Back to Authors

Alkhouli, Mohamad

https://orcid.org/0000-0003-3847-0959

Mayo Clinic

Mayo Clinic

Citations 151

Predictors of Permanent Pacemaker Implantation Following Valve-In-Valve Transcatheter Aortic Valve Replacement
Quelal, Karol , Arya, Namrata , Sugrue, Alan , Cha, Yong‐Mei , Eleid, Mackram F. , Deshmukh, Abhishek , Quelal, Karol , Donisan, Teodora , Harmon, David , Alkhouli, Mohamad

No container title available | June 29, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.175117683.36581994/v1 Get It

Background Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) is increasingly used to treat structural valve degeneration. Permanent pacemaker implantation (PPI) following TAVR is associated with increased morbidity and mortality, yet predictors specific to ViV-TAVR remain poorly defined. Objective To identify clinical and procedural predictors of PPI in patients undergoing ViV-TAVR. Methods We conducted a retrospective observational study of consecutive ViV-TAVR cases at the Mayo Clinic from 2012 to 2022. Clinical, ECG, procedural data and fluoroscopic measurements were analyzed, and propensity score matching was used to adjust for confounding. Predictors of PPI were identified using multivariable logistic regression. Results Among 261 patients, 24 (9.2%) required PPI. Balloon-expandable valves were used in 66.7% and self-expanding valves in 33.3%. Predictors of PPI included pre-procedural bifascicular block (OR 12.15, 95% CI: 2.52–68.89, p=0.003), greater septal implantation depth (OR 1.29, 95% CI: 1.04–1.65, p=0.019), and post-procedural new left (OR 23.56, 95% CI: 4.91–48.52, p=0.0004) and right bundle branch blocks (OR 24.4, 95% CI: 3.82–30.51, p=0.001). Aortic regurgitation as the mechanism of prosthetic valve failure was associated with reduced PPI odds (OR 0.28, 95% CI: 0.10–0.76, p=0.014). Pacing requirement—defined as >90% ventricular pacing—increased from 25% at 3 months to 56.25% at 12 months. At a median follow-up of 962.5 days (IQR 481.5–1555.3), adjusted mortality was significantly higher in the PPI group (aOR 9.4, 95% CI: 1.9–60.4, p=0.028). Conclusion Bifascicular block, greater septal depth, and new bundle branch blocks predict PPI post-ViV-TAVR, while aortic regurgitation appears protective. Risk stratification and procedural planning are critical.
Comparison of Flow Dynamics After Left Atrial Appendage Occlusion With the Watchman FLX Versus Amulet Devices: Implications for Device‐Related Thrombosis
Bshennaty, Ahmad , Vogl, Brennan , Bavo, Alessandra , Ghazal‐Aswad, Karam, Kramer, Anders , Jia, Yuheng , Beule, Matthieu De , Nielsen‐Kudsk, Jens Erik , Saleh, Ghasaq, Bavo, Alessandra Maria , Sularz, Agata , Ghazal-Aswad, Karam, Jia, Yuheng , De Backer, Ole , Hatoum, Hoda , Kramer, Anders Dahl , Saleh, Ghasaq , Sularz, Agata , Backer, Ole De , Alkhouli, Mohamad , Hatoum, Hoda

Catheterization and Cardiovascular Interventions | June 25, 2025 | Volume: 106 | Issue: 4 | Pages: 2084-2092

