Background:The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used to treat a number of bacterial infections. TMP/SMX concentrations in serum are conventionally monitored using high-performance liquid chromatography (HPLC) or liquid chromatography tandem mass spectrometry. These methods require laborious manual extraction techniques and relatively long sample analysis times, necessitating the development of a simple, high-throughput method. A simple, high-throughput method to measure TMP/SMX using ultra-fast solid-phase extraction (SPE)–tandem mass spectrometry has been developed.Methods:Calibration standards, quality control materials, and patient samples were precipitated with acetonitrile containing isotopically labeled internal standards. Samples were vortexed, centrifuged for 5 minutes at 2053g, and the resulting supernatant was diluted in aqueous mobile phase and injected onto the C18 SPE cartridge. MS/MS analysis was performed by electrospray ionization in positive ion mode at a rate of <20 seconds per sample. A 5-point linear 1/x calibration curve was used to calculate sample concentrations.Results:The intra-assay precision coefficients of variation were <6% and <7% for SMX and TMP, respectively, and <10% for both interassay precision coefficients of variation. Comparison studies using 50 patient and spiked serum samples showed r2values of 0.9890 and 0.9853 andy-intercept values of −1.918 and −1.357, respectively compared with the HPLC reference method. All data points were <±15% of the mean. Linearity [r2= 0.9952 (SMX) and 0.9954 (TMP)] was established from 12 to 400 mcg/mL with a detection limit of 0.47 mcg/mL, and 1.2–40 mcg/mL with a detection limit of 0.06 mcg/mL, for SMX and TMP, respectively. For either drug, no significant carryover was observed after samples at the upper limit of quantification. No interference was observed from any of the 77 drugs and respective metabolites tested.Conclusions:A high-throughput SPE–tandem mass spectrometry method for TMP/SMX quantification was developed. The <20 seconds analysis time is a significant improvement compared with traditional HPLC and liquid chromatography tandem mass spectrometry methods, without sacrificing analytical performance.
Comparison of Two Commercially Available Fentanyl Screening Immunoassays for Clinical Use
Abstract Background Fentanyl is a synthetic opioid associated with illicit drug use and overdose deaths. The SEFRIA Immunalysis (IAL) and ARK fentanyl assays are both FDA-cleared, open channel immunoassays for fentanyl detection in urine. However, limited data are available in the literature comparing these assays. The objective of this study was to perform a direct comparison of these two fentanyl immunoassays. Methods IAL and ARK fentanyl immunoassays were performed on a Roche Cobas e602 automated chemistry analyzer. Repeatability and total imprecision were compared by diluting fentanyl into urine at concentrations above, below, and at the manufacturers’ cutoffs of 1.0 ng/mL. Cross-reactivity was assessed for norfentanyl and the fentanyl analogs acetylfentanyl, acrylfentanyl, and furanylfentanyl. Concordance was assessed in 90 patient samples using liquid chromatography-tandem mass spectrometry (LC-MS/MS) as the gold standard. Results Repeatability varied from 11.4%–17.8% on the IAL assay and 2.8%–5.5% on the ARK assay. Total imprecision was 18.9%–40.7% on the IAL assay and 2.9%–6.4% on the ARK assay. Both assays cross-reacted with acetylfentanyl (∼100%), acrylfentanyl (∼100%), and furanylfentanyl (∼20%), but only the ARK assay cross-reacted with norfentanyl (∼3%). An admixture of 0.5 ng/mL fentanyl and 6 ng/mL norfentanyl produced a positive result on the ARK assay. Total concordance between IAL and ARK for 90 tested patient samples was 93% (kappa = 0.85). Relative to LC-MS/MS, the IAL assay had a concordance of 90% (kappa = 0.79) and the ARK assay had a concordance of 94% (kappa = 0.88). Including norfentanyl in the LC-MS/MS confirmation increased the concordance of the ARK to 96% (kappa = 0.90). Conclusions The ARK assay recognized the metabolite norfentanyl, demonstrated superior precision, and had better concordance with LC-MS/MS compared to the IAL assay.
