AbstractBackgroundTransvenous lead extraction (TLE) is increasingly considered in cardiac implantable electronic device management. Heart failure (HF) might be associated with mortality risks after the TLE procedure. This study aims to assess mortality risk in HF patients undergoing TLE.MethodWe searched MEDLINE and Embase databases from inception to June 2022 to identify articles that included patients with and without HF who underwent TLE, which reported mortality in both groups. The pooled effect size was calculated with a random‐effects model and 95% CI to compare post‐TLE mortality between the two groups.ResultsEleven studies were included in the analysis. Each left ventricular ejection fraction (LVEF) increased by 1% was associated with reduced mortality by 2% (HR = 0.98, 95% CI: 0.97–0.99, I2 = 74.9%, p < .01). The presence of HF compared to those without HF was associated with higher mortality rates (OR: 3.04, 95% CI: 2.56–3.61, I2 = 0.0%, p < .531). There was a significant increase in the mortality rates in patients with New York Heart Association (NYHA) function class III (OR: 2.29, 95% CI: 1.29–4.06, I2 = 0.0%, p = .498) and NYHA IV (OR: 8.5, 95% CI: 2.98–24.3, I2 = 0.0%, p = .997).ConclusionsOur study found that post‐TLE mortality decreases by 2% as LVEF increases by 1%, also mortality is higher in patients with NYHA III and IV.
Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. This study sought to determine the causes of early mortality (≤90 days) after AF ablation. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6723 patients were included in the study. The 90-day all-cause mortality rate was 0.22% (n=15). Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06% (n=4). Conclusions: AF ablation procedure has a 90-day mortality of 0.22%, and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was low at 0.06%. Further studies are required to investigate causes and risk factors associated with sudden death in this patient population.
Subcutaneous implantable cardioverter‐defibrillator noise following left ventricular assist device implantation
AbstractBackgroundThe incidence and impact of noise in a subcutaneous implantable cardioverter defibrillator (S‐ICD) after left ventricular assist device (LVAD) implantation is not well established.MethodsWe performed a retrospective study of patients implanted with LVAD and with a pre‐existing S‐ICD between January 2005 and December 2020 at the three Mayo Clinic centers (Minnesota, Arizona, and Florida).ResultsOf the 908 LVAD patients, a pre‐existing S‐ICD was present in 9 patients (mean age 49.1 ± 13.7 years, 66.7% males), 100% with Boston Scientific third‐generation EMBLEM MRI S‐ICD, 11% with HeartMate II (HM II), 44% with HeartMate 3 (HM 3), and 44% with HeartWare (HW) LVAD. The incidence of noise from LVAD‐related electromagnetic interference (EMI) was 33% and was only seen with HM 3 LVAD. Multiple measures attempted to resolve noise, including using alternative S‐ICD sensing vector, adjusting S‐ICD time zone, and increasing LVAD pump speed, were unsuccessful, necessitating S‐ICD device therapies to be turned off permanently.ConclusionsThe incidence of LVAD‐related S‐ICD noise is high in patients with concomitant LVAD and S‐ICD with significant impact on device function. As conservative management failed to resolve the EMI, the S‐ICDs had to be programmed off to avoid inappropriate shocks. This study highlights the importance of awareness of LVAD‐SICD device interference and the need to improve S‐ICD detection algorithms to eliminate noise.
