Aims The aim of this study was to evaluate two hypotheses. First, that disruption of posterior bundle of the medial collateral ligament (PMCL) has to occur for the elbow to subluxate in cases of posteromedial rotatory instability (PMRI) and second, that ulnohumeral contact pressures increase after disruption of the PMCL. Materials and Methods Six human cadaveric elbows were prepared on a custom-designed apparatus which allowed muscle loading and passive elbow motion under gravitational varus. Joint contact pressures were measured sequentially in the intact elbow (INTACT), followed by an anteromedial subtype two coronoid fracture (COR), a lateral collateral ligament (LCL) tear (COR + LCL), and a PMCL tear (COR + LCL + PMCL). Results There was no subluxation or joint incongruity in the INTACT, COR, and COR + LCL specimens. All specimens in the COR + LCL + PMCL group subluxated under gravity-varus loads. The mean articular contact pressure of the COR + LCL group was significantly higher than those in the INTACT and the COR groups. The mean articular contact pressure of the COR + LCL + PMCL group was significantly higher than that of the INTACT group, but not higher than that of the COR + LCL group. Conclusion In the presence of an anteromedial fracture and disruption of the LCL, the posterior bundle of the MCL has to be disrupted for gross subluxation of the elbow to occur. However, elevated joint contact pressures are seen after an anteromedial fracture and LCL disruption even in the absence of such subluxation. Cite this article: Bone Joint J 2018;100-B:1060–5.
Healing of Canine Tendon in Zones Subjected to Different Mechanical Forces
The effect of external force environment on the healing of a partial thickness injury to canine flexor tendon was studied. A 50% laceration was made in either the fibrocartilaginous (compressive) zone or in the tendinous (tensile) zone of canine flexor digitorum profundus tendons. After three or six weeks, the tendons were harvested. An optical method for determining zone-specific material properties showed that, in response to injury, the structural stiffness decreased in the tensile zone of the tendon but increased in the compressive zone. The mechanical properties and failure mechanism of canine tendon and their changes in response to injury vary according to tendon zone, and differences in the healing process in mechanically specialised zones of the flexor tendon are discussed.
Ten normal ring fingers from ten donors were used to determine the effect of flexor tendon repair on the gliding resistance between the tendon and the A2 pulley. Gliding resistance was measured for the intact FDP tendon and for the same tendon after it was cut transversely and repaired with a 4/0 Ticron core suture and a 6/0 running epitendinous nylon suture. After repair, the gliding pattern of the tendon through the A2 pulley changed significantly. The resistance and the friction coefficient were approximately doubled ( P<0.005).
MEASUREMENT OF INTRINSIC ARTICULAR JOINT STABILITY
Concavity-compression is an important mechanism for keeping a joint centered despite a large range of motion. The purpose of this study was to explain how the results of a test measuring the joint intrinsic stability can be interpreted and related to joint architecture. As an example, the method was demonstrated for the glenohumeral joint although the versatility allows any articulating joint, whether natural or prosthetic, to be analyzed. The initial slope from the central point was relatively steep, indicating a large resistance to translation. The peak translation force occurred within the first 5 mm of displacement for the glenohumeral joint, indicating a high congruence between the humerus and glenoid surfaces. Stability ratio, calculated as the maximum translation force divided by the applied joint compressive force, makes it possible to compare the stabilizing effect under different compressive loads for different anatomical directions. In hanging arm position, the joint stability ratio ranged from 30.5% to 60.1%. Finally, the effective depth of the concavity and the maximum range of joint translation can be measured by completely dislocating the joint. For the glenohumeral specimen, the smallest glenoid concavity depth, 3.8 mm, occurred in the anterior direction. The joint translation limit was smallest in the anterior-posterior direction (28.0 mm). The methodology presented in this study will allow consistent testing parameters between different trials, easily allowing parametric studies to gain a more complete understanding of articular joints.