , Mullan, Brian P., Holmes, David R. , Brinkmann, Benjamin H. , O’Connor, Michael K. , Hanson, Dennis P. , Hunt, Christopher H. , O'Connor, Michael K, Brinkmann, Benjamin H

Journal of Neuroimaging | January 10, 2018 | Volume: 28 | Issue: 3 | Pages: 307-312

10.1111/jon.12496 Get It

ABSTRACT BACKGROUND AND PURPOSE SISCOM and STATISCOM were clinically proved to be effective for ictal/inter‐ictal single‐photon emission computed tomography (SPECT) analysis coregistered with magnetic resonance imaging (MRI) for seizure localization. Recently, a software package also became available for this analysis. This study aimed to investigate and compare the performance of these analysis methods for seizure localization. METHODS A total of 378 patients who underwent 99m Tc‐ethyl cysteinate dimer (ECD) SPECT scans were retrospectively reviewed and 28 remained after applying exclusion criteria. Their SPECT and MRI images were analyzed with SISCOM (with z ‐score of 1.5 and 2), STATISCOM, and MIMneuro, resulting in a total of 112 image data sets. Two experienced radiologists participated in the blind review process using a custom tool and they can mark up to two hyper‐ and/or hypoperfusion regions. Their review results were analyzed using the Jackknife Free Response Receiver‐Operating Characteristics (JAFROC) test and the JAFROC figure‐of‐merit (FoM) was reported for each method. The interobserver agreement was also assessed using Cohen's kappa test. RESULTS Based on the readers’ two choices, averaged FoM was 85.7%, 83.9%, 66.1%, and 51.8% for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. The average confidence rating was 2.5, 2.3, 1.6, and 1.1 for STATISCOM, MIMneuro, SISCOM ( z ‐score = 2), and SISCOM ( z ‐score = 1.5), respectively. For interobserver agreement, kappa was .742 for STATISCOM, .816 for MIMneuro, .517 for SISCOM ( z ‐score = 2), and .441 for SISCOM ( z ‐score = 1.5; all P < .001). CONCLUSION Our study demonstrated that STATISCOM showed the best performance for seizure localization, which was closely followed by MIMneuro. In addition, MIMneuro was not inferior to SISCOM with either z ‐score.
Clinical Impact of Diabetes Mellitus on Outcomes After Transcatheter Aortic Valve Replacement
Abramowitz, Yigal, Vemulapalli, Sreekanth , Chakravarty, Tarun , Li, Zhuokai , Holmes, David R. , Wang, Alice , Cheng, Wen , Forrester, James S. , Smalling, Richard W. , Thourani, Vinod H. , Mack, Michael J. , Leon, Martin B. , Makkar, Raj , Douglas, Pamela S. , Matsouaka, Roland A, Smalling, Richard, Thourani, Vinod, Mack, Michael, Leon, Martin, Makkar, Raj R., Douglas, Pamela S , Kapadia, Samir , Matsouaka, Roland

Circulation: Cardiovascular Interventions | November 14, 2017 | Volume: 10 | Issue: 11 | Pages: No page available

