Back to Authors

Mbughuni, Michael M.

Mayo Clinic

Minneapolis VA Health Care System

Citations 4

Corrigendum to: Comparison of Five Common Analyzers in the Measurement of Chemistry Analytes in an Authentic Cohort of Body Fluid Specimens
Block, Darci R , Cotten, Steven W. , Franke, Deanna, Mbughuni, Michael M.

American Journal of Clinical Pathology | March 17, 2022 | Volume: 158 | Issue: 1 | Pages: 157-157

10.1093/ajcp/aqac038 Get It

Comparison of Five Common Analyzers in the Measurement of Chemistry Analytes in an Authentic Cohort of Body Fluid Specimens
Block, Darci R , Cotten, Steven W. , Franke, Deanna, Mbughuni, Michael M.

American Journal of Clinical Pathology | December 6, 2021 | Volume: 158 | Issue: 1 | Pages: 47-61

10.1093/ajcp/aqab218 Get It

Abstract Objectives Interpretation of body fluid (BF) results is based on published studies and clinical guidelines. The aim of this study is to determine whether the assays from five common commercial vendors produce similar results in BFs for 12 analytes in a BF cohort. Methods BFs (n = 25) and serum (n = 5) were analyzed on five instruments (Roche cobas c501, Ortho 5600, Beckman AU5800 and DXI800, Siemens Vista 1500, and Abbott Architect c8000) to measure albumin, amylase, total bilirubin, cholesterol, creatinine, glucose, lactate dehydrogenase (LDH), lipase, total protein, triglycerides, urea nitrogen, and carcinoembryonic antigen. Deming regression and Bland-Altman analysis were used for method comparison to Roche. Results Results were significantly different from Roche for LDH and lipase on Ortho and lipase on Siemens but similar for both BFs and serum. BF differences were larger than serum differences when measuring creatinine, glucose, and urea nitrogen on Ortho and glucose on Siemens. Conclusions Five instruments used to perform BF testing produce results that are not significantly different except for lipase and LDH measurements. Bias of similar magnitude observed in both BF and serum should not affect interpretation. Further investigations into Ortho and Siemens measuring glucose and Ortho measuring creatinine and urea nitrogen are warranted.
Volumetric Microsampling of Capillary Blood Spot vs Whole Blood Sampling for Therapeutic Drug Monitoring of Tacrolimus and Cyclosporin A: Accuracy and Patient Satisfaction
Mbughuni, Michael M., Stevens, Maria , Langman, Loralie J., Kudva, Yogish C. , Dean, Patrick G. , Jannetto, Paul J. , Stevens, Maria A, Sánchez, William

The Journal of Applied Laboratory Medicine | January 26, 2020 | Volume: 5 | Issue: 3 | Pages: 516-530

10.1093/jalm/jfaa005 Get It

Abstract Background Immunosuppressant therapeutic drug monitoring (TDM) usually requires outpatient travel to hospitals or phlebotomy sites for venous blood collection; however Mitra® Microsampling Device (MSD) sampling could allow self-collection and shipping of samples to a laboratory for analysis. This study examined the feasibility of using volumetric microsampling by MSD for TDM of tacrolimus (TaC) and cyclosporin A (CsA) in transplant patients, along with their feedback on the process. Methods MSD was used to collect TaC and CsA from venous (VB) or capillary (CB) blood. The MSDs were rehydrated, extracted, and analyzed using on-line solid phase extraction coupled to tandem mass spectrometry (SPE-MS/MS). We report an abbreviated method validation of the MSD including: accuracy, precision, linearity, carry-over, and stability using residual venous whole blood (VB) samples. Subsequent clinical validation compared serially collected MSD + CB against VB (200 µL) from transplant patients. Results Accuracy comparing VB vs. MSD+VB showed high clinical concordance (TaC = 89% and CsA = 98%). Inter- and intra-precision was ≤11.5 %CV for TaC and CsA. Samples were stable for up to 7 days at room temperature with an average difference of <10%. Clinical validation with MSD+CB correlated well with VB for CsA (slope = 0.95, r2 = 0.88, n = 47) and TaC (slope = 0.98, r2 = 0.82, n = 49). CB vs. VB gave concordance of 94% for CsA and 79% for TaC. A satisfaction survey showed 82% of patients preferred having the capillary collection option. Conclusion Transplant patients favored having the ability to collect capillary samples at home for TaC/CsA monitoring. Our results demonstrate good concordance between MSD+CB and VB for TaC and CsA TDM, but additional studies are warranted.
Iatrogenic thyrotoxicosis and the role of therapeutic plasma exchange
Shah, Kabeer , Mbughuni, Michael M., Burgstaler, Edwin A. , Block, Darci R , Winters, Jeffrey L. , Shah, Kabeer K , Winters, Jeffrey L

Journal of Clinical Apheresis | March 20, 2017 | Volume: 32 | Issue: 6 | Pages: 579-583

10.1002/jca.21536 Get It

AbstractThyroid storm or severe thyrotoxicosis results from extreme thyroid hormone elevation. Therapy includes medical management to prevent hormone production, release, recycling, and peripheral conversion while stabilizing adrenergic tone. Thyroid dysfunction is the usual cause but it can be due to excessive thyroid hormone ingestion. Therapeutic plasma exchange (TPE) has been used to rapidly remove protein‐bound thyroid hormone. American Society for Apheresis guidelines make a weak recommendation to perform TPE in selected patients in the treatment of thyrotoxicosis based on low quality evidence. We present a case of excessive thyroid replacement hormone ingestion treated by TPE. The patient presented with the clinical picture of thyroid storm, including cardiovascular compromise and massively elevated total and free T3 (525 ng/dL, nl 80–200 ng/dL and 28 pg/mL, nl 2.0–3.5 11 pg/mL), which failed medical therapy. A single, one plasma volume TPE was performed. Both total and free T3 demonstrated substantial declines immediately after TPE with the patient's mental status returning to near‐normal. Thyroid hormone extraction efficiency and collection efficacy were calculated as 37.1% and 40.8%, respectively. Prior to discharge on day 6, the patient's compounding pharmacy indicated that a “bad batch” of bovine thyroid gland derived replacement hormone had been produced. TPE appears to be effective in removing protein bound thyroid hormone in extreme iatrogenic thyrotoxicosis.