Fracture of the lateral process of the talus is an injury unique to snowboarders and is of particular clinical relevance because it masquerades as an anterolateral ankle sprain and is difficult to detect on standard radiographic views. Misdiagnosis can lead to long-term morbidity in a young and active population, with ensuing severe degeneration of the subtalar joint. To date, the precise mechanism of injury has not been established, making it difficult to identify potential preventive strategies in equipment design or snowboarding technique. Fracture of the lateral process of the talus in snowboarders has been thought to result from pure dorsiflexion and inversion combined with axial loading. We hypothesized, however, that external rotation is a key component of the mechanism of injury. Ten cadaveric ankles were mounted on a materials testing machine in a position of fixed dorsiflexion and inversion. All ankles were loaded to failure axially, with or without combined external rotation. No fractures occurred after axial loading in dorsiflexion and inversion, but six of eight specimens sustained fractures of the lateral process of the talus when similarly loaded with external rotation added, supporting our hypothesis. Further study is needed to evaluate the relationship between various types of snowboarding equipment and fracture mechanism.
WOUND-HEALING PROPERTIES OF TRANSFORMING GROWTH FACTOR β (TGF-β) INDUCIBLE EARLY GENE 1 (TIEG1) KNOCKOUT MICE
Transforming growth factor beta (TGF-β) has a broad effect on wound healing, but many questions remain about the regulation of TGF-β during the healing process. TGF-β inducible early gene 1 (TIEG1) is a primary response gene for TGF-β that controls the activities of the TGF-β/Smad pathway, the primary TGF-β signaling pathway. The purpose of this study was to investigate the role of TIEG1 in cutaneous wound healing using TIEG1 knockout mice. The wound healing in TIEG1 knockout mice and wild-type controls was evaluated by wound breaking strength, Western blot, and histology at postoperative days 3, 7, and 14. Although re-epithelialization of both groups was similarly complete at day 7, the TIEG1 knockout mice had a significantly lower wound breaking strength than the controls at postoperative day 14. These results suggest that TIEG1 expression may be an important factor involved in the initiation and support of normal cutaneous wound healing.
Dextrose-Induced Subsynovial Connective Tissue Fibrosis in the Rabbit Carpal Tunnel: A Potential Model to Study Carpal Tunnel Syndrome?
In this pilot study, hypertonic dextrose solution was used to induce fibrosis of the subsynovial connective tissue (SSCT) and create an animal model of potential use in the study of carpal tunnel syndrome (CTS). The SSCT of the carpal tunnel in 15 New Zealand white rabbits were injected with 0.05 ml of 10% dextrose solution in 1 paw and 0.05 ml of saline in the contralateral paw, to serve as a control. The animals were killed at 1, 2, 4, 8, or 12 weeks. While the saline side showed minimal changes at any time period, the hypertonic dextrose side showed progressive noninflammatory SSCT fibrosis, with vascular proliferation and thickening of collagen bundles. Demyelination of the median nerve developed at 12 weeks after the injection on the dextrose side. These findings are similar to the progression of pathology noted in humans with CTS.
Mechanical Properties of Patellar Tendon Allografts Subjected to Chemical Sterilization
Purpose We tested the hypothesis that the preimplantation mechanical properties of BioCleanse‐treated bone–patellar tendon–bone (BPTB) allografts are not significantly different from those of untreated specimens. Methods For this controlled laboratory study, specimens were harvested as central third or hemi‐BPTB units from both knees of 17 cadaveric tissue donors (11 men and 6 women) aged 19 to 88 years. Donor‐matched specimens (20 per group) were randomly assigned to either BioCleanse‐treated or untreated control groups. Specimens were subjected to 25 minutes of pretensioning at 89 N and then cyclically loaded under longitudinal tension between 50 N and 250 N for 1,000 cycles at 1 Hz, followed by ramp to failure at 50 mm/min. Results No statistically significant difference was found between untreated and BioCleanse‐treated specimens in stiffness (235.3 ± 37.6 N/mm v 222.3 ± 53.4 N/mm, P = .37), cyclic creep (0.38 ± 0.42 mm v 0.40 ± 0.26 mm, P = .81), maximum force (1,685.7 ± 471.6 N v 1,807.0 ± 657.8 N, P = .47), or ultimate stress (29.0 ± 9.8 MPa v 29.0 ± 12.8 MPa, P = .98). Conclusions The preimplantation mechanical properties of BPTB allografts treated with BioCleanse are not significantly different from those of untreated controls. Clinical Relevance This laboratory study compares the biomechanical properties of chemically treated allografts, which are currently being used in anterior cruciate ligament reconstruction, with those of nontreated fresh‐frozen allografts.