10.1002/ccd.31710 Get It

ABSTRACT Background This study aims to assess how Watchman FLX (Boston Scientific) and Amplatzer Amulet (Abbott) devices for left atrial appendage occlusion (LAAO) impact the flow dynamics in the LA and the risk of device‐related thrombosis (DRT). Methods Flow simulations were carried out for 12 AF patients before and after undergoing LAAO. Six patients had Watchman FLX while the other six had Amulet devices, of which three in each group had DRT. The flow parameters investigated included the LA velocities, pressure, time averaged wall shear stress (TAWSS), oscillatory shear index (OSI), and relative residence time (RRT). Low TAWSS and high OSI and RRT are generally associated with flow stasis and thrombosis. Results LA flow dynamics differed significantly between the two groups. On average, after LAAO, the Amulet patients exhibited a 25% increase in TAWSS and 24% decrease in RRT while the Watchman FLX patients exhibited, on average, a 24% decrease in TAWSS and a 23% increase in RRT. Both populations experienced an increase in LA pressure (~10% for Amulet patients and 16% for Watchman FLX patients). Increased DRT volume seems to be correlated with low TAWSS and elevated RRT. Conclusion This preliminary study suggests that the Amulet device might be associated with improved LA flow dynamics and a potentially lower incidence of DRT compared with the Watchman. However, a larger clinical study is needed to confirm these findings.
Short‐Term, Mid‐Term, and Long‐Term Outcomes of Transcatheter Aortic Valve Replacement With Balloon‐Expandable Versus Self‐Expanding Valves: A Meta‐Analysis of Randomized Controlled Trials
Tavakoli, Kiarash , Mohammadi, Negin , Bahiraie, Pegah , Saeidi, Sahar , Shaker, Farhad , Moghadam, Arman Soltani , Namin, Sara Montazeri , Rahban, Habib , Pawar, Shubhadarshini , Soleimani, Hamidreza , Jenab, Yaser , Makkar, Raj, Gupta, Aakriti, Mohammadi, Negin Sadat Hosseini , Soleimani, Hamidreza , Hosseini, Kaveh , Tajdini, Masih , Ahmad, Yousif , Iskander, Fady , Alkhouli, Mohamad , Makkar, Raj , Gupta, Aakriti

Clinical Cardiology | April 19, 2025 | Volume: 48 | Issue: 4 | Pages: No page available

10.1002/clc.70134 Get It

ABSTRACTBackgroundComparisons of outcomes after transcatheter aortic valve replacement with balloon‐expandable (BEV) versus self‐expanding (SEV) valves are limited.HypothesisThis study aimed to compare clinical and hemodynamic outcomes of BEV and SEV at short‐term (30 days), midterm (1 year), and long‐term (> 1 year) endpoints.MethodsPubMed, Embase, Scopus, and Cochrane Library databases were searched until July 2024 for randomized controlled trials. Random‐effect model (DerSimonian–Laird method) was used to pool the risk ratios (RR), mean differences, and 95% confidence intervals (CI).ResultsA total of 10 studies comprising 4325 patients (2295 BEV, 2030 SEV) were included. In short‐term, cardiovascular (RR: 0.56, 95% CI: 0.36–0.87) and all‐cause mortality (RR: 0.54, 95% CI: 0.35–0.81) were lower in the BEV group. Risk of moderate to severe paravalvular leak (PVL) was lower among BEV patients in short‐term (RR: 0.28, 95% CI: 0.17–0.49) and long‐term (RR: 0.28, 95% CI: 0.1–0.79). A limited number of studies showed a greater risk of clinical valve thrombosis on BEV in midterm and long‐term. The need for permanent pacemaker implantation was lower in BEV at both short‐term (RR: 0.56, 95% CI: 0.37–0.87), and midterm (RR: 0.78, 95% CI: 0.64–0.94). The SEV group had a larger effective orifice area with lower mean transvalvular pressure gradient at all endpoints.ConclusionsBEV is associated with reduced risk of clinical outcomes in short‐term; however, most differences diminish in longer evaluations, except for moderate to severe PVL, which remains elevated for SEV. SEVs had better hemodynamic results and lower risk of clinical valve thrombosis.
Characterization of the Aortic Arch in Relation to Stroke after Transcatheter Aortic Valve Replacement
Vogl, Brennan , Vitale, Emily, Zahrt, Elise, Castriota, Fausto, Hatoum, Hoda , Hatoum, Hoda , Saleh, Ghasaq , Russo, Gerardo Lo , Sularz, Agata , Castriota, Fausto , Alkhouli, Mohamad

Journal of the Heart Valve Society | March 26, 2025 | Volume: 2 | Issue: 1 | Pages: 27-35