10.1161/circinterventions.117.005417 Get It

Background— Diabetes mellitus (DM) adversely affects morbidity and mortality for cardiovascular diseases and procedures. Data evaluating the outcomes of transcatheter aortic valve replacement (TAVR) in diabetic patients are limited by small sample size and contradictory results. We aimed to establish the magnitude of risk and the incremental influence of insulin dependency by examining short- and long-term adverse outcomes according to DM status and therapy in the world’s largest TAVR registry. Methods and Results— We analyzed data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. In-hospital mortality, 30-day mortality, and 1-year mortality after TAVR in patients with and without DM were evaluated using multivariate modeling. Among 47 643 patients treated with TAVR from November 2011 through September 2015 at 394 US hospitals, there were 17 849 (37.5%) patients with DM. Overall, 6600 of the diabetic patients were insulin treated (IT). Thirty-day mortality was 5.0% in patients with DM (6.1% in IT DM and 4.4% in non-IT DM; P <0.001) versus 5.9% in patients without DM ( P <0.001). Overall, 1-year mortality was 21.8% in patients with DM (24.8% in IT DM and 20.1% in non-IT DM; P <0.001) versus 21.2% in patients without DM ( P =0.274). In a multivariable model, DM was associated with increased 1-year mortality (hazard ratio, 1.30; 95% confidence interval, 1.13–1.49; P <0.001). Subgroup multivariable analysis showed stronger mortality association in IT diabetics (hazard ratio, 1.57; 95% confidence interval, 1.28–1.91; P <0.001) than in non-IT diabetics (hazard ratio, 1.17; 95% confidence interval, 1.00–1.38; P =0.052). Conclusions— Our data establish the magnitude of short- and long-term risk conferred by DM and the incremental risk conferred by insulin dependency in the performance of TAVR. Clinical Trial Registration— URL: https://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Peripheral Artery Disease and Transcatheter Aortic Valve Replacement Outcomes
Fanaroff, Alexander C. , Manandhar, Pratik , Holmes, David R. , Harrison, J. Kevin , Thourani, Vinod H. , Mack, Michael J. , Sherwood, Matthew W. , Vemulapalli, Sreekanth , Douglas, Pamela S. , Hughes, G Chad, Jones, W Schuyler, Douglas, Pamela S , Cohen, David Jonathan , Hughes, George Chad , Jones, W. Schuyler , Fanaroff, Alexander C

Circulation: Cardiovascular Interventions | October 17, 2017 | Volume: 10 | Issue: 10 | Pages: No page available

10.1161/circinterventions.117.005456 Get It

Background— Peripheral artery disease (PAD) is associated with increased cardiovascular mortality, and PAD risk factors overlap with those for aortic stenosis. The prevalence and outcomes associated with PAD in a population undergoing transcatheter aortic valve replacement (TAVR) are unknown. Methods and Results— Using the Society of Thoracic Surgeons/Transcatheter Valve Therapy Registry linked to Medicare claims data, we identified patients ≥65 years old undergoing TAVR from 2011 to 2015. We calculated hazard ratios for 1-year adverse outcomes, including mortality, readmission, and bleeding, for patients with PAD compared with those without, adjusting for baseline characteristics and postprocedure medications. Analyses were performed separately by access site (transfemoral and nontransfemoral). Of 19 660 patients undergoing transfemoral TAVR, 4810 (24.5%) had PAD; 3730 (47.9%) of 7780 patients undergoing nontransfemoral TAVR had PAD. In both groups, patients with PAD were significantly more likely to have coronary and carotid artery diseases. At 1-year follow-up, patients with PAD undergoing TAVR via transfemoral access had a higher incidence of death (16.8% versus 14.4%; adjusted hazard ratio, 1.14; P =0.01), readmission (45.5% versus 42.1%; hazard ratio, 1.11; P <0.001), and bleeding (23.1% versus 19.7%; hazard ratio, 1.18; P <0.001) compared with patients without PAD. Patients with PAD undergoing TAVR via nontransfemoral access did not have significantly higher rates of 1-year mortality or readmission compared with patients without PAD. Conclusions— PAD is common among patients undergoing commercial TAVR via transfemoral and nontransfemoral access. Among patients undergoing transfemoral TAVR, PAD is associated with a higher incidence of 1-year adverse outcomes compared with absence of PAD. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT01737528.
Transcatheter aortic valve replacement for stenotic bicuspid aortic valves: Systematic review and meta analyses of observational studies
Reddy, Gautam , Greason, Kevin L. , Yoon, Sung‐Han , Makkar, Raj , Holmes, David R. , Wang, Zhen , Nishimura, Rick A.

