Back to Authors

Bjergum, Matthew W.

Mayo Clinic

Mayo Clinic

Citations 5

B-166 Effect of Urine Adulteration on Quantifying both Delta 8- and Delta 9-carboxy tetrahydrocannabinol using a New UPLC-tandem Mass Spectrometry Method
Chai, Yifeng , Bjergum, Matthew W., Lahr, Richard G. , Tufariello, Jessica A., Ladwig, Paula M. , Langman, L, Jannetto, Paul J. , Maus, Anthony

Clinical Chemistry | September 27, 2023 | Volume: 69 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvad097.499 Get It

Abstract Background The legality and use of marijuana is a controversial topic. With increased prevalence of usage, cannabis detection for legal, medical, and workforce drug testing is on the rise. LC-MS/MS quantification of delta 9-carboxy tetrahydrocannabinol (delta 9-THC-COOH) in urine is accepted as the standard to detect marijuana use. One challenge faced by testing laboratories has been identifying adulterated samples. Many products/reagents can be used to manipulate the urine to avoid positive drug testing results. In this study, we developed a dilute-and-shoot strategy to separate and quantify both the delta 8- and 9-THC-COOH in urine samples and tested the effects of adulteration using a combination of nitrite and/or acids which can be used to mask cannabinoid use. Methods Five authentic delta 8- and 9-THC-COOH positive specimens, and one spiked sample were treated with strong acids (1N HCL or 10% TCA), 500 µg/mL nitrite, or a combination. After hydrolysis with sodium hydroxide, the analytes were quantified using a 6495 Mass Spectrometer coupled to a StreamSelect LC system (Agilent). LC separation was performed with a CORTECS T3 column utilizing a shallow gradient. In addition, twelve urine specimens with varying concentrations of delta 8- and 9-THC-COOH were treated with nitrite and screened using a delta 9-THC-COOH immunoassay on the Roche Cobas C501 and analyzed by LC-MS/MS. Results Nitrite did not change the physical appearance or the pH of the urine samples. Strong acid treatment also did not alter the appearance but did drop the urine pH ≤2. Pre-treated specimens with 1N HCL, 10% TCA, or 500 µg/mL of nitrite did not affect the delta 8- and 9-THC-COOH concentrations up to 6 days (refrigerated); however, specimens treated with strong acid combined with 500 µg/mL of nitrite for 30 min made both analytes undetectable. Additional experiments confirmed that 0.5 and 1 mol/L of nitrite lowered the concentration of all analytes, including internal standard, to undetectable levels in 48 h. Twelve additional specimens were collected, 3 with delta 8-THC-COOH, 3 with delta 9-THC-COOH, and 6 with both. All 12 samples screened positive using the Roche immunoassay and were quantified using the LC-MS/MS method. After treatment with 0.5 mol/L of nitrite, 10 of the 12 samples were negative using the immunoassay, but 2 samples remained positive. However, all nitrite treated specimens were negative (<LLOQ) using the LC-MS/MS method and the internal standard was eliminated. Later experiments confirmed that the delta 8- and 9-THC-COOH could be eliminated with as little as 0.1 mol/L nitrite for 30 min. Conclusion The unique dilute-and-shoot method can separate and quantify delta 8- and 9-THC-COOH. In addition, high concentrations of nitrite were shown to degrade both analytes along with the isotopically labeled internal standard. As a result, labs can distinguish true negative delta 8- and 9-THC-COOH (no analyte peaks) from nitrite adulterated specimens since the adulterated samples have no peaks for both the analytes and internal standard. A limitation of the study is that only sodium nitrite was tested. Other adulterants, such as potassium nitrite, pyridinium chlorochromate, peroxide etc. require further investigation.
Adequacy of cefepime concentrations in the early phase of critical illness: A case for precision pharmacotherapy
Frazee, Erin N. , Chang, Jack , Bjergum, Matthew W., Gajić, Ognjen, Jannetto, Paul J. , Mara, Kristin C. , Meade, Laurie A., Vollmer, Kathryn J., Scheetz, Marc H. , Group, For the BLOOM Study, Frazee, Erin N , Scheetz, Marc H , Mara, Kristin C , Gajic, Ognjen , Rule, Andrew D. , Group, For the BLOOM Study

Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy | January 17, 2023 | Volume: 43 | Issue: 11 | Pages: 1112-1120

10.1002/phar.2766 Get It

AbstractStudy ObjectiveIn critically ill patients, adequacy of early antibiotic exposure has been incompletely evaluated. This study characterized factors associated with inadequate cefepime exposure in the first 24 h of critical illness.DesignProspective cohort study.SettingAcademic Medical Center.PatientsCritically ill adults treated with cefepime. Patients with acute kidney injury or treated with kidney replacement therapy or extracorporeal membrane oxygenation were excluded.InterventionNone.MeasurementsA nonlinear mixed‐effects pharmacokinetic (PK) model was developed to estimate cefepime concentrations for each patient over time. The percentage of time the free drug concentration exceeded 8 mg/L during the first 24 h of therapy was calculated (%ƒT>8; appropriate for the susceptible breakpoint for Pseudomonas aeruginosa). Factors predictive of low %ƒT>8 were explored with multivariable regression.Main ResultsIn the 100 included patients, a one‐compartment PK model was developed with first‐order elimination with covariates for weight and estimated glomerular filtration rate based on creatinine and cystatin C (eGFRSCr‐CysC). The median (interquartile range) %ƒT>8 for cefepime in the first 24 h of therapy based on this model was 85% (66%, 100%). Less than 100% ƒT>8 during first 24 h of therapy occurred in 70 (70%) individuals. Lower Sequential Organ Failure Assessment score (p = 0.032) and higher eGFRSCr‐CysC (p < 0.001) predicted a lower %ƒT>8. Central nervous system infection source was protective (i.e., associated with a higher %ƒT>8; p = 0.008).ConclusionsDuring early critical illness, cefepime concentrations were inadequate in a significant proportion of patients. Antimicrobial optimization is needed to improve the precision of pharmacotherapy in the critically ill patients.
Stability and Validation of a High-Throughput LC-MS/MS Method for the Quantification of Cefepime, Meropenem, and Piperacillin and Tazobactam in Serum
Bjergum, Matthew W., Frazee, Erin N. , Scheetz, Marc H. , Jannetto, Paul J. , Scheetz, Marc H , Rule, Andrew D.