Chronic kidney disease is associated with increased all‐cause mortality in transvenous lead extraction: A systematic review and meta‐analysis
AbstractBackgroundThe impact of chronic kidney disease (CKD) or end‐stage renal disease (ESRD) on patients receiving transvenous lead extraction (TLE) is not well‐established. We performed a systematic review and meta‐analysis to explore the association between CKD and all‐cause mortality in TLE.MethodsWe searched the databases of PubMed and EMBASE from inception to April 2022. Included studies were published TLE studies that compared the risk of mortality in CKD patients compared to control patients. Data from each study were combined using the random‐effects model.ResultsEight studies (5,013 patients) were included. Compared with controls, CKD patients had a significantly higher risk of overall all‐cause mortality (hazard ratio [HR] = 2.14, 95% confidence interval [CI]: 1.65–2.77, I2 = 51.1%, p < .001). The risk of overall all‐cause mortality increased with the severity of CKD for nonspecific CKD (HR = 2.01, 95% CI: 1.49–2.69, I2 = 53.4, p < .001) and ESRD (HR = 2.79, 95% CI: 1.85–4.23, I2 = 0%, p < .001). The risk of all‐cause mortality in CKD is double at follow‐up ≤1 year (HR = 1.99, 95% CI: 1.29–3.09, I2 = 50.9%, p = .002) and higher at follow‐up >1 year (HR = 2.36, 95% CI: 1.63–3.42, I2 = 59.7%, p < .001).ConclusionsOur meta‐analysis demonstrates a significantly increased risk of overall all‐cause mortality in patients with CKD who underwent TLE compared to controls.
Outcomes of catheter ablation for ventricular tachycardia in patients with sarcoidosis: Insights from the National Inpatient Sample database (2002–2018)
AbstractIntroductionData on utilization, major complications, and in‐hospital mortality of catheter ablation (CA) for sarcoidosis‐related ventricular tachycardia (VT) are limited. We sought to determine the outcomes of sarcoidosis‐related VT, and incidence and predictors of complications associated with the CA procedure.MethodsWe queried the 2002–2018 National Inpatient Sample database to identify patients aged ≥18 years with sarcoidosis admitted with VT. A 1:3 propensity score‐matched (PSM) analysis was used to compare patient outcomes between CA and medically managed groups. Multivariable regression was performed to determine independent predictors of in‐hospital mortality and procedural complications associated with the CA procedure.ResultsOf 3220 sarcoidosis patients with VT, 132 (4.1%) underwent CA. Patients who underwent CA were younger, male predominant, more likely Caucasian, had differences in baseline comorbidities including more likely to have heart failure, less likely to have prior myocardial infarction, COPD, or severe renal disease, had a higher mean household income, and more likely admitted to a larger/urban teaching hospital. After PSM, we examined 106 CA cases and 318 medically managed cases. There was a trend toward a lower in‐hospital mortality rate in the CA group when compared to the medically managed group (1.9% vs. 6.6%, p = 0.08). The most common complications were pericardial drainage (5.3%), postoperative hemorrhage (3.8%), accidental puncture periprocedure (3.0%), and cardiac tamponade (2.3%). Independent predictors of in‐hospital mortality and procedural complications among the CA group included congestive heart failure (odds ratio [OR], 13.2; 95% confidence interval [CI], 1.7–104.2) and mild to moderate renal disease (OR, 3.9; 95% CI, 1.1–13.3).ConclusionsCompared to patients with sarcoidosis‐related VT who received medical therapy alone, those who underwent CA have a trend for a lower mortality rate despite procedure‐related complications occurring as high as 9.1%. Additional studies are recommended to better evaluate the benefits and risks of VT ablation in this group.
Cardiac resynchronization therapy response in cardiac sarcoidosis
AbstractIntroductionCardiac sarcoidosis (CS) is a nonischemic cardiomyopathy (NICM) characterized by infiltration of noncaseating granulomas involving the heart with highly variable clinical manifestations that can include conduction abnormalities and systolic heart failure. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its efficacy in patients with CS.ObjectiveTo determine if CRT improved cardiac remodeling in patients with CS.MethodsWe retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at the Mayo Clinic enterprise from 2000 to 2021. Baseline characteristics, imaging parameters, heart failure hospitalizations and need for advanced therapies, and major adverse cardiac events (MACE) were assessed.ResultsOur cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. Eighteen (32.7%) patients had definite CS, 21 (38.2%) had probable CS, while 16 (29.1%) had presumed CS, and 26 (47.3%) with extracardiac sarcoidosis. The majority underwent CRT‐D implantation (n = 52, 94.5%) and 3 (5.5%) underwent CRT‐P implantation with 67.3% of implanted devices being upgrades from prior pacemakers or implantable cardioverter defibrillators. At 6 months postimplantation there was no significant improvement in ejection fraction (34.8 ± 10.9% vs. 37.7 ± 14.2%, p = .331) or left ventricular end‐diastolic diameter (58.5 ± 10.2 vs. 57.5 ± 8.1 mm, p = .236), though mild improvement in left ventricular end systolic diameter (49.1 ± 9.9 vs. 45.7± 9.9 mm, p < .0001). Within the first 6 months postimplantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow‐up of 4.1± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent left ventricular assist device implantation and 7 (12.7%) patients died.ConclusionsOur findings suggest variable response to CRT in patients with CS with no overall improvement in ventricular function within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.