Catheterization and Cardiovascular Interventions | September 30, 2017 | Volume: 91 | Issue: 5 | Pages: 975-983

10.1002/ccd.27340 Get It

AbstractObjectiveThe aim of this study was to perform a systematic review and meta‐analyses of observational studies of transcatheter aortic valve replacement (TAVR) for bicuspid aortic valve stenosis (BcAV).BackgroundTAVR for BcAV stenosis has been associated with an increased incidence of paravalvular leaks, valve malposition, pacemaker placement and all‐cause mortality. The conclusions drawn have been limited by small sample sizes. The use of TAVR for BcAV stenosis remains controversial.MethodsWe searched multiple databases from the inception of the databases through September 30, 2016 for studies of TAVR for BcAV stenosis. We included all observational studies with more than one patient and at least 1 month of outcomes.ResultsWe analyzed 13 observational studies with 758 patients. Meta analyses showed device success rate of 95% [95% confidence interval (CI) 90.2% to 98.5%] and an early safety event in 16.9% [95% CI 12.2% to 22%]. At 30 days, moderate to severe paravalvular leak was seen in 12.2% [95% CI 3.1% to 24.8%] and new pacemaker implantation in 17.9% [95% CI 14.2% to 22%]. All‐cause mortality was 3.7% [95% CI 2.1% to 5.6%], which should be viewed in the context of an STS PROM of 5.0%.ConclusionsThis analysis suggests that TAVR for BcAV is not associated with excess mortality. The incidence of paravalvular leaks and pacemaker implant is increased compared to tricuspid aortic valve cohorts undergoing TAVR, and operators should weigh these potential complications against the clinical benefit provided by TAVR for BcAV patients at high risk for surgical valve replacement.
Building Blocks of Structural Intervention
Alkhouli, Mohamad , Maor, Elad , Panaich, Sidakpal , Alli, Oluseun , Coylewright, Megan , Reeder, Guy S., Sandhu, Gurpreet S. , Holmes, David R. , Malouf, Joseph F., Eleid, Mackram F. , Rihal, Charanjit S. , Raphael, Claire E. , Panaich, Sidakpal S, Nishimura, Rick, Malouf, Joseph, Cabalka, Allison, Panaich, Sidakpal S , Maor, Elad , Alkhouli, Mohamad , Nishimura, Rick A. , Cabalka, Allison K. , Rihal, Charanjit S.

Circulation: Cardiovascular Interventions | September 27, 2017 | Volume: 10 | Issue: 10 | Pages: No page available

10.1161/circinterventions.117.005686 Get It

Structural heart disease is a rapidly evolving field, and approaches to procedural training are not standardized. We describe a novel modular approach to procedural training that considers each procedure as a series of building blocks that may be taught and assessed separately. Ten key structural heart disease building blocks can be identified, which, when combined with the cognitive skills of structural intervention and device-specific training, allow appropriate planning and implementation of structural procedures. Structural procedures require careful navigation of the aorta, left atrium, and right heart, including detailed understanding of relational anatomy. Component blocks include large bore vascular access, navigation within the left atrium, occlusion, snaring, and 3-dimensional relational anatomy. These building blocks also provide the foundation for new procedures through innovative use of the skill sets and devices to approach new clinical problems. The addition of device-specific training may be provided via proctoring and industry support. Using this approach, competency in less common procedures may be achieved and maintained. We discuss each building block in detail, approaches specific to the structural heart disease patient, the need for cross-discipline training, and empirical recommendations for training using this approach. We postulate that this new paradigm may be the preferred approach for training and assessment of structural heart disease interventional skills.
Comparative outcomes of transcatheter aortic valve replacement in African American and Caucasian patients with severe aortic stenosis
Aljohani, Sami, Almustafa, Ahmad, Al‐Hijji, Mohammed , Ali, Oluseun O., Holmes, David R. , Alkhouli, Mohamad , Al-Hijji, Mohammed A , Alkhouli, Mohamad , Alqahtani, Fahad

Catheterization and Cardiovascular Interventions | September 23, 2017 | Volume: 91 | Issue: 5 | Pages: 932-937

