Back to Authors

Padmanabhan, Deepak

https://orcid.org/0000-0002-9127-9275

Mayo Clinic

Mayo Clinic

Citations 56

Impact of intracardiac echocardiography on readmission morbidity and mortality following atrial fibrillation ablation
Deshpande, Saurabh , Sawatari, Hiroyuki , Ahmed, Raheel , Nair, Rakesh Gopinathan, Somers, Virend K., Chahal, C. Anwar A. , Padmanabhan, Deepak , Gopinathannair, Rakesh , Gopinathannair, Rakesh , Khan, Hassan , Padmanabhan, Deepak , Chahal, Choudhary Anwar A , Ahmed, Raheel , Deshpande, Saurabh , Khanji, Mohammed Y , Somers, Virend K.

Journal of Cardiovascular Electrophysiology | September 21, 2022 | Volume: 33 | Issue: 12 | Pages: 2496-2503

10.1111/jce.15683 Get It

AbstractIntroductionThe use of intracardiac echocardiography (ICE) is beneficial during the ablation of atrial fibrillation (AF). Evidence is conflicting regarding the clinical impact of using ICE on arrhythmia recurrence and mortality.MethodsPatients undergoing catheter ablation of AF during 2010–2017 were identified using the International Classification of Diseases‐9th and 10th Revision‐Clinical Modification (ICD‐9‐CM and ICD‐10‐CM) from the Nationwide Readmissions Database. Propensity matching was used to generate a control group. Patient demographics, Charlson comorbidity indexes, time from discharge to readmission, and the reason of readmission were extracted.ResultsFrom 2010 to 2017, 51 129 patients were included in the analysis out of which ICE was used in 8005 (15.7%) patients. The in‐hospital mortality at readmission was significantly higher in the patients without ICE use (2.9% vs. 1.7%, p = .02). The length of stay (LOS) at readmission was significantly higher in non‐ICE arm (median [interquartile range, IQR]: 3 [2–6] vs. 2 [3–5] days, p < .0001) with similar healthcare‐associated cost (HAC) in both the groups (median [IQR]: US$7507.3 [4057.8–15 474.2] vs. 7339.4 [4024.8–15 191.6], p = .43). Freedom from readmission was 12% higher (hazard ratio [HR] [95% confidence interval, CI]: 0.88 [0.83–0.94], p < .0001) with the use of ICE at 90‐day follow‐up, which was driven by 24% reduction in heart failure (HF) at follow‐up (HR [95% CI]: 0.76 [0.60–0.96], p = .02).ConclusionsICE use during AF ablation procedure reduces readmissions at 90 days by 12%, driven by a 24% decrease in HF‐related admissions. The non‐ICE arm showed a significantly higher LOS which offsets marginally higher HAC in the ICE arm.
Frequency of Arrhythmias and Postural Orthostatic Tachycardia Syndrome in Patients With Marfan Syndrome: A Nationwide Inpatient Study
Wafa, Syed Emir Irfan , Chahal, C. Anwar A. , Sawatari, Hiroyuki , Khanji, Mohammed Y , Asatryan, Babken , Ahmed, Raheel , Deshpande, Saurabh , Providência, Rui , Deshmukh, Abhishek , Owens, Anjali , Padmanabhan, Deepak , Connolly, Heidi M. , Khan, Hassan , Asatryan, Babken , Ahmed, Raheel , Deshpande, Saurabh , Providencia, Rui , Deshmukh, Abhishek J , Owens, Anjali T , Somers, Virend K. , Padmanabhan, Deepak , Connolly, Heidi M , Chahal, Choudhary Anwar A , Khanji, Mohammed Yunus , Somers, Virend K.

Journal of the American Heart Association | August 24, 2022 | Volume: 11 | Issue: 17 | Pages: No page available