10.1177/30494826251325568 Get It

Background Stroke remains a concern after transcatheter aortic valve replacement (TAVR). Several studies attempted to identify correlates of stroke but there remains a need for better predictors. Objective This study aims to characterize the aortic arch to identify potential correlates of stroke after TAVR using a patient cohort that includes cases with and without stroke. Methods A retrospective analysis was performed on 52 patients who underwent TAVR at Mayo Clinic and Maria Cecilia Hospital. Of these patients, 26 had a stroke after TAVR and 26 did not (control). Anatomical characterization was performed on each patient. Patient-specific 3D digital models of the ascending aorta, aortic arch, and calcium were created for each patient. Geometrical measurements, including cross-sectional areas, volumes, tortuosity, curvature, and length of the model were recorded. Results There was no significant difference in the various area measurements between the two groups, but the aortic arch cross-sectional area ratio (cerebral ostia cross-sectional areas/arch cross-sectional area) was significantly higher in the stroke group. Additionally, there was no significant difference in tortuosity, curvature, aortic volume, and length of the aorta. Aortic valve calcium score, aorta calcium, and aortic arch type (I, II, or III) were not significantly different between the groups. The prevalence of a bovine arch (BA) configuration was significantly higher in the stroke group (46% vs 8% control, p < 0.05). Conclusion Aortic arch cross-sectional area ratio and BA variant were the most significant correlates of stroke after TAVR.
Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures
Alkhouli, Mohamad , Carroll, John D. , Desai, Aken , Gao, Yu‐Rong , Xiong, Tomnema, Natale, Andrea , Inglessis‐Azuaje, Ignacio , Knight, Bradley P. , Alkhouli, Mohamad , Desai, Aken A , Knight, Bradley P , Natale, Andrea , Xiong, Tomnema

Journal of the American Heart Association | March 13, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/jaha.124.037019 Get It

Background Recent technologies enable real‐time 3‐dimensional intracardiac echocardiography (ICE) with the advantages of 2‐dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real‐world, multicenter safety and performance of a novel 3‐dimensional ICE system in a variety of cardiac interventions used in standard clinical practice. Methods This prospective, multicenter, observational, single‐arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3‐dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device‐related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success. Results Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%–99.8%), 96.1% (95% CI, 91.8%–98.6%), 94.8% (95% CI, 91.8%–98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be “acceptable” or greater in relation to reference image modality among 96.2% (149 of 155) of procedures. Conclusions VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high‐quality imaging of cardiac structures.
Immediate Reduction in Left Ventricular Contractility After Mitral Transcatheter Edge‐to‐Edge Repair Is Associated With Lower Rates of Heart Failure Hospitalizations
Chen, Ke‐Wei , Chang, Jeng-Sheng , Sularz, Agata , Russo, Gerardo Lo , Chang, Shih‐Sheng , Liu, C H, Alkhouli, Mohamad , Chang, Ju-Hsin , Lo Russo, Gerardo , Saleh, Ghasaq, Chang, Shih-Sheng , Liu, Chia-Hao , Alkhouli, Mohamad , Sularz, Agata , Saleh, Ghasaq

Journal of the American Heart Association | February 26, 2025 | Volume: 14 | Issue: 5 | Pages: No page available

10.1161/jaha.124.037545 Get It

Use of Protamine for Heparin Reversal in Patients Undergoing Transcatheter Aortic Valve Implantation: A Systematic Review and Meta-Analysis
Ahmed, Mushood , Ahsan, Areeba , Shafiq, Aimen , Burhan, Muhammad , Hashmi, Taqi , Shahid, Farhan , Alkhouli, Mohamad , Burhan, Muhammad , Ahmed, Raheel , Ahmed, Mushood , Burhan, Muhammad , Ahsan, Areeba , Hashmi, Tallal Mushtaq , Ahmed, Raheel , Alkhouli, Mohamad

American Journal of Therapeutics | February 6, 2025 | Volume: 33 | Issue: 1 | Pages: e110-e113

