Back to Authors

Marjańska, Małgorzata

0000-0002-4727-2447

Mayo Clinic

Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, Minnesota, US.

Citations 4

Magnetic resonance spectroscopy in the rodent brain: Experts' consensus recommendations
Lanz, Bernard , Abaei, Alireza , Braissant, Olivier , Choi, In‐Young , Cudalbu, Cristina , Henry, Pierre‐Gilles , Kantarci, Kejal , Lutz, Norbert W. , Marjańska, Małgorzata , Mlynárik, Vladı́mir , Xin, Lijing , Valette, Julien , brain, the Experts' Working Group on Magnetic resonance spectroscopy in the rodent, Deelchand, Dinesh K. , Öz, Gülin , Tkáč, Ivan , Kara, Firat , Lee, Phil , Lutz, Norbert W , Marjańska, Małgorzata , Öz, Gülin , Kantarci, Kejal , Deelchand, Dinesh K , Gruetter, Rolf , Rasche, Volker , brain, the Experts' Working Group on Magnetic resonance spectroscopy in the rodent

NMR in Biomedicine | September 2, 2020 | Volume: 34 | Issue: 5 | Pages: No page available

10.1002/nbm.4325 Get It

In vivo MRS is a non‐invasive measurement technique used not only in humans, but also in animal models using high‐field magnets. MRS enables the measurement of metabolite concentrations as well as metabolic rates and their modifications in healthy animals and disease models. Such data open the way to a deeper understanding of the underlying biochemistry, related disturbances and mechanisms taking place during or prior to symptoms and tissue changes. In this work, we focus on the main preclinical 1H, 31P and 13C MRS approaches to study brain metabolism in rodent models, with the aim of providing general experts’ consensus recommendations (animal models, anesthesia, data acquisition protocols). An overview of the main practical differences in preclinical compared with clinical MRS studies is presented, as well as the additional biochemical information that can be obtained in animal models in terms of metabolite concentrations and metabolic flux measurements. The properties of high‐field preclinical MRS and the technical limitations are also described.
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, Martin , Andronesi, Ovidiu C. , Barker, Peter B. , Bartha, Robert , Bizzi, Alberto , Bolan, Patrick J. , Cudalbu, Cristina , Dydak, Ulrike , Emir, Uzay E. , González, R. Gilberto , Gruber, Stephan , Gupta, Rakesh K. , Henning, A , Hetherington, Hoby P. , Hüppi, Petra S. , Hurd, Ralph E. , Kantarci, Kejal , Kauppinen, Risto A. , Klomp, Dennis W. J. , Kreis, Roland , Kruiskamp, Marijn J., Leach, Martin O. , Lin, Alexander , Luijten, Peter R. , Marjańska, Małgorzata , Meyerhoff, Dieter J. , Mountford, Carolyn E. , Mullins, Paul G. , Murdoch, James B. , Nelson, Sarah J. , Noeske, Ralph , Öz, Gülin , Pan, Julie W., Poptani, Harish , Posse, Stefan , Ratai, Eva‐Maria , Salibi, Nouha , Scheenen, Tom W. J. , Soher, Brian J. , Tkáč, Ivan , Vigneron, Daniel B. , Howe, Franklyn A. , Choi, In‐Young , Kreis, Roland , Maudsley, Andrew A , Howe, Franklyn A , Öz, Gülin , Marjańska, Małgorzata , Kantarci, Kejal , Brindle, Kevin Michael , Choi, In‐Young, Gruetter, Rolf , Heerschap, Arend , Peet, Andrew C. , Smith, Ian C. P.

