Abstract Objective To measure the relative levels of signal and noise in expert diagnosis of epilepsy. Methods Twenty multinational epileptologists independently reviewed 50 vignettes of adult and pediatric patients presenting with suspected seizure(s) on two separate occasions with a ≥30‐day washout period. Experts provided a diagnosis of epilepsy or non‐epilepsy based on clinical information and, if requested, routine EEG and neuroimaging data. Cases had an established clinical diagnosis of epilepsy or non‐epilepsy based on capture of habitual paroxysmal events on video‐EEG or long‐term clinical follow‐up. Experts' judgments were analyzed to decompose variability into different sources: signal (objective differences between cases), level noise (experts' bias toward over/under‐diagnosis), pattern noise (experts' idiosyncratic reactions to specific case features), and occasion noise (inconsistency across occasions). Results The probability of an expert making a different diagnosis for a given case on two different occasions was 16%. The probability of two different experts making a different diagnosis for the same case was 26%. Signal (case “difficulty”) accounted for 66–69% of total variation, with 31–34% attributable to noise. Level noise was the largest contributor in the absence of EEG/neuroimaging results (23%), while pattern noise dominated when test results were available (24%). Occasion noise contributed relatively little (1%) but was still sufficient to cause diagnostic reversals in 16–22% between occasions. Significance The degree of noise in expert diagnosis of epilepsy is substantial, stemming primarily from physicians' idiosyncratic interpretations of case features and variable dispositions toward over‐ or under‐diagnosis. Strategies to improve reliability are needed, including standardized data collection protocols and structured decision algorithms. For “difficult cases,” where expert reliability and accuracy are lowest, our findings support current clinical practice which favors early referral for video‐EEG monitoring over reliance on diagnostic anchoring. This diagnostic pathway may become more accessible with advances in EEG technology (e.g., wearable devices) and artificial intelligence.
Expert-Level Detection of Epilepsy Markers in EEG on Short and Long Timescales
Summary: Ambulatory EEG (AEEG) devices offer portable, multichannel, digital EEG recording with or without video in the patient's natural environment. The technology applied for AEEG recording is like the technology for routine EEG and inpatient long-term video-EEG monitoring but designed to be compact and wearable. Computer-based AEEG technology is well-suited to digital recording, signal processing, and visual display. However, acquiring interpretable EEG outside of the hospital setting presents its own technical challenges. Published guidelines have established technical standards for performing routine EEG and inpatient video-EEG monitoring, but technical standards for AEEG are lacking. Therefore, this guideline provides minimal technical standards for the performance of AEEG which are essential to ensure the quality of studies for clinical and research practice. We expect these minimum standards to evolve over time with improved performance and advances in the technology.
Minimum standards for inpatient long‐term video‐electroencephalographic monitoring: A clinical practice guideline of the International League Against Epilepsy and International Federation of Clinical Neurophysiology
Summary The objective of this clinical practice guideline is to provide recommendations on the indications and minimum standards for inpatient long‐term video‐electroencephalographic monitoring (LTVEM). The Working Group of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology develop guidelines aligned with the Epilepsy Guidelines Task Force. We reviewed published evidence using the PRISMA (Preferred Reporting Items for Systematic Review and Meta‐Analysis) statement. We found limited high‐level evidence aimed at specific aspects of diagnosis for LTVEM performed to evaluate patients with seizures and nonepileptic events. For classification of evidence, we used the Clinical Practice Guideline Process Manual of the American Academy of Neurology. We formulated recommendations for the indications, technical requirements, and essential practice elements of LTVEM to derive minimum standards used in the evaluation of patients with suspected epilepsy using GRADE (Grading of Recommendations Assessment, Development, and Evaluation). Further research is needed to obtain evidence about long‐term outcome effects of LTVEM and to establish its clinical utility.
Nine-year prospective efficacy and safety of brain-responsive neurostimulation for focal epilepsy
Summary Objective A prospective multicenter phase III trial was undertaken to evaluate the performance and tolerability in the epilepsy monitoring unit ( EMU ) of an investigational wearable surface electromyographic ( sEMG ) monitoring system for the detection of generalized tonic–clonic seizures ( GTCSs ). Methods One hundred ninety‐nine patients with a history of GTCSs who were admitted to the EMU in 11 level IV epilepsy centers for clinically indicated video‐electroencephalographic monitoring also received sEMG monitoring with a wearable device that was worn on the arm over the biceps muscle. All recorded sEMG data were processed at a central site using a previously developed detection algorithm. Detected GTCSs were compared to events verified by a majority of three expert reviewers. Results For all subjects, the detection algorithm detected 35 of 46 (76%, 95% confidence interval [CI] = 0.61–0.87) of the GTCSs, with a positive predictive value ( PPV ) of 0.03 and a mean false alarm rate ( FAR ) of 2.52 per 24 h. For data recorded while the device was placed over the midline of the biceps muscle, the system detected 29 of 29 GTCSs (100%, 95% CI = 0.88–1.00), with a detection delay averaging 7.70 s, a PPV of 6.2%, and a mean FAR of 1.44 per 24 h. Mild to moderate adverse events were reported in 28% (55 of 199) of subjects and led to study withdrawal in 9% (17 of 199). These adverse events consisted mostly of skin irritation caused by the electrode patch that resolved without treatment. No serious adverse events were reported. Significance Detection of GTCSs using an sEMG monitoring device on the biceps is feasible. Proper positioning of this device is important for accuracy, and for some patients, minimizing the number of false positives may be challenging.
American Clinical Neurophysiology Society: EEG Guidelines Introduction