Volumetric Microsampling of Capillary Blood Spot vs Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus and Cyclosporin A: Accuracy and Patient Satisfaction
Abstract Background Immunosuppressant therapeutic drug monitoring (TDM) usually requires outpatient travel to hospitals or phlebotomy sites for venous blood collection; however Mitra® Microsampling Device (MSD) sampling could allow self-collection and shipping of samples to a laboratory for analysis. This study examined the feasibility of using volumetric microsampling by MSD for TDM of tacrolimus (TaC) and cyclosporin A (CsA) in transplant patients, along with their feedback on the process. Methods MSD was used to collect TaC and CsA from venous (VB) or capillary (CB) blood. The MSDs were rehydrated, extracted, and analyzed using on-line solid phase extraction coupled to tandem mass spectrometry (SPE-MS/MS). We report an abbreviated method validation of the MSD including: accuracy, precision, linearity, carry-over, and stability using residual venous whole blood (VB) samples. Subsequent clinical validation compared serially collected MSD + CB against VB (200 µL) from transplant patients. Results Accuracy comparing VB vs. MSD+VB showed high clinical concordance (TaC = 89% and CsA = 98%). Inter- and intra-precision was ≤11.5 %CV for TaC and CsA. Samples were stable for up to 7 days at room temperature with an average difference of <10%. Clinical validation with MSD+CB correlated well with VB for CsA (slope = 0.95, r2 = 0.88, n = 47) and TaC (slope = 0.98, r2 = 0.82, n = 49). CB vs. VB gave concordance of 94% for CsA and 79% for TaC. A satisfaction survey showed 82% of patients preferred having the capillary collection option. Conclusion Transplant patients favored having the ability to collect capillary samples at home for TaC/CsA monitoring. Our results demonstrate good concordance between MSD+CB and VB for TaC and CsA TDM, but additional studies are warranted.
Urinary reference intervals for gadolinium in individuals without recent exposure to gadolinium-based contrast agents
AbstractBackgroundTrace‐element contamination of contemporary parenteral nutrition (PN) components exists in unknown quantities and, in combination with excessive amounts of certain trace elements provided in commercially available adult, pediatric, and neonatal multitrace‐element (MTE) products, could result in eventual accumulation and toxicity. This study aims to quantify trace‐element contamination in components used for PN compounding to further inform recommendations for MTE product reformulation and individualized trace‐element prescribing in PN.MethodsA total of 32 unique components (65 products) available for PN compounding were tested for manganese, chromium, selenium, zinc, and copper contamination, utilizing inductively coupled plasma mass spectrometry. Theoretical adult, pediatric, and neonatal PNs were formulated to assess the impact of macronutrient and micronutrient component doses on PN trace‐element contamination.ResultsTrace‐element contamination was detected in 24 (75%) components tested. Chromium and manganese were common, present in 65.6% and 51.5% of all components, respectively. Eight components did not contain detectable trace‐element contamination, most notably sterile water, concentrated dextrose, and lipid emulsion. Manganese contamination in theoretical adult, pediatric, and neonatal PN was 25.18, 9.92, and 1.37 µg, respectively. Chromium contamination was 4.85, 1.5, and 0.28 µg, respectively.ConclusionTrace‐element contamination was prevalent in components used to compound PN. Our findings support reformulation of adult, pediatric, and neonatal manufactured MTE products to eliminate chromium, decrease manganese, and supply full daily physiologic requirements of selenium, zinc, and copper. Future study is needed to assess the additional contamination that could occur through the compounding and storage processes.
Gadolinium-based contrast agents: A clinically significant analytical interference in inductively coupled plasma mass spectrometry elemental analysis
Background Gadolinium-based contrast agents (GBCAs) have been used in magnetic resonance imaging for the past 30 years, where they have significantly improved the effectiveness of imaging studies. However, the increased usage of gadolinium in the medical community has also resulted in unexpected interferences in other laboratory assays. This has been particularly the case in clinical elemental analysis using inductively coupled plasma mass spectrometry (ICP-MS). Methods By conducting ICP-MS interference experiments, we describe how gadolinium interferes with elemental analysis by space charge effect, double charge effect and the creation of polyatomic interferences. Additionally, by reviewing more than a year of reference laboratory data from our laboratory information system, we determined the number of elemental tests cancelled due to gadolinium interference. Results Interference experiments show that gadolinium normally found in GBCAs can interfere with heavy metals, platinum and selenium analysis of biological fluids using ICP-MS. Within one year, our institution’s metals laboratory had to cancel 42 selenium serum tests and 19 heavy metal urine panels due to potential interference caused by gadolinium. Conclusions GBCAs will continue to be utilized in hospitals around the world. However, clinical laboratories should be wary of potential interferences caused by GBCAs. Relevant interferences include space charge effect, double charge interference, and the formation of polyatomic interferences caused by gadolinium. These interferences can negatively affect patient care by resulting in cancelled laboratory tests and causing patients to have blood redrawn and analysed at a later date leading to delays in their diagnosis/treatment.
The clinical utility of ganciclovir therapeutic drug monitoring (TDM) is unknown. We retrospectively analyzed adult patients treated for cytomegalovirus (CMV) infection with ganciclovir with TDM between 2005 and 2015.