Magnetic Resonance in Medicine | March 28, 2019 | Volume: 82 | Issue: 2 | Pages: 527-550

10.1002/mrm.27742 Get It

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.
Magnetic Resonance Imaging of Alzheimer's Pathology in the Brains of Living Transgenic Mice: A New Tool in Alzheimer's Disease Research
Jack, Clifford R. , Marjańska, Małgorzata , Wengenack, Thomas M., Reyes, Denise A., Curran, Geoffrey L., Preboske, Gregory M., Poduslo, Joseph F., Garwood, Michael , Lin, Joseph , Jack, Clifford R , Marjańska, Małgorzata

The Neuroscientist | January 17, 2007 | Volume: 13 | Issue: 1 | Pages: 38-48

10.1177/1073858406295610 Get It

Alzheimer's disease (AD) is the most common cause of dementia in the elderly. Cardinal pathologic features of AD are amyloid plaques and neurofibrillary tangles, and most in the field believe that the initiating events ultimately leading to clinical AD center on disordered metabolism of amyloid beta protein. Mouse models of AD have been created by inserting one or more human mutations associated with disordered amyloid metabolism and that cause early onset familial AD into the mouse genome. Human-like amyloid plaque formation increases dramatically with age in these transgenic mice. Amyloid reduction in humans is a major therapeutic objective, and AD transgenic mice allow controlled study of this biology. Recent work has shown that amyloid plaques as small as 35 μm can be detected using in vivo magnetic resonance microimaging (MRMI) at high magnetic field (9.4 T). In addition, age-dependent changes in metabolite concentration analogous to those that have been identified in human AD patients can be detected in these transgenic mice using single-voxel 1 H magnetic resonance spectroscopy ( 1 H MRS) at high magnetic field. These MR-based techniques provide a new set of tools to the scientific community engaged in studying the biology of AD in transgenic models of the disease. For example, an obvious application is evaluating therapeutic modification of disease progression. Toward the end of this review, the authors include results from a pilot study demonstrating feasibility of using MRMI to detect therapeutic modification of plaque progression in AD transgenic mice.
Monitoring disease progression in transgenic mouse models of Alzheimer's disease with proton magnetic resonance spectroscopy
Marjańska, Małgorzata , Curran, Geoffrey L., Wengenack, Thomas M., Henry, Pierre‐Gilles , Bliss, Robin, Poduslo, Joseph F., Jack, Clifford R. , Uǧurbil, Kǎmil , Garwood, Michael , Jack, Clifford R , Marjańska, Małgorzata

Proceedings of the National Academy of Sciences | August 9, 2005 | Volume: 102 | Issue: 33 | Pages: 11906-11910

10.1073/pnas.0505513102 Get It

Currently no definitive biomarker of Alzheimer's disease (AD) is available, and this impedes both clinical diagnosis in humans and drug discovery in transgenic animal models. Proton magnetic resonance spectroscopy ( 1 H MRS) provides a noninvasive way to investigate in vivo neurochemical abnormalities. Each observable metabolite can potentially provide information about unique in vivo pathological processes at the molecular or cellular level. In this study, the age-dependent 1 H MRS profile of transgenic AD mice was compared to that of wild-type mice. Twenty-seven APP-PS1 mice (which coexpress mutated human presenilin 1 and amyloid-β precursor protein) and 30 wild-type mice age 66-904 days were examined, some repeatedly. A reduction in the levels of N -acetylaspartate and glutamate, compared with total creatine levels, was found in APP-PS1 mice with advancing age. The most striking finding was a dramatic increase in the concentration of myo -inositol with age in APP-PS1 mice, which was not observed in wild-type mice. The age-dependent neurochemical changes observed in APP-PS1 mice agree with results obtained from in vivo human MRS studies. Among the different transgenic mouse models of AD that have been studied with 1 H MRS, APP-PS1 mice seem to best match the neurochemical profile exhibited in human AD. 1 H MRS could serve as a sensitive in vivo surrogate indicator of therapeutic efficacy in trials of agents designed to reduce neurotoxicity due to microglial activation. Because of its noninvasive and repeatable nature, MRS in transgenic models of AD could substantially accelerate drug discovery for this disease.