Hip simulators are regularly used by researchers to assess total hip arthroplasty (THA) implants, range of motion, stability, and alignment of acetabular cup and stem. Previous papers have described three types of simulators: three-dimensional protractors, biaxial rocking motion (BRM) protractors, and single-axis prosthetic range-of-motion (PROM) devices. We have developed a new hip simulator in which the ROM device is completely automated in three independent axes (elevation, internal/external rotation, and plane of elevation). Coupled with the simulator, we used a FaroArm Gold Series coordinate measuring machine (CMM) to accurately align the implant components. The results show that the methodology and alignment setup are accurate and repeatable. With this simulator and digitizer, we are able to study the characteristics of numerous THA implants at various orientations of the pelvis, acetabular cup, stem, and femur.
Rotator Cuff Repair Using an Acellular Dermal Matrix Graft: An In Vivo Study in a Canine Model
Purpose Large rotator cuff tears present a challenge to orthopaedic surgeons. Because tissue may be insufficient or of inadequate quality to undergo repair, a variety of materials have been used as adjuncts. Human dermal tissue may be processed to render it acellular, and thus less immunogenic, but with the extracellular matrix left intact, creating a collagen scaffold with favorable characteristics. Because of these traits, use in rotator cuff repair was proposed. Methods A canine model for a full‐thickness infraspinatus tendon tear was used. Tendon was excised from the bony interface to the myotendinous junction, and a human acellular dermal matrix graft (experimental) or the autologous excised tendon (control) was used to bridge the defect. Animals were sacrificed, and shoulders were evaluated histologically and biomechanically. Results At time 0, strength of control and experimental repairs was similar. At 6 weeks, the strength of the experimental repair was half that of the control side. Strength of control specimens remained the same at 6 and 12 weeks, but by 12 weeks, the strength of the experimental repair was equal to that of the control. Histologically, cells infiltrated the control and experimental specimens by 6 weeks; chronic inflammation was consistent with surgery and repair. At 6 months, control and experimental specimens mimicked normal tendon structure grossly and histologically. Conclusions Use of human acellular dermal matrix as a patch is a viable option in this model of large rotator cuff defects. Within 6 weeks, histologic evidence of native cell infiltration and neotendon development was observed. Within 12 weeks, the strength of the dermal matrix graft repair was equivalent to that of autologous tendon. At 6 months, control and graft specimens mimicked normal tendon structure grossly and histologically. Clinical Relevance This study provides in vivo animal data to support the use of this acellular dermal matrix graft for repair of full‐thickness rotator cuff defects. Additional studies are indicated to determine the role of this material in the treatment of humans with rotator cuff tears.
Summary Nine fresh frozen cadaveric shoulders were used to examine the changes in intraarticular pressure (IAP) of the shoulder joint and the position of the humeral head under various loads to determine the relationship between these parameters. All the soft tissues superficial to the rotator cuff were removed. The position of the humerus relative to the scapula was monitored using an electromagnetic tracking system before and after venting the capsule with 0, 0.5, and 1.0 kg of load applied to the humerus inferiorly in addition to the weight of the arm. Simultaneously, the IAP was monitored using a pressure transducer before venting the capsule. Venting had a significant effect on the position of the humeral head: the positions of the head after venting were significantly lowered in all loading conditions. The average IAP was −76 cm H 2 O without load, and the value decreased in a linear fashion with increased load; the correlations were significant in four of six shoulders without dislocation. The correlations were less significant between the pressure and the position, and there were no significant correlations between the load and the position. IAP, which is determined primarily by the load applied, is important to stabilize the shoulder inferiorly. Because IAP is intimately related to the external load and the response is specific to individuals, examination of IAP response to external load may be helpful in characterizing various instabilities of the shoulder.