Influence of endurance sports on atrial fibrillation ablation outcomes
AbstractObjectivesWe aimed to investigate the outcomes of pulmonary vein isolation in athletes.MethodsWe retrospectively identified endurance athletes who underwent catheter ablation at our institution (2004–2018). Endurance athletes were defined as participating in competitive athletics for at least 1500 lifetime hours in sports at the IB or IIA Bethesda classification or higher. Primary endpoints were freedom from atrial arrhythmias at 12, 24, and 36 months after the procedure. Secondary endpoints were defined as qualitative improvement in symptoms allowing athletes to return to their previous level of activity. Athletes were compared with a control group of nonathletes in a 3‐to‐1 matched analysis by age and sex.ResultsA total of 39 endurance athletes who underwent catheter ablation were identified during the study period. At 12 months, there was no difference in treatment outcomes for athletes versus nonathletes (relative risk [RR], 1.06; 95% CI, 0.92–1.22; p = .40). Freedom from atrial arrhythmias was 35% less likely in athletes than nonathletes at 24 months (RR, 0.65; 95% CI, 0.50–0.83; p < .001) and 42% less likely at 36 months (RR, 0.58; 95% CI, 0.41–0.79; p < .001). Overall, 77% of the athletes were able to return to their previous level of activity following catheter ablation.ConclusionEndurance athletes with atrial fibrillation appear to have higher rates of atrial arrhythmia recurrence than nonathletes after catheter ablation, with higher rates of atypical flutter. The majority of athletes were able to return to their previous level of activity after ablation.
Complications of Endobronchial Valve Placement for Bronchoscopic Lung Volume Reduction
Background: Patients with advanced emphysema experience breathlessness due to impaired respiratory mechanics and diaphragm dysfunction. Bronchoscopic lung volume reduction (BLVR) is a minimally invasive bronchoscopic procedure done to reduce hyperinflation and air trapping, promoting atelectasis in the targeted lobe and allowing improved respiratory mechanics. Real-world data on safety and complications outside of clinical trials of BLVR are limited. Methods: We queried the US Food and Drug Administrations (FDA) Manufacturers and User Device Experience database from May 2019 to June 2020 for reports involving BLVR with endobronchial valve (EBV) placement. Events were reviewed for data analysis. Results: We identified 124 cases of complications during BLVR with EBV implantation. The most-reported complication was pneumothorax (110/124, 89%), all of which required chest tube placement. A total of 54 of these cases (54/110, 49%) were complicated by persistent air leak requiring additional interventions. Repeat bronchoscopy was needed to remove the valves in 28 patients, 12 were discharged with a Heimlich valve, and 10 had an additional pleural catheter placed. The other complications of BLVR with EBV placement included respiratory failure (6/124, 5%), pneumonia (4/124, 3%), hemoptysis (2/124, 1.6%), valve migration (1/124, 1%), and pleural effusion (1/124, 1%). A total of 14 deaths were reported during that year. Conclusion: Pneumothorax is the most-reported complication for BLVR with EBV placement, and in 65% of cases, pneumothorax is managed without removing valves. Importantly, 14 deaths were reported during that timeframe. Further studies are needed to estimate the true magnitude of the complications associated with BLVR.
