Comparison of Brain Natriuretic Peptide Levels to Simultaneously Obtained Right Heart Hemodynamics in Stable Outpatients with Pulmonary Arterial Hypertension
Pulmonary arterial hypertension (PAH) is a progressive disease that requires validated biomarkers of disease severity. While PAH is defined hemodynamically by right heart catheterization (RHC), brain natriuretic peptide (BNP) is recommended by guidelines to assess disease status. Retrospectively collected data in 138 group 1 PAH patients were examined for the correlation of BNP levels to simultaneously obtained right heart catheterization (RHC). Patients were mostly Caucasian women, with functional class III symptoms, mean BNP of 406 ± 443 pg/mL, and an average right atrial pressure (RAP) of 9.9 ± 5.7 mm Hg and mean pulmonary artery pressure (mPAP) of 47.3 ± 14.7 mm Hg. Significant correlation was demonstrated between BNP and RAP (p = 0.021) and mPAP (p = 0.003). Additional correlation was seen with right heart size on echocardiography: right atrial (RAE; p = 0.04) and right ventricular enlargement (p = 0.03). An increased BNP level was an independent predictor of mortality (p < 0.0001), along with RAP (p = 0.039) and RAE (p = 0.018). Simultaneous collection of BNP at the time of RHC confirmed the correlation of BNP with right heart hemodynamics. The current results reinforce the use of BNP level as a continuous variable to assess disease severity in group 1 PAH.
Efficacy and safety of rivaroxaban compared to enoxaparin in treatment of cancer‐associated venous thromboembolism
AbstractBackgroundLow molecular weight heparin (LMWH) is the guideline‐endorsed treatment for cancer‐associated venous thromboembolism (cVTE). Study objectives were to compare the efficacy and safety of rivaroxaban and enoxaparin in cVTE.MethodsUsing a cohort study design, consecutive patients with cVTE (3/1/2013‐7/31/2016), enrolled in the Mayo Thrombophilia Clinic Direct Oral Anticoagulants Registry, were compared to contemporary cancer patients receiving enoxaparin. The cumulative incidence of venous thromboembolism (VTE) recurrence, major and clinically relevant non‐major bleeding, and survival were assessed at 3 and 12 months.ResultsNinety‐eight patients received rivaroxaban (51% female, mean age 63 ± 12 years) and 168 enoxaparin (34.5% female, mean age 62 ± 15 years). The most common cancers included gastrointestinal/pancreatic, genitourinary and hematologic cancers. More than half of patients had pulmonary emboli at presentation. More than half had metastases, and two‐thirds were receiving chemotherapy. At 3 months, there were no differences in VTE recurrence (rivaroxaban 1.0% vs enoxaparin 4.2%; P = .15), major bleeding (rivaroxaban 5.1% vs enoxaparin 3.6%; P = .55), or all‐cause mortality (rivaroxaban 4.1% vs enoxaparin 8.9%; P = .14). At 12 months, these outcomes did not differ by treatment strategy.ConclusionThe results of this “real‐world” experience with cVTE suggest that rivaroxaban may offer a safe and effective alternative to LMWH.
Feasibility, Safety, and Tolerance of Mesenchymal Stem Cell Therapy for Obstructive Chronic Lung Allograft Dysfunction
Abstract Feasibility, tolerance, and safety of intravenous infusions of allogeneic mesenchymal stem cell (MSC) therapy in lung transplant recipients with bronchiolitis obliterans syndrome (BOS) are not well established. MSCs were manufactured, cryopreserved, transported to our facility, thawed, and infused into nine recipients with moderate BOS (average drop in forced expiratory volume in 1 second was 56.8% ± 3.2% from post-transplant peak) who were refractory to standard therapy and not candidates for retransplant. Cells were viable and sterile prior to infusion. Patients received a single infusion of either 1 (n = 3), 2 (n = 3), or 4 (n = 3) million MSCs per kg. Patients were medically evaluated before; during; and at 24 hours, 1 week, and 1 month after infusion for evidence of infusion-related adverse events and tolerance of therapy. Vital signs, pulmonary function test results, Borg Dyspnea Index, and routine laboratory data were recorded. Vital signs and O2 saturation did not significantly change during or up to 2 hours after MSC infusion. There were no significant changes in gas exchange variables, pulmonary function test results, or laboratory values at 1, 7, and 30 days postinfusion compared with preinfusion values. Infusion of MSCs in patients with BOS was feasible, safe, and well tolerated and did not produce any significant adverse changes in clinical, functional, or laboratory variables during or up to 30 days after infusion. Manufacturing, transport, and administration of intravenous, allogeneic bone marrow-derived MSCs in doses from 1 to 4 million MSCs per kg is safe in lung transplant recipients with BOS.
Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
AbstractOutcomes have improved considerably in multiple myeloma (MM), but disparities among racial‐ethnic groups exist. Differences in utilization of novel therapeutics are likely contributing factors. We explored such differences from the SEER‐Medicare database. A utilization analysis of lenalidomide, thalidomide, bortezomib, and stem cell transplant (SCT) was performed for patients diagnosed with MM between 2007 and 2009, including use over time, use by race, time‐dependent trends for each racial subgroup, and survival analysis. A total of 5338 MM patients were included with median 2.4‐year follow‐up. Within the first year of MM diagnosis, utilization of lenalidomide, bortezomib, SCT, and more than one novel agent increased over time while utilization of thalidomide decreased. There was significantly lower utilization of lenalidomide among African‐Americans (P < 0.01), higher thalidomide use among Hispanics and Asians (P < 0.01), and lower bortezomib use among Asians (P < 0.01). Hispanics had the highest median number of days to first dose of bortezomib (P = 0.02) and the lowest utilization of SCT (P < 0.01). Hispanics and Asians were the only groups without notable increases in lenalidomide and bortezomib use, respectively. SCT utilization increased over time for all except African‐Americans. SCT use within the first year after diagnosis was associated with better overall survival (HR 0.52; 95% CI: 0.4–0.68), while bortezomib use was associated with inferior survival (HR 1.14; 95% CI 1.02–1.28). We noted considerable variability in MM therapeutics utilization with seeming inequity for racial‐ethnic minorities. These trends should be considered to eliminate drug access and utilization disparities and achieve equitable benefit of therapeutic advances across all races.
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures
Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Effect of Body Position on Epsicleral Venous Pressure in Healthy Subjects