Back to Authors

Fahoum, Firas

https://orcid.org/0000-0003-2262-5530

Mayo Clinic

Tel Aviv University

Citations 3

Automated Interpretation of Clinical Electroencephalograms Using Artificial Intelligence
Tveit, Jesper , Aurlien, Harald , Calhoun, Vince D. , Tatum, William O. , Schomer, Donald L., Arntsen, Vibeke, Cox, F. M. , Fahoum, Firas , Gallentine, William B., Husain, Aatif M. , Kessler, Sudha Kilaru , Kural, Mustafa Aykut , Ulvin, Line Bédos , Wennberg, Richard , Calhoun, Vince D. , Fahoum, Firas , Plis, Sergey , Gardella, Elena , Hahn, Cecil D. , Nascimento, Fábio A. , Tankişi, Hatice , Beniczky, Sándor

JAMA Neurology | June 20, 2023 | Volume: 80 | Issue: 8 | Pages: 805

10.1001/jamaneurol.2023.1645 Get It

Importance Electroencephalograms (EEGs) are a fundamental evaluation in neurology but require special expertise unavailable in many regions of the world. Artificial intelligence (AI) has a potential for addressing these unmet needs. Previous AI models address only limited aspects of EEG interpretation such as distinguishing abnormal from normal or identifying epileptiform activity. A comprehensive, fully automated interpretation of routine EEG based on AI suitable for clinical practice is needed. Objective To develop and validate an AI model (Standardized Computer-based Organized Reporting of EEG–Artificial Intelligence [SCORE-AI]) with the ability to distinguish abnormal from normal EEG recordings and to classify abnormal EEG recordings into categories relevant for clinical decision-making: epileptiform-focal, epileptiform-generalized, nonepileptiform-focal, and nonepileptiform-diffuse. Design, Setting, and Participants In this multicenter diagnostic accuracy study, a convolutional neural network model, SCORE-AI, was developed and validated using EEGs recorded between 2014 and 2020. Data were analyzed from January 17, 2022, until November 14, 2022. A total of 30 493 recordings of patients referred for EEG were included into the development data set annotated by 17 experts. Patients aged more than 3 months and not critically ill were eligible. The SCORE-AI was validated using 3 independent test data sets: a multicenter data set of 100 representative EEGs evaluated by 11 experts, a single-center data set of 9785 EEGs evaluated by 14 experts, and for benchmarking with previously published AI models, a data set of 60 EEGs with external reference standard. No patients who met eligibility criteria were excluded. Main Outcomes and Measures Diagnostic accuracy, sensitivity, and specificity compared with the experts and the external reference standard of patients’ habitual clinical episodes obtained during video-EEG recording. Results The characteristics of the EEG data sets include development data set (N = 30 493; 14 980 men; median age, 25.3 years [95% CI, 1.3-76.2 years]), multicenter test data set (N = 100; 61 men, median age, 25.8 years [95% CI, 4.1-85.5 years]), single-center test data set (N = 9785; 5168 men; median age, 35.4 years [95% CI, 0.6-87.4 years]), and test data set with external reference standard (N = 60; 27 men; median age, 36 years [95% CI, 3-75 years]). The SCORE-AI achieved high accuracy, with an area under the receiver operating characteristic curve between 0.89 and 0.96 for the different categories of EEG abnormalities, and performance similar to human experts. Benchmarking against 3 previously published AI models was limited to comparing detection of epileptiform abnormalities. The accuracy of SCORE-AI (88.3%; 95% CI, 79.2%-94.9%) was significantly higher than the 3 previously published models ( P < .001) and similar to human experts. Conclusions and Relevance In this study, SCORE-AI achieved human expert level performance in fully automated interpretation of routine EEGs. Application of SCORE-AI may improve diagnosis and patient care in underserved areas and improve efficiency and consistency in specialized epilepsy centers.
Seizure semiology: ILAE glossary of terms and their significance
Tatum, William O. , Blumenfeld, Hal , Stefan, Hermann , Mani, Jayanti , Maillard, Louis , Fahoum, Firas , Vinayan, Kollencheri Puthenveettil , Vlachou, Maria , Seeck, Margitta, Ryvlin, Philippe , Kahane, Philippe, Ryvlin, Philippe , Fahoum, Firas , Beniczky, Sándor , Mayor, Luis Carlos , Seeck, Margitta

Epileptic Disorders | July 1, 2022 | Volume: 24 | Issue: 3 | Pages: 447-495

10.1684/epd.2022.1430 Get It

Abstract This educational topical review and Task Force report aims to address learning objectives of the International League Against Epilepsy (ILAE) curriculum. We sought to extract detailed features involving semiology from video recordings and interpret semiological signs and symptoms that reflect the likely localization for focal seizures in patients with epilepsy. This glossary was developed by a working group of the ILAE Commission on Diagnostic Methods incorporating the EEG Task Force. This paper identifies commonly used terms to describe seizure semiology, provides definitions, signs and symptoms, and summarizes their clinical value in localizing and lateralizing focal seizures based on consensus in the published literature. Video‐EEG examples are included to illustrate important features of semiology in patients with epilepsy.
Minimum standards for inpatient long‐term video‐electroencephalographic monitoring: A clinical practice guideline of the International League Against Epilepsy and International Federation of Clinical Neurophysiology
Tatum, William O. , Mani, Jayanti , Halford, Jonathan J. , Gloss, David , Fahoum, Firas , Maillard, Louis , Mothersill, Ian, Halford, Jonathan J , Fahoum, Firas , Beniczky, Sándor , Jin, Kazutaka

Epilepsia | December 13, 2021 | Volume: 63 | Issue: 2 | Pages: 290-315

10.1111/epi.16977 Get It

Summary The objective of this clinical practice guideline is to provide recommendations on the indications and minimum standards for inpatient long‐term video‐electroencephalographic monitoring (LTVEM). The Working Group of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology develop guidelines aligned with the Epilepsy Guidelines Task Force. We reviewed published evidence using the PRISMA (Preferred Reporting Items for Systematic Review and Meta‐Analysis) statement. We found limited high‐level evidence aimed at specific aspects of diagnosis for LTVEM performed to evaluate patients with seizures and nonepileptic events. For classification of evidence, we used the Clinical Practice Guideline Process Manual of the American Academy of Neurology. We formulated recommendations for the indications, technical requirements, and essential practice elements of LTVEM to derive minimum standards used in the evaluation of patients with suspected epilepsy using GRADE (Grading of Recommendations Assessment, Development, and Evaluation). Further research is needed to obtain evidence about long‐term outcome effects of LTVEM and to establish its clinical utility.