OBJECTIVE Artificial pancreas (AP) systems are best positioned for optimal treatment of type 1 diabetes (T1D) and are currently being tested in outpatient clinical trials. Our consortium developed and tested a novel adaptive AP in an outpatient, single-arm, uncontrolled multicenter clinical trial lasting 12 weeks. RESEARCH DESIGN AND METHODS Thirty adults with T1D completed a continuous glucose monitor (CGM)-augmented 1-week sensor-augmented pump (SAP) period. After the AP was started, basal insulin delivery settings used by the AP for initialization were adapted weekly, and carbohydrate ratios were adapted every 4 weeks by an algorithm running on a cloud-based server, with automatic data upload from devices. Adaptations were reviewed by expert study clinicians and patients. The primary end point was change in hemoglobin A1c (HbA1c). Outcomes are reported adhering to consensus recommendations on reporting of AP trials. RESULTS Twenty-nine patients completed the trial. HbA1c, 7.0 ± 0.8% at the start of AP use, improved to 6.7 ± 0.6% after 12 weeks (−0.3, 95% CI −0.5 to −0.2, P < 0.001). Compared with the SAP run-in, CGM time spent in the hypoglycemic range improved during the day from 5.0 to 1.9% (−3.1, 95% CI −4.1 to −2.1, P < 0.001) and overnight from 4.1 to 1.1% (−3.1, 95% CI −4.2 to −1.9, P < 0.001). Whereas carbohydrate ratios were adapted to a larger extent initially with minimal changes thereafter, basal insulin was adapted throughout. Approximately 10% of adaptation recommendations were manually overridden. There were no protocol-related serious adverse events. CONCLUSIONS Use of our novel adaptive AP yielded significant reductions in HbA1c and hypoglycemia.
Is Psychological Stress a Factor for Incorporation Into Future Closed-Loop Systems?
Background: The relationship between daily psychological stress and BG fluctuations in type 1 diabetes (T1DM) is unclear. More research is needed to determine if stress-related BG changes should be considered in glucose control algorithms. This study in the usual free-living environment examined relationships among routine daily stressors and BG profile measures generated from CGM readings. Methods: A total of 33 participants with T1DM on insulin pumps wore a CGM device for 1 week and recorded daily ratings of psychological stress, carbohydrates, and insulin boluses. Results: Within-subjects ANCOVAs found a significant relationship between daily stress and indices of BG variability/instability ( r = .172 to .185, P = .011 to .018, r 2 = 2.97% to 3.43%), increased % time in hypoglycemia ( r = .153, P = .036, r 2 = 2.33%) and decreased carbohydrate consumption ( r = –.157, P = .031, r 2 = 2.47%). Models accounted for more variance for individuals reporting the highest daily stress. There was no relationship between stress and mean daily glucose or low/high glucose risk indices. Conclusions: These preliminary findings suggest that naturally occurring daily stressors can be associated with increased glucose instability and hypoglycemia, as well as decreased food consumption. In addition, findings support the hypothesis that some individuals are more metabolically reactive to stress. More rigorous studies using CGM technology are needed to understand whether the impact of daily stress on BG is clinically meaningful and if it is a behavioral factor that should be considered in glucose control systems for some individuals.