Back to Authors

Dydak, Ulrike

https://orcid.org/0000-0003-1852-7110

Mayo Clinic

Purdue University West Lafayette

Citations 2

Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, Martin , Andronesi, Ovidiu C. , Barker, Peter B. , Bartha, Robert , Bizzi, Alberto , Bolan, Patrick J. , Cudalbu, Cristina , Dydak, Ulrike , Emir, Uzay E. , González, R. Gilberto , Gruber, Stephan , Gupta, Rakesh K. , Henning, A , Hetherington, Hoby P. , Hüppi, Petra S. , Hurd, Ralph E. , Kantarci, Kejal , Kauppinen, Risto A. , Klomp, Dennis W. J. , Kreis, Roland , Kruiskamp, Marijn J., Leach, Martin O. , Lin, Alexander , Luijten, Peter R. , Marjańska, Małgorzata , Meyerhoff, Dieter J. , Mountford, Carolyn E. , Mullins, Paul G. , Murdoch, James B. , Nelson, Sarah J. , Noeske, Ralph , Öz, Gülin , Pan, Julie W., Poptani, Harish , Posse, Stefan , Ratai, Eva‐Maria , Salibi, Nouha , Scheenen, Tom W. J. , Soher, Brian J. , Tkáč, Ivan , Vigneron, Daniel B. , Howe, Franklyn A. , Choi, In‐Young , Kreis, Roland , Maudsley, Andrew A , Howe, Franklyn A , Öz, Gülin , Marjańska, Małgorzata , Kantarci, Kejal , Brindle, Kevin Michael , Choi, In‐Young, Gruetter, Rolf , Heerschap, Arend , Peet, Andrew C. , Smith, Ian C. P.

Magnetic Resonance in Medicine | March 28, 2019 | Volume: 82 | Issue: 2 | Pages: 527-550

10.1002/mrm.27742 Get It

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.
Reproducibility and effect of tissue composition on cerebellar γ‐aminobutyric acid (GABA) MRS in an elderly population
Long, Zaiyang , Dyke, Jonathan P. , Ma, Ruoyun, Huang, Chaorui , Louis, Elan D. , Dydak, Ulrike

NMR in Biomedicine | August 28, 2015 | Volume: 28 | Issue: 10 | Pages: 1315-1323

10.1002/nbm.3381 Get It

MRS provides a valuable tool for the non‐invasive detection of brain γ‐aminobutyric acid (GABA) in vivo. GABAergic dysfunction has been observed in the aging cerebellum. The study of cerebellar GABA changes is of considerable interest in understanding certain age‐related motor disorders. However, little is known about the reproducibility of GABA MRS in an aged population. Therefore, this study aimed to explore the feasibility and reproducibility of GABA MRS in the aged cerebellum at 3.0 T and to examine the effect of differing tissue composition on GABA measurements. MRI and 1H MRS examinations were performed on 10 healthy elderly volunteers (mean age, 75.2 ± 6.5 years) using a 3.0‐T Siemens Tim Trio scanner. Among them, five subjects were scanned twice to assess the short‐term reproducibility. The MEGA‐PRESS (Mescher–Garwood point‐resolved spectroscopy) J‐editing sequence was used for GABA detection in two volumes of interest (VOIs) in the left and right cerebellar dentate. MRS data processing and quantification were performed with LCModel 6.3‐0L using two separate basis sets, generated from density matrix simulations using published values for chemical shifts and J couplings. Raw metabolite levels from LCModel outputs were corrected for cerebrospinal fluid contamination and relaxation. GABA‐edited spectra yielded robust and stable GABA measurements with averaged intra‐individual coefficients of variation for corrected GABA+ between 4.0 ± 2.8% and 13.4 ± 6.3%, and inter‐individual coefficients of variation between 12.6% and 24.2%. In addition, there was a significant correlation between GABA+ obtained with the two LCModel basis sets. Overall, our results demonstrated the feasibility and reproducibility of cerebellar GABA‐edited MRS at 3.0 T in an elderly population. This information might be helpful for studies using this technique to study GABA changes in normal or diseased aging brain, e.g. for power calculations and the interpretation of longitudinal observations. Copyright © 2015 John Wiley & Sons, Ltd.