10.1161/jaha.121.024939 Get It

Background Marfan syndrome (MFS) is an autosomal dominant connective tissue disorder affecting multiple systems, particularly the cardiovascular system. The leading causes of death in MFS are aortopathies and valvular disease. We wanted to identify the frequency of arrhythmia and postural orthostatic tachycardia syndrome, length of hospital stay, health care–associated costs (HAC), and in‐hospital mortality in patients with MFS. Methods and Results The National Inpatient Sample database from 2005 to 2014 was queried using International Classification of Diseases, Ninth Revision, Clinical Modification ( ICD‐9‐CM ) codes for MFS and arrhythmias. Patients were classified into subgroups: supraventricular tachycardia, ventricular tachycardia (VT), atrial fibrillation, atrial flutter, and without any type of arrhythmia. Data about length of stay, HAC, and in‐hospital mortality were also abstracted from National Inpatient Sample database. Adjusted HAC was calculated as multiplying HAC and cost‐to‐charge ratio; 12 079 MFS hospitalizations were identified; 1893 patients (15.7%) had an arrhythmia; and 4.9% of the patients had postural orthostatic tachycardia syndrome. Median values of length of stay and adjusted HAC in VT group were the highest among the groups (VT: 6 days, $18 975.8; supraventricular tachycardia: 4 days, $11 906.6; atrial flutter: 4 days, $11 274.5; atrial fibrillation: 5 days, $10431.4; without any type of arrhythmia: 4 days, $8336.6; both P =0.0001). VT group had highest in‐patient mortality (VT: 5.3%, atrial fibrillation: 4.1%, without any type of arrhythmia: 2.1%, atrial flutter: 1.7%, supraventricular tachycardia: 0%; P <0.0001) even after adjustment for potential confounders (without any type of arrhythmia versus VT; odds ratio [95% CI]: 3.18 [1.62–6.24], P =0.001). Conclusions Arrhythmias and postural orthostatic tachycardia syndrome in MFS were high and associated with increased length of stay, HAC, and in‐hospital mortality especially in patients with VT.
14 Impact of epilepsy or seizures on outcomes following takotsubo cardiomyopathy
Sawatari, Hiroyuki , Wafa, Syed Emir Irfan , Padmanabhan, Deepak , Ahmed, Raheel , Deshpande, Saurabh , Khanji, Mohammed Y , Somers, Virend K. , Chahal, C. Anwar A.

ACHD/Valve disease/Pericardial disease/Cardiomyopathy | June 6, 2022 | Volume: No volume available | Issue: No issue available | Pages: A11.2-A12

10.1136/heartjnl-2022-bcs.14 Get It

Abstract 55: Use of a Novel Electrogram Filter to Visualise the Conduction Tissue Signals in the Ventricle in Sinus Rhythm and Arrhythmia: Canine Studies
Padmanabhan, Deepak , Witt, Chance M. , Sugrue, Alan , Killu, Ammar M. , Naksuk, Niyada , Ladewig, Dorothy J., Powers, Joanne, Suddendorf, Scott H., DeSimone, Christopher V. , Asirvatham, Samuel J.

Circulation Research | March 20, 2022 | Volume: 121 | Issue: suppl_1 | Pages: No page available

10.1161/res.121.suppl_1.55 Get It

Background: Conduction tissue in the ventricles is closely intertwined with myocardium. Owing to high velocity of conduction, there is near simultaneous activation , making it difficult to discern. Restricted sampling rates and limited dynamic range make real time signal processing challenging for these signals in routine recording systems. Objectives: We aimed to use novel signal processing techniques in a new system to isolate the conduction tissue signals from the rest of the myocardial activation. Methods: We used the PURE-EP™ (BioSig Technologies, MN) signal processing system to record endocardial and epicardial signals from 6 anesthetized canines in an acute study setting. A novel filter based on proprietary algorithms to isolate the high frequency signal was applied at sites where the electrogram signals were thought to have a conduction tissue component to them. . In addition, ventricular fibrillation (VF) was induced at the end of the experiment and signals were then recorded from the endocardium and the conduction system. Results: This filter was successfully able to isolate conduction tissue signals in the myocardium from those of the ventricular muscle. It did over sense atrial signals at the basal left ventricular septum owing to the high frequency components of the atrial signal at this location. When applied to epicardial signals, it did not pick up any conduction tissue signals. In VF, we could discern signals originating from the conduction system endocardially. (Figure 1) Conclusions: This filter can isolate conduction tissue signals from those of the myocardium and may prove to be a useful adjunct in mapping arrhythmias originating near the conduction system.
Abstract 16562: Cardiac Device Implantation Post TAVR: Mortality and Rates of Pacemaker Dependency
Padmanabhan, Deepak , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong-Mei M, Asirvatham, Samuel, Friedman, Paul A. , Greason, Kevin L. , Gulati, Rajiv , Scott, Christopher G. , McLeod, Christopher J. , Cha, Yong-Mei M, Noseworthy, Peter A.

