Abstract Background Drugs use during pregnancy is a major social and medical issue, which may lead to significant pre- and post-natal complications, such as preterm birth and newborn mortality. Exposed newborns may have long-term behavioral, cognitive, and developmental problems. Accurate detection of in utero drug exposure is crucial for timely medical intervention for the newborn and the mother. Meconium is the ‘gold standard' matrix for detection of drugs in newborn which reflects drug exposure during pregnancy. This study aims to develop and optimize a clinical assay for simultaneous screening of 21 drugs in meconium using a custom biochip array. Methods Custom biochip array (Randox Laboratories Ltd.) included 21 discrete test regions (DTRs) for amphetamine, methamphetamine, opioids/opiates (targeting morphine, oxymorphone, oxycodone, hydrocodone, 6-monoacetyl morphine, tramadol, buprenorphine, fentanyl, and methadone), phencyclidine (PCP), cocaine (targeting benzoylecgonine), benzodiazepines (targeting oxazepam, lorazepam, and clonazepam), zolpidem, barbiturates (targeting phenobarbital), ethyl glucuronide, methylphenidate, and marijuana metabolite (targeting Delta-9-Carboxy-Tetrahydrocannabinol [THC-COOH]). Patient samples were obtained from the residual meconium samples that had been previously used for other tests. Blank meconium samples were spiked at in-house cutoff, negative and positive assay control levels. All samples were extracted in specimen diluent using Biotage® Lysera and centrifuged. The supernatant was analyzed on a fully automated Randox Evidence+® Analyzer. A robotic arm pipetted 60 µL sample on to a biochip and then the analyzer performed a competitive chemiluminescent immunoassay. The results were generated as relative light units (RLUs). Results The sample results were determined to be “positive” or “negative” based on average RLU of cutoff controls for each analyte on an assay. The intra-assay (CV ≤ 15%) and inter-assay (CV ≤ 18%) precision was 100% agreement for positive and negative controls and there was no observed carryover for any of the analytes. The sample recovery was excellent with minimal to no matrix suppression for all analytes. Accuracy was performed by comparing spiked analyte results from Randox Evidence+® Analyzer with the expected results and all the spiked samples matched (positive or negative). When authentic patient or spiked results were compared with external laboratory test results, some discordant results were obtained. However, the discrepancies could be explained based on the different cutoffs (e.g., the Randox assay had lower cutoffs) or the known assay cross reactivities within the analytes of same class. These deviations did not affect clinical utility of the assay. Conclusions We validated a novel and simple qualitative chemiluminescent immunoassay in meconium using a custom biochip array. Unlike other routine screening/ELISA methods, which require separate assays for detection of similar drug targets, the custom biochip array offers a convenient, rapid and efficient method that utilizes only a single sample preparation for the screening of all 21 drug targets. Therefore, this technology has potential to be utilized as high-throughput screening assay. Like all qualitative assays, the limitation of this test is that all positive results will need to be assessed quantitatively for a definitive interpretation.