Rotator Cuff Repair Using an Acellular Dermal Matrix Graft: An In Vivo Study in a Canine Model
Purpose Large rotator cuff tears present a challenge to orthopaedic surgeons. Because tissue may be insufficient or of inadequate quality to undergo repair, a variety of materials have been used as adjuncts. Human dermal tissue may be processed to render it acellular, and thus less immunogenic, but with the extracellular matrix left intact, creating a collagen scaffold with favorable characteristics. Because of these traits, use in rotator cuff repair was proposed. Methods A canine model for a full‐thickness infraspinatus tendon tear was used. Tendon was excised from the bony interface to the myotendinous junction, and a human acellular dermal matrix graft (experimental) or the autologous excised tendon (control) was used to bridge the defect. Animals were sacrificed, and shoulders were evaluated histologically and biomechanically. Results At time 0, strength of control and experimental repairs was similar. At 6 weeks, the strength of the experimental repair was half that of the control side. Strength of control specimens remained the same at 6 and 12 weeks, but by 12 weeks, the strength of the experimental repair was equal to that of the control. Histologically, cells infiltrated the control and experimental specimens by 6 weeks; chronic inflammation was consistent with surgery and repair. At 6 months, control and experimental specimens mimicked normal tendon structure grossly and histologically. Conclusions Use of human acellular dermal matrix as a patch is a viable option in this model of large rotator cuff defects. Within 6 weeks, histologic evidence of native cell infiltration and neotendon development was observed. Within 12 weeks, the strength of the dermal matrix graft repair was equivalent to that of autologous tendon. At 6 months, control and graft specimens mimicked normal tendon structure grossly and histologically. Clinical Relevance This study provides in vivo animal data to support the use of this acellular dermal matrix graft for repair of full‐thickness rotator cuff defects. Additional studies are indicated to determine the role of this material in the treatment of humans with rotator cuff tears.
Development of a Biologic Prosthetic Composite for Cartilage Repair
Time Dependent Variations in Biomechanical Properties of Cadaveric Fascia, Porcine Dermis, Porcine Small Intestine Submucosa, Polypropylene Mesh and Autologous Fascia in the Rabbit Model: Implications for Sling Surgery
The supraspinatus tendon is frequently involved in rotator cuff tears. It has been suggested that joint position affects the structural mechanics of the tendon–bone complex. The purpose of this study was to determine regional variations in structural properties of the supraspinatus tendon in two glenohumeral positions. Supraspinatus tendons from 17 fresh frozen cadavers were divided into three strips of equal width and tested with a material-testing machine. The arm orientation was either in hanging position or 60 degrees glenohumeral abduction corresponding to 90 degrees arm abduction assuming 30 degrees scapular rotation. Tensile force, tendon elongation and failure mode were recorded. Overall, there was no significant difference in structural properties between hanging arm position and 60 degrees of glenohumeral abduction (p>0.05). However, the mean ultimate load (385 N, SD 56 N) and mean ultimate stress (14 MPa, SD 3 MPa) of the anterior tendon section with the arm in glenohumeral abduction were lower in 60 degrees abduction than in the hanging arm position (611 N, SD 276 N; 24 MPa, SD 10 MPa). In hanging arm position, the anterior tendon portion had a significantly greater ultimate load and stiffness than the middle and posterior portions (p<0.05). The regional variation in structural properties substantiates the clinical finding that rotator cuff ruptures easily extend posteriorly. Our study suggests that glenohumeral abduction reduces the failure strength of the supraspinatus tendon, specifically of its anterior portion. In our study, the maximum load of the anterior portion was substantially higher than predicted maximum loads transmitted physiologically through the entire tendon.
Comparison of Mechanical Properties of Various Suture Repair Techniques in a Partially Lacerated Tendon
The technique of surgical repair for zone two flexor tendon injuries has been debated extensively throughout the years, yet adhesion formation, suture rupture, and suture locking on the pulley edge remain possible consequences of a poor repair. The partially lacerated tendon is especially challenging to treat since there can be justification for not intervening surgically. In a partial laceration canine model we measured failure load and suture gap formation for tendons repaired with the Lee, modified four-strand Savage, Kessler, modified Kessler, and Augmented Becker core suture techniques and with a simple running peripheral suture. The modified Kessler (106.3 N, SD 18.8 N) and modified Savage (108.2 N, SD 19.9 N) repair techniques had a significantly higher failure load than the Lee (85.0 N, SD 20.6 N) suture method p<0.05, while there were no differences among the other techniques. There were no significant differences in resistance to gap formation among the repair techniques, with the mean values ranging from 38.9 N/mm (SD 15.7 N/mm) using the simple running suture to 53.2 N/mm (SD 25.8 N/mm) with the Kessler repair. The mean load to produce a 1.5 mm repair site gap ranged from 71.1 N (SD 21.5 N) in the Lee repair to 91.3 N (SD 22.2 N) in the Augmented Becker repair although there were no significant differences among repair methods. All repair methods were much weaker than tendons left unrepaired (184.7 N, SD 41.3 N). [S0148-0731(00)00706-8]