Circulation | March 19, 2022 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16562 Get It

Background: Transcatheter aortic valve replacement (TAVR) is often complicated by AV block requiring pacing, but whether patients recover AV conduction and whether the need for pacing affects outcomes is unknown. Methods: We retrospectively studied 534 patients who underwent TAVR at Mayo Clinic in Rochester, Minnesota between November 2008 and January 2015. Of these, 115 patients had implantable cardiac devices. Data was collected from subsequent device follow-ups to determine pacemaker dependency and percentage pacing. Results: 44 patients (8.2%) had devices implanted in the immediate post procedural period. The most common indications for implantation were high grade AV block (18 patients) and complete heart block (14 patients). 17/44 (38.6%) patients were pacemaker-dependent at implant and only 4 of these patients were no longer pacemaker-dependent during subsequent followup. The indication for pacing among these four patients was high grade atrio-ventricular block (2 patients), asystole (1 patient) and complete heart block (1). Among non-pacemaker-dependent patients, no significant change in the ventricular pacing percentages was noted over time. Survival was similar between patients who required device implantation post TAVR and those who did not after adjustment for age and gender (HR 0.73 [0.39-1.36], p=ns; figure) Conclusion: Patients requiring pacing after TAVR are often pacemaker-dependent at the time of implant. It is uncommon for patients who are dependent at the time of implant to regain AV conduction, but the need for cardiac pacing is not associated with increased mortality.
Cover Image, Volume 32, Issue 11
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , Knight, Bradley P , Tzou, Wendy , Schaller, Robert D. , McLeod, Christopher J. , Natale, Andrea

Journal of Cardiovascular Electrophysiology | November 6, 2021 | Volume: 32 | Issue: 11 | Pages: No page available

10.1111/jce.15283 Get It

Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , McLeod, Christopher , Natale, Andrea , Knight, Bradley P , Tzou, Wendy , Yasin, Omar , Padmanabhan, Deepak , Natale, Andrea , Schaller, Robert D. , McLeod, Christopher

Journal of Cardiovascular Electrophysiology | September 23, 2021 | Volume: 32 | Issue: 11 | Pages: 2915-2922

10.1111/jce.15250 Get It

AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.
Abstract 18323: Complication Rates of Ventricular Tachycardia Ablation: Comparison of Safety Outcomes From Real World to Contemporary Clinical Studies
Pothineni, Naga Venkata K. , Deshmukh, Abhishek , Padmanabhan, Deepak , Kovelamudi, Swathi, Mulpuru, Siva K. , Paydak, Hakan, Noseworthy, Peter A.

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.18323 Get It

Introduction: The availability, national scope and perceived unbiased nature of administrative claims data makes it an attractive choice by health care policy makers for evaluating quality and outcomes. We calculated Ventricular tachycardia (VT) ablation complication rates from national administrative data and compared them with data from randomized trials and prospective studies. Methods: A PUBMED database search was done to identify existing studies of VT ablation. Studies were divided into clinical (randomized controlled trials (RCTs) and prospective studies). Pooled rates of vascular, cardiac, neurological complications and procedure related mortality were computed and compared to reported complication rates from administrative database studies Results: We identified two administrative database studies of VT ablation that included a total of 14,352 procedures and 18 clinical studies with a total of 1,705 procedure. Overall complication rate in administrative studies was higher than in clinical studies (9.39% vs. 7.97%). Rates of cardiac/pericardial (4.47% vs. 2.29%) and vascular access complications (6.9% vs. 3.0%) were higher in real world studies. Neurological complications (1.17% vs. 0.45%) and procedure related mortality (1.53% vs. 1.29%) were higher in clinical studies. Among clinical studies, RCTs had the lowest reported complication rate. Conclusion: Despite substantial improvement, “real-world” complication rates from administrative data remain higher than those reported in RCTs. The discrepancy may be attributable to differences in operator skills, selection bias and variation in data quality. Use of large databases provides an important analytical resource as we embark on improving national health care efficacy and safety in the current challenging environment.
Abstract 17289: Incidence of Cardiomyopathy and Mortality in Patients With Cobalt and Chromium Metal Hip Arthroplasty
Ponamgi, Shiva , Sharma, Sunita , Sun, Philip Philip, Yogeswaran, Vidushei, Padmanabhan, Deepak , El‐Harasis, Majd , Hodge, David O. , Slusser, Joshua P. , Abdel, Matthew, Sun, Philip Y. , Sun, Philip , DeSimone, Christopher V. , Wyles, Cody C. , Sun, Philip Philip, Asirvatham, Samuel J.