10.1097/mjt.0000000000001855 Get It

Valve thrombosis and antithrombotic therapy after bioprosthetic mitral valve replacement: a systematic review and meta-analysis
Zorman, Mark , Vibhishanan, Jonathan , Dangas, Katerina, Castle, James , Li, Ka Hou Christien , Coronelli, Marco , Eastwick-Jones, Kate , Swan, Alexander, Johnson, N M, Choksey, Anurag , Scott, Sam G.C., Henry, Matthew , Cassar, Mark Philip , Barnes, C. , Ferreira‐Martins, João , Newton, James D. , Alkhouli, Mohamad , Rihal, Charanjit S. , Eleid, Mackram F. , Zorman, Mark J , Newton, James , Dawkins, Sam , Rihal, Charanjit, Eleid, Mackram F , Sabbah, Michael S. , Swan, Alexander, Johnson, Nicky, Yan, Helen H.N. , Barnes, Cara, Alkhouli, Mohamad , Rihal, Charanjit S. , Pislaru, Sorin V. , Guerrero, Mayra , Ordóñez-Mena, José Manuel , Cahill, Thomas J.

European Heart Journal - Cardiovascular Pharmacotherapy | February 2, 2025 | Volume: 11 | Issue: 3 | Pages: 251-263

10.1093/ehjcvp/pvaf005 Get It

Abstract Aims Transcatheter mitral valve replacement (TMVR) has become a feasible alternative to surgical mitral valve replacement (SMVR) in selected patients at high surgical risk. The risk of valve thrombosis following SMVR and TMVR, and the optimal antithrombotic therapy following these procedures, remains uncertain. We aimed to compare the incidence of bioprosthetic mitral valve thrombosis (bMVT) after SMVR and TMVR, and the incidence of bMVT between patients on different antithrombotic regimens. Methods and results A literature search of Medline, Embase, and Cochrane Library was performed between January 2000 and August 2024. Random-effects models were used to derive pooled estimates of the incidence of bMVT in the absence of prior or active endocarditis and valve thrombosis. A total of 47 studies (6170 patients, total follow-up 9541.8 patient-years) were eligible for inclusion. The overall incidence of bMVT was 5.05 [95% confidence interval (CI) 3.18–8.01, I2 = 82%] per 100-patient-years. Subclinical bMVT was more common than clinically significant bMVT: incidence 19.11 vs. 7.91 per 100-patient-years, adjusted incidence rate ratio (aIRR) 4.62 (95% CI 1.39–15.36), P = 0.012. bMVT was numerically more common after TMVR than SMVR, but the comparison was not statistically significant: incidence 7.03 vs. 0.58 per 100-patient-years, aIRR 2.19 (95% CI 0.72–6.72), P = 0.170. Patients on vitamin-K antagonists (VKA) had a lower incidence of bMVT than patients on direct oral anticoagulants (DOAC; incidence 5.72 vs. 17.08, aIRR 0.31, 95% CI 0.13–0.73, P = 0.007). Conclusions bMVT is not uncommon, with numerically higher incidence in transcatheter compared to surgical valves, but the comparison was not statistically significant. VKAs are associated with a lower incidence of bMVT compared to DOACs.
Abstract 4140192: Time Trends in Outcomes of Trans-Catheter Aortic Valve Replacement with Balloon-expanding Versus Self-expanding Valves: A Meta-analysis of Randomized Controlled Trials
Mohammadi, Negin , Bahiraie, Pegah , Saeidi, Sahar , Namin, Sara Montazeri , Rahban, Habib , Pawar, Shubhadarshini , Soleimani, Hamidreza , Practice, Yaser Jenab Cardiology In, Makkar, Raj, Alkhouli, Mohamad , Gupta, Aakriti, Tavakoli, Kiarash , Shaker, Farhad , Moghadam, Arman Soltani , Tajdini, Masih , Makkar, Raj , Nanna, Michael G. , Iskander, Fady , Alkhouli, Mohamad , Gupta, Aakriti , Hosseini, Kaveh

Circulation | November 11, 2024 | Volume: 150 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.150.suppl_1.4140192 Get It