Healing of Canine Tendon in Zones Subjected to Different Mechanical Forces
The effect of external force environment on the healing of a partial thickness injury to canine flexor tendon was studied. A 50% laceration was made in either the fibrocartilaginous (compressive) zone or in the tendinous (tensile) zone of canine flexor digitorum profundus tendons. After three or six weeks, the tendons were harvested. An optical method for determining zone-specific material properties showed that, in response to injury, the structural stiffness decreased in the tensile zone of the tendon but increased in the compressive zone. The mechanical properties and failure mechanism of canine tendon and their changes in response to injury vary according to tendon zone, and differences in the healing process in mechanically specialised zones of the flexor tendon are discussed.
Biomechanical Efficiency of Wrist Guards as a Shock Isolator
Despite the use of wrist guards during skate- and snowboard activities, fractures still occur at the wrist or at further proximal locations of the forearm. The main objectives of this study were to conduct a human subject testing under simulated falling conditions for measurement of the impact force on the hand, to model wrist guards as a shock isolator, to construct a linear mass-spring-damper model for quantification of the impact force attenuation (Q-ratio) and energy absorption (S-ratio), and to determine whether wrist guards play a role of an efficient shock isolator. While the falling direction (forward and backward) significantly influenced the impact responses, use of wrist guards provided minimal improvements in the Q- and S-ratios. It was suggested based on the results under the submaximal loading conditions that protective functions of the common wrist guard design could be enhanced with substantial increase in the damping ratio so as to maximize the energy absorption. This would bring forth minor deterioration in the impact force attenuation but significant increase in the energy absorption by 19%, which would help better protection against fall-related injuries of the upper extremity.
Development of a Biologic Prosthetic Composite for Cartilage Repair
The physical attributes of the three capitohamate interosseous ligaments were tested in a computer-controlled multi-axis testing machine using 12 human cadaver specimens. After an intact test run, selected ligaments were cut in random sequence and the test repeated. The remaining ligaments were tested to failure with servohydrolic stress at 5 mm/second. In the intact joint complex, the average dorsopalmar rotational displacement was approximately 9° in each direction. Under the load limit, the dorsopalmar translational displacement averaged 0.9 mm and 0.5 mm respectively, proximal–distal translational displacement averaged 0.8 mm and 0.4 mm respectively, and distractional displacement averaged 0.3 mm. Based on the sequential sectioning it was found that the dorsal ligament provided 76% (SD 14) of the rotational resistance with palmar rotation of the capitate and 44% (SD 19) of translational constraint with palmar translation of the capitate. The deep ligament provided 51% (SD 15) of the rotational resistance with dorsal rotation of the capitate and 63% (SD 24) of translational resistance with dorsal translation of the capitate. With proximal—distal translation, the dorsal ligament was the most important constraint in each direction. In resisting distraction, each of the three ligaments was equally effective. Failure testing showed the deep ligament was strongest at 289 N, followed by the palmar at 171 N and the dorsal at 133 N.
Providing Quantitative Feedback When Teaching Tendon Repair: A New Tool
Flexor tendon repair remains one of the more difficult technical tasks facing the hand surgeon. A good repair must be both strong and able to glide smoothly through the tendon sheath. The purpose of this study is to present a model that allows surgeons to improve their technique of flexor tendon repair by receiving feedback on these important biomechanical parameters. The set-up requires testing equipment found in most biomechanical laboratories and should be available in many academic medical centres. Preliminary data suggest that receiving feedback about the strength and smoothness of a flexor tendon repair may be a very useful tool in helping surgeons improve the overall quality of their tendon repair technique.
“Physiological” Tensions of the Ulnar Nerve with Limb Positioning
Muscle physiological cross-sectional area, as defined and measured by dividing the volume of the muscle by its fibre length, is proportional to the maximum strength of the muscle. It is one of the important parameters when considering muscle mechanics in sports science and, clinically in tendon transfer procedures. This study reports that tendon cross-sectional area correlated well with the physiological cross-sectional area of associated muscles.