Objectives The ability to determine the severity of renal fibrosis, which is involved in most chronic kidney diseases, may be beneficial for monitoring disease progression and management. The aim of this study was to assess a new method involving gold nanoparticles conjugated to an anti-collagen-I antibody (Co-I-AuNPs) as a computed tomography (CT) imaging contrast for the evaluation of renal fibrosis in situ. Materials and Methods Gold nanoparticles conjugated to an anti-collagen-I antibody were prepared using gold chloride reduction with sodium citrate and coated with polyethylene glycol (PEG), and their size was determined by electron microscopy and nanoparticle tracking analysis. Anti-collagen-I antibody was then conjugated to PEG-SH/COOH on the AuNP surface. The success of antibody conjugation was tested in vitro using collagen-coated plate and mouse stenotic kidney sections and in vivo using micro-CT and multidetector CT imaging. Results Bare AuNPs were 18.7 ± 0.6 nm and PEG-coated AuNPs were 45.3 ± 0.1 nm in size. In vitro, Co-I-AuNPs specifically bound to both a collagen-coated plate and mouse fibrotic kidneys. Furthermore, the stenotic mouse kidney showed increased Co-I-AuNPs retention compared with the contralateral kidney (59.3 ± 5.1 vs 45.1 ± 1.7 HU, P = 0.05), which correlated with its collagen deposition. Micro-CT also detected gold signals in situ in the Co-I-AuNP-injected kidney, which colocalized with histological trichrome staining. Conclusion Gold nanoparticles conjugated to an anti-collagen-I antibody are able to visualize kidney fibrosis in vitro and in situ and may be useful for nondestructive quantification of tissue fibrosis.
Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon-counting detector computed tomography system
Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Lung nodule volume quantification and shape differentiation with an ultra-high resolution technique on a photon counting detector CT system