Abstract 13422: The Impact of Cardiac Resynchronization Therapy With Defibrillator in Patients With Nonischemic Cardiomyopathy
Introduction: Real-world data on the significance of adding a defibrillator to cardiac resynchronization therapy (CRT-D) in patients with nonischemic cardiomyopathy (NICM) are limited. Hypothesis: CRT-D is associated with a lower risk of mortality and heart failure (HF) readmissions compared to CRT-P in NICM. Methods: We identified patients with NICM who underwent CRT-D and CRT without an ICD (CRT-P) by analyzing the nationwide readmission database from October 2015- December 2018 and using appropriate ICD-10 CM codes. Propensity score matching was performed to adjust for the confounders. Kaplan Meier curves were utilized for time to event analysis. Cox proportional hazard regression was used to generate hazard ratios. All-cause mortality at 6 months was the primary outcome whereas readmission due to HF and any other cause at 6 months were defined as secondary outcomes. Results: Post-PSM, 3054 patients with NICM underwent CRT-P, and 2863 patients underwent CRT-D placement. CRT-D did not show any benefit over CRT-P in reducing all-cause mortality at 6 months (2.92% vs. 2.79%, HR: 0.84, 95% CI: 0.61-1.16, p=0.29). Similarly, there was no difference in terms of readmissions due to other causes among both groups of patients (36.25% vs. 31.85%, HR: 0.98, 95% CI: 0.89-1.08, p=0.77). However, patients with CRT-P implantations had a lower risk of HF readmissions compared to the CRT-D group (10.05% vs. 14.25%, HR: 0.67, 95% CI: 0.58-0.79, p<0.0001). Conclusions: The addition of a defibrillator to CRT failed to show a survival benefit in patients with NICM. Moreover, HF readmissions were higher in CRT-D patients compared to CRT-P.
Abstract 10726: Cardiac Resynchronization Therapy Response in Cardiac Sarcoidosis
Introduction: Cardiac Sarcoidosis (CS) is a non-ischemic cardiomyopathy (NICM) characterized by infiltration of non-caseating granulomas involving in the heart with highly variable clinical manifestations. Cardiac resynchronization therapy (CRT) has shown significant promise in NICM, though little is known about its effectiveness in patients with CS. Hypothesis: We sought to determine if CRT improved cardiac remodeling and reduced hospitalizations in patients with CS. Methods: We retrospectively reviewed all patients with a clinical or histological diagnosis of CS who underwent CRT implantation at a Mayo Clinic site from 2000-2021. Baseline characteristics, echocardiographic parameters, heart failure hospitalization, and major adverse cardiac events (MACE) were assessed. Results: Our cohort was comprised of 55 patients with 61.8% male and a mean age of 58.7 ± 10.9 years. At baseline, 38 (69.1%) patients had isolated CS, while 17 (30.9%) had evidence of CS with extra-cardiac sarcoidosis. The overwhelming majority underwent CRT-D implantation (n=52, 94.5%) with 67.3% of implanted devices upgrades from prior pacemaker or implantable cardioverter defibrillator. At 6 months post-implantation there was no significant different in ejection fraction (34.8 ± 10.9 % vs. 37.7 ± 14.2 %, p = 0.237), left ventricular end systolic diameter (49.1 ± 9.9 mm vs. 45.7 ± 9.9 mm, p = 0.077) or left ventricular end-diastolic diameter (58.5 ± 10.2 mm vs. 57.5 ± 8.1 mm, p = 0.574). Within the first 6 months post-implantation, 5 (9.1%) patients sustained a heart failure hospitalization. At a mean follow up of 4.1 ± 3.7 years, 14 (25.5%) patients experienced a heart failure hospitalization, 11 (20.0%) underwent cardiac transplantation, 1 (1.8%) underwent LVAD implantation and 7 (12.7%) patients died. Conclusions: Our findings suggest a poor response to CRT in patients with CS with no significant evidence of reverse remodeling within 6 months and a substantial proportion of patients progressing to advanced heart failure therapies.