B-166 Effect of Urine Adulteration on Quantifying both Delta 8- and Delta 9-carboxy tetrahydrocannabinol using a New UPLC-tandem Mass Spectrometry Method
Abstract Background The legality and use of marijuana is a controversial topic. With increased prevalence of usage, cannabis detection for legal, medical, and workforce drug testing is on the rise. LC-MS/MS quantification of delta 9-carboxy tetrahydrocannabinol (delta 9-THC-COOH) in urine is accepted as the standard to detect marijuana use. One challenge faced by testing laboratories has been identifying adulterated samples. Many products/reagents can be used to manipulate the urine to avoid positive drug testing results. In this study, we developed a dilute-and-shoot strategy to separate and quantify both the delta 8- and 9-THC-COOH in urine samples and tested the effects of adulteration using a combination of nitrite and/or acids which can be used to mask cannabinoid use. Methods Five authentic delta 8- and 9-THC-COOH positive specimens, and one spiked sample were treated with strong acids (1N HCL or 10% TCA), 500 µg/mL nitrite, or a combination. After hydrolysis with sodium hydroxide, the analytes were quantified using a 6495 Mass Spectrometer coupled to a StreamSelect LC system (Agilent). LC separation was performed with a CORTECS T3 column utilizing a shallow gradient. In addition, twelve urine specimens with varying concentrations of delta 8- and 9-THC-COOH were treated with nitrite and screened using a delta 9-THC-COOH immunoassay on the Roche Cobas C501 and analyzed by LC-MS/MS. Results Nitrite did not change the physical appearance or the pH of the urine samples. Strong acid treatment also did not alter the appearance but did drop the urine pH ≤2. Pre-treated specimens with 1N HCL, 10% TCA, or 500 µg/mL of nitrite did not affect the delta 8- and 9-THC-COOH concentrations up to 6 days (refrigerated); however, specimens treated with strong acid combined with 500 µg/mL of nitrite for 30 min made both analytes undetectable. Additional experiments confirmed that 0.5 and 1 mol/L of nitrite lowered the concentration of all analytes, including internal standard, to undetectable levels in 48 h. Twelve additional specimens were collected, 3 with delta 8-THC-COOH, 3 with delta 9-THC-COOH, and 6 with both. All 12 samples screened positive using the Roche immunoassay and were quantified using the LC-MS/MS method. After treatment with 0.5 mol/L of nitrite, 10 of the 12 samples were negative using the immunoassay, but 2 samples remained positive. However, all nitrite treated specimens were negative (<LLOQ) using the LC-MS/MS method and the internal standard was eliminated. Later experiments confirmed that the delta 8- and 9-THC-COOH could be eliminated with as little as 0.1 mol/L nitrite for 30 min. Conclusion The unique dilute-and-shoot method can separate and quantify delta 8- and 9-THC-COOH. In addition, high concentrations of nitrite were shown to degrade both analytes along with the isotopically labeled internal standard. As a result, labs can distinguish true negative delta 8- and 9-THC-COOH (no analyte peaks) from nitrite adulterated specimens since the adulterated samples have no peaks for both the analytes and internal standard. A limitation of the study is that only sodium nitrite was tested. Other adulterants, such as potassium nitrite, pyridinium chlorochromate, peroxide etc. require further investigation.
Lack of Influence by CYP3A4 and CYP3A5 Genotypes on Pain Relief by Hydrocodone in Postoperative Cesarean Section Pain Management
AbstractBackgroundGenetic polymorphisms of cytochrome P450 are contributors to variability in individual response to drugs. Within the P450 family, CYP2D6 is responsible for metabolizing hydrocodone, a widely prescribed opioid for pain management. Alternatively, CYP3A4 and CYP3A5 can form norhydrocodone and dihydrocodeine. We have previously found that in a postcesarean section cohort, the rate of hydromorphone formation was dependent on the genotype of CYP2D6 and that plasma hydromorphone, not hydrocodone, was predictive of pain relief.MethodBlood was obtained from a postcesarean cohort that were surveyed for pain response and common side effects. Plasma samples were genotyped for CYP3A4/5, and their hydrocodone concentrations were measured by LC-MS. R statistical software was used to check for differences in the outcomes due to CYP3A4/5 and CYP2D6, and a multivariate regression model was fit to determine factors associated with pain score.ResultsTwo-way ANOVA between CYP3A4/A5 and CYP2D6 phenotypes revealed that the former variants did not have a statistical significance on the outcomes, and only CYP2D6 phenotypes had a significant effect on total dosage (P = 0.041). Furthermore, a 3-way ANOVA analysis showed that CYP2D6 (P = 0.036) had a predictive effect on plasma hydromorphone concentrations, and CYP3A4/A5 did not have any effect on the measured outcomes.ConclusionsWith respect to total dosages in a cesarean section population, these results confirm that CYP2D6 phenotypes are predictors for plasma hydromorphone concentration and pain relief, but CYP3A4/A5 phenotypes have no influence on pain relief or on side effects.