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17289 Get It

Introduction: One million patients around the world have had total hip arthorplasty with 35% of them having metal-on-metal implants. Although there have been some case reports of cobalt cardiotoxicity from arthroprosthetic cobaltism resulting in dilated cardiomyopathy, incidence of cardiomyopathy and mortality in these patients is unknown. Objective: We therefore sought to determine the incidence of new onset cardiomyopathy (EF <40%) and associated mortality, in patients with metal hip arthroplasty. Methods: We retrospectively examined the records of the patients form our institutional total hip arthroplasty registry (Metal on Metal: MoM, Metal on Polyethylene: MoP, Ceramic on Ceramic: CoC and Ceramic on Polyethylne: CoP). Among 122 patients with baseline and follow up echocardiograms, cobalt and chromium levels were available in 12 patients, none of which developed incident cardiomyopathy. Results: The mean age of the population with metal group (MoM and MoP) was 53 years, predominantly males. During the follow up period of 10 years, the cumulative incidence (KM curve probabilities) of low EF <=40% in our study population was 14% in metal group as compared to 5% in non-metal group (CoC and CoP), (p value 0.51). At 15 years of follow up, among 122 patients, there were16 deaths in the metal group (81) and only 2 deaths in the non-metal group (41) (p value 0.15). Conclusions: In conclusion, although the incidence of cardiomyopathy as well as mortality is low in patients with metal hip arthroplasty and not significantly, further studies maybe needed to assess its effect on diastolic dysfunction.
Abstract 17269: Incidence of Atrial Fibrillation in Patients With Cobalt and Chromium Containing Hip Arthroplasty
Sharma, Sunita , Ponamgi, Shiva , Sun, Philip Y. , Yogeswaran, Vidushei, Padmanabhan, Deepak , El‐Harasis, Majd , Hodge, David O. , Slusser, Joshua P. , Asirvatham, Samuel, Sun, Philip , DeSimone, Christopher V. , Wyles, Cody C. , Abdel, Matthew P.

Circulation | July 2, 2021 | Volume: 138 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.138.suppl_1.17269 Get It

Background: Worldwide, approximately one million patients have had total hip arthroplasty with 35% being cobalt and chromium Metal-on-Metal (MoM) or Metal-on-Polythelene (MoP) implants. Animal models have suggested that cobalt and chromium can affect all chambers, but there seems to be an atrial predilection. There are several case reports of metal containing hip arthroplasty causing atrial arrhythmias but the true incidence of atrial fibrillation associated with metal hip arthroplasty remains undefined. Objective: We sought to determine the incidence of atrial fibrillation in patients with metal containing hip arthroplasty. We also examined the association between serum cobalt and chromium levels and arrhythmias in this cohort and all cause mortality. Methods: We retrospectively examined the records of patients from the Mayo Clinic total hip arthroplasty registry (Metal group - Metal-on-Metal: MoM and Metal-on-Polyethylene: MoP, Non-Metal group - Ceramic-on-Ceramic: CoC and Ceramic-on-Polyethylne: CoP) to obtain demographic data, comorbidities, laboratory, ECG, and echocardiographic data. Out of a total of 1756 patients, Cobalt and Chromium levels were available in 138 patients. Results: The mean age of patients with metal containing hip replacement was 50 years and were predominantly male. During a follow up period of 10 years, the incidence of atrial fibrillation in our study population was 8% in metal group compared to 2% (p=0.11) in non-metal group. There was no association between cobalt or chromium levels with the incidence of atrial fibrillation. All-cause mortality was significantly higher in metal group versus non-metal group (p=0.005). Conclusion: The incidence of atrial fibrillation was relatively more in patients with metal versus non-metal hip arthroplasty but there was no association of serum cobalt or chromium levels with incidence of atrial fibrillation in the subset of patients. In addition, all-cause mortality was significantly higher in the metal group suggesting potential toxic effects of metal containing hip arthroplasty.