Background: The research on the outcomes of transcatheter aortic valve replacement with balloon-expandable valves (BEV) and self-expanding valves (SEV) are limited. Hypothesis: This study aims to compare the clinical and hemodynamic outcomes of BEV and SEV at short-term (30 days), mid-term (1 year), and long-term (>1 year) endpoints. Methods: PubMed, Embase, Scopus, and Cochrane Library databases were searched up to April 25, 2024, for randomized controlled trials (RCTs). Random-effect model (DerSimonian–Laird method) was used to pool the risk ratios (RR), mean differences (MD) and 95% confidence interval (CI) for binary and continuous outcomes, respectively. Results: A total of 11 RCTs comprising 4,325 patients (2,295 BEV, 2,030 SEV) were included. At short-term, the risk of cardiovascular (RR: 0.56, 95% CI: 0.36-0.87) and all-cause mortality (RR: 0.54, 95% CI: 0.35-0.81) were lower in the BEV group. However, no differences were noted between the two treatment modalities in longer follow-ups despite the lower risk of moderate to severe paravalvular leak (PVL) among BEV patients. The risk of stroke was comparable between two groups across all three follow-up endpoints, albeit a limited number of studies suggesting the BEV group showed a greater risk of clinical valve thrombosis in mid-term and long-term assessments. The need for permanent pacemaker implantation was lower in BEV arm in short-term (RR: 0.56, 95% CI: 0.37-0.87) and mid-term (RR: 0.78, 95% CI: 0.64-0.94). Yet, this difference was not observed in long-term follow-ups. Conversely, the SEV group had a larger effective orifice area with lower mean transvalvular pressure gradient from short-term (MD: 0.17, 95% CI: 0.07-0.26 and MD: 3.71, 95% CI: 2.64-4.78, respectively) to long-term (MD: 0.25, 95% CI: 0.17-0.32 and MD: 3.73, 95% CI: 3.19-4.27, respectively) periods. Conclusions: BEV is associated with reduced risk of clinical outcomes at short-term; however, most differences diminish in longer evaluations, except for moderate to severe PVL. Conversely, SEV is linked to better hemodynamic outcomes and a lower risk of clinical valve thrombosis across all follow-up durations.
Enhancing Coronary Revascularization Decisions: The Promising Role of Large Language Models as a Decision-Support Tool for Multidisciplinary Heart Team
Sudri, Karin , Motro-Feingold, Iris, Ramon‐Gonen, Roni , Barda, Noam , Klang, Eyal , Fefer, Paul , Amunts, Sergei , Attia, Zachi I. , Alkhouli, Mohamad , Segev, Amitai , Cohen-Shelly, Michal , Barbash, Israel M. , Attia, Zachi I , Barbash, Israel Moshe , Alkhouli, Mohamad

Circulation: Cardiovascular Interventions | November 6, 2024 | Volume: 17 | Issue: 11 | Pages: No page available

10.1161/circinterventions.124.014201 Get It

BACKGROUND: While clinical practice guidelines advocate for multidisciplinary heart team (MDHT) discussions in coronary revascularization, variability in implementation across health care settings remains a challenge. This variability could potentially be addressed by language learning models like ChatGPT, offering decision-making support in diverse health care environments. Our study aims to critically evaluate the concordance between recommendations made by MDHT and those generated by language learning models in coronary revascularization decision-making. METHODS: From March 2023 to July 2023, consecutive coronary angiography cases (n=86) that were referred for revascularization (either percutaneous or surgical) were analyzed using both ChatGPT-3.5 and ChatGPT-4. Case presentation formats included demographics, medical background, detailed description of angiographic findings, and SYNTAX score (Synergy Between Percutaneous Coronary Intervention With Taxus and Cardiac Surgery; I and II), which were presented in 3 different formats. The recommendations of the models were compared with those of an MDHT. RESULTS: ChatGPT-4 showed high concordance with decisions made by the MDHT (accuracy 0.82, sensitivity 0.8, specificity 0.83, and kappa 0.59), while ChatGPT-3.5 (0.67, 0.27, 0.84, and 0.12, respectively) showed lower concordance. Entropy and Fleiss kappa of ChatGPT-4 were 0.09 and 0.9, respectively, indicating high reliability and repeatability. The best correlation between ChatGPT-4 and MDHT was achieved when clinical cases were presented in a detailed context. Specific subgroups of patients yielded high accuracy (>0.9) of ChatGPT-4, including those with left main disease, 3 vessel disease, and diabetic patients. CONCLUSIONS: The present study demonstrates that advanced language learning models like ChatGPT-4 may be able to predict clinical recommendations for coronary artery disease revascularization with reasonable accuracy, especially in specific patient groups, underscoring their potential role as a supportive tool in clinical decision-making.