10.1002/ccd.27257 Get It

AbstractBackgroundRacial disparities in cardiovascular care have been extensively investigated. The introduction of transcatheter aortic valve replacement (TAVR) revolutionized the treatment of aortic stenosis (AS) in the last decade. Whether a racial disparity in the utilization and outcome of TAVR exists is unknown.MethodsWe utilized the nationwide inpatient sample (NIS) to compare utilization rates, and in‐hospital outcomes of Caucasians and African American (AA) patients who underwent TAVR between August 2011 and December 2014.ResultsA total of 7,176 patients (6870 Caucasians, 95.7%) and (306 AAs, 4.3%) were included in this analysis. Among patients who underwent aortic valve replacement between 2011 and 2014, the rates of TAVR utilization increased from 0.32% to 7.6% in AAs and from 0.4% to 8.8% in Caucasians. In propensity‐matched cohorts of patients (n = 300 Caucasians and n = 300 AAs), in‐hospital mortality was similar (3.7% and 3.3%, respectively, P = 0.99). Also, rates of key complications including stroke, permanent pacemaker implantation (PPMI), vascular complications, acute kidney injury, new dialysis, blood transfusion, and tamponade were similar in both races. There was also no significant difference between Caucasians and AAs with regards to length of stay, cost of hospitalization, and intermediate care facility utilization.ConclusionsThere was no significant difference in the utilization rates, in‐hospital outcomes, and cost of TAVR between Caucasians and AA patients in contemporary US practice. Further comparative studies of surgical and TAVR in AAs and other racial minorities are warranted.
Sex Differences in the Utilization and Outcomes of Surgical Aortic Valve Replacement for Severe Aortic Stenosis
Chaker, Zakeih, Badhwar, Vinay , Aljohani, Sami, Zack, Chad, Holmes, David R. , Rihal, Charanjit S. , Alqahtani, Fahad , Rihal, Charanjit S. , Alkhouli, Mohamad

Journal of the American Heart Association | September 21, 2017 | Volume: 6 | Issue: 9 | Pages: No page available

10.1161/jaha.117.006370 Get It

Background Studies assessing the differential impact of sex on outcomes of aortic valve replacement ( AVR ) yielded conflicting results. We sought to investigate sex‐related differences in AVR utilization, patient risk profile, and in‐hospital outcomes using the Nationwide Inpatient Sample. Methods and Results In total, 166 809 patients (63% male and 37% female) who underwent AVR between 2003 and 2014 were identified, and 48.5% had a concomitant cardiac surgery procedure. Compared with men, women were older and had more nonatherosclerotic comorbid conditions including hypertension, diabetes mellitus, obstructive pulmonary disease, atrial fibrillation/flutter, and anemia but fewer incidences of coronary and peripheral arterial disease and prior sternotomies. In‐hospital mortality was significantly higher in women (5.6% versus 4%, P <0.001). Propensity matching was performed to assess the impact of sex on the outcomes of isolated AVR and yielded 28 237 matched pairs of male and female participants. In the propensity‐matched groups, in‐hospital mortality was higher in women (3.3% versus 2.9%, P <0.001). Along with vascular complications and blood transfusion (6% versus 5.6%, P =0.027 and 40.4% versus 33.9%, P <0.001, respectively). Rates of stroke, permanent pacemaker implantation, and acute kidney injury requiring dialysis were similar (2.4% versus 2.4%, P =0.99; 6% versus 6.3%, P =0.15; and 1.4% versus 1.3%, P =0.14, respectively). Length of stay median and interquartile range were both similar between groups (7±6 days). Rates of nonhome discharge were higher among women (27.9% versus 19.6%, P <0.001). Conclusions Women have worse in‐hospital mortality following AVR compared with men. Coupled with the accumulating evidence suggesting higher magnitude of benefit of transcatheter AVR over AVR in women, women should perhaps be offered transcatheter AVR over AVR at a lower threshold than men.