The Journal of Applied Laboratory Medicine | April 5, 2021 | Volume: 6 | Issue: 5 | Pages: 1202-1212

10.1093/jalm/jfab036 Get It

Abstract Background The class of antibiotics known as β-lactams are a commonly used due to their effectiveness and safety. Therapeutic drug monitoring has been proposed but requires an accurate assay along with well-characterized preanalytic stability, as β-lactams are known to be relatively unstable. Methods A high-throughput LC-MS/MS assay validation and stability study was performed for cefepime, meropenem, and piperacillin and tazobactam in serum. Patient samples, standards, and QCs were crashed with acetonitrile containing internal standard. Following centrifugation, an aliquot of the supernatant was diluted with clinical laboratory reagent water and analyzed by LC-MS/MS. Results The assay showed linearity between 0.5 and 60 µg/mL for each analyte. The intra- and interassay reproducibility at 3 different concentrations (approximately 2, 25, and 40 µg/mL) was &lt;5% for each analyte. Accuracy studies for each analyte were compared using linear regression and demonstrated: slope = 1.0 ± 0.1; r2 ≥ 0.980; and y intercept 95% CI that included zero. Minimal ion suppression or enhancement was observed, and no significant carryover was observed up to 500 µg/mL of each analyte. Stability studies demonstrated significant loss in serum for each analyte at ambient and refrigerated temperatures (2–8 °C) and at −20 °C over days or weeks. In contrast, when stored at −80 °C, no significant loss was observed. Conclusions The LC-MS/MS assay showed acceptable performance characteristics for quantitation of β-lactams. With well-characterized stability, this assay can be used with residual specimens for pharmacokinetic modeling, which may lead to individualized dosing and improved patient care.
46: Population Pharmacokinetic Evaluation of Cefepime in Critically Ill Adults
Barreto, Erin, Bjergum, Matthew W., Vollmer, Kathryn J., Meade, Laurie, Fogelson, Lindsay A., Jannetto, Paul J. , Frazee, Erin N. , Scheetz, Marc H. , Mara, Kristin C. , Gajic, Ognjen , O’Horo, John C. , Reid, Joel M. , Rule, Andrew D.

Critical Care Medicine | December 18, 2020 | Volume: 49 | Issue: 1 | Pages: 24-24

10.1097/01.ccm.0000726212.71169.16 Get It

Quantification of Serum Sulfamethoxazole and Trimethoprim by Ultra-fast Solid-Phase Extraction–Tandem Mass Spectrometry
Fatica, Erica M. , Gaffron, Christopher, Bjergum, Matthew W., Langman, Loralie J., Jannetto, Paul J. , Fatica, Erica, Faber, Jennifer , Bjergum, Matthew, Langman, Loralie, Jannetto, Paul, Faber, Jennifer

Therapeutic Drug Monitoring | July 23, 2020 | Volume: 42 | Issue: 5 | Pages: 724-732

10.1097/ftd.0000000000000785 Get It

Background:The combination of trimethoprim (TMP) and sulfamethoxazole (SMX) is used to treat a number of bacterial infections. TMP/SMX concentrations in serum are conventionally monitored using high-performance liquid chromatography (HPLC) or liquid chromatography tandem mass spectrometry. These methods require laborious manual extraction techniques and relatively long sample analysis times, necessitating the development of a simple, high-throughput method. A simple, high-throughput method to measure TMP/SMX using ultra-fast solid-phase extraction (SPE)–tandem mass spectrometry has been developed.Methods:Calibration standards, quality control materials, and patient samples were precipitated with acetonitrile containing isotopically labeled internal standards. Samples were vortexed, centrifuged for 5 minutes at 2053g, and the resulting supernatant was diluted in aqueous mobile phase and injected onto the C18 SPE cartridge. MS/MS analysis was performed by electrospray ionization in positive ion mode at a rate of <20 seconds per sample. A 5-point linear 1/x calibration curve was used to calculate sample concentrations.Results:The intra-assay precision coefficients of variation were <6% and <7% for SMX and TMP, respectively, and <10% for both interassay precision coefficients of variation. Comparison studies using 50 patient and spiked serum samples showed r2values of 0.9890 and 0.9853 andy-intercept values of −1.918 and −1.357, respectively compared with the HPLC reference method. All data points were <±15% of the mean. Linearity [r2= 0.9952 (SMX) and 0.9954 (TMP)] was established from 12 to 400 mcg/mL with a detection limit of 0.47 mcg/mL, and 1.2–40 mcg/mL with a detection limit of 0.06 mcg/mL, for SMX and TMP, respectively. For either drug, no significant carryover was observed after samples at the upper limit of quantification. No interference was observed from any of the 77 drugs and respective metabolites tested.Conclusions:A high-throughput SPE–tandem mass spectrometry method for TMP/SMX quantification was developed. The <20 seconds analysis time is a significant improvement compared with traditional HPLC and liquid chromatography tandem mass spectrometry methods, without sacrificing analytical performance.